Search NASA⌕ Search

SEARCH · Search NASA

Results for “tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Deep-learning methods for contrast enhancement and artifact reduction in cryo-electron tomography: a systematic analysis of the state of the art and proposed improvements

Cryo-electron tomography (cryo-ET) has emerged as the preferred technique for visualizing the organization of macromolecular complexes in situ and resolving their structures at subnanometre resolution [Tegunov et al. (2021)View full citation, Nat. Methods, 18, 186–193]. Despite improvements in data quality as a result of advances in detector technology, microscope stability and stage precision, the analysis and interpretation of tomograms remains challenging due to a low signal-to-noise ratio and reconstruction artifacts stemming from experimental constraints in specimen tilt during data collection resulting in a missing wedge in the Fourier space. Recently, self-supervised deep-learning methods have been proposed for contrast enhancement and reduction of resolution anisotropy in reconstructed tomograms. Here, we evaluate several state-of-the-art deep-learning methods which aim to improve the interpretability of cryo-ET reconstructions, with a focus on their performance on downstream tasks of template matching, sub­tomogram averaging and segmentation. We propose new training architectures and a loss function based on Fourier shell correlation that show improved performance over the standard U-Net with L1/L2 losses. We demonstrate our analysis on four diverse experimental datasets: purified 80S ribosomes, in situ Chlamydomonas reinhardtii, immature HIV-1 virus-like particles and INS-1E cells.

contrast enhancement↗

Composition Quantification of SiGeSn Alloys Through Time-of-Flight Secondary Ion Mass Spectrometry: Calibration Methodologies and Validation With Atom Probe Tomography

Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) is a powerful technique for elemental compositional analysis and depth profiling of materials. However, it encounters the problem of matrix effects that hinder its application. In this work, we introduce a pioneering ToF-SIMS calibration method tailored for SixGeySnz ternary alloys. SixGe1-x and Ge1-zSnz binary alloys with known compositions are used as calibration reference samples. Through a systematic SIMS quantification study of SiGe and GeSn binary alloys, we unveil a linear correlation between secondary ion intensity ratio and composition ratio for both SiGe and GeSn binary alloys, effectively mitigating the matrix effects. Extracted relative sensitivity factor (RSF) value from SixGe1-x (0.07 < x < 0.83) and Ge1-zSnz (0.066 < z < 0.183) binary alloys are subsequently applied to those of SixGeySnz (0.011 < x < 0.113, 0.863 < y < 0.935 and 0.023 < z < 0.103) ternary alloys for elemental compositions quantification. These values are cross-checked by Atom Probe Tomography (APT) analysis, an indication of the great accuracy and reliability of as-developed ToF-SIMS calibration process. Furthermore, the proposed method and its reference sample selection strategy in this work provide a low-cost as well as simple-to-follow calibration route for SiGeSn composition analysis, thus driving the development of next-generation multifunctional SiGeSn-related semiconductor devices.

36 MATERIALS SCIENCE↗

Quantitative phenotyping of crop roots with spectral electrical impedance tomography: a rhizotron study with optimized measurement design

Background: Root systems are key contributors to plant health, resilience, and, ultimately, yield of agricultural crops. To optimize plant performance, phenotyping trials are conducted to breed plants with diverse root traits. However, traditional analysis methods are often labour-intensive and invasive to the root system, therefore limiting high-throughput phenotyping. Spectral electrical impedance tomography (sEIT) could help as a non-invasive and cost-efficient alternative to optical root analysis, potentially providing 2D or 3D spatio-temporal information on root development and activity. Although impedance measurements have been shown to be sensitive to root biomass, nutrient status, and diurnal activity, only few attempts have been made to employ tomographic algorithms to recover spatially resolved information on root systems. In this study, we aim to establish relationships between tomographic electrical polarization signatures and root traits of different fine root systems (maize, pinto bean, black bean, and soy bean) under hydroponic conditions. Results: Our results show that, with the use of an optimized data acquisition scheme, sEIT is capable of providing spatially resolved information on root biomass and root surface area for all investigated root systems. We found strong correlations between the total polarization strength and the root biomass (R 2 = 0.82) and root surface area (R 2 = 0.8). Our findings suggest that the captured polarization signature is dominated by cell-scale polarization processes. Additionally, we demonstrate that the resolution characteristics of the measurement scheme can have a significant impact on the tomographic reconstruction of root traits. Conclusion: Our findings showcase that sEIT is a promising tool for the tomographic reconstruction of root traits in high-throughput root phenotyping trials and should be evaluated as a substitute for traditional, often time-consuming, root characterization methods.

59 BASIC BIOLOGICAL SCIENCES↗

Electrical Resistivity Tomography data from 2016 to 2018 at the Lower Montane site in the East River Watershed, Colorado

This dataset contains time-lapse Electrical Resistivity Tomography (ERT) data along a transect located on the northeast-facing hillslope at the lower montane site (Pumphouse site) in the upper East River Watershed. The monitoring dataset covers the period from November 2, 2016, to August 6, 2018. In addition, the archive also contains a baseline dataset from October 9, 2016. The ERT transect consisted of 128 electrodes with an electrode spacing of 1.25 m. The acquisition system was located in the middle of the transect, about 50 m on one side, and included an MPT (Multi-Phase Technologies) ERT system, a mini computer, and batteries with solar panels. Acquisition occurred daily under normal circumstances. The first 16 electrodes (from the upper end of the transect) could not be used after the cable was damaged during the 2017–2018 winter. Also, due to multiple failures in the power system, the temporal resolution of the data is much lower in 2018 compared to 2016 and 2017. The data have been processed and used in Dafflon et al., 2023, and the baseline dataset was used in Falco et al., 2019 (see reference list). This archive contains the measurements (ER.zip containing csv files) for each of the 326 acquisition times and a filtered version where only electrodes 17 to 128 are included (ERT_sm.zip containing csv files). The archive also contains the baseline dataset and two acquisitions with full reciprocals (ERT_RB.zip containing csv files), as well as all the raw MPT files (ERT_raw_MTP.zip). The geometry (electrode position and elevation) is provided in Universal Transverse Mercator (UTM) 13N Geoid2012AB in the file named ERT_Location.csv. The archive contains 1 *.csv data files, four *.zip files, and three metadata *.csv files. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Clinton Formation in Ohio

Computed tomography and multi-sensor core logging of core material from twelve Ohio wells held by the Ohio Department of Natural Resources, Division of Geological Survey to make publicly available core information from the Early Silurian Clinton Formation in Eastern Ohio. Describes data available can be accessed from NETL’s Energy Data eXchange (EDX) online system, https://edx.netl.doe.gov/dataset/ct-and-geophysical-data-of-ohio-clinton-sands.

58 GEOSCIENCES↗

Development of Automated Atom Probe Tomography capability to study the influence of applied voltage and laser power on the final apparent composition of the analyzed specimen

This study presents the development and implementation of an autonomous Bayesian optimization (BO) framework for controlling and optimizing experimental parameters in Atom Probe Tomography (APT). Using commercial silicon needle samples as a benchmark system, we demonstrate that BO can efficiently navigate the complex parameter space of voltage and laser power to achieve target charge state ratios (specifically Si + /(Si + +Si 2+ )) with minimal experimental evaluations. Our implementation integrates Gaussian Process modeling with the CAMECA atom probe control framework, enabling autonomous adjustment of experimental conditions in real-time. Results show that the algorithm successfully converges to target ratios under different scenarios: maintaining a reference ratio, increasing the ratio (favoring Si 1+ ), and decreasing the ratio (favoring Si 2+ ). The system adapts to specimen evolution during analysis, compensating for changes in apex geometry while maintaining optimization targets. This work establishes a proof of concept for AI-driven optimization in APT, addressing the traditional challenges of manual parameter tuning and paving the way for applications to more complex materials where compositional accuracy is critical.

36 MATERIALS SCIENCE↗

Identifying the Accuracy of Surface Roughness for Metal Additive Manufacturing Parts Captured with Computed Tomography Scanning

Conventional surface roughness measurement techniques require direct access to internal surfaces, often necessitating destructive sectioning of test articles. Computed tomography (CT) offers a non-destructive alternative for internal surface characterization, but its application in metrology remains unstandardized and sensitive to machine resolution and operator technique. This study investigates the feasibility of using CT scanning to quantify areal surface roughness in metal AM heat exchanger tubes with three distinct internal geometries: ribbed, discrete W, and featureless. CT-derived surface parameters were extracted using custom Python scripts and compared to measurements obtained from a focus variation microscope calibrated against a known standard. Results show that CT-based roughness measurements closely matched microscope values for the discrete W specimen, deviations between CT and microscope measurements were minimal—less than 1 µm—indicating reliable reconstruction. In contrast, the ribbed and featureless specimens, with lower roughness values showed greater discrepancies. The findings suggest that CT scanning can be a viable non-destructive metrology tool for AM parts with surface roughness above approximately 8 µm. For smoother surfaces, current CT capabilities may not provide sufficient accuracy, highlighting the need for resolution-aware workflows and further standardization in CT-based surface metrology.

36 MATERIALS SCIENCE↗

Universal framework for simultaneous tomography of quantum states and SPAM noise

We present a general denoising algorithm for performing simultaneous tomography of quantum states and measurement noise. This algorithm allows us to fully characterize state preparation and measurement (SPAM) errors present in any quantum system. Our method is based on the analysis of the properties of the linear operator space induced by unitary operations. Given any quantum system with a noisy measurement apparatus, our method can output the quantum state and the noise matrix of the detector up to a single gauge degree of freedom. We show that this gauge freedom is unavoidable in the general case, but this degeneracy can be generally broken using prior knowledge on the state or noise properties, thus fixing the gauge for several types of state-noise combinations with no assumptions about noise strength. Such combinations include pure quantum states with arbitrarily correlated errors, and arbitrary states with block independent errors. This framework can further use available prior information about the setting to systematically reduce the number of observations and measurements required for state and noise detection. Our method effectively generalizes existing approaches to the problem, and includes as special cases common settings considered in the literature requiring an uncorrelated or invertible noise matrix, or specific probe states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Defect And Damage Characterization Of Additively Manufactured Titanium Alloy Ti-5553 Using Traditional Computed Tomography Volume Segmentation And Machine Learning Algorithms

The mechanical response of a component is affected by defects, such as porosity, arising from the laser powder bed fusion (LPBF) fabrication process. Thus, it is important to develop accurate and efficient inspection methods for identifying porosity. In this work, porosity identified in an X-ray computed tomography (XCT) volume of a Ti-5553 coupon was compared to pores identified in a serial sectioned volume that represented the ground truth. The porosity of the XCT scan was identified using contrast-based, ISO-based, and machine learning (ML) methods for segmentation. Large inherent porosity was easy to identify, but the ISO thresholding still struggled due to the intensity gradient resulting from both the beam hardening in XCT and the uneven lighting of the serial sectioning panels. Further, the results show that ML-based methods were better suited for identifying small pores and reducing the amount of false positives. Additionally, high strain-rate impact testing was done on some of the XCT samples as well as post-mortem XCT inspection, and the same suite of segmentation and quantification tools were used to identify the large spallation cavities. The comparison of porosity pre- and post-mortem provides insight on the influence of the LPBF porosity on the formation of spall cavities.

36 MATERIALS SCIENCE↗

Quantitative Analysis of Rhodobacter sphaeroides Storage Organelles via Cryo-Electron Tomography and Light Microscopy

Bacterial cytoplasmic organelles are diverse and serve many varied purposes. Here, we employed Rhodobacter sphaeroides to investigate the accumulation of carbon and inorganic phosphate in the storage organelles, polyhydroxybutyrate (PHB) and polyphosphate (PP), respectively. Using cryo-electron tomography (cryo-ET), these organelles were observed to increase in size and abundance when growth was arrested by chloramphenicol treatment. The accumulation of PHB and PP was quantified from three-dimensional (3D) segmentations in cryo-tomograms and the analysis of these 3D models. The quantification of PHB using both segmentation analysis and liquid chromatography and mass spectrometry (LCMS) each demonstrated an over 10- to 20-fold accumulation of PHB. The cytoplasmic location of PHB in cells was assessed with fluorescence light microscopy using a PhaP-mNeonGreen fusion-protein construct. The subcellular location and enumeration of these organelles were correlated by comparing the cryo-ET and fluorescence microscopy data. A potential link between PHB and PP localization and possible explanations for co-localization are discussed. Finally, the study of PHB and PP granules, and their accumulation, is discussed in the context of advancing fundamental knowledge about bacterial stress response, the study of renewable sources of bioplastics, and highly energetic compounds.

59 BASIC BIOLOGICAL SCIENCES↗

Subcellular Feature-Based Classification of α and β Cells Using Soft X-ray Tomography

The dysfunction of α and β cells in pancreatic islets can lead to diabetes. Many questions remain on the subcellular organization of islet cells during the progression of disease. Existing three-dimensional cellular mapping approaches face challenges such as time-intensive sample sectioning and subjective cellular identification. To address these challenges, we have developed a subcellular feature-based classification approach, which allows us to identify α and β cells and quantify their subcellular structural characteristics using soft X-ray tomography (SXT). We observed significant differences in whole-cell morphological and organelle statistics between the two cell types. Additionally, we characterize subtle biophysical differences between individual insulin and glucagon vesicles by analyzing vesicle size and molecular density distributions, which were not previously possible using other methods. These sub-vesicular parameters enable us to predict cell types systematically using supervised machine learning. We also visualize distinct vesicle and cell subtypes using Uniform Manifold Approximation and Projection (UMAP) embeddings, which provides us with an innovative approach to explore structural heterogeneity in islet cells. This methodology presents an innovative approach for tracking biologically meaningful heterogeneity in cells that can be applied to any cellular system.

3D cell mapping↗

Acoustic Tomography of the Atmosphere: A Large-Eddy Simulation Sensitivity Study

Accurate measurement of atmospheric turbulent fluctuations is critical for understanding environmental dynamics and improving models in applications such as wind energy. Advanced remote sensing technologies are essential for capturing instantaneous velocity and temperature fluctuations. Acoustic tomography (AT) offers a promising approach that utilizes sound travel times between an array of transducers to reconstruct turbulence fields. This study presents a systematic evaluation of the time-dependent stochastic inversion (TDSI) algorithm for AT using synthetic travel-time measurements derived from large-eddy simulation (LES) fields under both neutral and convective atmospheric boundary-layer conditions. Unlike prior work that relied on field observations or idealized fields, the LES framework provides a ground-truth atmospheric state, enabling quantitative assessment of TDSI retrieval reliability, sensitivity to travel-time measurement noise, and dependence on covariance model parameters and temporal data integration. A detailed sensitivity analysis was conducted to determine the best-fit model parameters, identify the tolerance thresholds for parameter mismatch, and establish a maximum spatial resolution. The TDSI algorithm successfully reconstructed large-scale velocity and temperature fluctuations with root mean square errors ( RMSE s) below 0.35 m/s and 0.12 K, respectively. Spectral analysis established a maximum spatial resolution of approximately 1.4 m, and reconstructions remained robust for travel-time measurement uncertainties up to 0.002 s. These findings provide critical insights into the operational limits of TDSI and inform future applications of AT for atmospheric turbulence characterization and system design.

17 WIND ENERGY↗

Structural relations between collagen and mineral in bone as determined by high voltage electron microscopic tomography

Aspects of the ultrastructural interaction between collagen and mineral crystals in embryonic chick bone have been examined by the novel technique of high voltage electron microscopic tomography to obtain three-dimensional information concerning extracellular calcification in this tissue. Newly mineralizing osteoid along periosteal surfaces of mid-diaphyseal regions from normal chick tibiae was embedded, cut into 0.25 microns thick sections, and documented at 1.0 MV in the Albany AEI-EM7 high voltage electron microscope. The areas of the tissue studied contained electron dense mineral crystals associated with collagen fibrils, some marked by crystals disposed along their cylindrically shaped lengths. Tomographic reconstructions of one site with two mineralizing fibrils were computed from a 5 degrees tilt series of micrographs over a +/- 60 degrees range. Reconstructions showed that the mineral crystals were platelets of irregular shape. Their sizes were variable, measured here up to 80 x 30 x 8 nm in length, width, and thickness, respectively. The longest crystal dimension, corresponding to the c-axis crystallographically, was generally parallel to the collagen fibril long axis. Individual crystals were oriented parallel to one another in each fibril examined. They were also parallel in the neighboring but apparently spatially separate fibrils. Crystals were periodically (approximately 67 nm repeat distance) arranged along the fibrils and their location appeared to correspond to collagen hole and overlap zones defined by geometrical imaging techniques. The crystals appeared to be continuously distributed along a fibril, their size and number increasing in a tapered fashion from a relatively narrow tip containing smaller and infrequent crystals to wider regions having more densely packed and larger crystals. Defined for the first time by direct visual 3D imaging, these data describe the size, shape, location, orientation, and development of early crystals in normal bone collagen. The results suggest that platelet-shaped crystals are arranged in channels or grooves which are formed by collagen hole zones in register and that crystal sizes may exceed the dimensions of hole zones. Such data agree with those from mineral-matrix interaction in normally calcifying avian tendon obtained by similar high voltage tomographic means, but in addition they indicate a possible gradual and continuous deposition of crystals in collagen of bone unlike tendon and imply that individual collagen fibrils in local regions of osteoid are organized such that they all may be aligned in a coherent manner.

NASA Discipline Number 40-40↗

Electrical Capacitance Volume Tomography for the Packed Bed Reactor ISS Flight Experiment

Fixed packed bed reactors are compact, require minimum power and maintenance to operate, and are highly reliable. These features make this technology a highly desirable unit operation for long duration life support systems in space. NASA is developing an ISS experiment to address this technology with particular focus on water reclamation and air revitalization. Earlier research and development efforts funded by NASA have resulted in two hydrodynamic models which require validation with appropriate instrumentation in an extended microgravity environment. To validate these models, the instantaneous distribution of the gas and liquid phases must be measured.Electrical Capacitance Volume Tomography (ECVT) is a non-invasive imaging technology recently developed for multi-phase flow applications. It is based on distributing flexible capacitance plates on the peripheral of a flow column and collecting real-time measurements of inter-electrode capacitances. Capacitance measurements here are directly related to dielectric constant distribution, a physical property that is also related to material distribution in the imaging domain. Reconstruction algorithms are employed to map volume images of dielectric distribution in the imaging domain, which is in turn related to phase distribution. ECVT is suitable for imaging interacting materials of different dielectric constants, typical in multi-phase flow systems. ECVT is being used extensively for measuring flow variables in various gas-liquid and gas-solid flow systems. Recent application of ECVT include flows in risers and exit regions of circulating fluidized beds, gas-liquid and gas-solid bubble columns, trickle beds, and slurry bubble columns. ECVT is also used to validate flow models and CFD simulations. The technology is uniquely qualified for imaging phase concentrations in packed bed reactors for the ISS flight experiments as it exhibits favorable features of compact size, low profile sensors, high imaging speed, and flexibility to fit around columns of various shapes and sizes. ECVT is also safer than other commonly used imaging modalities as it operates in the range of low frequencies (1 MHz) and does not radiate radioactive energy. In this effort, ECVT is being used to image flow parameters in a packed bed reactor for an ISS flight experiment.

Tomography↗

X-Ray Computed Tomography of Tranquility Base Moon Rock

X-ray Computed Tomography (CT) was used for the first time on the Apollo 11 Lunar Sample number 10057.30, which had been previously maintained by the White House, then transferred back to NASA under the care of Goddard Space Flight Center. Results from this analysis show detailed images of the internal structure of the moon rock, including vesicles (pores), crystal needles, and crystal bundles. These crystals, possibly the common mineral ilmenite, are found in abundance and with random orientation. Future work, in particular a greater understanding of these crystals and their formation, may lead to a more in-depth understanding of the lunar surface evolution and mineral content.

X-ray computed tomography↗