At least 145 records · Page 8

Gateway Integrated ECLSS Model Analysis of Intermodule Ventilation Failures

The Gateway Integrated ECLSS Model (GIEM) is a set of two independent models, made in Aspen Custom Modeler (ACM) and Thermal Desktop (TD), of the Gateway stack and each modules' associated environment control and life support system (ECLSS). The GIEM utilizes the 41-Node Metabolic Man (METMAN) to simulate crew inside the Gateway consuming O2 and producing CO2, H2O, and heat for the ECLSS to remove. The modules and visiting vehicles all have different levels of ECLSS capabilities and may rely on other modules and Intermodular Ventilation (IMV), which is used to exchange gas between the modules, to ensure the entire Gateway environment is controlled. If IMV were to fail or be turned off, some vehicles may have limited access to necessary ECLSS functions. This analysis focuses on evaluating O2, CO2, and H2O levels when crew are in vehicles without their own life support and IMV has failed to evaluate how long before the atmosphere is unsafe for the crew. This analysis uses the integrated nature of the GIEM to look at time to effect for O2 depletion and CO2 and H2O buildup when crew are working in vehicles that have been cut off from the ECLSS-active portion of the stack. This information is used to inform for how long crew can safely continue working in the ECLSS-inactive vehicles before experiencing a requirement violation or physical limitation and can be referenced when developing maintenance and emergency response concept of operations (ConOps).

Lawrence Barrett↗

Evaluation of the Accumulation of Foreign Object Debris in the International Space Station Ventilation Systems and Resulting Impacts to Systems

A challenge for the International Space Station (ISS) is accumulation of foreign object debris (FOD) in the ventilation systems and the impacts to crew, equipment, and experiments. One function of the temperature and humidity control system is to capture FOD with various methods of filtration to minimize these impacts. ISS filtration has been augmented by charcoal and High Efficiency Particulate Air (HEPA) filters and screens. A qualitative comparison of the quantity of FOD found since 2012 study and the current levels are evaluated. Impacts due to FOD are reduced air circulation, increased crew time for cleaning, reduction of equipment life, and component damage; examples are provided. Recommendations for further improvements to reduce the accumulation of FOD on ISS are provided.

ISS↗

Spacesuit Sizing by Multivariate Simulation: Case Study for Liquid Cooling and Ventilation Garment

A technique was developed to assess the fit of spacesuit garment liquid cooling and ventilation garment (LCVG). A fit scoring scheme was built from the spacesuit sizing requirements and guidelines, and the accommodated proportion of the wearer population was estimated from statistically synthesized pseudo population data. The method evaluated different scenarios of LCVG sizing systems including 1) baseline 7-size system, 2) 7-sizes with target body dimensions iteratively adjusted for maximum fit, and 3) 9-sizes with iterative adjustments. Overall, the baseline sizing system showed 81% accommodation rate, while the hypothetical new systems in-tegrating iterative adjustments for 7- and 9-sizes predictively indicated that accommodation could improve up to 92 and 97%. The proposed method provided a structured metric to quantify fit performance of a garment sizing system, which can be further applied to different spacesuit component, PPE and garment designs.

Han Kim↗

Changes in Arabidopsis leaf ultrastructure, chlorophyll and carbohydrate content during spaceflight depend on ventilation

Leaf structure and function under spaceflight conditions have received little study despite their important implications for biological life support systems using plants. Previous reports described disruption of the membrane apparatus for photosynthesis and a general decrease in carbohydrate content in foliage. During a series of three short-duration experiments (Chromex-03, -04, -05) on the US space shuttle (STS-54, STS-51, STS-68), we examined Arabidopsis thaliana leaves. The plants were at the rosette stage at the time of loading onto the space shuttle, and received the same light, temperature, carbon dioxide and humidity regimes in the orbiter as in ground controls. The experiments differed according to the regime provided in the headspace around the plants: this was either sealed (on mission STS-54); sealed with high levels of carbon dioxide (on mission STS-51) or vented to the cabin air through a filtration system (on mission STS-68). Immediately post-flight, leaf materials were fixed for microscopy or frozen in liquid nitrogen for subsequent analyses of chlorophyll and foliar carbohydrates. At the ultrastructural level, no aberrations in membrane structure were observed in any of the experiments. When air-flow was provided, plastids developed large starch grains in both spaceflight and ground controls. In the experiments with sealed chambers, spaceflight plants differed from ground controls with regard to measured concentrations of carbohydrate and chlorophyll, but the addition of airflow eliminated these differences. The results point to the crucial importance of consideration of the foliage microenvironment when spaceflight effects on leaf structure and metabolism are studied.

STS-51 Shuttle Project↗

Acoustics and Performance of a Scaled Spacecraft Cabin Ventilation Fan

An axial fan was designed at NASA Glenn Research Center using tools developed for aircraft turbine engines. The fan unit design size, flow rate and pressure rise were chosen to be broadly in the range of the Orion cabin fan. A ground test prototype was built and tested, confirming design predictions. Pressure rise and flow rate measurements were conducted over a range of fan speeds while in-duct and radiated acoustic measurements were collected. Unsteady flow measurements were acquired between the rotor and stator. These methods are a hybrid of the techniques used for small fans and those used for aircraft engine component tests. A larger version of the fan was recently designed, based on the original fan, using aerodynamic scaling laws resulting in a design with approximately twice the flow rate and twice the pressure-rise compared to the original fan. The mechanical structure was optimized using generative design for low weight. The paper discusses this larger fan design including the scaling laws, the predicted performance and acoustics.

ventilation↗

Heating Ventilation Air-Conditioning (HVAC) System Analysis and Optimization for Revit with the OpenStudio Analytical Framework (CRADA Final Report)

This project proposes to integrate the NREL-developed OpenStudio (OS) and its accompanying Analytical Framework (OSAF) into Autodesk’s (ADSK’s) market leading suite of building information modeling (BIM) tools. As a result, BIM users will gain access to advanced (but user-friendly) building energy modeling (BEM), calibration, and design optimization capabilities. Following integration, the BIM software will automatically generate a consistent OS-based BEM model, allowing users to develop projects in an integrated manner, moving back and forth between architectural and engineering perspectives without redundancy or data loss, saving time and effort.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Glovebox CFD Analysis: Low-Flow, Laminar CFD Analysis of Glovebox Ventilation and Humidity Transport in Ansys Fluent 2025 R1

There are gloveboxes that frequently exceed the 30% relative humidity level required for operations. These exceedances result in alternative operations needing to be utilized. This report documents a computational fluid dynamics (CFD) analysis performed to characterize airflow and humidity transport within a representative glovebox under nominal, low-flow conditions. The analysis focuses on establishing the flow regime, identifying transport-limited regions, and evaluating the implications of laminar flow on humidity removal. A single-phase, laminar flow model with a species transport model was used to represent air and water vapor mixing. Results demonstrate that, at the nominal flow rates, airflow is laminar with weak mixing, which will result in long residence times, tens of minutes long or more, in low-velocity regions. These conclusions suggests that humidity reduction is transport-limited. This analysis provides qualitative insight into airflow structure and humidity transport trends. In addition to characterization of glovebox airflow and humidity transport, results are intended to inform experimental validation and future transient modeling efforts.

42 ENGINEERING↗

Reimagining Heating, Ventilation, and Air Conditioning for New Manufactured Homes

Manufactured homes represent one of the most affordable paths to home ownership for American households, but minimum-efficiency equipment and poor-quality home installation can lead to excess energy use and high operating costs. Slipstream, with partners from the Florida Solar Energy Center (FSEC), Northwest Energy Works, and Washington State University, identified and tested manufactured home HVAC innovations targeted for new construction offering the most promising mix of improved energy performance and likelihood of industry uptake.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparison of three liquid-ventilation cooling garments during treadmill exercise

A comparative study was made of the heat transfer performance and physiological effects of three different cooling garments used under sealed garments (simulating space suits) on five male subjects, during treadmill exercise. The mean exercise metabolic rate while walking at 0.9 m/s (2 mph) was 464 plus or minus 33 W. An equilibrium condition was never reached during the uncooled suited control runs and the subjects lost approximately two percent of body weight during the exercises. The mean weight loss with an Apollo-type garment was 0.35 plus or minus 0.10 kg, and 0.26 plus or minus 0.11 kg with the full-body cooling patch garment (garment 2). With the partial-coverage cooling patch (garment 3), the weight loss was 0.52 plus or minus 0.12 kg. The data showed an increase in the leg blood flow when the working muscles were not cooled by liquid flow (garment 3), and the arm blood flow remained unchanged with and without liquid cooling to the arms.

Webbon, B.↗