Search NASA⌕ Search

SEARCH · Search NASA

Results for “validation method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Comparison and validation of the QuEChERSER mega-method for determination of per- and polyfluoroalkyl substances in foods by liquid chromatography with high-resolution and triple quadrupole mass spectrometry

Instances of food contamination with per- and polyfluoroalkyl substances (PFAS) continue to occur globally, but sample preparation and analytical methods are quite limited and often monitor for a small percentage of known PFAS. This study aimed to evaluate, validate, and compare performance of two instruments with the recently developed “quick, easy, cheap, effective, rugged, safe, efficient, and robust” (QuEChERSER) sample preparation mega-method – a method developed to monitor chemicals over a broad range of physicochemical properties. Initial evaluation of the QuEChERSER mega-method for determination of PFAS in food demonstrated recoveries, matrix interferences, and co-extractive removal comparable to (or better than) US Food and Drug Administration (FDA) and USDA Food Safety and Inspection Service (FSIS) methods. Subsequent validation of QuEChERSER in beef, catfish, chicken, pork, liquid eggs, and powdered eggs on a high-resolution mass spectrometer achieved acceptable recoveries (70–120%) and precision (RSDs ≤20%) for all 33 target analytes at the 1 and 5 ng g –1 levels and 67–88% of analytes at the 0.1 ng g –1 level, depending on the matrix. Additional validation was performed by tandem mass spectrometry on a triple quadrupole instrument. This approach provided no non-detects and better recoveries at the 0.1 ng g –1 level than the HRMS method but exhibited more variability at 1 and 5 ng g –1 spiking levels. Analysis of NIST SRMs 1946 and 1947 gave accuracies of 70–117%. Furthermore, these results demonstrate the capability of combining PFAS analysis with a mega-method previously validated for 350 analytes, while collecting non-target data for future retrospective analysis of emerging alternatives with a high-resolution mass spectrometry method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Hydraulics Validation Activities in the ART-GCR Campaign

The Advanced Reactor Technologies - Gas Cooled Reactor Campaign (ART-GCR) is part of the United States Department of Energy - Office of Nuclear Energy's Advanced Reactor Technologies program aimed at developing a High Temperature Gas-cooled Reactor (HTGR) which will offer enhancements in safety and efficiency. The Design, Methods, and Validation arm of the ART-GCR program provides experience and advanced tools for HTGR design and analysis. The Methods and Validation arm is developing data to validate predictions of decay heat removal through an extensive experimental campaign the Natural Convection Shutdown Heat Removal Test Facility at Argonne National Laboratory. In-core thermal hydraulics validation is being facilitated through the OECD/NEA's Thermal Hydraulic Code Validation Benchmark for High Temperature Gas-Cooled Reactors using HTTF Data. That benchmark contains code-to-code and code-to-data comparisons for 3 sets of HTGR thermal hydraulics phenomena. This ongoing benchmark activity has 16 participants from 9 countries developing leading insights into HTGR thermal hydraulics code validation. The ART-GCR campaign is also working on the development of state-of-the-art MOOSE-based models of the High Temperature Engineering Test Reactor (HTTR). Through the OECD/NEA's HTTR Loss of Forced Cooling (LOFC) program, the ART-GCR campaign is developing a multiphysics transient code validation benchmark based on 3 HTTR experiments that will provide an opportunity for international collaboration on multiphysics code validation.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Synthetic High Impedance Fault Data through Deep Convolutional Generated Adversarial Network

High impedance faults (HIFs) have always been significant challenge in the power grids. Researchers have developed some advanced protective methods to detect the HIFs. To test and validate these methods, large amounts of HIF data are required. This paper presents a synthetic HIF data generating method using the deep convolutional generated adversarial network (DCGAN). The DCGAN includes a generator module to create synthetic HIF waveform from random noises; and a discriminator module to identify the flaws of those synthetic data, which ultimately help improve the quality of the synthetic data created by the generator. To test the fidelity of the generated synthetic HIF data, two different HIF-detection methods have been applied. Extensive simulation results have validated the effectiveness of using the DCGAN to create synthetic HIF data.

Yang, Kun↗

Updated Guidance on Sensitivity/Uncertainty Methods Use for Nuclear Criticality Safety Validation

The use of sensitivity/uncertainty (S/U) methods in nuclear criticality safety (NCS) was established more than 25 years ago and has been increasing ever since. Recent interest in commercial applications involving uranium enrichments above 5 wt% 235 U has increased focus on demonstrating the applicability of existing critical experiments to this enrichment range. S/U techniques can also be particularly useful in assessing the similarity of new fuel forms in relation to those documented in existing published evaluations of benchmark critical experiments. Publishing updated recommendations for the use of these methods is thus important to ensure that new S/U practitioners can benefit from the years of development and application invested in generating a set of best practices to maximize the utility of these tools.

NCS↗

A semi–automatic analytical methodology for characterizing the energy consumption of MRI systems using load duration curves

Background and purpose: Magnetic resonance imaging (MRI) scanners are a major contributor to greenhouse gas emissions from the healthcare sector, and efforts to improve energy efficiency and reduce energy consumption rely on quantification of the characteristics of energy consumption. The purpose of this work was to develop a semi-automatic analytical methodology for the characterization of the energy consumption of MRI systems using only the load duration curve (LDC). LDCs are a fundamental tool used across various fields to analyze and understand the behavior of loads over time. Methods: An electric current transformer sensor and data logger were installed on two 3T MRI scanners from two vendors, termed M1 (outpatient scanner) and M2 (inpatient/emergency scanner). Data was collected for 1 month (7/11/2023 to 8/11/2023). Active power was calculated, assuming a balanced three-phase system, using the average current measured across all three phases, a 480 V reference voltage for both machines, and vendor-provided power factors. An LDC was constructed for each system by sorting the active power values in descending order and computing the cumulative time (in units of percentage) for each data point. The first derivative of the LDC was then computed (LDC’), smoothed by convolution with a window function (sLDC’), and used to detect transitions between different system modes including (in descending power levels): scan, prepared-to-scan, idle, low-power, and off. The final, segmented LDC was used to measure time (% total time), total energy (kWh), and mean power (kW) for each system mode on both scanners. The method was validated by comparing mean power values, computed using the segmented 1-month LDC, for each nonproductive system mode (i.e., prepared-to-scan, idle, lower-power, and off) against power levels measured after a deliberate system shutdown was performed for each scanner (1 day worth of data). Results: The validation revealed differences in mean power values <1.4% for all nonproductive modes and both scanners. In the scan system mode, the mean power values ranged from 29.8 to 37.2 kW and the total energy consumed for 1 month ranged from 11 106 to 14 466 kWh depending on the scanner. Over the course of 1 month, the portion of time the scanners were in nonproductive modes ranged from 76% to 80% across scanners and the nonproductive energy consumption ranged from 8010 to 6722 kWh depending on the scanner. The M1 (outpatient) scanner consumed 99.9 and 183.9 kWh/day in idle mode for weekdays and weekends, respectively, because the scanner spent 23% more time proportionally in idle mode on the weekends. Conclusions: A semi-automatic method for quantifying energy consumption characteristics of MRI scanners was introduced and validated. This method is relatively simple to implement as it requires only power data from the scanners and avoids the technical challenges associated with extracting and processing scanner log files. Finally, the methodology enables quantitative evaluation of the power, time, and energy characteristics of MRI scanners in scan and nonproductive system modes, providing baseline data and the capability of identifying potential opportunities for enhancing the energy efficiency of MRI scanners.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Cyber-attack Detection in Photovoltaic Farms

Here, to address the cyber-physical security in PV farms, a hybrid cyber-attack detection is proposed in this manuscript. To secure PV farms, the proposed method integrates model-based and data-driven methods by fusing the detection score at the device and system levels. First, a model-based cyber-attack detection method is developed for each PV inverter. A residual between the estimation of the Kalman filter and measurement is calculated. By leveraging the calculated residual from all inverters, a squared Mahalanobis distance is developed for device detection score generation. At the system level, a convolutional neural network (CNN) is proposed to detect cyber-attack using the waveform data at the point of common coupling (PCC) in PV farms. To improve the CNN detection accuracy, a set of well-designed features are extracted from the raw waveform data. Finally, a weighted detection score fusion method is proposed to combine device and system detection scores by using their complementary strength. The feasibility and robustness of the proposed method are validated by testing cases and a comparative experiment.

14 SOLAR ENERGY↗

A corrected method for Coulomb scattering in arbitrarily weighted particle-in-cell plasma simulations

A physically and statistically accurate method to perform binary, pairwise Coulomb collisions for arbitrarily-weighted macroparticles in particle-in-cell simulations is described. The method is shown to conserve global energy and momentum on average and to produce physically accurate scattering frequencies. This is justified using the statistically expected values of the method and through a series of numerical tests showing that the method is valid independently of macroparticle weight. This novel method is required due to an error in previous work on binary scattering, initially by Nanbu and Yonemura [J. Comp. Phys. 145, 639 (1998)] and applied to subsequent work, that causes inaccuracies in the scattering frequencies for unequally weighted simulations; a problem that occurs both for scattering within the group and between different groups.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A conservative, interface-resolved, compressible framework for the modeling and simulation of liquid/gas phase change

This paper presents a method for simulating evaporation in a compressible, interface-resolved framework appropriate for modeling problems of engineering interest. In order to achieve robustness and broad applicability, the method has been designed to discretely enforce consistent mass and thermal energy transport at the phase interface, to globally conserve mass, momentum, and energy, and to be capable of modeling compressible and incompressible systems. Verification is performed via the Sod-shock test, one-dimensional heat conduction, evaporation from a planar interface, and evaporation of three-dimensional droplets. Convergence with increasing mesh resolution is demonstrated in all tested configurations, and conservation is maintained near machine precision for a translating droplet. Conservation and accurate phase change rates are preserved at the low numerical resolutions commonly encountered in engineering calculations. Following verification, the method is validated by comparison to an empirical correlation for evaporating droplets in high temperature crossflow, and the presentation concludes with the simulation of an iso-octane spray at conditions representative of gasoline direct injection. In conclusion, successful verification, validation, and demonstrated practical utility suggest the method to be an accurate, efficient, and robust approach for the study of phase change in engineering systems.

97 MATHEMATICS AND COMPUTING↗

Probabilistic Voltage Sensitivity based Preemptive Voltage Monitoring in Unbalanced Distribution Networks

With increasing penetration of renewable energy and active consumers, control and management of power distribution networks has become challenging. Renewable energy sources can cause random voltage fluctuations as their output power depends on weather conditions. Conventional voltage control schemes such as tap changers and capacitor banks lack the foresight required to quickly alleviate voltage violations. Thus, there is an urgent need for effective approaches for predicting and mitigating voltage violations as a result of random fluctuations in power injections. This work proposes a novel voltage monitoring approach based on low-complexity, data-driven probabilistic voltage sensitivity analysis. The usefulness of this work is not only in predicting voltage violations in unbalanced distribution grids, but also in opening up the door for optimal voltage control. Using system data and forecasts, the proposed approach predicts the distribution of system node voltages which is then used to to identify nodes that may violate the nominal operational limits with high probability. The method is tested on the IEEE 37 node distribution system considering integrated distributed solar energy sources. The method is validated against the classic load flow based method and offers over 95% accuracy in predicting voltage violations.

Abujubbeh, Mohammad↗

An Integrated Method of ANFIS and Dempster-Shafer Theory for Fault Diagnosis of Power Transformer

Dissolved gas analysis (DGA) approach is extensively applied to detect incipient faults of power transformers. This paper presents a novel DGA method for power transformer incipient fault diagnosis based on integrated adaptive neuro fuzzy inference system (ANFIS) and Dempster-Shafer Theory (DST). Four out of seven common conventional methods which are studied and compared for better consistency and accuracy, are used to develop new ANFIS based fault diagnosis models. To promote fault diagnostic performance further and make fault decision process more reliable and reasonable, an improved DST is introduced to integrate outputs of each ANFIS based model, and to provide comprehensive and convincing fault diagnosis results. The fault diagnosis capability of the proposed method is validated by a reported fault dataset and 10-fold cross validation experiment. The performance of the proposed method is compared with conventional approaches and ANFIS based models which demonstrate that the proposed method is superior to other methods and is more effective and stable for power transformer fault diagnosis with high accuracy and consistency.

adaptive nuero fuzzy inference system↗

Post-Disturbance Dynamic Distribution System Restoration with DGs and Mobile Resources

Distributed generations (DGs) can act as emergency power supplies when distribution systems suffer from outages. However, the generation capabilities of DGs are generally limited by a number of factors including weather conditions, fuel limitations, etc. In this context, mobile resources that are able to reallocate resources to desired locations are regarded as important complements to conventional fixed DGs in assisting distribution system restoration. In this paper, a distribution system restoration model with DGs and mobile resources is proposed. Firstly, the dispatch and allocation of mobile resources are modeled with respect to the characteristics of the traffic network. Then the developed mobile resource models are integrated into the distribution system restoration model to co-optimize the scheduling of DGs and mobile resources. Uncertainty factors are managed by a model predictive control approach so that system operators can dynamically adjust the restoration strategy with the up-to-date information. The effectiveness of the proposed method is validated through an IEEE 13-bus test system.

distributed generations (DGs)↗

Dwarf spheroidal J-factor likelihoods for generalized NFW profiles

ABSTRACT Indirect detection strategies of particle dark matter (DM) in Dwarf spheroidal satellite galaxies (dSphs) typically entail searching for annihilation signals above the astrophysical background. To robustly compare model predictions with the observed fluxes of product particles, most analyses of astrophysical data – which are generally frequentist – rely on estimating the abundance of DM by calculating the so-called J factor. This quantity is usually inferred from the kinematic properties of the stellar population of a dSph using the Jeans equation, commonly by means of Bayesian techniques that entail the presence (and additional systematic uncertainty) of prior choice. Here, extending earlier work, we develop a scheme to derive the profile likelihood for J factors of dwarf spheroidals for models with five or more free parameters. We validate our method on a publicly available simulation suite, released by the Gaia Challenge, finding satisfactory statistical properties for bias and probability coverage. We present the profile likelihood function and maximum likelihood estimates for the J-factor of 10 dSphs. As an illustration, we apply these profile likelihoods to recently published analyses of γ-ray data with the Fermi Large Area Telescope to derive new, consistent upper limits on the DM annihilation cross-section. We do this for a subset of systems, generally referred to as classical dwarfs. The implications of these findings for DM searches are discussed, together with future improvements and extensions of this technique.

79 ASTRONOMY AND ASTROPHYSICS↗

A Moving Embedded Boundary Approach for the Compressible Navier-Stokes Equations in a Block-Structured Adaptive Refinement Framework

A computational technique has been developed to perform compressible flow simulations involving moving boundaries using an embedded boundary approach within the block-structured adaptive mesh refinement (SAMR) framework of AMReX [1], [91], [92]. We leverage the SAMR capability to obtain quantitatively accurate results whilst using robust, second-order finite volume schemes. A conservative, unsplit, cut-cell approach is utilized and a ghost-cell approach is developed for computing the flux on the moving, embedded boundary faces. A third-order least-squares formulation has been developed to compute the wall velocity gradients, and was found to significantly improve the performance of the solver in terms of the quantitative comparison of surface quantities such as the skin friction coefficient. Various test cases are performed to validate the method, and compared with analytical, experimental, and other numerical results in literature. Inviscid and viscous test cases are performed that span a wide regime of flow speeds - acoustic (harmonically pulsating sphere), smooth flows (expansion fan created by a receding piston) and flows with shocks (shock-cylinder interaction, shock-wedge interaction, pitching NACA 0012 airfoil and shock-cone interaction). A closed system with moving boundaries - an oscillating piston in a cylinder, showed that the percentage error in mass within the system decreases with refinement, demonstrating that the numerical scheme is conservative with grid refinement, but is not discretely conservative. Viscous test cases involve that of a horizontally moving cylinder at Re = 40, an inline oscillating cylinder at Re = 100, and a transversely oscillating cylinder at Re = 185. The judicious use of adaptive mesh refinement with appropriate refinement criteria to capture the regions of interest leads to well-resolved flow features, and good quantitative comparison is observed with the results available in literature.

adaptive refinement↗