Search NASA⌕ Search

SEARCH · Search NASA

Results for “utility meter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM's existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

batteries↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data

Many distribution network monitoring and control applications - including state estimation, Volt/VAr optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder-head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure (AMI)↗

Risk-informed Hierarchical Control of Behind-the-Meter DERs with AMI Data Integration (Final Technical Report)

This project addresses several key barriers to implement the next generation demand response applications and provides a clear understanding of implementing hierarchical and standalone control using AMI data. Through this program, Eaton has developed and tested a meter-as-a-controller prototype with the help of other partners--- National Renewable Energy Laboratory (NREL), Electric Power Research Institute (EPRI), Pecan St Inc. (PSI), and Delaware Electric Cooperative (DEC). The controller can utilize residential controllable loads such as heating, ventilation, and air conditioner (HVAC), electric water heater and distributed energy resources like solar PV and battery energy storage systems for off-setting the demand that is required from the grid, thus providing reliable grid-services for demand reduction or peak shaving. The controller is also capable of coordinating the resources of the premises for better management and energy efficiency while meeting the comfort bound of the premises owner as quality-of-service. The development has been demonstrated in a three virtual-home setup at system performance lab of NREL with real appliances (HVAC, electric water heater, solar PV, and battery). The technology has also been proved through laboratory and field demonstration with successful interconnectivity (e.g., end-to-end communication and data exchange) between the residential appliances and utility through the RF network at Delaware Electric Co-op (DEC) in Delaware.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase Identification in Real Distribution Networks with High PV Penetration Using Advanced Metering Infrastructure Data: Preprint

Many distribution network monitoring and control applications - including state estimation, volt/VAR optimization, and network reconfiguration - rely on accurate network models; however, the network models maintained by utilities can become outdated because of restoration activities, network reconfiguration, and missing data. With the widespread deployment of advanced metering infrastructure (AMI), abundant measurement data from low-voltage secondary networks are available. The AMI measurement data can be used for phase identification to improve the network models. Although the existing phase identification techniques work well in passive distribution feeders that do not have photovoltaic (PV) generation, they can fail to accurately identify the phases in the presence of PV. This paper proposes a robust phase identification algorithm based on supervised machine learning that accurately identifies the AMI meter phase connectivity in the presence of significant PV generation. The proposed algorithm does not require network topology information or feeder head measurement data. The algorithm is validated using the AMI measurement data collected in the field and the field-validated phase connectivity database on two real distribution feeders from San Diego Gas & Electric Company that have significant PV generation.

advanced metering infrastructure↗

Implications of Battery Storage for Solar Net-Metering Reforms

Compensation structures for residential solar PV are evolving toward a model that incentivizes the use of battery storage to maximize solar self-consumption. Using metered data from 1,800 residential customers across six U.S. utilities, we show that batteries operated solely in this manner often provide no grid value, due to misalignment with market prices. Incentivizing customers to discharge storage in response to market prices, particularly on infrequent peak load days would greatly enhance storage dispatch value. However, doing so requires consideration of local distribution network impacts. We illustrate a net billing design that yields a storage dispatch value equal to 50-70% of its maximum potential market value, without materially degrading solar self-consumption levels or increasing local grid stress.

Barbose, Galen↗

Plant Characteristics, Porewater, Gas Flux, and Soil Biogeochemistry at Council Road Site Mile Marker 71, Seward Peninsula, Alaska, 2023

Data collected at Council, AK (64°51’35.0”N 163°41’59.1”W) during a summer campaign in 2023. Water data consists of soil porewater collected by centrifuging soil cores and also by field collection with porewater samplers (rhizons). Gas data consists of CO2, CH4 and N2O surface soil fluxes measured with a portable FTIR analyzer. Plant and root data consists of biomass, root length, diameter and mass. Soil data consists of total C and N. Air, water and soil samples span two main locations: a thermokarst wetland and an upland tussock. The Next-Generation Ecosystem Experiments: Arctic (NGEE Arctic), was a research effort to reduce uncertainty in Earth System Models by developing a predictive understanding of carbon-rich Arctic ecosystems and feedbacks to climate. NGEE Arctic was supported by the Department of Energy's Office of Biological and Environmental Research.The NGEE Arctic project had two field research sites: 1) located within the Arctic polygonal tundra coastal region on the Barrow Environmental Observatory (BEO) and the North Slope near Utqiagvik (Barrow), Alaska and 2) multiple areas on the discontinuous permafrost region of the Seward Peninsula north of Nome, Alaska. Through observations, experiments, and synthesis with existing datasets, NGEE Arctic provided an enhanced knowledge base for multi-scale modeling and contributed to improved process representation at global pan-Arctic scales within the Department of Energy's Earth system Model (the Energy Exascale Earth System Model, or E3SM), and specifically within the E3SM Land Model component (ELM).This dataset was generated to broadly address the following research question: how will climate change (i.e., thawing permafrost, landscape change) alter the ecosystem flux (sink versus source) of important greenhouse gases such as CO2, CH4 and N2O?Description of the contents of this data package: This dataset contains 5 different individual .csv files containing plant, soil, water and gas data. No software is needed to utilize them. PFTCover: Plant functional type ground cover in 1x1 meter plots. SoilCores: Solidphase and porewater phase soil biogeochemical variablesPlantData: Above and belowground plant traits. GasFlux: Surface plant-soil gas measurementsFieldPorewater: Field collected porewater biogeochemical variables

54 ENVIRONMENTAL SCIENCES↗

Helium-3 Piping and Gas Handling Implementation for the Colossus milli-Kelvin Platform at Fermilab

Colossus is a large millikelvin platform that has a two-meter diameter mixing chamber plate. This uniquely large millikelvin platform utilizes a cryogenics plant to maintain progressively lower temperatures at each of the three upper stages and precool the lower three stages of the system. At the millikelvin stages, Colossus employs multiple commercially available dilution units to achieve millikelvin temperatures at the 100 mK and 20 mK stages. The incoming helium-3/helum-4 process fluid mixture for each dilution unit flows through tubes wrapped around copper posts attached to each of the upper stages of the system. These tubes function as capillary heat exchanger to reduce the temperature of the incoming helium mixture to the appropriate temperature at each stage.

James, C.↗

Reese Housing Power Project (Final Technical Report)

The Reese Housing Power Project is located on Tribal trust land in Colusa, CA and expands existing medium-voltage distribution to seven new households with the addition of medium-voltage cabling, step down transformers, smart meters, and street lighting for the new development. The Tribe utilized their existing Co-Generation power plant and micro grid to supply the new homes with highly reliable power with fewer interruptions and at a reduced rate compared with the local utility. The project gives the Tribe greater independence from traditional power sources and provides jobs for the community. The project reduces electric energy costs, increases Tribe self-reliance, and provides highly reliable electric power to seven tribal members’ homes. Construction of the project also provided jobs for the community.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Behind-the-Meter Energy Storage and Generation in Support of Electrified Rental Car Centers

Electrification of rental car centers at major airports is expected to generate tens of MW in additional power loads. The magnitude of these loads poses challenges including high utility costs, expensive and lengthy distribution capacity upgrades, and disruptions to traditional operation. Behind-the-meter stationary battery storage and onsite photovoltaic generation offer a viable solution to these challenges without impacting the operation and business model of rental car companies, defined by minimal fleet inventory and short vehicle dwell time. Using data-driven syn-thetic charging loads for the rental car center at the Dallas/Fort Worth airport in the United States, we show that optimally-designed and controlled behind - the- meter resources can reduce the lifecycle cost of electrified rental centers by an average 41 % and reduce peak grid demand by 64 %, deferring the need for distribution upgrades or potentially avoiding it altogether.

battery storage↗

Comparison of gamma-ray spectral analysis methods for thick-walled UF 6 cylinders

Three data analysis methods were compared for gamma ray spectra collected by planar and coaxial high-purity germanium detectors (HPGe) on thick-walled uranium hexafluoride cylinders. The cylinder contents range from natural to low-enriched uranium (4.95% 235 U). Each spectrum was analyzed with the traditional 185.7 keV enrichment meter method, a 185.7/1001 keV ratio method, and the Fixed Energy Response Function Analysis with Multiple Efficiency (FRAM) software that utilizes low- and high-energy gamma rays and X-rays. When results for all cylinders were compared, the enrichment meter method and the 185.7/1001 keV peak ratio method consistently provided the most accurate data for all detector types. The error on the enrichment calculations analyzed with FRAM did not meet the international target value whereas those calculated with the enrichment meter and ratio method did. Enrichments calculated by FRAM were found to skew to higher values on natural uranium and to lower values on low-enriched uranium. FRAM calculated the least-precise enrichments; replicate analyses of single cylinders resulted in 235 U values that varied by as much as 19%. FRAM does have the significant advantages in that it does not require the use of calibration cylinders, infinite thickness criteria are not necessary, and it can be applied to any HPGe detector. Finally, if calibration cylinders are available, the enrichment meter and 185.7/1001 peak ratio are the recommended methods as they are the most accurate and precise.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integration of a DER Management System in Riverside. Final report

The tasks in this project covered various aspects, including algorithm development, algorithm integration into a commercial Active Network Management (ANM) platform, hardware-in-the-loop (HIL) testing in an industry-standard testing platform, pilot demonstration in Riverside, California, and also cost and benefit analysis. The DERMS platform in this project can host different algorithms developed on different platforms (e.g., MATLAB and Python) and it can interact with different hardware devices (e.g., different PV inverters, battery inverters, and different sensors). The DER control solution are based on an advanced model-free, layered, and clustered DER control paradigm. At the core of the DER control algorithms was the concept of Extremum Seeking (ES), which is a model-free probing-based control technique. The ES-based control algorithms were tested on major real-world inverters; both individually and in a cluster. It was shown that even legacy equipment (or when paired with a few additional advanced equipment) can support such advanced control. The monitoring algorithms utilize a heterogeneous set of legacy and advanced sensor measurements, such as behind-the-meter DER sensors, distribution-level Phase Measurement Units, distribution-substation Supervisory Control and Data Acquisition (SCADA), and line current sensors, with their limited availability; in order to infer practical network conditions. Sensor data are utilized to achieve resource forecasting, phase identification, and distribution system state estimation. The technology that was developed and demonstrated in this project could be transformational to utilities, including the smaller municipal utilities such as in Riverside, which may not have the resources to deploy advanced distribution system and DERMS solutions in order to support high penetration of solar power integration. This project created a real-world prototype to provide utilities with an assessment of smart grid monitoring and control technologies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An Overview of Behind-the-Meter Solar-Plus-Storage Regulatory Design: Approaches and Case Studies to Inform International Applications

Behind-the-meter energy storage systems paired with distributed photovoltaic (DPV) - with the capability to act as both generation and load - represent a unique and disruptive power sector technology capable of providing a range of important services to customers, utilities, and the broader power system. How should regulators, utilities, and policymakers manage the range of challenges and opportunities that increased behind-the-meter energy storage deployment will bring to the power system, in particular when these systems are paired with DPV? This report is intended to offer key regulatory considerations for facilitating DPV-plus-storage programs for retail customers; relevant cases from U.S. states are provided as examples of how novel regulatory issues related to behind-the-meter energy storage systems paired with DPV are being addressed in practice. At a high level, designing a regulatory framework that aligns DPV-plus-storage deployment with larger policy objectives requires thoughtful deliberation across a range of technical and economic issues. While this report attempts to segment many of these issues into distinct topics to enhance reader understanding, in reality, DPV-plus-storage regulatory issues are all closely integrated, and design decisions on a single aspect often have broader implications. With that in mind, this report outlines a series of steps that can be employed by regulators to approach DPV-plus-storage regulatory design.

14 SOLAR ENERGY↗

Calculating Behind-the-Meter Energy Storage Incentives on an Avoided Cost Basis

Behind-the-meter (BTM) energy storage offers the potential for shared investment by utilities and their customers, in which both parties share in the costs and benefits of battery investment. Several utilities and a handful of states have begun providing incentives to help customers purchase BTM energy storage, and in exchange, operate that battery on behalf of the customer to realize grid benefits such as meeting peak capacity needs. But there is wide variation in the value and structure of these incentives, suggesting a lack of clarity on the value of BTM storage to the grid and to non-participating customers who fund the incentives for participating customers. This paper provides an objective framework for establishing BTM energy storage incentives based on the avoided cost of generation from a marginal, gas-fired peaking plant. It also conducts several sensitivity analyses to see how those avoided costs vary with emissions pricing, gas prices, plant heat rates, and utility capital structures. This work may be of use to utilities, regulators, and energy system stakeholders in providing a value-based framework for BTM incentive programs that can be used in the absence of policy guidance.

Twitchell, Jeremy B.↗

Assessing Cost-Optimal Battery Energy and Solar-Plus-Storage Systems for Federal Customers: A Nationwide Assessment: Preprint

Prior research has identified that the financial viability of behind-the-meter battery energy storage systems is heavily dependent on technology cost, utility rate structure, energy consumption patterns, and co-deployment with synergistic technologies like solar photovoltaics (PV), among other factors. This study builds on existing research by comprehensively evaluating the economics of battery energy storage systems (BESS) and solar-plus-storage systems for a reference office building at 755 reference sites under 834 utility rates, and four storage capital cost scenarios. Results indicate that even with dramatic cost reductions, BESS is likely to be cost-effective only under utility rates that include demand charges, and possibly include time-of-use (TOU) pricing as well. Even under these utility rates, BESS systems provide marginal savings, and office building operators are unlikely to deploy the technology for cost savings alone. Solar-plus-storage systems provide more savings than BESS and allow for larger economic storage capacities. Solar-plus-storage provides compelling savings opportunities at baseline prices, and even at capital costs 25% higher than baseline. Solar-plus-storage is most effective where there are demand charges and energy pricing schemes include TOU pricing, or where electricity is expensive (at least $0.30/kWh). Our case studies illustrate that the presence of demand charges, even at similar energy costs, can be the deciding factor in BESS and solar-plus-storage viability. The findings and maps from this assessment may be of use to planners, building owners, and developers looking for potentially economic storage opportunities.

battery energy storage systems↗

Standoff Detection of Oil and Powder Mixtures at 12 Meters Using a Tunable Quantum Cascade Laser-Based System with a Close Focus Telescope and Uncooled Infrared Detector

We have designed and demonstrated a quantum cascade laser (QCL) based standoff system that utilizes an uncooled mercury cadmium telluride (MCT) detector with lock-in signal processing for chemical identification at a distance of 12.5 meters in indoor ambient light conditions. In the system, a tunable quad-QCL operating (1 MHz) in quasi-continuous wave mode between 8.45 and 10.03 μm (~1182 to 1000 cm –1 ) serves as the active mid-infrared source for remotely interrogating mineral, powder, and thin film oil samples including powder mixtures (6, 12.5, 25, and 50%) of crystalline quartz (SiO 2 ) in KBr. Light as reflected from a given sample is collected using a 10-inch (25.4 cm) Dall Kirkham telescope and coupled with ZnSe optics to an uncooled MCT detector. Furthermore, the mixture dependence of the highly transparent KBr and strongly absorbing quartz was found to fit a modified version of the Schatz reflectance model for compacted powder mixtures. All reflectance spectra reported are relative to an Au-coated diffuse reflector. A NIST traceable polystyrene standard reflector was also used to determine the QCL wavelength tuning range and calibration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Community-scale interaction of energy efficiency and demand flexibility in residential buildings

Demand-side management (DSM) strategies, including energy efficiency (EE) and demand flexibility (DF), contribute to cost-effective operation of the electricity grid. From a system-level perspective, such programs reduce costs, enhance reliability, and reduce network issues. Similarly, DSM programs help participating customers reduce utility bills while maintaining occupant comfort. Understanding the relationship between EE and DF is key to realizing the full potential of DSM programs. In this study, we modeled an all-electric residential community based on a 498-home community that is planned for construction in Fort Collins, Colorado in the United States. We used this community model to study the relationship between different EE measures, including building envelope upgrades and smart appliances, and DF enabled by a home energy management system (HEMS) responding to a time-varying tariff. Various EE levels in the homes – code-minimum, zero energy ready, and even higher levels of envelope efficiency – were simulated. DF is enabled by the HEMS, which coordinates behind-the-meter resources, including flexible building loads, PV, and home battery systems, to minimize utility bills while maintaining occupant comfort. When comparing to the code-minimum homes, EE upgrades alone reduce HVAC energy use during peak hours by up to 50% and the HVAC utility bill by up to $312/year. With the addition of HEMS, the average daily peak demand can be reduced by up to 0.58 MW or 1.2 kW/home in the higher envelope efficiency homes. The combination of EE upgrades, HEMS, and home battery systems is expected to save homeowners up to $590/year while increasing community load flexibility. However, HEMS and home battery systems are less effective in increasing the DF in the more efficient homes due to the lower load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Clustering Interval Load with Weather to Create Scenarios of Behind-the-Meter Solar Penetration

Forecasting load at the feeder level has become increasingly challenging with the penetration of behind-the-meter solar, as this self-generation is only visible to the utility as aggregated net-load. This work proposes a methodology for creation of scenarios of solar penetration at the feeder level for use by forecasters to test the robustness of their algorithm to progressively higher penetrations of solar. The algorithm draws on publicly available observations of weather condition (e.g., rainy/cloudy/fair) for use as proxies to sky clearness. These observations are used to mask and weight the interval deviations of similar native usage profiles from which average interval usage is calculated and subsequently added to interval net generation to reconstruct interval total generation. This approach improves the estimate of annual energy generation by 23%; where the net generation signal currently reflects 52% of total annual gener- ation, now 75% is captured. This methodology for creation of forecast testing scenarios is data driven and extensible to service territories which lack information on irradiance measurements and geocoordinates.

solar, load↗