Search NASA⌕ Search

SEARCH · Search NASA

Results for “throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A high-throughput assay of NK cell activity in whole blood and its clinical application

Graphical abstract: - Highlights: • We demonstrated a simple assay of NK cell activity from whole blood. • The measurement of secreted IFN-γ from NK cell enables high-throughput screening. • The NKA assay was validated by clinical results of colorectal cancer patients. - Abstract: Natural killer (NK) cells are lymphocytes of the innate immune system and have the ability to kill tumor cells and virus-infected cells without prior sensitization. Malignant tumors and viruses have developed, however, strategies to suppress NK cells to escape from their responses. Thus, the evaluation of NK cell activity (NKA) could be invaluable to estimate the status and the outcome of cancers, viral infections, and immune-mediated diseases. Established methods that measure NKA, such as {sup 51}Cr release assay and CD107a degranulation assay, may be used to determine NK cell function, but they are complicated and time-consuming because they require isolation of peripheral blood mononuclear cells (PBMC) or NK cells. In some cases these assays require hazardous material such as radioactive isotopes. To overcome these difficulties, we developed a simple assay that uses whole blood instead of PBMC or isolated NK cells. This novel assay is suitable for high-throughput screening and the monitoring of diseases, because it employs serum of ex vivo stimulated whole blood to detect interferon (IFN)-γ secreted from NK cells as an indicator of NKA. After the stimulation of NK cells, the determination of IFNγ concentration in serum samples by enzyme-linked immunosorbent assay (ELISA) provided a swift, uncomplicated, and high-throughput assay of NKA ex vivo. The NKA results microsatellite stable (MSS) colorectal cancer patients was showed significantly lower NKA, 263.6 ± 54.5 pg/mL compared with healthy subjects, 867.5 ± 50.2 pg/mL (p value <0.0001). Therefore, the NKA could be utilized as a supportive diagnostic marker for microsatellite stable (MSS) colorectal cancer.

60 APPLIED LIFE SCIENCES↗

Protein engineering of aldolase LbDERA for enhanced activity toward real substrates with a high-throughput screening method coupled with an aldehyde dehydrogenase

A new high-throughput method for screening 2-deoxyribose-5-phosphate aldolase variants with a higher activity toward aldol reaction of unnatural aldehydes was established for the first time by coupling with an aldehyde dehydrogenase LeADH. The error-prone PCR and site-directed saturation mutagenesis libraries of aldolase LbDERA were constructed and screened using the high-throughput method. Two improved variants, LbDERA{sub T29L} and LbDERA{sub F163Y}, were identified and combined, giving a double mutant LbDERA{sub T29L/F163Y} which showed 7-fold higher activity than the native enzyme. The crystal structure of LbDERA{sub T29L/163Y} obtained by X-ray diffraction with 1.77 Å resolution revealed the structural changes responsible for the significant activity improvement. - Highlights: • A high-throughput method for screening aldolase variants was established. • A variant LbDERA{sub T29L/F163Y} with 7-fold improved activity was identified. • The crystal structure reveals structure changes responsible for activity improvement.

60 APPLIED LIFE SCIENCES↗

Overcoming the sensitivity vs. throughput tradeoff in Coulter counters: A novel side counter design

We report microfabricated Coulter counters are attractive for point of care (POC) applications since they are label free and compact. However, these approaches inherently suffer from a trade off between sample throughput and sensitivity. The counter measures a change in impedance due to displaced fluid volume by passing cells, and thus the counter's signal increases with the fraction of the sensing volume displaced. Reducing the size of the sensing region requires reductions in volumetric throughput in the absence of increased hydraulic pressure and sensor bandwidth. The risk of mechanical clog formation, rendering the counter inoperable, increases markedly with reductions in the size of the constriction aperture. We present here a microfluidic coplanar Coulter counter device design that overcomes the problem of constriction clogging while capable of operating in microfluidic channels filled entirely with highly conductive sample. The device utilizes microfabricated planar electrodes projecting into one side of the microfluidic channel and is easily integrated with upstream electronic, hydrodynamic, or other focusing units to produce efficient counting which could allow for dramatically increased volumetric and sample throughput. The design lends itself to simple, cost effective POC applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

3D-cultured neural stem cell microarrays on a micropillar chip for high-throughput developmental neurotoxicology

Highlights: • Optimum cell viability and spheroid formation observed in 3D cultured NSC microarrays. • Lentiviruses constructed for measuring the expression levels of NSC biomarkers. • Differentiation of ReNcell VM assessed after growth factor removal and with additives. • High-throughput assessment of self-renewal and differentiation demonstrated in 3D cell culture. Numerous chemicals including environmental toxicants and drugs have not been fully evaluated for developmental neurotoxicity. A key gap exists in the ability to predict accurately and robustly in vivo outcomes based on in vitro assays. This is particularly the case for predicting the toxicity of chemicals on the developing human brain. A critical need for such in vitro assays is choice of a suitable model cell type. To that end, we have performed high-throughput in vitro assessment of proliferation and differentiation of human neural stem cells (hNSCs). Conventional in vitro assays typically use immunofluorescence staining to quantify changes in cell morphology and expression of neural cell-specific biomarkers, which is often time-consuming and subject to variable specificities of available antibodies. To alleviate these limitations, we developed a miniaturized, three-dimensional (3D) hNSC culture with ReNcell VM on microarray chip platforms and established a high-throughput promoter-reporter assay system using recombinant lentiviruses on hNSC spheroids to assess cell viability, self-renewal, and differentiation. Optimum cell viability and spheroid formation of 3D ReNcell VM culture were observed on a micropillar chip over a period of 9 days in a mixture of 0.75% (w/v) alginate and 1 mg/mL growth factor reduced (GFR) Matrigel with 25 mM CaCl{sub 2} as a crosslinker for alginate. In addition, 3D ReNcell VM culture exhibited self-renewal and differentiation on the microarray chip platform, which was efficiently monitored by enhanced green fluorescent protein (EGFP) expression of four NSC-specific biomarkers including sex determining region Y-box 2 (SOX2), glial fibrillary acidic protein (GFAP), synapsin1, and myelin basic protein (MBP) with the promoter-reporter assay system.

60 APPLIED LIFE SCIENCES↗

Automated Coupling of Nanodroplet Sample Preparation with Liquid Chromatography–Mass Spectrometry for High-Throughput Single-Cell Proteomics

Single-cell proteomics can provide critical biological insight into the cellular heterogeneity that is masked by bulk-scale analysis. Here, we have developed a nanoPOTS (nanodroplet processing in one pot for trace samples) platform and demonstrated its broad applicability for single-cell proteomics. However, because of nanoliter-scale sample volumes, the nanoPOTS platform is not compatible with automated LC-MS systems, which significantly limits sample throughput and robustness. To address this challenge, we have developed a nanoPOTS autosampler allowing fully automated sample injection from nanowells to LC-MS systems. We also developed a sample drying, extraction, and loading workflow to enable reproducible and reliable sample injection. The sequential analysis of 20 samples containing 10 ng tryptic peptides demonstrated high reproducibility with correlation coefficients of >0.995 between any two samples. The nanoPOTS autosampler can provide analysis throughput of 9.6, 16, and 24 single cells per day using 120, 60, and 30 min LC gradients, respectively. As a demonstration for single-cell proteomics, the autosampler was first applied to profiling protein expression in single MCF10A cells using a label-free approach. At a throughput of 24 single cells per day, an average of 256 proteins was identified from each cell and the number was increased to 731 when the Match Between Runs algorithm of MaxQuant was used. Using a multiplexed isobaric labeling approach (TMT-11plex), ~77 single cells could be analyzed per day. We analyzed 152 cells from three acute myeloid leukemia cell lines, resulting in a total of 2558 identified proteins with 1465 proteins quantifiable (70% valid values) across the 152 cells. These data showed quantitative single-cell proteomics can cluster cells to distinct groups and reveal functionally distinct differences.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Throughput Single Cell Proteomics Enabled by Multiplex Isobaric Labelling in a Nanodroplet Sample Preparation Platform

Effective extension of mass spectrometry-based proteomics to single cells remains challenging. Herein we combined microfluidic nanodroplet technology with tandem mass tag (TMT) isobaric labeling to significantly improve analysis throughput and proteome coverage for single mammalian cells. Isobaric labeling facilitated multiplex analysis of single cell-sized protein quantities to a depth of ~1,600 proteins with median CV of 10.9% and correlation coefficient of 0.98. To demonstrate in-depth high throughput single cell analysis, the platform was applied to measure protein expression in 72 single cells from three murine cell populations (epithelial, immune, and endothelial cells) in <2 days instrument time with over 2,300 proteins identified. Principal component analysis grouped the single cells into three distinct populations based on protein expression with each population characterized by well-known cell-type specific markers. Our platform enables high throughput and unbiased characterization of single cell heterogeneity at the proteome level.

Dou, Maowei↗

Coupling High-Throughput and Targeted Screening for Identification of Nonobvious Metabolic Engineering Targets

Identification of metabolic engineering targets is a fundamental challenge in strain development programs. While high-throughput (HTP) genetic engineering methodologies capable of generating vast diversity are being developed at a rapid rate, a majority of industrially interesting molecules cannot be screened at sufficient throughput to leverage these techniques. We propose a workflow that couples HTP screening of common precursors (e.g., amino acids) that can be screened either directly or by artificial biosensors, with low-throughput targeted validation of the molecule of interest to uncover nonintuitive beneficial metabolic engineering targets and combinations hereof. Using this workflow, we identified several nonobvious novel targets for improving p-coumaric acid (p-CA) and L -DOPA production from two large 4k gRNA libraries each deregulating 1000 metabolic genes in the yeast Saccharomyces cerevisiae. We initially screened yeast cells transformed with gRNA library plasmids for individual regulatory targets improving the production of l-tyrosine-derived betaxanthins, identifying 30 targets that increased intracellular betaxanthin content 3.5–5.7 fold. Hereafter, we screened the targets individually in a high-producing p-CA strain, narrowing down the targets to six that increased the secreted titer by up to 15%. To investigate whether any of the six targets could be additively combined to improve p-CA production further, we created a gRNA multiplexing library and subjected it to our proposed coupled workflow. The combination of regulating PYC1 and NTH2 simultaneously resulted in the highest (threefold) improvement of the betaxanthin content, and an additive trend was also observed in the p-CA strain. Lastly, we tested the initial 30 targets in a L -DOPA producing strain, identifying 10 targets that increased the secreted titer by up to 89%, further validating our screening by proxy workflow. This coupled approach is useful for strain development in the absence of direct HTP screening assays for products of interest.

59 BASIC BIOLOGICAL SCIENCES↗

High-throughput terahertz imaging: progress and challenges

Abstract Many exciting terahertz imaging applications, such as non-destructive evaluation, biomedical diagnosis, and security screening, have been historically limited in practical usage due to the raster-scanning requirement of imaging systems, which impose very low imaging speeds. However, recent advancements in terahertz imaging systems have greatly increased the imaging throughput and brought the promising potential of terahertz radiation from research laboratories closer to real-world applications. Here, we review the development of terahertz imaging technologies from both hardware and computational imaging perspectives. We introduce and compare different types of hardware enabling frequency-domain and time-domain imaging using various thermal, photon, and field image sensor arrays. We discuss how different imaging hardware and computational imaging algorithms provide opportunities for capturing time-of-flight, spectroscopic, phase, and intensity image data at high throughputs. Furthermore, the new prospects and challenges for the development of future high-throughput terahertz imaging systems are briefly introduced.

36 MATERIALS SCIENCE↗

High-throughput design of high-performance lightweight high-entropy alloys

Developing affordable and light high-temperature materials alternative to Ni-base superalloys has significantly increased the efforts in designing advanced ferritic superalloys. However, currently developed ferritic superalloys still exhibit low high-temperature strengths, which limits their usage. Here we use a CALPHAD-based high-throughput computational method to design light, strong, and low-cost high-entropy alloys for elevated-temperature applications. Through the high-throughput screening, precipitation-strengthened lightweight high-entropy alloys are discovered from thousands of initial compositions, which exhibit enhanced strengths compared to other counterparts at room and elevated temperatures. The experimental and theoretical understanding of both successful and failed cases in their strengthening mechanisms and order-disorder transitions further improves the accuracy of the thermodynamic database of the discovered alloy system. This study shows that integrating high-throughput screening, multiscale modeling, and experimental validation proves to be efficient and useful in accelerating the discovery of advanced precipitation-strengthened structural materials tuned by the high-entropy alloy concept.

36 MATERIALS SCIENCE↗

High-throughput micro-scale bandgap mapping for perovskite-inspired materials with complex composition space

Abstract To realize the full promise of high-throughput experimental workflows, the rate of sample synthesis must be matched by that of characterization. Of growing interest are contactless optical techniques that can rapidly measure material homogeneity and properties. Here, we present a hyperspectral imaging method to measure local optical bandgap distributions within samples, utilizing spatially-resolved reflectance spectra coupled with automated data analysis. We collect approximately one million optical bandgap data across the compositional space of Cs 3 (Bi x Sb 1-x ) 2 (Br y I 1-y ) 9 perovskite-inspired materials. Our results show non-monotonic bandgap variations (i.e., bandgap bowing) along six composition gradient sequences, in addition to identifying samples with multiple bandgaps in statistics. High-throughput transient absorption spectroscopy reveals that within these compositions, the depletion of the ground state carriers to excited states occurred at discrete energy levels with independent carrier dynamics, consistent with the bandgap observation and indicative of phase separation. This work demonstrates the potential for rapid optical measurements to assess material quality and homogeneity in a high-throughput experimental setting, supporting screening and recipe optimization of optoelectronic material candidates with desired carrier dynamics and optical properties.

Science & Technology - Other Topics↗

Spatial tuning of acoustofluidic pressure nodes by altering net sonic velocity enables high-throughput, efficient cell sorting

Particle sorting using acoustofluidics has enormous potential but widespread adoption has been limited by complex device designs and low throughput. Here, we report high-throughput separation of particles and T lymphocytes (600 μL min -1 ) by altering the net sonic velocity to reposition acoustic pressure nodes in a simple two-channel device. Finally, the approach is generalizable to other microfluidic platforms for rapid, high-throughput analysis.

59 BASIC BIOLOGICAL SCIENCES↗

High-throughput Single-Cell Proteomics and Transcriptomics from the Same Cells with a Nanoliter-Scale Spin-Transfer Approach

Single-cell multiomic platforms provide a comprehensive snapshot of cellular states and cell types by offering critical insights into the spatiotemporal regulation of biomolecular networks at a systems level, thereby defining the basis of multicellularity. Here, we introduce nanoSPINS, an advanced platform that enables high-throughput profiling and integrative analysis of the transcriptome and proteome from the same single cells using RNA sequencing and isobaric labeling LC-MS-based proteomics, respectively. NanoSPINS can efficiently transfer mRNA-containing droplets across two microarrays via a centrifugation-based approach, while proteins are retained on the initial platform. Benchmarking of nanoSPINS on two cell lines demonstrates its ability to generate global proteomic and transcriptomic profiles that align well with previously established methodologies/platforms. The incorporation of isobaric TMTpro labeling into this single-cell multiomics platform significantly enhances the throughput of single-cell proteomic analyses. Through the high-throughput quantification of the proteome and transcriptome, nanoSPINS not only facilitates the identification of molecular features at both mRNA and protein level but also provides larger sample sizes for improved statistical power in clustering and differential abundance. Given the broad applicability of single-cell multiomics in biological research and clinical settings, we believe nanoSPINS represents a powerful platform for the characterization of heterogeneous cell populations.

multi 'omics↗

Theory and implementation of a very high throughput true random number generator in field programmable gate array

The contribution of this paper is proposing a new entropy extraction mechanism based on sampling phase jitter in ring oscillators to make a high throughput true random number generator in a field programmable gate array (FPGA) practical. Starting from experimental observation and analysis of the entropy source in FPGA, a multi-phase sampling method is exploited to harvest the clock jitter with a maximum entropy and fast sampling speed. This parametrized design is implemented in a Xilinx Artix-7 FPGA, where the carry chains in the FPGA are explored to realize the precise phase shifting. The generator circuit is simple and resource-saving, so that multiple generation channels can run in parallel to scale the output throughput for specific applications. The prototype integrates 64 circuit units in the FPGA to provide a total output throughput of 7.68 Gbps, which meets the requirement of current high-speed quantum key distribution systems. The randomness evaluation, as well as its robustness to ambient temperature, confirms that the new method in a purely digital fashion can provide high-speed high-quality random bit sequences for a variety of embedded applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fulfilling the promise of the materials genome initiative with high-throughput experimental methodologies

The Materials Genome Initiative, a national effort to introduce new materials into the market faster and at lower cost, has made significant progress in computational simulation and modeling of materials. To build on this progress, a large amount of experimental data for validating these models, and informing more sophisticated ones, will be required. High-throughput experimentation generates large volumes of experimental data using combinatorial materials synthesis and rapid measurement techniques, making it an ideal experimental complement to bring the Materials Genome Initiative vision to fruition. This paper reviews the state-of-the-art results, opportunities, and challenges in high-throughput experimentation for materials design. As a result, a major conclusion is that an effort to deploy a federated network of high-throughput experimental (synthesis and characterization) tools, which are integrated with a modern materials data infrastructure, is needed.

36 MATERIALS SCIENCE↗

E × B configurations for high-throughput plasma mass separation: An outlook on possibilities and challenges

High-throughput plasma separation based on atomic mass holds promise for offering unique solutions to a variety of high-impact societal applications. Through the mass differential effects they exhibit, crossed-field configurations can in principle be exploited in various ways to separate ions based on atomic mass. Here, we review some of the E × B mass filter concepts proposed to date and underline how the practicality of these concepts is conditioned upon the ability to sustain a suitable perpendicular electric field in a plasma for parameters compatible with high-throughput operation. We show that while the limited present predictive capabilities do not make it possible to confirm this possibility, past experimental results suggest that end-electrode biasing may be effective, at least for certain electric field values. We conclude that a better understanding of cross-field conductivity is needed to confirm these results and confirm the potential of crossed-field configurations for high-throughput separation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-throughput small-angle X-ray scattering reveals effective structure factor transitions linked to high-concentration antibody viscosity

High-concentration monoclonal antibody (mAb) formulations are often constrained by elevated viscosity, largely driven by protein–protein interactions, which complicates manufacturing and limits subcutaneous delivery. Early viscosity risk assessment is essential during discovery, yet traditional measurements require large sample volumes, and lack high-throughput capability. Here, we develop a high-throughput small-angle X-ray scattering (SAXS) protocol to detect mAb self-association at dilute concentrations, enabling early predictive insights into high-concentration viscosity. Synchrotron SAXS measurements were conducted for 21 mAbs formulated in a histidine buffer at pH 6.0. An initial subset of 10 mAbs analyzed across 1–150 mg/mL revealed that effective structure factor transitions in the low-q region, indicative of interparticle interactions, consistently emerged below 25 mg/mL. Subsequently, 11 additional mAbs were analyzed at 1–25 mg/mL using automated liquid handling and flow cells to enable high-throughput screening. High-viscosity mAbs exhibited detectable low-q upturns at concentrations ≤10 mg/mL, whereas low-viscosity mAbs showed downturns. A classification criterion based on effective structure factor transitions accurately classified all high- and low-viscosity mAbs at 150 mg/mL, offering a scalable, sample-efficient alternative to conventional methods. These results extend recent findings on the concentration-dependent sensitivity of SAXS to short-range attractions, demonstrating that they can emerge at lower concentrations than previously reported. This study presents the most comprehensive and diverse SAXS dataset for mAbs reported to date within a single formulation, providing a valuable resource for developing and validating coarse-grained models that can more accurately capture intermolecular interactions governing high-concentration solution behavior, thereby enabling rational antibody engineering and improved developability.

36 MATERIALS SCIENCE↗

A new fungal large subunit ribosomal RNA primer for high throughput sequencing surveys

The inclusion of phylogenetic metrics in community ecology has provided insights into important ecological processes, particularly when combined with high-throughput sequencing methods; however, these approaches have not been widely used in studies of fungal communities relative to other microbial groups. Two obstacles have been considered: (1) the internal transcribed spacer (ITS) region has limited utility for constructing phylogenies and (2) most PCR primers that target the large subunit (LSU) ribosomal unit generate amplicons that exceed current limits of high-throughput sequencing platforms. We designed and tested a PCR primer (LR22R) to target approximately 300–400 bp region of the D2 hypervariable region of the fungal LSU for use with the Illumina MiSeq platform. Both in silico and empirical analyses showed that the LR22R–LR3 pair captured a broad range of fungal taxonomic groups with a small fraction of non-fungal groups. Phylogenetic placement of publically available LSU D2 sequences showed broad agreement with taxonomic classification. Comparisons of the LSU D2 and the ITS2 ribosomal regions from environmental samples and known communities showed similar discriminatory abilities of the two primer sets. Altogether, these findings show that the LR22R–LR3 primer pair has utility for phylogenetic analyses of fungal communities using high-throughput sequencing methods.

54 ENVIRONMENTAL SCIENCES↗

Enhancing lipid production in plant cells through automated high-throughput genome engineering and phenotyping

Plant bioengineering is a time-consuming and labor-intensive process with no guarantee of achieving desired traits. Here, we present a fast, automated, scalable, high-throughput pipeline for plant bioengineering (FAST-PB) in maize (Zea mays) and Nicotiana benthamiana. FAST-PB enables genome editing and product characterization by integrating automated biofoundry engineering of callus and protoplast cells with single-cell matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). We first demonstrated that FAST-PB could streamline Golden Gate cloning, with the capacity to construct 96 vectors in parallel. Using FAST-PB in protoplasts, we found that PEG2050 increased transfection efficiency by over 45%. For proof-of-concept, we established a reporter-gene-free method for CRISPR editing and phenotyping via mutation of high chlorophyll fluorescence 136. We show that diverse lipids were enhanced up to 6-fold using CRISPR activation of lipid controlling genes. In callus cells, an automated transformation platform was employed to regenerate plants with enhanced lipid traits through introducing multigene cassettes. Lastly, FAST-PB enabled high-throughput single-cell lipid profiling by integrating MALDI-MS with the biofoundry, protoplast, and callus cells, differentiating engineered and unengineered cells using single-cell lipidomics. Furthermore, these innovations massively increase the throughput of synthetic biology, genome editing, and metabolic engineering and change what is possible using single-cell metabolomics in plants.

59 BASIC BIOLOGICAL SCIENCES↗