Search NASA⌕ Search

SEARCH · Search NASA

Results for “time resolved”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Digital Time-Resolved Spot Diagnostic

The digital time-resolved spot diagnostic (D-TRSD) is a fast-response, time-dependent beam diagnostic for measuring the emitted spot size and beam target interactions from radiographic x-ray sources. Legacy streaked TRSD analysis requires image processing and data extraction, which give noisy results. Processed data are used to extract edge spread and corresponding line spread functions. Digital TRSD simplifies this process, eliminating the complexity of streak camera–based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Feasibility experiments on time-resolved fluorosensing applied to oil slicks

The introduction of time resolved observations can provide a very penetrating tool in the practice of laser fluorosensing. The investigations have demonstrated a relevance of multispectral, time resolved analysis for oil fingerprinting. By comparative studies on a variety of crude oils and their most significant fractions, it was found that the process of time decay in a composite oil is characterized by a few steps, which are associated with specific components in the medium light range. The average decay times of these pure fractions are markedly differentiated as to absolute values and spectral spread; as a consequence, the corresponding parameters in the resultant crude are quite sensitive to the particular mixture of these components. Measurements of the time response give then a finer discrimination between oil classes, depending on the relative content of certain fractions. Experiments were pursued with an improved fluorosensor facility, in order to test the application of time resolved fluorosensing to remote samples on water.

Camagni, P.↗

Lateral-Looking Time-Resolved Thermal Wave Microscopy

Time-resolved thermal wave microscopy was used to measure lateral thermal transport in a thin metallic film on an insulating substrate. The basis of this approach is to decompose the reflectivity signal into a component that varies with delay time and a steady state component that varies with pump modulation frequency. The transient component is a summation of thermal waves at integral multiples of the pulse repetition frequency (76 MHz). The steady state component depends only on thermal waves at the pump chopping frequency (10-100 kHz). It is shown that for long delays, the steady state component is dominant and can be used to measure the thermal diffusivity.

36 MATERIALS SCIENCE↗

Simulation of laser-induced coupled electron-nuclear dynamics and time-resolved harmonic spectra in complex systems

We present a theoretical approach for the simulation of time-resolved harmonic spectra, including the effect of nuclear dynamics, which is applicable to complex systems involving many nuclear degrees of freedom. The method is based on the combination of our semiclassical field-induced surface hopping approach for the treatment of laser-induced nuclear dynamics with the time-dependent density functional theory for electron dynamics. We apply our method to the simulation of ultrafast nonadiabatic dynamics and time-resolved harmonic spectra in small silver clusters (Ag{sub 2} and Ag{sub 8}), which exhibit discrete molecularlike electronic transitions. We demonstrate that the harmonic signal is highly sensitive to the nuclear dynamics and thus can be used as a probe of coupled electron-nuclear dynamics, which is complementary to common pump-probe methods such as time-resolved photoelectron spectroscopy. Our simulations allowed us also to determine the mechanism and the time scale of nonradiative relaxation in the 'magic' Ag{sub 8} cluster and have provided a fundamental insight into ultrafast dynamics of metal nanoclusters in the size regime where 'each atom counts'. The excited-state dynamics of Ag{sub 8} involves an isomerization process from the initial structure with T{sub d} symmetry to the quadratic antiprism structure with D{sub 4d} symmetry which takes place on a time scale of {approx}3600 fs and is clearly identified in a time-resolved harmonic signal. Our theoretical approach is generally applicable for the prediction of time-resolved harmonic spectra in complex systems with many nuclear degrees freedom and should serve to stimulate new ultrafast experiments utilizing harmonic signals as a probe for nonadiabatic processes in molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electronic coherences in nonadiabatic molecular photophysics revealed by time-resolved photoelectron spectroscopy

Significance Time-resolved photoelectron spectroscopy (TRPES) is a promising technique for the study of ultrafast molecular processes, such as the nonadiabatic dynamics taking place at conical intersections. Directly accessing the evolution of the coherences generated at the conical intersection should provide most valuable dynamical information. However, the signals are dominated by background contributions due to state populations, and most theoretical treatments completely neglect the role of the coherences. Here we show that distinguishable signatures of molecular coherences appear in TRPES. These can be recorded using currently available ultrashort pulses and unambiguously extracted at the postprocessing stage. The technique thus provides direct access to nonadiabatic coherence dynamics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample-minimizing co-flow cell for time-resolved pump–probe X-ray solution scattering

A fundamental problem in biological sciences is understanding how macromolecular machines work and how the structural changes of a molecule are connected to its function. Time-resolved techniques are vital in this regard and essential for understanding the structural dynamics of biomolecules. Time-resolved small- and wide-angle X-ray solution scattering has the capability to provide a multitude of information about the kinetics and global structural changes of molecules under their physiological conditions. However, standard protocols for such time-resolved measurements often require significant amounts of sample, which frequently render time-resolved measurements impossible. A cytometry-type sheath co-flow cell, developed at the BioCARS 14-ID beamline at the Advanced Photon Source, USA, allows time-resolved pump–probe X-ray solution scattering measurements to be conducted with sample consumption reduced by more than ten times compared with standard sample cells and protocols. The comparative capabilities of the standard and co-flow experimental setups were demonstrated by studying time-resolved signals in photoactive yellow protein.

36 MATERIALS SCIENCE↗

Photodissociation of thioglycolic acid studied by femtosecond time-resolved transient absorption spectroscopy

Steady-state and time-resolved spectroscopies were employed to study the photodissociation of both the neutral (HS-CH{sub 2}-COOH) and doubly deprotonated ({sup -}S-CH{sub 2}-COO{sup -}) forms of thioglycolic acid (TGA), a common surface-passivating ligand used in the aqueous synthesis and organization of semiconducting nanostructures. Room temperature UV-Vis absorption spectroscopy indicated strong absorption by the S{sub 1} and S{sub 2} excited states at 250 nm and 185 nm, respectively. The spectrum also contained a weaker absorption band that extended to approximately 550 nm, which was assigned to the {pi}{sub CO}{sup *}(leftarrow)n{sub O} transition. Femtosecond time-resolved transient absorption spectroscopy was performed on TGA using 400 nm excitation and a white-light continuum probe to provide the temporally and spectrally resolved data. Both forms of TGA underwent a photoinduced dissociation from the excited state to form an {alpha}-thiol-substituted acyl radical ({alpha}-TAR, S-CH{sub 2}-CO). For the acidic form of TGA, radical formation occurred with an apparent time constant of 60 {+-} 5 fs; subsequent unimolecular decay took 400 {+-} 60 fs. Similar kinetics were observed for the deprotonated form of TGA (70 {+-} 10 fs radical formation; 420 {+-} 40 fs decay). The production of the {alpha}-TAR was corroborated by the observation of its characteristic optical absorption. Time-resolved data indicated that the photoinduced dissociation of TGA via cleavage of the C-OH bond occurred rapidly ({<=}100 fs). The prevalence of TGA in aqueous semiconducting nanoparticles makes its absorption in the visible spectral region and subsequent dissociation key to understanding the behavior of nanoscale systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dose calculation for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema

Purpose: The objectives of this study were (i) to develop a dose calculation method for permanent prostate implants that incorporates a clinically motivated model for edema and (ii) to illustrate the use of the method by calculating the preimplant dosimetry error for a reference configuration of {sup 125}I, {sup 103}Pd, and {sup 137}Cs seeds subject to edema-induced motions corresponding to a variety of model parameters. Methods: A model for spatially anisotropic edema that resolves linearly with time was developed based on serial magnetic resonance imaging measurements made previously at our center to characterize the edema for a group of n=40 prostate implant patients [R. S. Sloboda et al., ''Time course of prostatic edema post permanent seed implant determined by magnetic resonance imaging,'' Brachytherapy 9, 354-361 (2010)]. Model parameters consisted of edema magnitude, {Delta}, and period, T. The TG-43 dose calculation formalism for a point source was extended to incorporate the edema model, thus enabling calculation via numerical integration of the cumulative dose around an individual seed in the presence of edema. Using an even power piecewise-continuous polynomial representation for the radial dose function, the cumulative dose was also expressed in closed analytical form. Application of the method was illustrated by calculating the preimplant dosimetry error, RE{sub preplan}, in a 5x5x5 cm{sup 3} volume for {sup 125}I (Oncura 6711), {sup 103}Pd (Theragenics 200), and {sup 131}Cs (IsoRay CS-1) seeds arranged in the Radiological Physics Center test case 2 configuration for a range of edema relative magnitudes ({Delta}=[0.1,0.2,0.4,0.6,1.0]) and periods (T=[28,56,84] d). Results were compared to preimplant dosimetry errors calculated using a variation of the isotropic edema model developed by Chen et al. [''Dosimetric effects of edema in permanent prostate seed implants: A rigorous solution,'' Int. J. Radiat. Oncol., Biol., Phys. 47, 1405-1419 (2000)]. Results: As expected, RE{sub preplan} for our edema model indicated underdosage in the calculation volume with a clear dependence on seed and calculation point positions, and increased with increasing values of {Delta} and T. Values of RE{sub preplan} were generally larger near the ends of the virtual prostate in the RPC phantom compared with more central locations. For edema characteristics similar to the population average values previously measured at our center, i.e., {Delta}=0.2 and T=28 d, mean values of RE{sub preplan} in an axial plane located 1.5 cm from the center of the seed distribution were 8.3% for {sup 131}Cs seeds, 7.5% for {sup 103}Pd seeds, and 2.2% for {sup 125}I seeds. Maximum values of RE{sub preplan} in the same plane were about 1.5 times greater. Note that detailed results strictly apply only for loose seed implants where the seeds are fixed in tissue and move in synchrony with that tissue. Conclusions: A dose calculation method for permanent prostate implants incorporating spatially anisotropic linearly time-resolving edema was developed for which cumulative dose can be written in closed form. The method yields values for RE{sub preplan} that differ from those for spatially isotropic edema. The method is suitable for calculating pre- and postimplant dosimetry correction factors for clinical seed configurations when edema characteristics can be measured or estimated.

60 APPLIED LIFE SCIENCES↗

Instrumentation and methods for efficient time-resolved X-ray crystallography of biomolecular systems with sub-10 ms time resolution

Time-resolved X-ray crystallography has great promise to illuminate structure–function relations and key steps of enzymatic reactions with atomic resolution. The dominant methods for chemically-initiated reactions require complex instrumentation at the X-ray beamline, significant effort to operate and maintain this instrumentation, and enormous numbers (∼10 5 –10 9 ) of crystals per time point. We describe instrumentation and methods that enable high-throughput time-resolved study of biomolecular systems using standard crystallography sample supports and mail-in X-ray data collection at standard high-throughput cryocrystallography synchrotron beamlines. The instrumentation allows rapid reaction initiation by mixing of crystals and substrate/ligand solution, rapid capture of structural states via thermal quenching with no pre-cooling perturbations, and yields time resolutions in the single-millisecond range, comparable to the best achieved by any non-photo-initiated method in both crystallography and cryo-electron microscopy. Our approach to reaction initiation has the advantages of simplicity, robustness, low cost, adaptability to diverse ligand solutions and small minimum volume requirements, making it well suited to routine laboratory use and to high-throughput screening. We report the detailed characterization of instrument performance, present structures of binding of N -acetylglucosamine to lysozyme at time points from 8 ms to 2 s determined using only one crystal per time point, and discuss additional improvements that will push time resolution toward 1 ms.

Indergaard, John A. (ORCID:000000022367699X)↗

Monte Carlo simulations of time-of-flight PET with double-ended readout: calibration, coincidence resolving times and statistical lower bounds

Here, this paper demonstrates through Monte Carlo simulations that a practical positron emission tomograph with (1) deep scintillators for efficient detection, (2) double-ended readout for depth-of-interaction information, (3) fixed-level analog triggering, and (4) accurate calibration and timing data corrections can achieve a coincidence resolving time (CRT) that is not far above the statistical lower bound. One Monte Carlo algorithm simulates a calibration procedure that uses data from a positron point source. Annihilation events with an interaction near the entrance surface of one scintillator are selected, and data from the two photodetectors on the other scintillator provide depth-dependent timing corrections. Another Monte Carlo algorithm simulates normal operation using these corrections and determines the CRT. A third Monte Carlo algorithm determines the CRT statistical lower bound by generating a series of random interaction depths, and for each interaction a set of random photoelectron times for each of the two photodetectors. The most likely interaction times are determined by shifting the depth-dependent probability density function to maximize the joint likelihood for all the photoelectron times in each set. Example calculations are tabulated for different numbers of photoelectrons and photodetector time jitters for three 3 × 3 × 30 mm 3 scintillators: Lu 2 SiO 5 :Ce,Ca (LSO), LaBr 3 :Ce, and a hypothetical ultra-fast scintillator. To isolate the factors that depend on the scintillator length and the ability to estimate the DOI, CRT values are tabulated for perfect scintillator-photodetectors. For LSO with 4000 photoelectrons and single photoelectron time jitter of the photodetector J = 0.2 ns (FWHM), the CRT value using the statistically weighted average of corrected trigger times is 0.098 ns FWHM and the statistical lower bound is 0.091 ns FWHM. For LaBr 3 :Ce with 8000 photoelectrons and J = 0.2 ns FWHM, the CRT values are 0.070 and 0.063 ns FWHM, respectively. For the ultra-fast scintillator with 1 ns decay time, 4000 photoelectrons, and J = 0.2 ns FWHM, the CRT values are 0.021 and 0.017 ns FWHM, respectively. Lastly, the examples also show that calibration and correction for depth-dependent variations in pulse height and in annihilation and optical photon transit times are necessary to achieve these CRT values.

60 APPLIED LIFE SCIENCES↗

An innovative Yb-based ultrafast deep ultraviolet source for time-resolved photoemission experiments

Time- and angle-resolved photoemission spectroscopy is a powerful technique to study ultrafast electronic dynamics in solids. Here, an innovative optical setup based on a 100-kHz Yb laser source is presented. Exploiting non-collinear optical parametric amplification and sum-frequency generation, ultrashort pump (hν = 1.82 eV) and ultraviolet probe (hν = 6.05 eV) pulses are generated. Overall temporal and instrumental energy resolutions of, respectively, 85 fs and 50 meV are obtained. Time- and angle-resolved measurements on BiTeI semiconductor are presented to show the capabilities of the setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel lock-in amplifier assisted femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectroscopy with efficient rejection of superfluorescence background

Superfluorescence appears as an intense background in femtosecond time-resolved fluorescence noncollinear optical parametric amplification spectroscopy, which severely interferes the reliable acquisition of the time-resolved fluorescence spectra especially for an optically dilute sample. Superfluorescence originates from the optical amplification of the vacuum quantum noise, which would be inevitably concomitant with the amplified fluorescence photons during the optical parametric amplification process. Here, we report the development of a femtosecond time-resolved fluorescence non-collinear optical parametric amplification spectrometer assisted with a 32-channel lock-in amplifier for efficient rejection of the superfluorescence background. With this spectrometer, the superfluorescence background signal can be significantly reduced to 1/300–1/100 when the seeding fluorescence is modulated. An integrated 32-bundle optical fiber is used as a linear array light receiver connected to 32 photodiodes in one-to-one mode, and the photodiodes are further coupled to a home-built 32-channel synchronous digital lock-in amplifier. As an implementation, time-resolved fluorescence spectra for rhodamine 6G dye in ethanol solution at an optically dilute concentration of 10{sup −5}M excited at 510 nm with an excitation intensity of 70 nJ/pulse have been successfully recorded, and the detection limit at a pump intensity of 60 μJ/pulse was determined as about 13 photons/pulse. Concentration dependent redshift starting at 30 ps after the excitation in time-resolved fluorescence spectra of this dye has also been observed, which can be attributed to the formation of the excimer at a higher concentration, while the blueshift in the earlier time within 10 ps is attributed to the solvation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Giant self-driven exciton-Floquet signatures in time-resolved photoemission spectroscopy of MoS 2 from time-dependent GW approach

Time-resolved, angle-resolved photoemission spectroscopy (TR-ARPES) is a one-particle spectroscopic technique that can probe excitons (two-particle excitations) in momentum space. We present an ab initio, time-domain GW approach to TR-ARPES and apply it to monolayer MoS 2 . We show that photoexcited excitons may be measured and quantified as satellite bands and lead to the renormalization of the quasiparticle bands. These features are explained in terms of an exciton-Floquet phenomenon induced by an exciton time–dependent bosonic field, which are orders of magnitude stronger than those of laser field–induced Floquet bands in low-dimensional semiconductors. Our findings imply a way to engineer Floquet matter through the coherent oscillation of excitons and open the new door for mechanisms for band structure engineering.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fast time-resolved electrostatic force microscopy: Achieving sub-cycle time resolution

The ability to measure microsecond- and nanosecond-scale local dynamics below the diffraction limit with widely available atomic force microscopy hardware would enable new scientific studies in fields ranging from biology to semiconductor physics. However, commercially available scanning-probe instruments typically offer the ability to measure dynamics only on time scales of milliseconds to seconds. Here, we describe in detail the implementation of fast time-resolved electrostatic force microscopy using an oscillating cantilever as a means to measure fast local dynamics following a perturbation to a sample. We show how the phase of the oscillating cantilever relative to the perturbation event is critical to achieving reliable sub-cycle time resolution. We explore how noise affects the achievable time resolution and present empirical guidelines for reducing noise and optimizing experimental parameters. Specifically, we show that reducing the noise on the cantilever by using photothermal excitation instead of piezoacoustic excitation further improves time resolution. We demonstrate the discrimination of signal rise times with time constants as fast as 10 ns, and simultaneous data acquisition and analysis for dramatically improved image acquisition times.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A time-resolved, in-chamber x-ray pinhole imager for Z

We have commissioned a new time-resolved, x-ray imaging diagnostic for the Z facility. The primary intended application is for diagnosing the stagnation behavior of Magnetized Liner Inertial Fusion (MagLIF) and similar targets. We have a variety of imaging systems at Z, both time-integrated and time-resolved, that provide valuable x-ray imaging information, but no system at Z up to this time provides a combined high-resolution imaging with multi-frame time resolution; this new diagnostic, called TRICXI for Time Resolved In-Chamber X-ray Imager, is meant to provide time-resolved spatial imaging with high resolution. The multi-frame camera consists of a microchannel plate camera. A key component to achieving the design goals is to place the instrument inside the Z vacuum chamber within 2 m of the load, which necessitates a considerable amount of x-ray shielding as well as a specially designed, independent vacuum system. Here, a demonstration of the imaging capability for a series of MagLIF shots is presented. Predictions are given for resolution and relative image irradiance to guide experimenters in choosing the desired configuration for their experiments.

47 OTHER INSTRUMENTATION↗

Role of matrix elements in the time-resolved photoemission signal

Time- and angle-resolved photoemission spectroscopy (TR-ARPES) provides access to the ultrafast evolution of electrons andmany-body interactions in solid-state systems. However, themomentum- and energy-resolved transient photoemission intensitymay not be unambiguously described by the intrinsic relaxation dynamics of photoexcited electrons alone.The interpretation of the time-dependent photoemission signal can be affected by the transient evolution of the electronic distribution, and both the one-electron removal spectral function aswell as the photoemissionmatrix elements. Here we investigate the topological insulator Bi 1.1 Sb 0.9 Te 2 S to demonstrate, bymeans of a detailed probe-polarization dependent study, the transient contribution ofmatrix elements toTR-ARPES.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Detection of nonlinear picosecond acoustic pulses by time-resolved Brillouin scattering

In time-resolved Brillouin scattering (also called picosecond ultrasonic interferometry), the time evolution of the spatial Fourier component of an optically excited acoustic strain distribution is monitored. The wave number is determined by the momentum conservation in photon-phonon interaction. For linear acoustic waves propagating in a homogeneous medium, the detected time-domain signal of the optical probe transient reflectivity shows a sinusoidal oscillation at a constant frequency known as the Brillouin frequency. This oscillation is a result of heterodyning the constant reflection from the sample surface with the Brillouin-scattered field. Here, we present an analytical theory for the nonlinear reshaping of a propagating, finite amplitude picosecond acoustic pulse, which results in a time-dependence of the observed frequency. In particular, we examine the conditions under which this information can be used to study the time-evolution of the weak-shock front speed. Depending on the initial strain pulse parameters and the time interval of its nonlinear transformation, our theory predicts the detected frequency to either be monotonically decreasing or oscillating in time. We support these theoretical predictions by comparison with available experimental data. In general, we find that picosecond ultrasonic interferometry of nonlinear acoustic pulses provides access to the nonlinear acoustic properties of a medium spanning most of the GHz frequency range.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗