Search NASA⌕ Search

SEARCH · Search NASA

Results for “trace elements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Major and trace element concentrations in samples from 72275 and 72255

Analytical data have been obtained for Co, Sc, Hf, Zn, Cr, Ga, Rb, Cs, Ni, major elements, and rare earth elements in eight samples from boulder 1. The data for trace elements were obtained by radiochemical neutron activation analysis. Major elements, except Na and Mn, were obtained by atomic absorption spectral photometry. Values for Na and Mn were obtained by neutron activation analysis of the same powder that was later dissolved to provide the atomic absorption analyses.

Haskin, L. A.↗

Major and trace element chemistry of separated fragments from a hibonite-bearing Allende inclusion

The major and trace elements of separated fragments and a bulk sample from CG-11, a hibonite-bearing inclusion in the Allende meteorite, were analyzed. Major element abundances were used to determine the minerology of separated fragments. The high degree of correlation between Eu/Sm ratios and Lu/Yb ratios for the samples studied indicates that their rare earth element (REE) distributions are governed by two components. One, Lu-, Eu-rich, is probably hibonite; the other, depleted in these elements, seems to be associated with the secondary alteration phases, grossular, nepheline and anorthite. The REE distribution in CG-11 precludes melting events after formation of the secondary alteration phases, but a melting event involving the primary minerals cannot be excluded. The enrichment of Lu with respect to other measured REE in hibonite can be explained by present REE condensation models. Two Hf-bearing components, most likely hibonite and perovskite, are necessary to account for variations in Sc/Hf ratios in the fragments studied. The lithophile volatiles Na, Mn, Fe, Zn, and probably Cr increase in the same order as the amount of secondary alteration minerals; the volatile siderophile elements Co and Au, however, do not.

Davis, A. M.↗

Experimental investigations of trace element fractionation in iron meteorites. III - Elemental partitioning in the system Fe-Ni-S-P

Measurements of solid metal/liquid metal trace element partition coefficients, which are used to interpret the crystallization history of magmatic iron meteorite groups differ greatly between different research groups, using different experimental techniques. Specifically, partition coefficients measured utilizing 'static' experiments which approach equilibrium cannot be reconciled with the results of 'dynamic' experiments which mimic fractional crystallization. We report new tests of our 'static' experimental technique and demonstrate that our methodology yields reliable equilibrium values for Ni, P and Ge partition coefficients. Partition coefficients in the Fe-Ni-S-P system are well matched by interpolation between the Fe-Ni-S and Fe-Ni-P subsystems. In contrast, the predictions of 'dynamic' experiments do not agree with our measurements and, consequently, the ability of 'dynamic' experiments to reproduce iron meteorite Ge vs. Ni fractionation trends successfully must be regarded as fortuitous.

Malvin, D. J.↗

Trace element content of chondritic cosmic dust: Volatile enrichments, thermal alterations, and the possibility of contamination

Trace element abundances in 51 chondritic Interplanetary Dust Particles (IDP's) were measured by Synchrotron X-Ray Fluorescence (SXRF). The data allow us to determine an average composition of chondritic IDP's and to examine the questions of volatile loss during the heating pulse experienced on atmospheric entry and possible element addition due to contamination during atmospheric entry, stratospheric residence, and curation.

Flynn, G. J.↗

X-ray fluorescence mapping of brain tissue reveals the profound extent of trace element dysregulation in stroke pathophysiology

Abstract The brain is a privileged organ with regard to its trace element composition and maintains a robust barrier system to sequester this specialized environment from the rest of the body and the vascular system. Stroke is caused by loss of adequate blood flow to a region of the brain. Without adequate blood flow ischaemic changes begin almost immediately, triggering an ischaemic cascade, characterized by ion dysregulation, loss of function, oxidative damage, cellular degradation, and breakdown of the barrier that helps maintain this environment. Ion dysregulation is a hallmark of stroke pathophysiology and we observe that most elements in the brain are dysregulated after stroke. X-ray fluorescence-based detection of physiological changes in the neurometallome after stroke reveals profound ion dysregulation within the lesion and surrounding tissue. Not only are most elements significantly dysregulated after stroke, but the level of dysregulation cannot be predicted from a cell-level description of dysregulation. X-ray fluorescence imaging reveals that the stroke lesion retains <25% of essential K+ after stroke, but this element is not concomitantly elevated elsewhere in the organ. Moreover, elements like Na+, Ca2+, and Cl− are vastly elevated above levels available in normal brain tissue (>400%, >200%, and >150%, respectively). We hypothesize that weakening of the blood–brain barrier after stroke allows elements to freely diffuse down their concentration gradient so that the stroke lesion is in equilibrium with blood (and the compartments containing brain interstitial fluid and cerebrospinal fluid). The change observed for the neurometallome likely has consequences for the potential to rescue infarcted tissue, but also presents specific targets for treatment.

Biochemistry & Molecular Biology↗

Estimate of contribution of jet aircraft operations to trace element concentration at or near airports

Samples of ASTM type A jet fuel were analyzed for trace element content by instrumental neutron activation techniques. Forty-nine elements were sought. Only ten, aluminum, gold, indium, lanthanum, titanium, vanadium, barium, dysprosium, tellurium, and uranium, were observed at levels above the detection limits encountered; of these only aluminum, titanium, and barium were present at concentrations greater than 0.1 ppm. Estimates of exhaust gas concentrations are made, and the ambient contribution at or near airports is calculated by using the Los Angeles International Airport dispersion model. It is shown that the ambient contribution is about an order of magnitude below typical urban levels for virtually all elements sought.

Fordyce, J. S.↗

Electron microprobe analysis of trace elements in minerals at 10 PPM concentrations

An improved technique is developed for measuring backgrounds during trace element analysis of crystals and glass using electron microprobes. This technique overcomes major difficulties encountered with conventional techniques, such as the problem of obtaining the net X-ray intensity of the characteristic emission line of interest with sufficient precision and accuracy, as well as the error due to the inability to directly measure the intensity at the wavelength of the characteristic line on the sample being analyzed. It is shown that this technique can yield reproducible results to within 4 ppm in olivine, and has a minimum uncertainty and detection limit of 10 ppm Nd in olivine.

Mckay, G. A.↗

International interlaboratory compilation of trace element concentrations in the CUP-2 uranium ore concentrate standard

Herein, a nuclear forensics investigation involving a uranium ore concentrate relies on accurate and precise analysis of impurities. Analytical data defensibility requires the use of reference materials as part of quality control. This study presents a compilation of trace element concentration results of the CUP-2 Uranium Ore Concentrate Standard measured by 11 different laboratories. The laboratories employed various dissolution methods, analytical preparation methods, and instrumental platforms. The data presented here contain concentrations of 66 impurities with up to 138 individual data points for each impurity. Consensus values have been assigned to each impurity following a statistical analysis of the data set.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Estimate of contribution of jet aircraft operations to trace element concentration at or near airports

Samples of ASTM type A jet fuel were analyzed for trace-element content by instrumental neutron activation techniques. Forty-nine elements were sought. Only ten, aluminum, gold, indium, lanthanum, titanium, vandium, barium, dysprosium, tellurium, and uranium, were observed at levels above the detection limits encountered; of these only aluminum, titanium, and barium were present at concentrations greater than 0.1 ppm. Estimates of exhaust gas concentrations are made, and the ambient contribution at or near airports is calculated by using the Los Angeles International Airport dispersion model. It is shown that the ambient contribution is about an order of magnitude below typical urban levels for virtually all elements sought.

Fordyce, J. S.↗

Preliminary analysis of an extensive one year survey of trace elements and compounds in the suspended particulate matter in Cleveland, Ohio

Preliminary review of a study of trace elements and compound concentrations in the ambient suspended particulate matter in Cleveland, Ohio, measured from August 1971 through June 1973, as a function of source, monitoring location, and meteorological conditions. The study is aimed at the development of techniques for identifying specific pollution sources which could be integrated into a practical system readily usable by an enforcement agency.

King, R. B.↗

Bulk, rare earth, and other trace elements in Apollo 14 and 15 and Luna 16 samples.

Measurement of 24 and 34 bulk, minor, and trace elements in lunar specimens by instrumental and radiochemical neutron activation analysis shows greater Al2O3, Na2O, and K2O abundances and higher TiO2, FeO, MnO and Cr2O3 depletions in Apollo 14 soil samples as compared to Apollo 11 samples and to most of Apollo 12 samples. The uniform abundances in 14230 core tube soils and three other Apollo 14 soils indicate that the regolith is uniform to at least 22 cm depth and within about 200 m from the lunar module.

Laul, J. C.↗

Equivalence of equations describing trace element distribution during equilibrium partial melting

It is shown that four equations used for calculating the evolution of trace-element abundances during equilibrium partial melting are mathematically equivalent. The equations include those of Hertogen and Gijbels (1976), Shaw (1970), Schilling (1971), and O'Nions and Clarke (1972). The general form to which all these equations reduce is presented, and an analysis is performed to demonstrate their mathematical equivalence. It is noted that the utility of the general equation flows from the nature of equilibrium (i.e., the final state is independent of the path by which that state is attained).

Consolmagno, G. J.↗

Enstatite chondrites - Trace element clues to their origin

Three EH and three EL chondrites have been subjected to RNAA analysis for 20 trace elements, and interelement correlations were examined in order to assess the effects of nebular fractionation and metamorphism. The refractory siderophiles Ir, Os, and Re correlate with the normal siderophiles Ni, Pd, Au, Sb, and Ge, in ELs but not in EHs. The two element groups presumably condensed on separate phases at first, but concentrated in metal during metabolism. Volatiles are consistently more depleted in ELs than EHs. Strong correlations are found for In-Tl, Tl-Bi, and Zn-Cd-In, which are equally consistent with predicted condensation curves for the solar nebula and with volatilization curves for artificially heated Abee. The three factors accounting for 93 percent of variance reflect volatile, siderophile, and chalcophile behavior.

Hertogen, J.↗