Search NASA⌕ Search

SEARCH · Search NASA

Results for “uniform methods project”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-C-9A-02: Structured Noise Index as An Automated Quality Control for Nuclear Medicine: A Two Year Experience

Purpose: Flood-field uniformity evaluation is an essential element in the assessment of nuclear medicine (NM) gamma cameras. It serves as the central element of the quality control (QC) program, acquired and analyzed on a daily basis prior to clinical imaging. Uniformity images are traditionally analyzed using pixel value-based metrics which often fail to capture subtle structure and patterns caused by changes in gamma camera performance requiring additional visual inspection which is subjective and time demanding. The goal of this project was to develop and implement a robust QC metrology for NM that is effective in identifying non-uniformity issues, reporting issues in a timely manner for efficient correction prior to clinical involvement, all incorporated into an automated effortless workflow, and to characterize the program over a two year period. Methods: A new quantitative uniformity analysis metric was developed based on 2D noise power spectrum metrology and confirmed based on expert observer visual analysis. The metric, termed Structured Noise Index (SNI) was then integrated into an automated program to analyze, archive, and report on daily NM QC uniformity images. The effectiveness of the program was evaluated over a period of 2 years. Results: The SNI metric successfully identified visually apparent non-uniformities overlooked by the pixel valuebased analysis methods. Implementation of the program has resulted in nonuniformity identification in about 12% of daily flood images. In addition, due to the vigilance of staff response, the percentage of days exceeding trigger value shows a decline over time. Conclusion: The SNI provides a robust quantification of the NM performance of gamma camera uniformity. It operates seamlessly across a fleet of multiple camera models. The automated process provides effective workflow within the NM spectra between physicist, technologist, and clinical engineer. The reliability of this process has made it the preferred platform for NM uniformity analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Sci-Fri AM: Quality, Safety, and Professional Issues 07: Global Medical Physics Efforts: Closing the Gap

Purpose: There is an increasing awareness of the disparity in Medical Physics needs between high income countries (HICs) and low-to-middle income countries (LMICs). This is especially evident with the growing incidence of cancer in LMICs. Projections from the recent Lancet Oncology Commission on Expanding Global Access to Radiotherapy indicate that an additional 22,000 Medical Physicists will be required by 2035 to provide uniform access to radiation therapy globally. This paper addresses possibilities and challenges associated with closing the Medical Physics gap between HICs and LMICs. Methods: Medical Physics and Oncology related organizations involved in providing support to enhance cancer therapy in LMICs were reviewed, especially as related to education, training and human resource development. Results: More than 35 organizations involved in addressing the cancer crisis in LMICs were found. Of these, 16 involve Medical Physics activities, with 7 being specific Medical Physics-related organizations. Ten of the 16 are involved in some LMIC activities with 6 having a major emphasis on LMIC contexts. Conclusions: The development of Medical Physics human resource capacity is a major challenge for LMICs. Fifty-five countries have no radiation therapy capabilities and by implication no capacity to train Medical Physicists. Overt attention with structured and altruistic actions by HIC contexts will help make inroads into the LMIC needs. Clear options throughout career structures in support of global health considerations combined with strong partnerships between interested parties in HICs and LMICs will enhance the development of safe and resource-appropriate strategies for advancing Medical Physics capabilities.

60 APPLIED LIFE SCIENCES↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogeneities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogeneities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogeneities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogenities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogenities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Physical performance and image optimization of megavoltage cone-beam CT

Megavoltage cone-beam CT (MVCBCT) is the most recent addition to the in-room CT systems developed for image-guided radiation therapy. The first generation MVCBCT system consists of a 6 MV treatment x-ray beam produced by a conventional linear accelerator equipped with a flat panel amorphous silicon detector. The objective of this study was to evaluate the physical performance of MVCBCT in order to optimize the system acquisition and reconstruction parameters for image quality. MVCBCT acquisitions were performed with the clinical system but images were reconstructed and analyzed with a separate research workstation. The geometrical stability and the positioning accuracy of the system were evaluated by comparing geometrical calibrations routinely performed over a period of 12 months. The beam output and detector intensity stability during MVCBCT acquisition were also evaluated by analyzing in-air acquisitions acquired at different exposure levels. Several system parameters were varied to quantify their impact on image quality including the exposure (2.7, 4.5, 9.0, 18.0, and 54.0 MU), the craniocaudal imaging length (2, 5, 15, and 27.4 cm), the voxel size (0.5, 1, and 2 mm), the slice thickness (1, 3, and 5 mm), and the phantom size. For the reconstruction algorithm, the study investigated the effect of binning, averaging and diffusion filtering of raw projections as well as three different projection filters. A head-sized water cylinder was used to measure and improve the uniformity of MVCBCT images. Inserts of different electron densities were placed in a water cylinder to measure the contrast-to-noise ratio (CNR). The spatial resolution was obtained by measuring the point-spread function of the system using an iterative edge blurring technique. Our results showed that the geometric stability and accuracy of MVCBCT were better than 1 mm over a period of 12 months. Beam intensity variations per projection of up to 35.4% were observed for a 2.7 MU MVCBCT acquisition. These variations did not cause noticeable reduction in the image quality. The results on uniformity suggest that the cupping artifact occurring with MVCBCT is mostly due to off-axis response of the detector and not scattered radiation. Simple uniformity correction methods were developed to nearly eliminate this cupping artifact. The spatial resolution of the baseline MVCBCT reconstruction protocol was approximately 2 mm. An optimized reconstruction protocol was developed and showed an improvement of 75% in CNR with a penalty of only 8% in spatial resolution. Using this new reconstruction protocol, large adipose and muscular structures were differentiated at an exposure of 9 MU. A reduction of 36% in CNR was observed on a larger (pelvic-sized) phantom. This study demonstrates that soft-tissue visualization with MVCBCT can be substantially improved with proper system settings. Further improvement is expected from the next generation MVCBCT system with an optimized megavoltage imaging beamline.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-EF-204-04: Feasibility Study of a Novel Stationary Spectral CT Scanner

Purpose: To evaluate a cadmium zinc telluride (CZT) detector module and to develop a proof-of-concept bench-top system to examine the concept and feasibility of a stationary spectral scanner that would consist of a CZT detector ring and a distributed source for rotationless imaging. Methods: The bench-top system employs a double-rotation set-up with two concentric but independent rotating stages, one for turning the object at sparse angles to mimic the imaging from a sequentially activated source distributed on a ring, while the other for translating the detector module to simulate a projection arc along a virtual detector ring. A source of 30-degree fan is used in the set-up, and the ring is designed to be 85cm in diameter in order to provide a 22cm field-of-view that is large enough for an average human head. The CZT detector module has 16×16 0.5mm pixels and eight global energy thresholds, and is attached to an experimental data acquisition board from the same vendor (Nova R&D). Its pixel gain is first calibrated using radioisotope Tc-99m to align the photo-peaks. Count rate performance is assessed using the X-ray source. Air and offset corrections are done prior to each CT scan. A 10cm acrylic phantom with 5 different inserts is imaged at 100kVp, 2mA, with an effective exposure window of 150ms per projection. Reconstruction is done using a total variation-type iterative method. Results: The detector module exhibited large gain variations among pixels. Average count rate was over 1Mcps per pixel. Parallax effect was observed along the arcs but was corrected. Reconstructed images from two energy bins demonstrated good contrast, spatial resolution and image uniformity, with little artifacts. Conclusion: The CZT detector tested is suitable for imaging relatively small objects. A stationary spectral CT appears feasible should we have enough buttable modules and a distributed source. This work was supported by Ministry of Science and Technology of China through grants 11YQ040082 and 2012BAI13B04.

60 APPLIED LIFE SCIENCES↗

Development of a scalable, robust electrocatalytic technology for conversion of CO 2 to formic acid via microstructured materials

This project was funded by the Bioenergy Engineering for Product Synthesis (BEEPS) program under the Funding Opportunity Announcement (FOA) DE-FOA-0001916 Topic Area 5 “Rewiring Carbon Utilization”. This FOA sought projects that would electrocatalytically reduce CO 2 to a carbon intermediate and then upconvert to a multi-carbon product or fuel via non-photosynthetic biological system engineering. The project sought to combine the expertise of OCO Chem, whose chief scientist had previously developed an efficient electrocatalytic reactor for conversion of CO 2 to formate with potential to scale, Montana State University investigators who had recently patented a method for laterally grading membranes with the potential of improving reactant distribution and more uniform efficiency across membrane-based reactors, and University of South Florida which had recently discovered a novel C-C bond forming reaction not known to naturally occur in biological systems and which uses C1 substrates and circumvents the central microbial metabolism.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Ten-Ecosystem Study - Landsat ADP mapping of forest and rangeland in the United States

The Ten-Ecosystem Study was designed to assess the maximum information content of Landsat data and its utility for large area classification using a uniform technical approach on the 10 generalized forest and rangeland ecosystems of the United States. Conclusions on the feasibility of using Landsat remote sensing automatic data processing methods, selecting the best seasons, analyzing costs and the effects of site complexity, miscellaneous analysis, problems, and recommendations were derived from 2 years of study, the project being three-fourths completed.

Kan, E. P.↗

Exploiting Colorimetry for Fidelity in Data Visualization

Advances in multimodal characterization methods fuel the generation of increasing immense hyper-dimensional data sets. Color mapping is employed for conveying higher dimensional data in two-dimensional (2D) representations for human consumption without relying on multiple projections. How one constructs these color maps, however, critically affects how accurately one perceives data. For simple scalar fields, perceptually uniform color maps and color selection have been shown to improve data readability and interpretation across research fields. In this work, we review core concepts underlying the design of perceptually uniform color maps and extend the concepts from scalar fields to two-dimensional vector fields and three-component composition fields frequently found in materials-chemistry research to enable high-fidelity visualization. Additionally, we develop the software tools PAPUC and CMPUC to enable researchers to utilize these colorimetry principles and employ perceptually uniform color spaces for rigorously meaningful color mapping of higher dimensional data representations. Last, we demonstrate how these approaches deliver immediate improvements in data readability and interpretation in microscopies and spectroscopies routinely used in discerning materials structure, chemistry, and properties.

36 MATERIALS SCIENCE↗

Microfocus x-ray imaging of traceable pointlike {sup 22}Na sources for quality control

Purpose: The purpose of this study is to propose a microfocus x-ray imaging technique for observing the internal structure of small radioactive sources and evaluating geometrical errors quantitatively, and to apply this technique to traceable pointlike {sup 22}Na sources, which were designed for positron emission tomography calibration, for the purpose of quality control of the pointlike sources. Methods: A microfocus x-ray imaging system with a focus size of 0.001 mm was used to obtain projection x-ray images and x-ray CT images of five pointlike source samples, which were manufactured during 2009-2012. The obtained projection and tomographic images were used to observe the internal structure and evaluate geometrical errors quantitatively. Monte Carlo simulation was used to evaluate the effect of possible geometrical errors on the intensity and uniformity of 0.511 MeV annihilation photon pairs emitted from the sources. Results: Geometrical errors were evaluated with sufficient precision using projection x-ray images. CT images were used for observing the internal structure intuitively. As a result, four of the five examined samples were within the tolerance to maintain the total uncertainty below {+-}0.5%, given the source radioactivity; however, one sample was found to be defective. Conclusions: This quality control procedure is crucial and offers an important basis for using the pointlike {sup 22}Na source as a basic calibration tool. The microfocus x-ray imaging approach is a promising technique for visual and quantitative evaluation of the internal geometry of small radioactive sources.

07 ISOTOPE AND RADIATION SOURCES↗

Anti-reflection Coatings on Large Area Glass Sheets

The first quarter of a one-year program designed to research and perfect a method of producing antireflective coatings on large glass sheets through the use of sodium silicate hardened by exposure to acid is reported. The requirements for a linear motion device used to produce uniform sodium silicate films were determined. A search for a commercially available device is underway. Sodium silicate solutions of varying concentrations were prepared. Determinations of the physical properties relevant to film thickness are in progress. In addition, material costs are being recorded for later use in a cost analysis of the method. All tasks of the project are proceeding according to schedule. Of the tasks, only the sodium silicate solution preparation is complete.

Pastirik, E.↗

A Method to Determine the Electric Field of Liquid Argon Time Projection Chambers using a UV Laser System and its Application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are today a standard detector technology for accelerator neutrino measurements, due to their high density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to drift ionization electrons to the anode to be collected. The E-field of a TPC is often assumed to be uniform between the anode and the cathode. However, significant distortions can appear from effects such as mechanical distortions, failures, or the accumulation of space charge generated by cosmic rays. The latter is particularly relevant for detectors placed near the Earth’s surface and with large drift distances. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TU-H-BRC-07: Therapeutic Benefit in Spatially Fractionated Radiotherapy (GRID) Using Helical Tomotherapy

Purpose: The aim of this project is to study the therapeutic ratio (TR) for helical Tomotherapy (HT) based spatially fractionated radiotherapy (GRID). Estimation of TR was based on the linear-quadratic cell survival model by comparing the normal cell survival in a HT GRID to that of a uniform dose delivery in an open-field for the same tumor survival. Methods: HT GRID plan was generated using a patient specific virtual GRID block pattern of non-divergent, cylinder shaped holes using MLCs. TR was defined as the ratio of normal tissue surviving fraction (SF) under HT GRID irradiation to an open field irradiation with an equivalent dose that result in the same tumor cell SF. The ratio was estimated from DVH data on ten patient plans with deep seated, bulky tumor approved by the treating radiation oncologist. Dependence of the TR values on radio-sensitivity of the tumor cells and prescription dose were also analyzed. Results: The mean ± standard deviation (SD) of TR was 4.0±0.7 (range: 3.1 to 5.5) for the 10 patients with single fraction dose of 20 Gy and tumor cell SF of 0.5 at 2 Gy. In addition, mean±SD of TR = 1±0.1 and 18.0±5.1 were found for tumor with SF of 0.3 and 0.7, respectively. Reducing the prescription dose to 15 and 10 Gy lowered the TR to 2.0±0.2 and 1.2±0.04 for a tumor cell SF of 0.5 at 2 Gy. In this study, the SF of normal cells was assumed to be 0.5 at 2 Gy. Conclusion: HT GRID displayed a significant therapeutic advantage over uniform dose from an open field irradiation. TR increases with the radioresistance of the tumor cells and with prescription dose.

60 APPLIED LIFE SCIENCES↗

Quantum Levitation of Fuel Capsules for Inertial Confinement Fusion

A major current challenge of the inertial confinement fusion (ICF) campaign is implosion perturbation due to fuel capsule support. Our current approach to hold ICF fuel capsules inside hohlraums is to sandwich a capsule between two thin polymeric films, referred to as tents. In addition to tents, variants of thin fibers have been used in some target designs to hold the capsule. Both tents and fibers cause strong implosion perturbations. An ideal solution to this problem is to hold the capsule inside the hohlraum by levitation, eliminating the perturbation-causing mechanical support. The goal of this project was to demonstrate a path to such an ideal capsule support solution based on quantum (superconducting) levitation. In our approach, the outer surface of the capsule is coated with a thin (about 100 nm) superconducting layer of MgB2, which is currently the most promising superconducting material candidate for this application. Magnetic coils outside the hohlraum are used to levitate and position the capsule in the center of the hohlraum. The scope of this project was limited to the first and arguably most critical step toward quantum levitation of ICF fuel capsules: the demonstration of thin-film superconductor coatings through a better understanding of the physics of defect- and interface-dominated superconducting behavior of ultrathin films. Specific objectives were (i) to develop a method for deposition of smooth and uniform thin films of MgB2 on ICF-scale spherical capsules; (ii) to better understand effects of film thickness, interfaces, and lattice defects on superconducting properties of MgB2; (iii) to perform cryogenic levitation experiments; and (iv) to develop a levitation model. All these objectives were met.

36 MATERIALS SCIENCE↗

Determining the Effects of Neutron Irradiation on the Structural Integrity of Additively Manufactured Heat Exchangers for Very Small Modular Reactor Applications, DOE Final Report (Project # 19-16980)

Auburn University (AU) teamed with the University of Missouri Research Reactor (MURR) and Kansas State University (KSU) to determine how to best use laser-powder bed fusion (L-PBF) additive manufacturing (AM) methods for generating radiation resistant nickel-based superalloys, Inconel alloy 625 and 718, for special purpose reactor (SPR) or very small modular reactor (vSMR) heat-exchangers (HeXs). Compact, conformal, and durable HeXs that are tolerant of extreme environments are needed for supporting the technical maturity of next-generation, portable compact reactors. AM is an enabler for realizing this new wave of HeXs – providing a means to make customizable hot and cold stream architectures with novel flow path geometries (e.g., tortuous channels with non-uniform, asymmetric cross-sections) and reduced layer-to-layer contact resistance (i.e., no separate bonding procedure required). AM further enables a more time/cost efficient means for fabricating SPRs by reducing the number of suppliers required for HeX assembly and allowing for on-site HeX fabrication. The project aim has been to better understand how neutron irradiation affects the microstructure and properties of additively manufactured nickel-based superalloys, to accelerate their safe, reliable use in the modular reactor industry. The major objective was to qualify/quantify the microstructure and microhardness of nickel-based superalloys (including Inconel 718 and 625) additively manufactured via the L-PBF process in the neutron-dosed (irradiated) and non-irradiated states over a course of 3 years. Effects of build orientation during L-PBF and post-AM heat treatments on neutron resistance, microstructure and mechanical properties were also investigated. Neutron damage mechanisms via hardening were characterized. This project combined subject-matter experts in AM, mechanical/microstructure metallic part characterization, and neutron irradiation, as well as unique assets and capabilities at AU and MURR at MU, to ensure project results translated to effectively addressing known gaps in nuclear science and engineering. Parts were fabricated using L-PBF systems readily available at AU. Specimens were then irradiated using MURR facilities; a manipulator equipped hot cell was also used to measure material hardness after dosing. MURR, a 10 MW, light-water nuclear reactor, is the largest, highest powered, highest-flux university owned research reactor in the U.S. The major findings in this project provide evidence that AM can serve as an alternative way to build structural components for future advanced small modular reactors using advanced materials like Inconel 625 (IN625) or Inconel 718 (IN718). After full spectrum neutron irradiation, vertically as-built AM IN625 samples were observed to display better resistance towards radiation-induced-hardening defects relative to traditionally machined metals. A Vickers microhardness tester, using settings of 1 kgf and dwell time of 15 seconds per indentation, was used to measure hardness in this study. The as-built, vertically printed samples experienced 1.2% of radiation hardening vs. 5.25% radiation hardening observed in wrought IN625. Another set of IN625 and IN718 samples were exposed to fast neutron irradiation. It was observed that IN718 showed more resistance towards radiation hardening compared to IN625 samples indicating IN718 had a better performance. Results showed that the IN718 samples experienced less change (-2.5 to 3.24 %) in microhardness. On the other hand, IN625 samples underwent more (0.9 to 7.21%) change in microhardness after fast neutron irradiation. AM IN625 samples were irradiated using an ion (proton) beam in cyclotron. The mechanical properties of AM samples post irradiation were compared with wrought samples. The irradiated region on the samples were tested using nano-hardness indention. It was observed that the beam current and time used in this study generated an annealing effect and thus reduced the hardness of the samples. The sum of the project results provide precious insight into how one may minimize radiation hardening in AM materials while maintaining material property constraints. Results should assist engineers in selecting an appropriate heat treatment for AM nickel-based superalloys for increased radiation resistance. Results should increase confidence levels for adopting AM for building nuclear reactor components which perform the same or better than conventionally manufactured components. Fast neutron irradiation testing provided an accelerated means of obtaining radiation effects without making materials radioactive and difficult to handle.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗