Search NASA⌕ Search

SEARCH · Search NASA

Results for “total ozone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Correlation of 3 hour radiosonde data with coincident Nimbus-7 total ozone measurements

A special network exercise supporting the VAS demonstration is reported. The second near-real time total ozone mapping spectrometer (TOMS) activity involving out of sequence processing of Nimbus-7 data over the United States and Europe is presented. The ozone data maps were used by airlines to search for regions of clear air turbulence and by an aircraft data gathering program, for synoptic upper air and tropopause height analyses. The TOMS total ozone levels are correlated with radiosonde tropopause height for testing the ability of TOMS data to give independent satellite measurements of tropopause height.

Gatlin, J. A.↗

The morphology and meteorology of Southern Hemisphere spring total ozone mini-holes

The purpose of this paper is to describe the properties of mini-hole events. Both Total Ozone Mapping Spectrometer (TOMS) data and National Meteorological Center (NMC) meteorological analyses will be used to determine the horizontal, vertical and temporal characteristics of the mini-holes. Mini-holes are rapidly developing (1 to 5 days), small horizontal scale (1000 to 3000 km) features which appear in the polar total ozone field during September and October of each year. Typically, a total of 1 to 6 mini-holes appear each year in either the Palmer penninsula region or over the East Antarctica ice sheet. The mini-holes do not develop over these two regions, but they intensify most dramatically there (possibly associated with the local orography). The mini-holes are associated with cold pools of air in the lower stratosphere, anti-cyclonic (geopotential height highs) disturbances to their west, high potential vorticity slightly to the east, and strong northward flow. These meteorological features are baroclinic, having a distinct westward tilt with increasing altitude.

Newman, Paul A.↗

Total ozone trend over Cairo

A world wide interest in protecting ozone layer against manmade effects is now increasing. Assessment of the ozone depletion due to these activities depends on how successfully we can separate the natural variabilities from the data. The monthly mean values of total ozone over Cairo (30 05N) for the period 1968-1988, have been analyzed using the power spectral analysis technique. The technique used in this analysis does not depend on a pre-understanding of the natural fluctuations in the ozone data. The method depends on increasing the resolution of the spectral peaks in order to obtain the more accurate sinusoidal fluctuations with wavelength equal to or less than record length. Also it handles the possible sinusoidal fluctuations with wavelength equal to or less than record length. The results show that it is possible to detect some of the well known national fluctuations in the ozone record such as annual, semiannual, quasi-biennial and quasi-quadrennial oscillations. After separating the natural fluctuations from the ozone record, the trend analysis of total ozone over Cairo showed that a decrease of about -1.2% per decade has occurred since 1979.

Hassan, G. K. Y.↗

Depletions in winter total ozone values over southern England

A study has been made of the recently re-evaluated time series of daily total ozone values for the period 1979 to 1992 for southern England. The series consists of measurements made at two stations, Bracknell and Camborne. The series shows a steady decline in ozone values in the spring months over the period, and this is consistent with data from an earlier decade that has been published but not re-evaluated. Of exceptional note is the monthly mean for January 1992 which was very significantly reduced from the normal value, and was the lowest so far measured for this month. This winter was also noteworthy for a prolonged period during which a blocking anticyclone dominated the region, and the possibility existed that this was related to the ozone anomaly. It was possible to determine whether the origin of the low ozone value lay in ascending stratospheric motions. A linear regression analysis of ozone value deviation against 100hPa temperature deviations was used to reduce ozone values to those expected in the absence of high pressure. The assumption was made that the normal regression relation was not affected by atmospheric anomalies during the winter. This showed that vertical motions in the stratosphere only accounted for part of the ozone anomaly and that the main cause of the ozone deficit lay either in a reduced stratospheric circulation to which the anticyclone may be related or in chemical effects in the reduced stratospheric temperatures above the high pressure area. A study of the ozone time series adjusted to remove variations correlated with meteorological quantities, showed that during the period since 1979, one other winter, that of 1982/3, showed a similar although less well defined deficit in total ozone values.

Lapworth, A.↗

Data Validation for Earth Probe-Total Ozone Mapping Spectrometer

This presentation represents the final report for the NASA grant project. The goal of this project was to provide scientific analysis to aid in validation fo data sets used in detection of long term global trends of total ozone. Ozone data from the Earth Probe Total Ozone Mapping Spectrometer instrument was compared for validation purposes with features in previous TOMS data. Atmospheric dynamic concepts were used in the analysis. The publications sponsored by the grant are listed along with abstracts.

Stanford, John L.↗

Satellite estimation of spectral UVB irradiance using TOMS derived total ozone and UV reflectivity

A method for satellite remote sensing of spectral UVB radiation incident at the earth's surface for snow and/or ice free areas has been developed. Measurements of total ozone and UV reflectively from the Nimbus-7 Total Ozone Mapping Spectrometer (TOMS) instrument have been applied to this technique. Comparison of satellite estimates with ground based measurements of spectral UVB irradiance show differences which are comparable to differences between near simultaneous measurements made with two or more ground based co-located instruments.

Eck, T. F.↗

Constructing a coherent long-term global total ozone climatology from the BUV, MFR, and SBUV/TOMS data sets

Multichannel Filter Radiometer (MFR) data are intercompared with Solar Backscattered Ultraviolet (SBUV) and Total Ozone Mapping Spectrometer (TOMS) data during a five-month period of their data overlap in order to determine the usefulness of MFR data to represent the SBUV/TOMS and backscatter ultraviolet spectrometer data during their data gap period. Total ozone differences found were latitudinally and monthly dependent. Average differences between the TOMS and the MFR ozone data vary from -12.4 to +13.3 percent, with differences in the tropical to middle latitudes generally between + or - 4 percent. Biases between the data sets can be removed for certain latitude zones by applying an appropriate algorithm to the MFR ozone data.

Ellis, J. S.↗

Rossby-gravity waves in tropical total ozone data

Evidence for Rossby-gravity waves in tropical data fields produced by the European Center for Medium Range Weather Forecasts (ECMWF) was recently reported. Similar features are observable in fields of total column ozone from the Total Ozone Mapping Spectrometer (TOMS) satellite instrument. The observed features are episodic, have zonal (east-west) wavelengths of 6,000-10,000 km, and oscillate with periods of 5-10 days. In accord with simple linear theory, the modes exhibit westward phase progression and eastward group velocity. The significance of finding Rossby-gravity waves in total ozone fields is that (1) the report of similar features in ECMWF tropical fields is corroborated with an independent data set and (2) the TOMS data set is demonstrated to possess surprising versatility and sensitivity to relatively smaller scale tropical phenomena.

Stanford, J. L.↗

October Antarctic temperature and total ozone trends from 1979-1985

The morphology of temperature trends in the south polar stratosphere from 1979-1985 is detailed. A significant cooling has occurred in the stratosphere over this period. South polar October mean temperatures have declined 18 K at 24 km over the seven-year period. A large fraction of this decline occurs as a result of including 1979 temperatures in the trend. The years 1979 and 1982 differ from other years in that they include large mid-October wave events which produce significantly warmer polar temperatures. Nevertheless, a significant temperature decline has still occurred in the stratosphere even when the dynamically active years are not included. Comparing two relatively dynamically quiet years, 1980 and 1985, the largest temperature decrease in the 30 mb temperature field occurs not at the pole but in the subpolar temperature maximum centered near 60 deg S. The changes in temperature of both the maximum and the polar low regions correlate fairly well with total ozone changes observed by the Total Ozone Mapping Spectrophotometer.

Newman, Paul A.↗

Long-term changes in the statistical distribution of Dobson total ozone in selected Northern Hemisphere geographical regions

The daily averages of total column amount of ozone taken in the period 1964-1988 at a network of 24 Dobson stations have been analyzed. Year-round data as well as summer data (May - Aug.) and winter data (Dec. - March) have been examined in the following regions: latitude bands (30 deg N - 39 deg N, 40 deg N - 52 deg N, 30 deg N - 60 deg N), North America, Europe, and Japan. To find year-to-year changes in the shape of the annual statistical distribution of total ozone (ASDTO) for these regions, we analyze trends in the following statistic characteristics of ASDTO: mean, standard deviation, median, and 10 and 90 percentiles. Time series of the statistical characteristics for the selected regions have been combined by averaging the individual stations values of these characteristics. The trends have been calculated by the multiple regression model adjusted for: the 11-year solar cycle, the Southern Oscillations effects, and for serial correlations. We have found that: a) in all regions (excluding Japan, North America), the shape of ASDTO has been drifting towards low ozone values. The drift seems to be not accompanied with a transformation in the shape of ASDTO. The drift speed (the rate of decrease in the annual means of total ozone) is of order 1-3 percent per decade (in the period 1970-1988). b) In Japan, the interannual changes in the shape of ASDTO have not been revealed. c) In North America, the drift of the year-round ASDTO (the year-round ASDTO comprises all the daily means of total ozone in a given year) has been accompanied with a transformation in the shape. The shape of the year round ASDTO becomes narrower. d) In all regions, except Japan and the band 30 deg - 39 deg N, the winter ASDTO (the winter ASDTO comprises the data taken in the period December in a given year through March next year) moves faster towards low ozone values than the summer ASDTO (the summer ASDTO comprises the data taken in the period May through August in a given year).

Krzyscin, Janusz W.↗

Preliminary results of an intercomparison of total ozone spectrophotometers

Preliminary results from an intercomparison of five total ozone spectrophotometers are presented. These are the Dobson spectrophotometer, the USSR M-83 ozonometer, the Canterbury filter photometer, the SenTran Company filter photometer, and the Brewer grating spectrophotometer. The pertinent characteristics of each are described, and conclusions are drawn about the agreement of each instrument's measurements with the Dobson's values over a time period of nearly one year. A discussion of the importance of calibration and long-term stability and reliability is included.

Parsons, C. L.↗

Total ozone change estimations for different time intervals

To investigate total ozone behavior in different time intervals for the 40 deg - 52 deg N and 53 deg - 64 deg N latitudinal bands sliding 11 year linear trends with the first interval from 1959 to 1969 and the final one from 1980 to 1990 were computed. The most recent 11-year trends are negative and have larger absolute values than in the past. The trend values in the period from 1980 to 1990 in the 53 deg - 64 deg N band are minus 4.3 percent (winter), minus 3.2 percent (summer), and minus 3.8 percent (annual) per decade, and in the 40 deg - 52 deg N band they are minus 5.9 percent (winter), minus 2.7 percent (summer), and minus 3.6 percent (annual) per decade.

Fioletov, Vitali E.↗

Project Description for Meteor-3/TOMS (Total Ozone Mapping Spectrometer)

This document provides Goddard Space Flight Center's (GSFC) Project Description for the Meteor-3/TOMS mission_ The Meteor-3/TOMS mission is a joint USA/USSR scientific program in which a US Total Ozone Mapping Spectrometer (TOMS) instrument will fly on a USSR Meteor-3 spacecraft. The National Aeronautics and Space Administration (NASA) has initiated the Meteor-3/TOMS Project to provide a continuation of the decade-long global coverage obtained with the Nimbus-7 TOMS instrument. The scientific goal is to gather global total ozone data of an environmental importance to both countries as well as to all peoples of the earth.

Source record↗

Inference of total ozone from photometric measurements of sky radiation.

Ground-based photometric measurements of spectral sky radiation have been made using a simple filter instrument. Sky radiation intensities measured in the solar vertical at 3200 and 3600 A are compared to infer total ozone. A model of a multiple scattering Rayleigh atmosphere serves as a primary reduction parameter. Spectral measurements of all-sky radiance distribution are used to study the effects of haze and clouds on the inference of total ozone. The brightness distribution of clear and overcast sky in ultraviolet is also described.

Ghazi, A.↗

Determination of Total Ozone over Mauna Loa Using Very High Resolution Infrared Solar Spectra

A very high resolution infrared Fourier transform spectrometer has been used to record solar spectra at the Mauna Loa Observatory in Hawaii. Spectra are normally taken one day a week at sunrise. These spectra have been analyzed for ozone and N2O total columns, and the ozone column compared with the value reported by tile Mauna Loa Dobson spectrophotometer. Aside from the FTIR reporting about 5% lower values than the Dobson (which may be due to a systematic difference in the treatment of tropospheric ozone), the FTIR and Dobson agree to within 2.7% (RMS) during this period.

David, Shelle J.↗

Sources of background current in the ECC ozonesonde - Implications for total ozone measurements

The source of the background current in the usual operation of the electrochemical concentration cell ozonesonde is the reduction of tri-iodide normally present in the cathode solution. The time variations in the background current can be explained by the slow rates of solution mass transport and of heterogeneous electron transfer for tri-iodide. Oxygen does not contribute to the background current through reaction with iodide to produce tri-iodide. Direct reduction of oxygen at the cathode is negligible once the electrodes have been exposed to iodide for 24 hours. The present background current correction is altitude-dependent, since it is based on an assumed sensitivity of the electrochemical concentration cell to oxygen. If the background current is independent of altitude and of oxygen, a constant, uncorrected, background current of 0.1 microamp would produce an error of +5.5% for the total ozone value of the electrochemical concentration cell for a typical midlatitude total ozone value of 0.345 atm-cm.

Thornton, D. C.↗

Evidence for quasi-periodic components in Dobson network total ozone records

Power spectrum analysis has been applied to the total ozone time series at each of a sample of Dobson stations with records of more than 15 years in the interval 1957 to 1981. The distributions of strongly periodic or quasiperiodic signals in these spectral estimates, for three spectral estimators and two levels of confidence, show distinct features. These appear at the previously known or suspected periods of 3.5-4.0 years, 27 months, and 21 months as well as the previously unreported period of 11.5 months. Possible geophysical implications are discussed.

Guthrie, P. D.↗

Satellite maps of Antarctic total ozone

Satellite remote sensing techniques for ozone have made it possible to observe the detailed, daily horizontal structure of atmospheric ozone at all locations where sunlight is present. The Antarctic ozone 'hole' has been observed with the Total Ozone Mapping Spectrometer (TOMS) instrument since launch of Nimbus 7 in 1978. This feature is a continental-size ozone minimum found in the Antarctic winter and spring seasons which has generally deepened in recent years to levels in 1985 and 1987 far below the lowest values ever observed elsewhere. The minimum appears to be produced by atmospheric circulations, but the deepening almost certainly involves chemistry which is unique to cold, dark conditions.

Krueger, Arlin J.↗