Search NASA⌕ Search

SEARCH · Search NASA

Results for “torso”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Crash Test of an MD-500 Helicopter with a Deployable Energy Absorber Concept

On December 2, 2009, a full scale crash test was successfully conducted of a MD-500 helicopter at the NASA Langley Research Center Landing and Impact Research Facility . The purpose of this test was to evaluate a novel composite honeycomb deployable energy absorbing (DEA) concept for attenuation of structural and crew loads during helicopter crashes under realistic crash conditions. The DEA concept is an alternative to external airbags, and absorbs impact energy through crushing. In the test, the helicopter impacted the concrete surface with 11.83 m/s (38.8 ft/s) horizontal, 7.80 m/s (25.6 ft/s) vertical and 0.15 m/s (0.5 ft/s) lateral velocities; corresponding to a resultant velocity of 14.2 m/s (46.5 ft/s). The airframe and skid gear were instrumented with accelerometers and strain gages to determine structural integrity and load attenuation, while the skin of the airframe was covered with targets for use by photogrammetry to record gross vehicle motion before, during, and after the impact. Along with the collection of airframe data, one Hybrid III 50th percentile anthropomorphic test device (ATD), two Hybrid II 50th percentile ATDs and a specialized human surrogate torso model (HSTM) occupant were seated in the airframe and instrumented for the collection of occupant loads. Resultant occupant data showed that by using the DEA, the loads on the Hybrid II and Hybrid III ATDs were in the Low Risk regime for the injury criteria, while structural data showed the airframe retained its structural integrity post crash. Preliminary results show that the DEA is a viable concept for the attenuation of impact loads.

Littell, Justin D.↗

Optimization of Stimulus Characteristics for Vestibular Stochastic Resonance to Improve Balance Function

Stochastic resonance (SR) is a mechanism by which noise can assist and enhance the response of neural systems to relevant sensory signals. Recent studies have shown that applying imperceptible stochastic noise electrical stimulation to the vestibular system significantly improved balance and ocular motor responses. The goal of this study was to optimize the amplitude of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standardized balance task of standing on a block of 10-cm-thick medium-density foam with their eyes closed. Balance performance was measured using a force plate under the foam block and using inertial motion sensors placed on the torso and head segments. Stochastic electrical stimulation was applied to the vestibular system through electrodes placed over the mastoid process. Subjects were tested at seven amplitudes in the 0.01-30Hz frequency range. The root mean square of the signal increased by 30 microamperes for each +/-100 microampere increment in the current range of 0 - +/-700 microampere. Six balance parameters were calculated to characterize the performance of subjects during the baseline and the stimulus periods for all seven amplitudes. Optimal stimulus amplitude was determined as the one at which the ratio of parameters from the stimulus period to the baseline period for any amplitude range was less than that for the no stimulus condition on a minimum of four of six parameters. Results from this study showed that balance performance at the optimal stimulus amplitude showed significant improvement with the application of the vestibular SR stimulation. The amplitude of optimal stimulus for improving balance performance in normal subjects was in the range of +/-100 - +/-300 microamps.

Mulavara, Ajitkumar↗

Visual Bias Predicts Gait Adaptability in Novel Sensory Discordant Conditions

We designed a gait training study that presented combinations of visual flow and support-surface manipulations to investigate the response of healthy adults to novel discordant sensorimotor conditions. We aimed to determine whether a relationship existed between subjects visual dependence and their postural stability and cognitive performance in a new discordant environment presented at the conclusion of training (Transfer Test). Our training system comprised a treadmill placed on a motion base facing a virtual visual scene that provided a variety of sensory challenges. Ten healthy adults completed 3 training sessions during which they walked on a treadmill at 1.1 m/s while receiving discordant support-surface and visual manipulations. At the first visit, in an analysis of normalized torso translation measured in a scene-movement-only condition, 3 of 10 subjects were classified as visually dependent. During the Transfer Test, all participants received a 2-minute novel exposure. In a combined measure of stride frequency and reaction time, the non-visually dependent subjects showed improved adaptation on the Transfer Test compared to their visually dependent counterparts. This finding suggests that individual differences in the ability to adapt to new sensorimotor conditions may be explained by individuals innate sensory biases. An accurate preflight assessment of crewmembers biases for visual dependence could be used to predict their propensities to adapt to novel sensory conditions. It may also facilitate the development of customized training regimens that could expedite adaptation to alternate gravitational environments.

Brady, Rachel A.↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were off-loaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason R.↗

Preliminary Results of the Effect of Microgravity on Seated Height

The new vehicle for future space travel to the International Space Station (ISS) and beyond will be highly dependent on the seat layout. A primary concern with the seat layout design of the new vehicle is the amount of seated height growth that occurs in space; this could cause a major accommodation issue. The design of the seats, seat layout, suit fit, and crew accommodation are all critically affected due to the increase in height that occurs in microgravity. The increase in height due to spinal elongation caused by the absence of gravity could lead to inadequate clearances that would have implications for the ability of crewmembers to return safely or to conduct nominal operations during the mission. This study was designed to reduce the risk of inadequate design of the vehicle, environment, tools, equipment, etc. (SHFE risk 2.3.1.1) and safely return crewmembers to earth from low-earth orbit travel, ISS, and beyond. In order to safely return the crewmembers, the design requirements must anticipate microgravity growth, elongation of the spine, bone and muscle loss, fluid shifts, etc. Thus, this study is to determine the amount of torso growth (spinal elongation) for a seated posture during Shuttle and ISS missions. Crewmembers seated heights were collected before, during, and after spaceflight to quantify the amount of growth that occurred as a result of microgravity. The changes in seated height will provide the designers with a design requirement which allows for change in spinal growth for a seated posture. Preliminary results have shown that , during flight, seated height increases by a range of approximately 2-6 percent compared to pre-launch seated height.

Rajulu, Sudhakar↗

Stimulus Characteristics for Vestibular Stochastic Resonance to Improve Balance Function

Stochastic resonance (SR) is a mechanism by which noise can enhance the response of neural systems to relevant sensory signals. Studies have shown that imperceptible stochastic vestibular electrical stimulation, when applied to normal young and elderly subjects, significantly improved their ocular stabilization reflexes in response to whole-body tilt as well as balance performance during postural disturbances. The goal of this study was to optimize the amplitude characteristics of the stochastic vestibular signals for balance performance during standing on an unstable surface. Subjects performed a standard balance task of standing on a block of foam with their eyes closed. Bipolar stochastic electrical stimulation was applied to the vestibular system using constant current stimulation through electrodes placed over the mastoid process behind the ears. Amplitude of the signals varied in the range of 0-700 microamperes. Balance performance was measured using a force plate under the foam block, and inertial motion sensors were placed on the torso and head. Balance performance with stimulation was significantly greater (10%-25%) than with no stimulation. The signal amplitude at which performance was maximized was in the range of 100-300 microamperes. Optimization of the amplitude of the stochastic signals for maximizing balance performance will have a significant impact on development of vestibular SR as a unique system to aid recovery of function in astronauts after long-duration space flight or in patients with balance disorders.

Mulavara, Ajitkumar↗

Robonaut 2 - The First Humanoid Robot in Space

NASA and General Motors have developed the second generation Robonaut, Robonaut 2 or R2, and it is scheduled to arrive on the International Space Station in late 2010 and undergo initial testing in early 2011. This state of the art, dexterous, anthropomorphic robotic torso has significant technical improvements over its predecessor making it a far more valuable tool for astronauts. Upgrades include: increased force sensing, greater range of motion, higher bandwidth and improved dexterity. R2 s integrated mechatronics design results in a more compact and robust distributed control system with a faction of the wiring of the original Robonaut. Modularity is prevalent throughout the hardware and software along with innovative and layered approaches for sensing and control. The most important aspects of the Robonaut philosophy are clearly present in this latest model s ability to allow comfortable human interaction and in its design to perform significant work using the same hardware and interfaces used by people. The following describes the mechanisms, integrated electronics, control strategies and user interface that make R2 a promising addition to the Space Station and other environments where humanoid robots can assist people.

Diftler, M. A.↗

Tactile Cueing as a Gravitational Substitute for Spatial Navigation During Parabolic Flight

INTRODUCTION: Spatial navigation requires an accurate awareness of orientation in your environment. The purpose of this experiment was to examine how spatial awareness was impaired with changing gravitational cues during parabolic flight, and the extent to which vibrotactile feedback of orientation could be used to help improve performance. METHODS: Six subjects were restrained in a chair tilted relative to the plane floor, and placed at random positions during the start of the microgravity phase. Subjects reported their orientation using verbal reports, and used a hand-held controller to point to a desired target location presented using a virtual reality video mask. This task was repeated with and without constant tactile cueing of "down" direction using a belt of 8 tactors placed around the mid-torso. Control measures were obtained during ground testing using both upright and tilted conditions. RESULTS: Perceptual estimates of orientation and pointing accuracy were impaired during microgravity or during rotation about an upright axis in 1g. The amount of error was proportional to the amount of chair displacement. Perceptual errors were reduced during movement about a tilted axis on earth. CONCLUSIONS: Reduced perceptual errors during tilts in 1g indicate the importance of otolith and somatosensory cues for maintaining spatial awareness. Tactile cueing may improve navigation in operational environments or clinical populations, providing a non-visual non-auditory feedback of orientation or desired direction heading.

Montgomery, K. L.↗

Radiation Transport Modeling and Assessment to Better Predict Radiation Exposure, Dose, and Toxicological Effects to Human Organs on Long Duration Space Flights

NASA's long-range plans include possible human exploratory missions to the moon and Mars within the next quarter century. Such missions beyond low Earth orbit will expose crews to transient radiation from solar particle events which include high-energy galactic cosmic rays and high-energy protons. Because the radiation levels in space are high and the missions long, adequate shielding is needed to minimize the deleterious health effects of exposure to radiation. The focus of this study is radiation exposure to the blood-forming organs of the NASA astronauts. NASA/JSC developed the Phantom Torso Experiment for Organ Dose Measurements which housed active and passive dosimeters that would monitor and record absorbed radiation levels at vital organ locations. This experiment was conducted during the STS-9 I mission in May '98 and provided the necessary space radiation data for correlation to results obtained from the current analytical models used to predict exposure to the blood-forming organs. Numerous models (i.e., BRYNTRN and HZETRN) have been developed and used to predict radiation exposure. However, new models are continually being developed and evaluated. The Space Environment Information Systems (SPENVIS) modeling program, developed by the Belgian Institute for Space Aeronomy, is to be used and evaluated as a part of the research activity. It is the intent of this research effort to compare the modeled data to the findings from the STS-9 I mission; assess the accuracy and efficiency of this model; and to determine its usefulness for predicting radiation exposure and developing better guidelines for shielding requirements for long duration manned missions.

Denkins, Pamela↗

Adaptive Effects on Locomotion Performance Following Exposure to a Rotating Virtual Environment

During long-duration spaceflight, astronauts experience alterations in vestibular and somatosensory cues that result in adaptive disturbances in balance and coordination upon return to Earth. These changes can pose a risk to crew safety and to mission objectives if nominal or emergency vehicle egress is required immediately following long-duration spaceflight. At present, no operational countermeasure is available to mitigate the adaptive sensorimotor component underlying the locomotor disturbances that occur after spaceflight. Therefore, the goal of this study is to develop an inflight training regimen that facilitates recovery of locomotor function after long-duration spaceflight. The countermeasure we are proposing is based on the concept of adaptive generalization. During this type of training the subject gains experience producing the appropriate adaptive motor behavior under a variety of sensory conditions and response constraints. As a result of this training a subject learns to solve a class of motor problems, rather than a specific motor solution to one problem, i.e., the subject learns response generalizability or the ability to "learn to learn." under a variety of environmental constraints. We are developing an inflight countermeasure built around treadmill exercise activities. By manipulating the sensory conditions of exercise by varying visual flow patterns, body load and speed we will systematically and repeatedly promote adaptive change in locomotor behavior. It has been shown that variable practice training increases adaptability to novel visuo-motor situations. While walking over ground in a stereoscopic virtual environment that oscillated in roll, subjects have shown compensatory torso rotation in the direction of scene rotation that resulted in positional variation away from a desired linear path. Thus, postural sway and locomotor stability in 1-g can be modulated by visual flow patterns and used during inflight treadmill training to promote adaptive generalization. The purpose of this study was to determine if adaptive modification in locomotor performance could be achieved by viewing simulated self-motion in a passive-immersive virtual ' environment over a prolonged period during treadmill locomotion.

Mulavara, A. P.↗

Full-Scale Crash Test of an MD-500 Helicopter

A full-scale crash test was successfully conducted in March 2010 of an MD-500 helicopter at NASA Langley Research Center s Landing and Impact Research Facility. The reasons for conducting this test were threefold: 1 To generate data to be used with finite element computer modeling efforts, 2 To study the crashworthiness features typically associated with a small representative helicopter, and 3 To compare aircraft response to data collected from a previously conducted MD-500 crash test, which included an externally deployable energy absorbing (DEA) concept. Instrumentation on the airframe included accelerometers on various structural components of the airframe; and strain gages on keel beams, skid gear and portions of the skin. Three Anthropomorphic Test Devices and a specialized Human Surrogate Torso Model were also onboard to collect occupant loads for evaluation with common injury risk criteria. This paper presents background and results from this crash test conducted without the DEA concept. These results showed accelerations of approximately 30 to 50 g on the airframe at various locations, little energy attenuation through the airframe, and moderate to high probability of occupant injury for a variety of injury criteria.

Littell, Justin↗

A New Method for Interfacing Unsuited Subjects to Overhead Suspension Partial Gravity Simulators

The purpose of performing unsuited testing as part of a reduced gravity extravehicular (EVA) suited human performance research program is to define baseline performance. These results are then coupled with suited test results to evaluate how the suit system affects human performance at reduced gravity. The primary drawback to this approach is that previous studies used notably different systems to interface suited and unsuited subjects to overhead-suspension, partial-gravity simulators. A spreader bar (SB) assembly previously used for unsuited tests allowed limited pitch and roll of the subject, whereas the gimbal for suited tests allowed more pitch and roll, although the mass distribution led to large moments of inertia in the yaw axis. It is hypothesized that use of the same methods for offload of both unsuited and suited subjects is needed to make meaningful comparisons. A new gimbal (GIM) was designed with the idea that it could function with both suited and unsuited subjects. GIM was designed to minimize mass and moments of inertia and to be adjustable to co-locate the 3 axes of rotation with the subject s center of gravity. OBJECTIVE: To evaluate human performance differences between SB and GIM. METHODS: Ten unsuited subjects were offloaded to 1/6-g using both interfaces. Subjects completed tasks including overground and treadmill ambulation, picking up objects, shoveling, postural stability, range of motion testing, and recovery from the kneeling and prone positions. Metabolic, biomechanical, and/or subjective data were collected based on task. RESULTS: Initial analyses suggest that subjects completed all tasks with lower levels of compensation and a more terrestrial approach to movement when suspended via GIM. With SB, subjects were not able to fall or get into a prone position and had increased difficulty both retrieving objects off the floor and with overground ambulation, especially at gait initiation, because they were unable to bend their torso. GIM shows promise as a new method.

Norcross, Jason↗

A Comparative Analysis of Two Full-Scale MD-500 Helicopter Crash Tests

Two full scale crash tests were conducted on a small MD-500 helicopter at NASA Langley Research Center fs Landing and Impact Research Facility. One of the objectives of this test series was to compare airframe impact response and occupant injury data between a test which outfitted the airframe with an external composite passive energy absorbing honeycomb and a test which had no energy absorbing features. In both tests, the nominal impact velocity conditions were 7.92 m/sec (26 ft/sec) vertical and 12.2 m/sec (40 ft/sec) horizontal, and the test article weighed approximately 1315 kg (2900 lbs). Airframe instrumentation included accelerometers and strain gages. Four Anthropomorphic Test Devices were also onboard; three of which were standard Hybrid II and III, while the fourth was a specialized torso. The test which contained the energy absorbing honeycomb showed vertical impact acceleration loads of approximately 15 g, low risk for occupant injury probability, and minimal airframe damage. These results were contrasted with the test conducted without the energy absorbing honeycomb. The test results showed airframe accelerations of approximately 40 g in the vertical direction, high risk for injury probability in the occupants, and substantial airframe damage.

Littell, Justin D.↗

Shoulder Injuries in US Astronauts Related to EVA Suit Design

Introduction: For every one hour spent performing extravehicular activity (EVA) in space, astronauts in the US space program spend approximately six to ten hours training in the EVA spacesuit at NASA-Johnson Space Center's Neutral Buoyancy Lab (NBL). In 1997, NASA introduced the planar hard upper torso (HUT) EVA spacesuit which subsequently replaced the existing pivoted HUT. An extra joint in the pivoted shoulder allows increased mobility but also increased complexity. Over the next decade a number of astronauts developed shoulder problems requiring surgical intervention, many of whom performed EVA training in the NBL. This study investigated whether changing HUT designs led to shoulder injuries requiring surgical repair. Methods: US astronaut EVA training data and spacesuit design employed were analyzed from the NBL data. Shoulder surgery data was acquired from the medical record database, and causal mechanisms were obtained from personal interviews Analysis of the individual HUT designs was performed as it related to normal shoulder biomechanics. Results: To date, 23 US astronauts have required 25 shoulder surgeries. Approximately 48% (11/23) directly attributed their injury to training in the planar HUT, whereas none attributed their injury to training in the pivoted HUT. The planar HUT design limits shoulder abduction to 90 degrees compared to approximately 120 degrees in the pivoted HUT. The planar HUT also forces the shoulder into a forward flexed position requiring active retraction and extension to increase abduction beyond 90 degrees. Discussion: Multiple factors are associated with mechanisms leading to shoulder injury requiring surgical repair. Limitations to normal shoulder mechanics, suit fit, donning/doffing, body position, pre-existing injury, tool weight and configuration, age, in-suit activity, and HUT design have all been identified as potential sources of injury. Conclusion: Crewmembers with pre-existing or current shoulder injuries or certain anthropometric body types should conduct NBL EVA training in the pivoted HUT.

Scheuring, R. A.↗

New Padded Harness for Self-Acquisition of Resting 12-Lead ECGs

We have developed a dry-electrode harness that permits easy, rapid, and unsupervised self-acquisition of resting 12-lead ECGs without the use of any disposables. Various other advantageous features of the harness include: 1) padded or inflatable cushions at the lateral sides of the torso that function to press the left arm (LA) and right arm (RA) dry electrodes mounted on cushions against sideward (as shown in the Figure below) or downward-rested arms of the subject; 2) sufficient distal placement of the arm electrodes with good abutment and without the need for adhesives, straps, bands, bracelets, or gloves on the arms; 3) padding over the sternum to avoid "tenting" in the V1 through V3 (and V3R, when present) electrode positions; 4) easy-to-don, one-piece design with an adjustable single point of connection and an adjustable shoulder strap; and 5) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar lead placements.

Schlegel, T. T.↗

NASA Tech Briefs, December 2011

Topics covered include: 1) SNE Industrial Fieldbus Interface; 2) Composite Thermal Switch; 3) XMOS XC-2 Development Board for Mechanical Control and Data Collection; 4) Receiver Gain Modulation Circuit; 5) NEXUS Scalable and Distributed Next-Generation Avionics Bus for Space Missions; 6) Digital Interface Board to Control Phase and Amplitude of Four Channels; 7) CoNNeCT Baseband Processor Module; 8) Cryogenic 160-GHz MMIC Heterodyne Receiver Module; 9) Ka-Band, Multi-Gigabit-Per-Second Transceiver; 10) All-Solid-State 2.45-to-2.78-THz Source; 11) Onboard Interferometric SAR Processor for the Ka-Band Radar Interferometer (KaRIn); 12) Space Environments Testbed; 13) High-Performance 3D Articulated Robot Display; 14) Athena; 15) In Situ Surface Characterization; 16) Ndarts; 17) Cryo-Etched Black Silicon for Use as Optical Black; 18) Advanced CO2 Removal and Reduction System; 19) Correcting Thermal Deformations in an Active Composite Reflector; 20) Umbilical Deployment Device; 21) Space Mirror Alignment System; 22) Thermionic Power Cell To Harness Heat Energies for Geothermal Applications; 23) Graph Theory Roots of Spatial Operators for Kinematics and Dynamics; 24) Spacesuit Soft Upper Torso Sizing Systems; 25) Radiation Protection Using Single-Wall Carbon Nanotube Derivatives; 26) PMA-PhyloChip DNA Microarray to Elucidate Viable Microbial Community Structure; 27) Lidar Luminance Quantizer; 28) Distributed Capacitive Sensor for Sample Mass Measurement; 29) Base Flow Model Validation; 30) Minimum Landing Error Powered-Descent Guidance for Planetary Missions; 31) Framework for Integrating Science Data Processing Algorithms Into Process Control Systems; 32) Time Synchronization and Distribution Mechanisms for Space Networks; 33) Local Estimators for Spacecraft Formation Flying; 34) Software-Defined Radio for Space-to-Space Communications; 35) Reflective Occultation Mask for Evaluation of Occulter Designs for Planet Finding; and 36) Molecular Adsorber Coating

Source record↗

Advancing Robotic Control for Space Exploration Using Robonaut 2

Robonaut 2, or R2, arrived on the International Space Station (ISS) in February 2011 and is currently being tested in preparation for its role initially as an Intra-Vehicular Activity (IVA) tool and eventually as a robot that performs Extra-Vehicular Activities (EVA). Robonaut 2, is a state of the art dexterous anthropomorphic robotic torso designed for assisting astronauts. R2 features increased force sensing, greater range of motion, higher bandwidth, and improved dexterity over its predecessor. Robonaut 2 is unique in its ability to safely allow humans in its workspace and to perform significant tasks in a workspace designed for humans. The current operational paradigm involves either the crew or the ground control team running semi-autonomous scripts on the robot as both the astronaut and the ground team monitor R2 and the data it produces. While this is appropriate for the check-out phase of operations, the future plans for R2 will stress the current operational framework. The approach described here will outline a suite of operational modes that will be developed for Robonaut 2. These operational modes include teleoperation, shared control, directed autonomy, and supervised autonomy, and they cover a spectrum of human involvement in controlling R2.

Badger, Julia↗

Wireless Self-Acquistion of 12-Lead ECG via Android Smart Phone

Researchers at NASA s Johnson Space Center and at Orbital Research, Inc. (a NASA SBIR grant recipient) have recently developed a dry-electrode harness that allows for self-acquisition of resting 12-lead ECGs by minimally trained laypersons. When used in conjunction with commercial wireless (e.g., Bluetooth(TM) or 802.11-enabled) 12-lead ECG devices and custom smart phone-based software, the collected 12-lead ECG data can also immediately be forwarded from any geographic location within cellular range to the user s physician(s) of choice. The system can also be used to immediately forward to central receiving stations 12-lead ECG data collected during space flight or during activities in any remote terrestrial location supported by an internet or cellular phone infrastructure. The main novel aspects of the system are first, the dry-electrode 12-lead ECG harness itself, and second, an accompanying Android(TM) smart phone-based wireless 12-lead ECG capability. The ECG harness nominally employs dry electrodes manufactured by Orbital Research, Inc, recently cleared through the Food and Drug Administration (FDA). However, other dry electrodes that are not yet FDA cleared, for example those recently developed by Nanosonic, Inc as part of another NASA SBIR grant, can also be used. The various advantageous features of the harness include: 1) laypersons can be quickly instructed on its correct use, remotely if necessary; 2) all tangled "leadwire spaghetti" is eliminated, as is the common clinical problem of "leadwire reversal"; 3) all adhesives and disposables are also eliminated, the harness being fully reusable; if multiple individuals intend to use use the same harness, then standard antimicrobial wipes can be employed to sterilize the dry electrodes (and harness surface if needed) between users; 5) padded cushions at the lateral sides of the torso function to press the left arm (LA) and right arm (RA) dry electrodes mounted on the cushions against sideward or downward-rested arms of the subject; 6) sufficient distal placement of the arm electrodes achieves good electrode abutment to the arms without the need for adhesives, straps, bands, bracelets, or gloves; 7) padding over the sternum avoids "tenting" in the V1 through V3 (and, when present, the V3R) electrode positions; 8) easy-to-don, one-piece design with an adjustable, front-side single point of connection and an adjustable shoulder strap; and 9) Lund or "modified Lund" placement of the dry electrodes, the results of which more effectively reproduce results from "standard" 12-lead ECG placements than do results from Mason-Likar placements. The main limitation of the harness is that "one size does not fit all", meaning that an appropriately sized harness (small, medium, large, etc) must be chosen on the basis of an individual's size. To facilitate the use of the harness with inexpensive, commodity-grade cell phones and tablet devices, 12-lead ECG software is also being developed to accompany the harness for wireless use with Android. For this part of the project, NASA has teamed with TopCoder, Inc and the Harvard-affiliated NASA Tournament Lab in sponsoring java-based software programming contests through TopCoder. While ECG signals from the harness can already be wirelessly received and thoroughly processed (locally or remotely) by commercial-grade conventional (as well as advanced) 12-lead ECG software running on Microsoft Windows(TM), the Android-based software, once completed, will "cast a wider net" by allowing for a greater percentage of cell phone owners to participate in inexpensive, store-and-forward recordings of 12-lead ECGs worldwide, including for example Android cell phone users in many remote, third-world locations. At the time of writing, the Android 12-lead ECG software platform consists of a basic but expanding graphical user interface and accompanying software that: 1) wirelessly receives the 12-lead ECG data stream from a Bluetooth-based, FDA-cleared 12-leaCG device attached to the harness; 2) locally stores the same data in binary format to the SD card on the Android cell phone; and 3) makes the data stream in available in real time, for now to TopCoder's java programming contestants.

Schlegel, Todd T.↗