Search NASA⌕ Search

SEARCH · Search NASA

Results for “total scattering coefficient”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Four Isotope-Labeled Recombination Pathways of Ozone Formation

A theoretical approach is developed for the description of all possible recombination pathways in the ozone forming reaction, without neglecting any process a priori, and without decoupling the individual pathways one from another. These pathways become physically distinct when a rare isotope of oxygen is introduced, such as 18 O, which represents a sensitive probe of the ozone forming reaction. Each isotopologue of O 3 contains two types of physically distinct entrance channels and two types of physically distinct product wells, creating four recombination pathways. Calculations are done for singly and doubly substituted isotopologues of ozone, eight rate coefficients total. Two pathways for the formation of asymmetric ozone isotopomer exhibit rather different rate coefficients, indicating large isotope effect driven by ΔZPE-difference. Rate coefficient for the formation of symmetric isotopomer of ozone (third pathway) is found to be in between of those two, while the rate of insertion pathway is smaller by two orders of magnitude. These trends are in good agreement with experiments, for both singly and doubly substituted ozone. The total formation rates for asymmetric isotopomers are found to be somewhat larger than those for symmetric isotopomers, but not as much as in the experiment. Altogether, the distribution of lifetimes is found to be very similar for the metastable states in symmetric and asymmetric ozone isotopomers.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pore-size dependence and characteristics of water diffusion in slitlike micropores

The temperature dependence of the dynamics of water inside microporous activated carbon fibers (ACF) is investigated by means of incoherent elastic and quasielastic neutron-scattering techniques. The aim is to evaluate the effect of increasing pore size on the water dynamics in these primarily hydrophobic slit-shaped channels. Using two different micropore sizes (similar to 12 and 18 angstrom, denoted, respectively, ACF-10 and ACF-20), a clear suppression of the mobility of the water molecules is observed as the pore gap or temperature decreases. Suppression, we found, is accompanied by a systematic dependence of the average translational diffusion coefficient D-r and relaxation time [tau(0)] of the restricted water on pore size and temperature. We observed D-r values and tested against a proposed scaling law, in which the translational diffusion coefficient D-r of water within a porous matrix was found to depend solely on two single parameters, a temperature-independent translational diffusion coefficient D-c associated with the water bound to the pore walls and the ratio theta of this strictly confined water to the total water inside the pore, yielding unique characteristic parameters for water transport in these carbon channels across the investigated temperature range.

36 MATERIALS SCIENCE↗

On a Spectral Method for β -particle Bound Excitation Collisions in Kilonovae

The interaction of β-particles with the weakly ionized plasma background is an important mechanism for powering the kilonova (KN) transient signal from neutron star mergers. For this purpose, we present an implementation of the approximate fast-particle collision kernel, described by Inokuti following the seminal formulation of Bethe, in a spectral solver of the Vlasov–Maxwell–Boltzmann equation. In particular, we expand the fast-particle plane-wave atomic excitation kernel into coefficients of the Hermite basis, and derive the relevant discrete spectral system. In this fast-particle limit, the approach permits the direct use of atomic data, including optical oscillator strengths, normally applied to photon–matter interaction. The resulting spectral matrix is implemented in the MASS-APP spectral solver framework, in a way that avoids full matrix storage per spatial zone. We numerically verify aspects of the matrix construction, and present a proof-of-principle 3D simulation of a 2D axisymmetric KN ejecta snapshot. Our preliminary numerical results indicate that a reasonable choice of Hermite basis parameters for β-particles in the KN is a bulk velocity parameter u = 0, a thermal velocity parameter α = 0.5c, and a 9 × 9 × 9 mode velocity basis set (Hermite orders of 0–8 in each dimension). For interior-ejecta sample zones, we estimate that the ratio of thermalization from large-angle (≳2fdg5) bound excitation scattering to total thermalization is ~0.002–0.003.

79 ASTRONOMY AND ASTROPHYSICS↗

Temperature dependence of APD-based PET scanners

Purpose: Solid state detectors such as avalanche photodiodes (APDs) are increasingly being used in PET detectors. One of the disadvantages of APDs is the strong decrease of their gain factor with increasing ambient temperature. The light yield of most scintillation crystals also decreases when ambient temperature is increased. Both effects lead to considerable temperature dependence of the performance of APD-based PET scanners. In this paper, the authors propose a model for this dependence and the performance of the LabPET8 APD-based small animal PET scanner is evaluated at different temperatures.Methods: The model proposes that the effect of increasing temperature on the energy histogram of an APD-based PET scanner is a compression of the histogram along the energy axis. The energy histogram of the LabPET system was acquired at 21 °C and 25 °C to verify the validity of this model. Using the proposed model, the effect of temperature on system sensitivity was simulated for different detector temperature coefficients and temperatures. Subsequently, the effect of short term and long term temperature changes on the peak sensitivity of the LabPET system was measured. The axial sensitivity profile was measured at 21 °C and 24 °C following the NEMA NU 4-2008 standard. System spatial resolution was also evaluated. Furthermore, scatter fraction, count losses and random coincidences were evaluated at different temperatures. Image quality was also investigated.Results: As predicted by the model, the photopeak energy at 25 °C is lower than at 21 °C with a shift of approximately 6% per °C. Simulations showed that this results in an approximately linear decrease of sensitivity when temperature is increased from 21 °C to 24 °C and energy thresholds are constant. Experimental evaluation of the peak sensitivity at different temperatures showed a strong linear correlation for short term (2.32 kcps/MBq/°C = 12%/°C, R = −0.95) and long term (1.92 kcps/MBq/°C = 10%/°C , R = −0.96) temperature changes. Count rate evaluation showed that although the total count rate is consistently higher at 21 °C than at 24 °C for different source activity concentrations, this is mainly due to an increase in scattered and random coincidences. The peak total count rate is 400 kcps at both temperatures but is reached at lower activity at 21 °C. The peak true count rate is 138 kcps (at 100 MBq) at 21 °C and 180 kcps (at 125 MBq) at 24 °C. The peak noise equivalent count rate is also lower at 21 °C (70 kcps at 70 MBq) than at 24 °C (100 kcps at 100 MBq). At realistic activity levels, the scatter fraction is lower at higher temperatures, but at the cost of a strong decrease in true count rate.Conclusions: A model was proposed for the temperature dependence of APD-based PET scanners and evaluated using the LabPET small animal PET scanner. System sensitivity and count rate performance are strongly dependent on ambient temperature while system resolution is not. The authors’ results indicate that it is important to assure stable ambient temperature to obtain reproducible results in imaging studies with APD-based PET scanners.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The quantitative potential for breast tomosynthesis imaging

Purpose: Due to its limited angular scan range, breast tomosynthesis has lower resolution in the depth direction, which may limit its accuracy in quantifying tissue density. This study assesses the quantitative potential of breast tomosynthesis using relatively simple reconstruction and image processing algorithms. This quantitation could allow improved characterization of lesions as well as image processing to present tomosynthesis images with the familiar appearance of mammography by preserving more low-frequency information. Methods: All studies were based on a Siemens prototype MAMMOMAT Novation TOMO breast tomo system with a 45 deg. total angular span. This investigation was performed using both simulations and empirical measurements. Monte Carlo simulations were conducted using the breast tomosynthesis geometry and tissue-equivalent, uniform, voxelized phantoms with cuboid lesions of varying density embedded within. Empirical studies were then performed using tissue-equivalent plastic phantoms which were imaged on the actual prototype system. The material surrounding the lesions was set to either fat-equivalent or glandular-equivalent plastic. From the simulation experiments, the effects of scatter, lesion depth, and background material density were studied. The empirical experiments studied the effects of lesion depth, background material density, x-ray tube energy, and exposure level. Additionally, the proposed analysis methods were independently evaluated using a commercially available QA breast phantom (CIRS Model 11A). All image reconstruction was performed with a filtered backprojection algorithm. Reconstructed voxel values within each slice were corrected to reduce background nonuniformities. Results: The resulting lesion voxel values varied linearly with known glandular fraction (correlation coefficient R{sup 2}>0.90) under all simulated and empirical conditions, including for the independent tests with the QA phantom. Analysis of variance performed on the fit line parameters revealed statistically significant differences between the two different background materials and between 28 kVp and the remaining energies (26, 30, and 32 kVp) for the dense experimental phantom. However, no significant differences arose between different energies for the fatty phantom, nor for any of the many other combinations of parameters. Conclusions: These strong linear relationships suggest that breast tomosynthesis image voxel values, after being corrected by our outlined methods, are highly positively correlated with true tissue density. This consistent linearity implies that breast tomosynthesis imaging indeed has potential to be quantitative.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

ANALYTICAL MODELS OF EXOPLANETARY ATMOSPHERES. II. RADIATIVE TRANSFER VIA THE TWO-STREAM APPROXIMATION

We present a comprehensive analytical study of radiative transfer using the method of moments and include the effects of non-isotropic scattering in the coherent limit. Within this unified formalism, we derive the governing equations and solutions describing two-stream radiative transfer (which approximates the passage of radiation as a pair of outgoing and incoming fluxes), flux-limited diffusion (which describes radiative transfer in the deep interior), and solutions for the temperature-pressure profiles. Generally, the problem is mathematically underdetermined unless a set of closures (Eddington coefficients) is specified. We demonstrate that the hemispheric (or hemi-isotropic) closure naturally derives from the radiative transfer equation if energy conservation is obeyed, while the Eddington closure produces spurious enhancements of both reflected light and thermal emission. We concoct recipes for implementing two-stream radiative transfer in stand-alone numerical calculations and general circulation models. We use our two-stream solutions to construct toy models of the runaway greenhouse effect. We present a new solution for temperature-pressure profiles with a non-constant optical opacity and elucidate the effects of non-isotropic scattering in the optical and infrared. We derive generalized expressions for the spherical and Bond albedos and the photon deposition depth. We demonstrate that the value of the optical depth corresponding to the photosphere is not always 2/3 (Milne's solution) and depends on a combination of stellar irradiation, internal heat, and the properties of scattering in both the optical and infrared. Finally, we derive generalized expressions for the total, net, outgoing, and incoming fluxes in the convective regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Astrophysical S factor for the radiative capture {sup 12}N(p,{gamma}){sup 13}O determined from the {sup 14}N({sup 12}N,{sup 13}O){sup 13}C proton transfer reaction

The cross section of the radiative proton capture reaction on the drip line nucleus {sup 12}N was investigated using the asymptotic normalization coefficient (ANC) method. We have used the {sup 14}N({sup 12}N,{sup 13}O){sup 13}C proton transfer reaction at 12 MeV/nucleon to extract the ANC for {sup 13}O{yields}{sup 12}N+p and calculate from it the direct component of the astrophysical S factor of the {sup 12}N(p,{gamma}){sup 13}O reaction. The optical potentials used and the distorted-wave Born approximation analysis of the proton transfer reaction are discussed. For the entrance channel, the optical potential was inferred from an elastic scattering measurement carried out at the same time as the transfer measurement. From the transfer, we determined the square of the ANC, C{sub p{sub 1/2}}{sup 2}({sup 13}O{sub g.s.})=2.53{+-}0.30 fm{sup -1}, and hence a value of 0.33(4) keV b was obtained for the direct astrophysical S factor at zero energy. Constructive interference at low energies between the direct and resonant captures leads to an enhancement of S{sub total}(0)=0.42(6) keV b. The {sup 12}N(p,{gamma}){sup 13}O reaction was investigated in relation to the evolution of hydrogen-rich massive Population III stars, for the role that it may play in the hot pp-chain nuclear burning processes, possibly occurring in such objects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Electronic band structure and optical properties of titanium oxyphosphates Li{sub 0.50}Co{sub 0.25}TiO(PO{sub 4}) single crystals: An ab-initio calculations

From the refined atomic positions obtained by Belmal et al. (2004) using X-ray diffraction for Li{sub 0.50}Co{sub 0.25}TiO(PO{sub 4}), we have performed a structural optimization by minimizing the forces acting on the atoms keeping the lattice parameters fixed at the experimental values. With this relaxed (optimized) geometry we have performed a comprehensive theoretical study of electronic properties and dispersion of the linear optical susceptibilities using the full potential linear augmented plane wave (FP-LAPW) method. The generalized gradient approximation (GGA) exchange-correlation potential was applied. In addition, the Engel-Vosko generalized gradient approximation (EVGGA) was used for comparison with GGA because it is known that EVGGA approach yields better band splitting compared to the GGA. We have calculated the band structure, and the total and partial densities of states. The electron charge densities and the bonding properties were analyzed and discussed. The complex dielectric optical susceptibilities were discussed in detail. - Graphical abstract: It is shown that P is tetrahedrally coordinated by four O ions. Highlights: > Comprehensive theoretical study of electronic and optical properties was performed. > Using X-ray diffraction data we have performed a structural optimization. > The electron charge densities and the bonding properties were analyzed and discussed. > Fermi surface was analyzed since it is useful for predicting thermal, magnetic, and optical properties. > The density of states at E{sub F} and the electronic specific heat coefficient were calculated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MEASURING GRAVITATIONAL LENSING FLEXION IN A1689 USING AN ANALYTIC IMAGE MODEL

Measuring dark matter substructure within galaxy cluster halos is a fundamental probe of the {Lambda}CDM model of structure formation. Gravitational lensing is a technique for measuring the total mass distribution which is independent of the nature of the gravitating matter, making it a vital tool for studying these dark-matter-dominated objects. We present a new method for measuring weak gravitational lensing flexion fields, the gradients of the lensing shear field, to measure mass distributions on small angular scales. While previously published methods for measuring flexion focus on measuring derived properties of the lensed images, such as shapelet coefficients or surface brightness moments, our method instead fits a mass-sheet transformation invariant Analytic Image Model (AIM) to each galaxy image. This simple parametric model traces the distortion of lensed image isophotes and constrains the flexion fields. We test the AIM method using simulated data images with realistic noise and a variety of unlensed image properties, and show that it successfully reproduces the input flexion fields. We also apply the AIM method for flexion measurement to Hubble Space Telescope observations of A1689 and detect mass structure in the cluster using flexion measured with this method. We also estimate the scatter in the measured flexion fields due to the unlensed shape of the background galaxies and find values consistent with previous estimates.

79 ASTRONOMY AND ASTROPHYSICS↗

TU-A-9A-11: Gold Nanoparticles Enhanced Diffuse Optical Tomography: A Proof of Concept Study

Purpose: To investigate the feasibility and potential of gold nanoparticles (GNP) enhanced diffuse optical tomography (DOT) as a novel imaging strategy for tumor detection. Methods: Simulation was performed on a digital homogeneous cylindrical phantom of 30mm×30mm. Gold nanorods (GNR) with aspect ratio 3.9 and effective radius 21.86nm were used as contrast agent. The peak light absorption for these GNR occurs at 842nm within the near-infrared region, with the absorption cross-section of 1.97×10{sup -14}m{sup -2} and scatter cross-section of 1.07×10{sup -14}m{sup -2}. A 6mmdiameter sphere of GNR solution was positioned inside the tissue-simulating phantom. Simulations were performed at the GNR concentration level of 1nM, 100pM and 10pM, respectively. The points representing laser sources and light detectors were around the phantom with 30o apart tangentially and 1mm apart axially for 9 rows. As one point being source, all the other points within the current row and nearby four rows become detectors. Hence there are 108 source points in total and 55 detector points corresponding to each source. Forward light transport at 842nm wavelength was run on a three-dimensional mesh of 33186 nodes (∼0.5mm resolution) to acquire the light emission data. Reconstruction was performed on a coarse mesh of 19408 nodes (∼1mm resolution) with ∼20minutes on a 2.4GHz CPU and 8GB RAM computer. Results: The position of the GNR solution at 1nM, 100pM and 10pM concentration was reconstructed, respectively, with <1mm error. The GNR concentration was interpreted from the reconstructed absorption coefficient within the enhanced volume. The reconstructed maximum concentrations were 0.3nM, 120.0pM, and 5.3pM, respectively. Conclusion: To the best of our knowledge, this is the first time to apply GNP to enhance DOT. The simulation results showed the high sensitivity of GNP enhanced DOT, which is in pM concentration level, compared to the μM level for MRI agents and nM level for PET agents.

60 APPLIED LIFE SCIENCES↗

Synthesis and evaluation of lead telluride/bismuth antimony telluride nanocomposites for thermoelectric applications

Heterogeneous nanocomposites of p-type bismuth antimony telluride (Bi{sub 2-x}Sb{sub x}Te{sub 3}) with lead telluride (PbTe) nanoinclusions have been prepared by an incipient wetness impregnation approach. The Seebeck coefficient, electrical resistivity, thermal conductivity and Hall coefficient were measured from 80 to 380 K in order to investigate the influence of PbTe nanoparticles on the thermoelectric performance of nanocomposites. The Seebeck coefficients and electrical resistivities of nanocomposites decrease with increasing PbTe nanoparticle concentration due to an increased hole concentration. The lattice thermal conductivity decreases with the addition of PbTe nanoparticles but the total thermal conductivity increases due to the increased electronic thermal conductivity. We conclude that the presence of nanosized PbTe in the bulk Bi{sub 2-x}Sb{sub x}Te{sub 3} matrix results in a collateral doping effect, which dominates transport properties. This study underscores the need for immiscible systems to achieve the decreased thermal transport properties possible from nanostructuring without compromising the electronic properties. - Graphical abstract: PbTe nanoparticles introduced into p-type Bi{sub 2}Te{sub 3} by incipient wetness results in decreased lattice thermal conductivity, but also acts as an electronic dopant, resulting in an overall decrease in thermoelectric performance. Highlights: Black-Right-Pointing-Pointer Composites of PbTe nanoparticles in Bi{sub 2-x}Sb{sub x}Te{sub 3} were formed by incipient wetness. Black-Right-Pointing-Pointer PbTe nanoparticles leads to decreased {kappa}{sub l}, consistent with phonon scattering. Black-Right-Pointing-Pointer PbTe nanoparticles lead to decreased S and {rho}, due to increased carriers. Black-Right-Pointing-Pointer Collateral doping from PbTe leads to decreased ZT with increasing concentration. Black-Right-Pointing-Pointer Immiscible systems are preferred for improved ZT.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Updates and Validation for the n+ 63,65 Cu Cross Sections [Abstract]

The neutron induced total, elastic, and capture cross sections of 63,65 Cu isotopes were selected for evaluation in the resolved and unresolved resonance energy ranges by the National Criticality Safety Program to resolve discrepancies related to benchmark performance. This is especially evident for the series of ZEUS benchmarks in which copper is used as a reflector. Because copper is also used as structural material in both fission and fusion reactors, the need to address benchmark discrepancies linked to nuclear data deficiencies is a task of primary importance. The aim of this work is to describe the steps of evaluation work towards a consistent improvement of the benchmark performance. The R-matrix analysis with the SAMMY code focused on the 63 Cu(n,γ) reaction channel between 100-300 keV coupled to unresolved resonance region parameters up to 650 keV to fit average cross section data from a recent experiment. Due to the high sensitivity of many benchmarks to elastic scattering angular distribution data, especially for the 65 Cu isotope, the impact of these data was tested by generating Legendre coefficients from both resonance parameters and the Hauser-Feshbach model. Guided by the findings of Shaw et al., the performance of the current evaluation for 65 Cu was compared to that of ENDF/B-VII.1 and ENDF/B-VIII.0 by testing the reactivity coefficients corresponding to the validation suite of experimental criticality benchmarks for thermal, intermediate, and fast systems taken from the International Criticality Safety Benchmark Experiments Project Handbook. The benchmark performance is especially sensitive to 63 Cu(n,γ) and 65 Cu elastic scattering for neutron energies in the 100–500 keV region, whereas 100 keV is the upper limit of the resolved resonance region in the ENDF/B-VIII.0 evaluations for 63,65 Cu. The results highlight the need to handle the transition from the resolved resonance region to the high energy region carefully.

07 ISOTOPE AND RADIATION SOURCES↗

Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy: Simulation of NIST air-kerma rate eBT calibration standard

Purpose: Dosimetry for the model S700 50 kV electronic brachytherapy (eBT) source (Xoft, Inc., a subsidiary of iCAD, San Jose, CA) was simulated using Monte Carlo (MC) methods by Rivard et al. [“Calculated and measured brachytherapy dosimetry parameters in water for the Xoft Axxent x-ray source: An electronic brachytherapy source,” Med. Phys. 33, 4020–4032 (2006)] and recently by Hiatt et al. [“A revised dosimetric characterization of the model S700 electronic brachytherapy source containing an anode-centering plastic insert and other components not included in the 2006 model,” Med. Phys. 42, 2764–2776 (2015)] with improved geometric characterization. Additionally, while these studies examined the dose distribution in water, there have not previously been reports of the eBT source calibration methods beyond that recently reported by Seltzer et al. [“New national air-kerma standard for low-energy electronic brachytherapy sources,” J. Res. Natl. Inst. Stand. Technol. 119, 554–574 (2014)]. Therefore, the motivation for the current study was to provide an independent determination of air-kerma rate at 50 cm in air K air (d = 50 cm) using MC methods for the model S700 eBT source. Methods: Using CAD information provided by the vendor and disassembled sources, an MC model was created for the S700 eBT source. Simulations were run using the mcnp6 radiation transport code for the NIST Lamperti air ionization chamber according to specifications by Boutillon et al. [“Comparison of exposure standards in the 10-50 kV x-ray region,” Metrologia 5, 1–11 (1969)], in air without the Lamperti chamber, and in vacuum without the Lamperti chamber. K air (d = 50 cm) was determined using the *F4 tally with NIST values for the mass energy-absorption coefficients for air. Photon spectra were evaluated over 2π azimuthal sampling for polar angles of 0° ≤ θ ≤ 180° every 1°. Volume averaging was averted through tight radial binning. Photon energy spectra were determined over all polar angles in both air and vacuum using the F4 tally with 0.1 keV resolution. A total of 10 11 simulated histories were run for the Lamperti chamber geometry (statistical uncertainty of 0.14%), with 10 10 histories for the in-air and in-vacuum simulations (statistical uncertainty of 0.04%). The total standard uncertainty in the calculated air-kerma rate determination amounted to 6.8%. Results: MC simulations determined the air-kerma rate at 50 cm from the source with the modeled Lamperti chamber to be (1.850 ± 0.126) × 10 -4 Gy/s, which was within the range of K air (d = 50 cm) values (1.67–2.11) × 10 -4 Gy/s measured by NIST. The ratio of the photon spectra in air and in vacuum were in good agreement above 13 keV, and for θ < 150° where the influence of the Kovar sleeve and the Ag epoxy components caused increased scatter in air. Below 13 keV, the ratio of the photon spectra in air to vacuum exhibited a decrease that was attributed to increased attenuation of the photons in air. Across most of the energy range on the source transverse plane, there was good agreement between the authors' simulated spectra and that measured by NIST. Discrepancies were observed above 40 keV where the NIST spectrum had a steeper fall-off towards 50 keV. Conclusions: Through MC simulations of radiation transport, this study provided an independent validation of the measured air-kerma rate at 50 cm in air at NIST for the model S700 eBT source, with mean results in agreement within 3.3%. Lastly, this difference was smaller than the range (i.e., 23%) of the measured values.

61 RADIATION PROTECTION AND DOSIMETRY↗

Secondary neutron spectrum from 250-MeV passively scattered proton therapy: Measurement with an extended-range Bonner sphere system

Purpose: Secondary neutrons are an unavoidable consequence of proton therapy. While the neutron dose is low compared to the primary proton dose, its presence and contribution to the patient dose is nonetheless important. The most detailed information on neutrons includes an evaluation of the neutron spectrum. However, the vast majority of the literature that has reported secondary neutron spectra in proton therapy is based on computational methods rather than measurements. This is largely due to the inherent limitations in the majority of neutron detectors, which are either not suitable for spectral measurements or have limited response at energies greater than 20 MeV. Therefore, the primary objective of the present study was to measure a secondary neutron spectrum from a proton therapy beam using a spectrometer that is sensitive to neutron energies over the entire neutron energy spectrum. Methods: The authors measured the secondary neutron spectrum from a 250-MeV passively scattered proton beam in air at a distance of 100 cm laterally from isocenter using an extended-range Bonner sphere (ERBS) measurement system. Ambient dose equivalent H*(10) was calculated using measured fluence and fluence-to-ambient dose equivalent conversion coefficients. Results: The neutron fluence spectrum had a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate energy continuum between the thermal and evaporation peaks. The H*(10) was dominated by the neutrons in the evaporation peak because of both their high abundance and the large quality conversion coefficients in that energy interval. The H*(10) 100 cm laterally from isocenter was 1.6 mSv per proton Gy (to isocenter). Approximately 35% of the dose equivalent was from neutrons with energies ≥20 MeV. Conclusions: The authors measured a neutron spectrum for external neutrons generated by a 250-MeV proton beam using an ERBS measurement system that was sensitive to neutrons over the entire energy range being measured, i.e., thermal to 250 MeV. The authors used the neutron fluence spectrum to demonstrate experimentally the contribution of neutrons with different energies to the total dose equivalent and in particular the contribution of high-energy neutrons (≥20 MeV). These are valuable reference data that can be directly compared with Monte Carlo and experimental data in the literature.

07 ISOTOPE AND RADIATION SOURCES↗

Effects of (Al,Ge) double doping on the thermoelectric properties of higher manganese silicides

Experiments and analysis have been carried out to investigate the effects of Al and (Al,Ge) doping on the microstructure and thermoelectric properties of polycrystalline higher manganese silicide (HMS) samples, which were prepared by solid-state reaction, ball milling, and followed by spark plasma sintering. It has been found that Al doping effectively increases the hole concentration, which leads to an increase in the electrical conductivity and power factor. By introducing the second dopant Ge into Al-doped HMS, the electrical conductivity is increased, and the Seebeck coefficient is decreased as a result of further increased hole concentration. The peak power factor is found to occur at a hole concentration between 1.8 × 10{sup 21} and 2.2 × 10{sup 21} cm{sup −3} measured at room temperature. The (Al,Ge)-doped HMS samples show lower power factors owing to their higher hole concentrations. The mobility of Mn(Al{sub 0.0035}Ge{sub y}Si{sub 0.9965-y}){sub 1.8} with y = 0.035 varies approximately as T{sup −3/2} above 200 K, suggesting acoustic phonon scattering is the dominant scattering mechanism. The thermal conductivity of HMS does not change appreciably by Al or (Al,Ge) doping. The maximum ZT of (Al,Ge)-doped HMS is 0.57 at 823 K, which is similar to the highest value found in the Al-doped HMS samples. The ZT values were reduced in the Mn(Al{sub 0.0035}Ge{sub y}Si{sub 0.9965-y}){sub 1.8} samples with high Ge concentration of y = 0.025 and 0.035, because of reduced power factor. In addition, a two-band model was employed to show that the hole contribution to the thermal conductivity dominates the bipolar and electron contributions for all samples from 300 to 823 K and accounts for about 12% of the total thermal conductivity at about 800 K.

36 MATERIALS SCIENCE↗

H I, CO, and Planck/IRAS dust properties in the high latitude cloud complex, MBM 53, 54, 55 and HLCG 92 – 35. Possible evidence for an optically thick H I envelope around the CO clouds

We present an analysis of the H I and CO gas in conjunction with the Planck/IRAS submillimeter/far-infrared dust properties toward the most outstanding high latitude clouds MBM 53, 54, 55 and HLCG 92 – 35 at b = –30° to – 45°. The CO emission, dust opacity at 353 GHz (τ{sub 353}), and dust temperature (T {sub d}) show generally good spatial correspondence. On the other hand, the correspondence between the H I emission and the dust properties is less clear than in CO. The integrated H I intensity W{sub H} {sub I} and τ{sub 353} show a large scatter with a correlation coefficient of ∼0.6 for a T {sub d} range from 16 K to 22 K. We find, however, that W{sub H} {sub I} and τ{sub 353} show better correlation for smaller ranges of T {sub d} every 0.5 K, generally with a correlation coefficient of 0.7-0.9. We set up a hypothesis that the H I gas associated with the highest T {sub d} ≥ 21.5 K is optically thin, whereas the H I emission is generally optically thick for T {sub d} lower than 21.5 K. We have determined a relationship for the optically thin H I gas between atomic hydrogen column density and τ{sub 353}, N{sub H} {sub I} (cm{sup −2})=(1.5×10{sup 26})⋅τ{sub 353}, under the assumption that the dust properties are uniform and we have applied this to estimate N{sub H} {sub I} from τ{sub 353} for the whole cloud. N{sub H} {sub I} was then used to solve for T {sub s} and τ{sub H} {sub I} over the region. The result shows that the H I is dominated by optically thick gas having a low spin temperature of 20-40 K and a density of 40-160 cm{sup –3}. The H I envelope has a total mass of ∼1.2 × 10{sup 4} M {sub ☉}, an order of magnitude larger than that of the CO clouds. The H I envelope properties derived by this method do not rule out a mixture of H I and H{sub 2} in the dark gas, but we present indirect evidence that most of the gas mass is in the atomic state.

79 ASTRONOMY AND ASTROPHYSICS↗

Collisional Excitation of HCN by CO to Refine the Modeling of Cometary Comae

Here, we present the first dataset of collisional (de)-excitation rate coefficients of HCN induced by CO, one of the main perturbing gases in cometary atmospheres. The dataset spans the temperature range of 5–50 K. It includes both state-to-state rate coefficients involving the lowest ten and nine rotational levels of HCN and CO, respectively, and the so-called “thermalized” rate coefficients over the rotational population of CO at each kinetic temperature. The derivation of these coefficients exploited the good performance of the statistical adiabatic channel model (SACM) on top of an accurate interaction potential computed at the CCSD(T)-F12b/CBS level of theory. The reliability of the SACM approach was validated by comparison with full quantum calculations restricted at the lowest total angular momentum of the system. These results provide essential input to accurately model the distribution among the rotational energy levels and the abundance of HCN in cometary atmospheres, accounting for deviations from local thermodynamic equilibrium that typically occurs in such environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The “good,” the “bad,” and the “hidden” in neutron scattering and molecular dynamics of ionic aqueous solutions

We characterize a concentrated 7.3 m CaCl 2 solution, combining neutron diffraction with chloride isotopic substitution (Cl-NDIS) in null water and molecular dynamics (MD) simulations. We elucidate the solution structure, thermodynamic properties, and extent of ion pairing previously suggested as concentration-dependent and often not observed at lower concentrations. Our Cl-NDIS measurements designate the solvent-shared ion pairing as dominant and the contact ion pairing (CIP) as insignificant even under conditions close to the solubility limit. The MD models parameterized against neutron diffraction with calcium isotopic substitution (Ca-NDIS) overestimate CIP despite successfully reproducing most of the Cl-NDIS signal. This drawback originates from the fact that Ca 2+ –Cl - interactions were primarily “hidden” in the Ca-NDIS signal due to overlapping with Ca 2+ –O w and Ca 2+ –H w contributions to the total scattering. Contrary, MD models with moderate CIP and possessing generally good performance at high concentrations fail to reproduce the NDIS measurements accurately. Therefore, the electronic polarization, introduced in most of the recent MD models via scaling ionic charges, resolves some but not all parameterization drawbacks. We conclude that despite improving the quality of MD models “on average,” the question “which model is the best” has not been answered but replaced by the question “which model is better for a given research.” An overall “good” model can still be inappropriate or, in some instances, “bad” and, unfortunately, produce erroneous results. Additionally, the accurate interpretation of several NDIS datasets, complemented by MD simulations, can prevent such mistakes and help identify the strengths, weaknesses, and convenient applications for corresponding computational models.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗