Search NASA⌕ Search

SEARCH · Search NASA

Results for “timing error evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Fast, automatic, and accurate catheter reconstruction in HDR brachytherapy using an electromagnetic 3D tracking system

Purpose: In high dose rate brachytherapy (HDR-B), current catheter reconstruction protocols are relatively slow and error prone. The purpose of this technical note is to evaluate the accuracy and the robustness of an electromagnetic (EM) tracking system for automated and real-time catheter reconstruction. Methods: For this preclinical study, a total of ten catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a 18G biopsy needle, used as an EM stylet and equipped with a miniaturized sensor, and the second generation Aurora{sup ®} Planar Field Generator from Northern Digital Inc. The Aurora EM system provides position and orientation value with precisions of 0.7 mm and 0.2°, respectively. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical computed tomography (CT) system with a spatial resolution of 89 μm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, five catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 s, leading to a total reconstruction time inferior to 3 min for a typical 17-catheter implant. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.66 ± 0.33 mm and 1.08 ± 0.72 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be more accurate. A maximum difference of less than 0.6 mm was found between successive EM reconstructions. Conclusions: The EM reconstruction was found to be more accurate and precise than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators.

60 APPLIED LIFE SCIENCES↗

Photoacoustic infrared spectroscopy for conducting gas tracer tests and measuring water saturations in landfills

Highlights: Black-Right-Pointing-Pointer Photoacoustic infrared spectroscopy tested for measuring tracer gas in landfills. Black-Right-Pointing-Pointer Measurement errors for tracer gases were 1-3% in landfill gas. Black-Right-Pointing-Pointer Background signals from landfill gas result in elevated limits of detection. Black-Right-Pointing-Pointer Technique is much less expensive and easier to use than GC. - Abstract: Gas tracer tests can be used to determine gas flow patterns within landfills, quantify volatile contaminant residence time, and measure water within refuse. While gas chromatography (GC) has been traditionally used to analyze gas tracers in refuse, photoacoustic spectroscopy (PAS) might allow real-time measurements with reduced personnel costs and greater mobility and ease of use. Laboratory and field experiments were conducted to evaluate the efficacy of PAS for conducting gas tracer tests in landfills. Two tracer gases, difluoromethane (DFM) and sulfur hexafluoride (SF{sub 6}), were measured with a commercial PAS instrument. Relative measurement errors were invariant with tracer concentration but influenced by background gas: errors were 1-3% in landfill gas but 4-5% in air. Two partitioning gas tracer tests were conducted in an aerobic landfill, and limits of detection (LODs) were 3-4 times larger for DFM with PAS versus GC due to temporal changes in background signals. While higher LODs can be compensated by injecting larger tracer mass, changes in background signals increased the uncertainty in measured water saturations by up to 25% over comparable GC methods. PAS has distinct advantages over GC with respect to personnel costs and ease of use, although for field applications GC analyses of select samples are recommended to quantify instrument interferences.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-G-207-06: 3D Fluoroscopic Image Generation From Patient-Specific 4DCBCT-Based Motion Models Derived From Physical Phantom and Clinical Patient Images

Purpose: Respiratory-correlated cone-beam CT (4DCBCT) images acquired immediately prior to treatment have the potential to represent patient motion patterns and anatomy during treatment, including both intra- and inter-fractional changes. We develop a method to generate patient-specific motion models based on 4DCBCT images acquired with existing clinical equipment and used to generate time varying volumetric images (3D fluoroscopic images) representing motion during treatment delivery. Methods: Motion models are derived by deformably registering each 4DCBCT phase to a reference phase, and performing principal component analysis (PCA) on the resulting displacement vector fields. 3D fluoroscopic images are estimated by optimizing the resulting PCA coefficients iteratively through comparison of the cone-beam projections simulating kV treatment imaging and digitally reconstructed radiographs generated from the motion model. Patient and physical phantom datasets are used to evaluate the method in terms of tumor localization error compared to manually defined ground truth positions. Results: 4DCBCT-based motion models were derived and used to generate 3D fluoroscopic images at treatment time. For the patient datasets, the average tumor localization error and the 95th percentile were 1.57 and 3.13 respectively in subsets of four patient datasets. For the physical phantom datasets, the average tumor localization error and the 95th percentile were 1.14 and 2.78 respectively in two datasets. 4DCBCT motion models are shown to perform well in the context of generating 3D fluoroscopic images due to their ability to reproduce anatomical changes at treatment time. Conclusion: This study showed the feasibility of deriving 4DCBCT-based motion models and using them to generate 3D fluoroscopic images at treatment time in real clinical settings. 4DCBCT-based motion models were found to account for the 3D non-rigid motion of the patient anatomy during treatment and have the potential to localize tumor and other patient anatomical structures at treatment time even when inter-fractional changes occur. This project was supported, in part, through a Master Research Agreement with Varian Medical Systems, Inc., Palo Alto, CA. The project was also supported, in part, by Award Number R21CA156068 from the National Cancer Institute.

60 APPLIED LIFE SCIENCES↗

Chapter 13: Assessing Persistence and Other Evaluation Issues Cross-Cutting Protocol. The Uniform Methods Project: Methods for Determining Energy Efficiency Savings for Specific Measures

Addressing other evaluation issues that have been raised in the context of energy efficiency programs, this chapter focuses on methods used to address the persistence of energy savings, which is an important input to the benefit/cost analysis of energy efficiency programs and portfolios. In addition to discussing 'persistence' (which refers to the stream of benefits over time from an energy efficiency measure or program), this chapter provides a summary treatment of these issues -Synergies across programs -Rebound -Dual baselines -Errors in variables (the measurement and/or accuracy of input variables to the evaluation).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Comparison of fluid-fluid interfacial areas measured with X-ray microtomography and interfacial partitioning tracer tests for the same samples

Two different methods are currently used for measuring interfacial areas between immiscible fluids within 3-D porous media, high-resolution microtomographic imaging and interfacial partitioning tracer tests (IPTT). Both methods were used in this study to measure nonwetting/wetting interfacial areas for a natural sand. The microtomographic imaging was conducted on the same packed columns that were used for the IPTTs. This is in contrast to prior studies comparing the two methods, for which in all cases different samples were used for the two methods. In addition, the columns were imaged before and after the IPTTs to evaluate the potential impacts of the tracer solution on fluid configuration and attendant interfacial area. The interfacial areas measured using IPTT are ~5 times larger than the microtomographic-measured values, which is consistent with previous work. Analysis of the image data revealed no significant impact of the tracer solution on NAPL configuration or interfacial area. Furthermore, other potential sources of error were evaluated, and all were demonstrated to be insignificant. The disparity in measured interfacial areas between the two methods is attributed to the limitation of the microtomography method to characterize interfacial area associated with microscopic surface roughness due to resolution constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BrachyView, A novel inbody imaging system for HDR prostate brachytherapy: Design and Monte Carlo feasibility study

Purpose: High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. In this paper, HDR BrachyView, a novel inbody dosimetric imaging system for real time monitoring and verification of the radioactive seed position in HDR prostate brachytherapy treatment is introduced. The current prototype consists of a 15 Multiplication-Sign 60 mm{sup 2} silicon pixel detector with a multipinhole tungsten collimator placed 6.5 mm above the detector. Seven identical pinholes allow full imaging coverage of the entire treatment volume. The combined pinhole and pixel sensor arrangement is geometrically designed to be able to resolve the three-dimensional location of the source. The probe may be rotated to keep the whole prostate within the transverse plane. The purpose of this paper is to demonstrate the efficacy of the design through computer simulation, and to estimate the accuracy in resolving the source position (in detector plane and in 3D space) as part of the feasibility study for the BrachyView project.Methods: Monte Carlo simulations were performed using the GEANT4 radiation transport model, with a {sup 192}Ir source placed in different locations within a prostate phantom. A geometrically accurate model of the detector and collimator were constructed. Simulations were conducted with a single pinhole to evaluate the pinhole design and the signal to background ratio obtained. Second, a pair of adjacent pinholes were simulated to evaluate the error in calculated source location.Results: Simulation results show that accurate determination of the true source position is easily obtainable within the typical one second source dwell time. The maximum error in the estimated projection position was found to be 0.95 mm in the imaging (detector) plane, resulting in a maximum source positioning estimation error of 1.48 mm.Conclusions: HDR BrachyView is a feasible design for real-time source tracking in HDR prostate brachytherapy. It is capable of resolving the source position within a subsecond dwell time. In combination with anatomical information obtained from transrectal ultrasound imaging, HDR BrachyView adds a significant quality assurance capability to HDR brachytherapy treatment systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Recovering noise-free quantum observables

We introduce a technique for recovering noise-free observables in noisy quantum systems by combining the results of many slightly different experiments. Our approach is applicable to a variety of quantum systems, but we illustrate it with applications to quantum information and quantum sensing. The approach corresponds to repeating the same quantum evolution many times with known variations on the underlying systems' error properties, e.g., the spontaneous emission and dephasing times $T_1$ and $T_2$. As opposed to standard quantum error correction methods, which have an overhead in the number of qubits (many physical qubits must be added for each logical qubit), our method has only an overhead in the number of evaluations, allowing the overhead to, in principle, be hidden via parallelization. We show that the effective spontaneous emission $T_1$ and dephasing $T_2$ times can be increased using this method in both simulation and experiments on an actual quantum computer. We also show how to correct more complicated entangled states and how Ramsey fringes relevant to quantum sensing can be significantly extended in time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bias in Dynamic Monte Carlo Alpha Calculations

A 1/N bias in the estimate of the neutron time-constant (commonly denoted as α) has been seen in dynamic neutronic calculations performed with MCATK. In this paper we show that the bias is most likely caused by taking the logarithm of a stochastic quantity. We also investigate the known bias due to the particle population control method used in MCATK. We conclude that this bias due to the particle population control method is negligible compared to other sources of bias.

42 ENGINEERING↗

Time-evolution methods for matrix-product states

Highlights: • Introductory review of time-evolution methods for matrix-product states. • Detailed description of five state-of-the-art algorithms. • Extended comparison of numerical examples. • Extended error analysis of each algorithm. • Pseudo-code examples towards an implementation where necessary. - Abstract: Matrix-product states have become the de facto standard for the representation of one-dimensional quantum many body states. During the last few years, numerous new methods have been introduced to evaluate the time evolution of a matrix-product state. Here, we will review and summarize the recent work on this topic as applied to finite quantum systems. We will explain and compare the different methods available to construct a time-evolved matrix-product state, namely the time-evolving block decimation, the MPO W{sup I,II} method, the global Krylov method, the local Krylov method and the one- and two-site time-dependent variational principle. We will also apply these methods to four different representative examples of current problem settings in condensed matter physics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying Diurnal Cloud Radiative Effects by Cloud Type in the Tropical Western Pacific

Cloud radiative effects are examined using long-term datasets collected at the three Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facilities in the tropical western Pacific. We quantify the surface radiation budget, cloud populations, and cloud radiative effects by partitioning the data by cloud type, time of day, and as a function of large scale modes of variability such as El Niño Southern Oscillation (ENSO) phase and wet/dry seasons at Darwin. The novel facet of our analysis is that we break aggregate cloud radiative effects down by cloud type across the diurnal cycle. The Nauru cloud populations and subsequently the surface radiation budget are strongly impacted by ENSO variability whereas the cloud populations over Manus only shift slightly in response to changes in ENSO phase. The Darwin site exhibits large seasonal monsoon related variations. We show that while deeper convective clouds have a strong conditional influence on the radiation reaching the surface, their limited frequency reduces their aggregate radiative impact. The largest source of shortwave cloud radiative effects at all three sites comes from low clouds. We use the observations to demonstrate that potential model biases in the amplitude of the diurnal cycle and mean cloud frequency would lead to larger errors in the surface energy budget compared to biases in the timing of the diurnal cycle of cloud frequency. Our results provide solid benchmarks to evaluate model simulations of cloud radiative effects in the tropics.

54 ENVIRONMENTAL SCIENCES↗

Fast Evaluation of Aircraft Icing Severity Using Machine Learning Based on XGBoost

Aircraft icing represents a serious hazard in aviation which has caused a number of fatal accidents over the years. In addition, it can lead to substantial increase in drag and weight, thus reducing the aerodynamics performance of the airplane. The process of ice accretion on a solid surface is a complex interaction of aerodynamic and environmental variables. The complex relationship makes machine learning-based methods an attractive alternative to traditional numerical simulation-based approaches. In this study, we introduce a purely data-driven approach to find the complex pattern between different flight conditions and aircraft icing severity prediction. The supervised learning algorithm Extreme Gradient Boosting (XGBoost) is applied to establish the prediction framework which makes prediction based on any set of observations. The input flight conditions for the proposed prediction framework are liquid water content, droplet diameter and exposure time. The proposed approach is demonstrated in three cases: maximum ice thickness prediction, icing area prediction and icing severity level evaluation. Performance comparison studies and error analysis are also conducted to verify the effectiveness and performance of the proposed method. Results show that the proposed method has reasonable capability in evaluating aircraft icing severity.

Li, Sibo (ORCID:000000021705844X)↗

YARNsim: Simulating Hadoop YARN

Despite the popularity of the Apache Hadoop system, its success has been limited by issues such as single points of failure, centralized job/task management, and lack of support for programming models other than MapReduce. The next generation of Hadoop, Apache Hadoop YARN, is designed to address these issues. In this paper, we propose YARNsim, a simulation system for Hadoop YARN. YARNsim is based on parallel discrete event simulation and provides protocol-level accuracy in simulating key components of YARN. YARNsim provides a virtual platform on which system architects can evaluate the design and implementation of Hadoop YARN systems. Also, application developers can tune job performance and understand the tradeoffs between different configurations, and Hadoop YARN system vendors can evaluate system efficiency under limited budgets. To demonstrate the validity of YARNsim, we use it to model two real systems and compare the experimental results from YARNsim and the real systems. The experiments include standard Hadoop benchmarks, synthetic workloads, and a bioinformatics application. The results show that the error rate is within 10% for the majority of test cases. The experiments prove that YARNsim can provide what-if analysis for system designers in a timely manner and at minimal cost compared with testing and evaluating on a real system.

Hadoop↗

Resilience Design Patterns: A Structured Approach to Resilience at Extreme Scale (V.2.0)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest the prevalence of very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Therefore, the resilience challenge for extreme-scale HPC systems requires coordination between various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. Also, due to practical limits on power consumption in future HPC systems, they are likely to embrace innovative architectures, increasing the levels of hardware and software complexities. Therefore, the techniques that seek to improve resilience must navigate the complex trade-off space between resilience and the overheads to power consumption and performance. While the HPC community has developed various resilience solutions, application-level techniques as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods to integrate the various HPC resilience techniques into composite solutions, nor are there methods to holistically evaluate the adequacy and efficacy of such solutions in terms of their protection coverage, and their performance & power efficiency characteristics. Additionally, few implementations of current resilience solutions are portable to newer architectures and software environments that will be deployed on future systems. We developed a new structured approach to the management of HPC resilience using the concept of resilience-based design patterns. In general, a design pattern is a repeatable solution to a commonly occurring problem. We identified the well-known solutions that are commonly used to deal with faults, errors and failures in HPC systems. In the initial design patterns specification (version 1.0), we described the various solutions, which address specific problems in the design of resilient HPC environments, in the form of patterns. Each pattern describes a problem caused by a fault, error or failure event in an HPC environment, and then describes the core of the solution of the problem in such a way that this solution may be adapted to different systems and implemented at different layers of the system stack. The catalog of these resilience design patterns provides designers with a collection of design elements. To construct complete resilience solutions using combinations of various patterns, we defined a framework that enhances HPC designers' understanding of the important constraints and the opportunities for the design patterns to be implemented and deployed at various layers of the system stack. The design framework is also useful for establishing interfaces and mechanisms to coordinate flexible fault management across hardware and software components, as well as to consider the trade-off between performance, resilience, and power consumption when constructing a solution. The resilience design patterns specification version 1.1 included more detailed explanations of the pattern solutions, the context in which the patterns are applicable, and the implications for hardware or software design. It also provided several additional examples and detailed case studies to demonstrate the use of patterns to build realistic solutions. In version 1.2 of the specification document, we have improved the pattern descriptions, including graphical representations of the pattern components. These improvements are largely based on critical comments, feedback and suggestions received from pattern experts and readers of the previous versions of the specification. The pattern classification has been modified to further clarify the relationships between pattern categories. This version of the specification also introduces a pattern language for resilience design patterns. The pattern language presents the patterns in the catalog as a network, revealing the relations among the resilience patterns. The language provides designers with the means to explore alternative techniques for handling a specific fault model that may have different efficiency and complexity characteristics. Using the pattern language also enables the design and implementation of comprehensive resilience solutions as a set of interconnected resilience patterns that can be instantiated across layers of the system stack. The overall goal of this work is to provide hardware and software designers, as well as the users and operators of HPC systems, a systematic methodology for the design and evaluation of resilience technologies in HPC systems that keep scientific applications running to a correct solution in a timely and cost-efficient manner despite frequent faults, errors, and failures of various types. Version 2.0 expands the resilience design pattern classification and catalog to include self-stabilization patterns and reliability, availability and performance models for each structural pattern.

97 MATHEMATICS AND COMPUTING↗

Resilience Design Patterns - A Structured Approach to Resilience at Extreme Scale (version 1.2)

We developed a new structured approach to the management of HPC resilience using the concept of resilience-based design patterns. In general, a design pattern is a repeatable solution to a commonly occurring problem. We identified the well-known solutions that are commonly used to deal with faults, errors and failures in HPC systems. In the initial design patterns specification (version 1.0), we described the various solutions, which address specific problems in the design of resilient HPC environments, in the form of patterns. Each pattern describes a problem caused by a fault, error or failure event in an HPC environment, and then describes the core of the solution of the problem in such a way that this solution may be adapted to different systems and implemented at different layers of the system stack. The catalog of these resilience design patterns provides designers with a collection of design elements. To construct complete resilience solutions using combinations of various patterns, we defined a framework that enhances HPC designers’ understanding of the important constraints and the opportunities for the design patterns to be implemented and deployed at various layers of the system stack. The design framework is also useful for establishing interfaces and mechanisms to coordinate flexible fault management across hardware and software components, as well as to consider the trade-off between performance, resilience, and power consumption when constructing a solution. The resilience design patterns specification version 1.1 included more detailed explanations of the pattern solutions, the context in which the patterns are applicable, and the implications for hardware or software design. It also provided several additional examples and detailed case studies to demonstrate the use of patterns to build realistic solutions. In this version 1.2 of the specification document, we have improved the pattern descriptions, including graphical representations of the pattern components. These improvements are largely based on critical comments, feedback and suggestions received from pattern experts and readers of the previous versions of the specification. The pattern classification has been modified to further clarify the relationships between pattern categories. This version of the specification also introduces a pattern language for resilience design patterns. The pattern language presents the patterns in the catalog as a network, revealing the relations among the resilience patterns. The language provides designers with the means to explore alternative techniques for handling a specific fault model that may have different effciency and complexity characteristics. Using the pattern language also enables the design and implementation of comprehensive resilience solutions as a set of interconnected resilience patterns that can be instantiated across layers of the system stack. The overall goal of this work is to provide hardware and software designers, as well as the users and operators of HPC systems, a systematic methodology for the design and evaluation of resilience technologies in HPC systems that keep scientific applications running to a correct solution in a timely and cost-effcient manner despite frequent faults, errors, and failures of various types.

97 MATHEMATICS AND COMPUTING↗

Resilience Design Patterns - A Structured Approach to Resilience at Extreme Scale (version 1.0)

Reliability is a serious concern for future extreme-scale high-performance computing (HPC) systems. Projections based on the current generation of HPC systems and technology roadmaps suggest that very high fault rates in future systems. The errors resulting from these faults will propagate and generate various kinds of failures, which may result in outcomes ranging from result corruptions to catastrophic application crashes. Practical limits on power consumption in HPC systems will require future systems to embrace innovative architectures, increasing the levels of hardware and software complexities. The resilience challenge for extreme-scale HPC systems requires management of various hardware and software technologies that are capable of handling a broad set of fault models at accelerated fault rates. These techniques must seek to improve resilience at reasonable overheads to power consumption and performance. While the HPC community has developed various solutions, application-level as well as system-based solutions, the solution space of HPC resilience techniques remains fragmented. There are no formal methods and metrics to investigate and evaluate resilience holistically in HPC systems that consider impact scope, handling coverage, and performance & power eciency across the system stack. Additionally, few of the current approaches are portable to newer architectures and software ecosystems, which are expected to be deployed on future systems. In this document, we develop a structured approach to the management of HPC resilience based on the concept of resilience-based design patterns. A design pattern is a general repeatable solution to a commonly occurring problem. We identify the commonly occurring problems and solutions used to deal with faults, errors and failures in HPC systems. The catalog of resilience design patterns provides designers with reusable design elements. We define a design framework that enhances our understanding of the important constraints and opportunities for solutions deployed at various layers of the system stack. The framework may be used to establish mechanisms and interfaces to coordinate flexible fault management across hardware and software components. The framework also enables optimization of the cost-benefit trade-os among performance, resilience, and power consumption. The overall goal of this work is to enable a systematic methodology for the design and evaluation of resilience technologies in extreme-scale HPC systems that keep scientific applications running to a correct solution in a timely and cost-ecient manner in spite of frequent faults, errors, and failures of various types.

97 MATHEMATICS AND COMPUTING↗

Quality and accuracy of cone beam computed tomography gated by active breathing control

The purpose of this study was to evaluate the quality and accuracy of cone beam computed tomography (CBCT) gated by active breathing control (ABC), which may be useful for image guidance in the presence of respiration. Comparisons were made between conventional ABC-CBCT (stop and go), fast ABC-CBCT (a method to speed up the acquisition by slowing the gantry instead of stopping during free breathing), and free breathing respiration correlated CBCT. Image quality was assessed in phantom. Accuracy of reconstructed voxel intensity, uniformity, and root mean square error were evaluated. Registration accuracy (bony and soft tissue) was quantified with both an anthropomorphic and a quality assurance phantom. Gantry angle accuracy was measured with respect to gantry speed modulation. Conventional ABC-CBCT scan time ranged from 2.3 to 5.8 min. Fast ABC-CBCT scan time ranged from 1.4 to 1.8 min, and respiratory correlated CBCT scans took 2.1 min to complete. Voxel intensity value for ABC gated scans was accurate relative to a normal clinical scan with all projections. Uniformity and root mean square error performance degraded as the number of projections used in the reconstruction of the fast ABC-CBCT scans decreased (shortest breath hold, longest free breathing segment). Registration accuracy for small, large, and rotational corrections was within 1 mm and 1 degree sign . Gantry angle accuracy was within 1 degree sign for all scans. For high-contrast targets, performance for image-guidance purposes was similar for fast and conventional ABC-CBCT scans and respiration correlated CBCT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Generating data ensembles over a model grid from sparse climate measurements.

Parameterizations in high-end climate models can be evaluated with observed climate and meteorological data. Often this evaluation is achieved by averaging measured quantities over time and space to match the spatial and temporal resolution of a gridded climate model without any regard for the statistical errors in doing so. We present a statistical method to interpolate sparsely located surface measurements into a uniform spatial grid representative of global and regional models of the atmosphere and climate. This method provides estimates of mean values over the entire domain containing the measurement sites as well as the uncertainty in the estimated quantities at the grid locations through multiple simulations to create 'data ensembles.' We demonstrate this method using measurements of surface sensible heat flux over the southern Great Plains region gathered through the Department of Energy's Atmospheric Radiation Measurement (ARM) program. Application to the numerous other climate variables measured through the ARM program and the development of a software tool to streamline data management and implementation of the statistical models is also discussed.

54 ENVIRONMENTAL SCIENCES↗