Search NASA⌕ Search

SEARCH · Search NASA

Results for “vibration reduction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Assessment Of The Stirling Power Option for Space Science Applications

Free-piston Stirling technology efforts in the past typically were intended to address power needs in the multi-kilowatt range. The Stirling power option was attractive primarily because of the high conversion efficiency and potential for long life. In recent years, several technology efforts have focused on the free-piston Stirling power d convertor for space power applications, however the more recent efforts are intended to provide power at levels far below one kilowatt. Through a variety of projects funded by both NASA and DOE, the free-piston Stirling convertor technology has successfully demonstrated high efficiency and long life. Other areas of concern, such as control of multi-convertor systems, and vibration reduction have also been addressed. Efforts are being initiated to address issues such as electro-magnetic interference (EMI), radiation tolerance of organic materials, and the ability to operate through launch loads and survive with integrity. The status of the technology in these areas will be briefly discussed in this paper.

Schreiber, Jeffrey G.↗

Design of the Active Elevon Rotor for Low Vibration

Helicopter fuselages vibrate more than desired, and traditional solutions have limited effectiveness and can impose an appreciable weight penalty. Alternative methods of combating high vibration, including Higher Harmonic Control (HHC) via harmonic swashplate motion and Individual Blade Control (IBC) via active pitch links, have been studied for several decades. HHC via an on-blade control surface was tested in 1977 on a full scale rotor using a secondary active swashplate and a mechanical control system. Recent smart material advances have prompted new research into the use of on-blade control concepts. Recent analytical studies have indicated that the use of on-blade control surfaces produces vibration reduction comparable to swashplate-based HHC but for less power. Furthermore, smart materials (such as piezoceramics) have been shown to provide sufficient control authority for preliminary rotor experiments. These experiments were initially performed at small scale for reduced tip speeds. More recent experiments have been conducted at or near full tip speeds, and a full-scale active rotor is under development by Boeing with Eurocopter et al. pursuing a similarly advanced full-scale implementation. The US Army Aeroflightdynamics Directorate has undertaken a new research program called the Active Elevon Rotor (AER) Focus Demo. This program includes the design, fabrication, and wind. tunnel testing of a four-bladed, 12.96 ft diameter rotor with one or two on-blade elevons per blade. The rotor, which will be Mach scaled, will use 2-5/rev elevon motion for closed-loop control and :will be tested in late 2001. The primary goal of the AER Focus Demo is the reduction of vibratory hub loads by 80% and the reduction of vibratory blade structural loads. A secondary goal is the reduction of rotor power. The third priority is the measurement and possible reduction of Blade Vortex Interaction (BVI) noise. The present study is focused on elevon effectiveness, that is, the elevon's ability to reduce all six components of the nonrotating 4/rev hub loads. Some design parameters have been kept fixed in this study, while others have been varied to determine their influence - on elevon effectiveness. The fixed parameters include all blade structural properties except for torsion stiffness; the varied parameters include torsion stiffness, elevon aerodynamic location, and the number and individual authority of elevon aerodynamic surfaces. This paper describes the preliminary design process being used for the AER, and describes and quantifies the emerging active rotor characteristics.

Fulton, Mark V.↗

Shake Test Results and Dynamic Calibration Efforts for the Large Rotor Test Apparatus

A shake test of the Large Rotor Test Apparatus (LRTA) was performed in an effort to enhance NASAscapability to measure dynamic hub loads for full-scale rotor tests. This paper documents the results of theshake test as well as efforts to calibrate the LRTA balance system to measure dynamic loads.Dynamic rotor loads are the primary source of vibration in helicopters and other rotorcraft, leading topassenger discomfort and damage due to fatigue of aircraft components. There are novel methods beingdeveloped to reduce rotor vibrations, but measuring the actual vibration reductions on full-scale rotorsremains a challenge. In order to measure rotor forces on the LRTA, a balance system in the non-rotatingframe is used. The forces at the balance can then be translated to the hub reference frame to measure therotor loads. Because the LRTA has its own dynamic response, the balance system must be calibrated toinclude the natural frequencies of the test rig.

Shake Test Results↗

Boeing Smart Rotor Full-scale Wind Tunnel Test Data Report

A full-scale helicopter smart material actuated rotor technology (SMART) rotor test was conducted in the USAF National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel at NASA Ames. The SMART rotor system is a five-bladed MD 902 bearingless rotor with active trailing-edge flaps. The flaps are actuated using piezoelectric actuators. Rotor performance, structural loads, and acoustic data were obtained over a wide range of rotor shaft angles of attack, thrust, and airspeeds. The primary test objective was to acquire unique validation data for the high-performance computing analyses developed under the Defense Advanced Research Project Agency (DARPA) Helicopter Quieting Program (HQP). Other research objectives included quantifying the ability of the on-blade flaps to achieve vibration reduction, rotor smoothing, and performance improvements. This data set of rotor performance and structural loads can be used for analytical and experimental comparison studies with other full-scale rotor systems and for analytical validation of computer simulation models. The purpose of this final data report is to document a comprehensive, highquality data set that includes only data points where the flap was actively controlled and each of the five flaps behaved in a similar manner.

Full-Scale Wind Tunnel↗

Characterization Testing of Lockheed Martin Standard Micro Pulse Tube Cryocooler

This paper describes the thermal performance, exported vibration, and magnetics testing and results of a Lockheed Martin standard micro pulse tube cryocooler. The thermal performance of the microcooler was measured in vacuum for heat reject temperatures between 150 and 300 K. The cooler was driven with Thales XPCDE4865 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 84 and 98 Hz. The optimal drive frequency was dependent on both input power and heat reject temperature. In addition, the exported forces and torques of the cooler were measured with the cooler driven by Thales CDE7232 drive electronics for input powers ranging from 4 to 20 W and drive frequency between 88 and 96 Hz. The exported forces were dependent on both input power and drive frequency. Moreover, the automatic vibration reduction function of the drive electronics was able to decrease the force in the compressor axis to below 10 mN 0-peak. Finally, the DC and AC magnetic fields around the cooler were measured at various locations.

McKinley, I. M.↗

Manufacturing and Scale-Up of Natural Fiber Composite eVTOL Propeller Skin and C-Channel

This report presents the manufacturing and scale-up of natural fiber composites for aerospace applications, conducted within NASA’s Convergent Aeronautics Solutions portfolio to advance aircraft capabilities and efficiency. The effort focused on the development and demonstration of two proof-of-concept articles, an Electric Vertical Take-off and Landing (eVTOL) propeller skin and a C-channel, produced through an iterative design and process optimization approach. Best practices and guidance on addressing key challenges with bio-based composite materials and manufacturing is provided. Ideally suited for non-load-bearing structural components, these emerging materials offer potential for weight reduction, vibration damping, noise mitigation, interference-free communication, and cost savings, without compromising the performance of safety-critical primary structures.

Natural fibers↗

Active Vibration Control for Helicopter Interior Noise Reduction Using Power Minimization

This report describes work performed by United Technologies Research Center (UTRC) for NASA Langley Research Center (LaRC) under Contract NNL11AA06C. The objective of this program is to develop technology to reduce helicopter interior noise resulting from multiple gear meshing frequencies. A novel active vibration control approach called Minimum Actuation Power (MAP) is developed. MAP is an optimal control strategy that minimizes the total input power into a structure by monitoring and varying the input power of controlling sources. MAP control was implemented without explicit knowledge of the phasing and magnitude of the excitation sources by driving the real part of the input power from the controlling sources to zero. It is shown that this occurs when the total mechanical input power from the excitation and controlling sources is a minimum. MAP theory is developed for multiple excitation sources with arbitrary relative phasing for single or multiple discrete frequencies and controlled by a single or multiple controlling sources. Simulations and experimental results demonstrate the feasibility of MAP for structural vibration reduction of a realistic rotorcraft interior structure. MAP control resulted in significant average global vibration reduction of a single frequency and multiple frequency excitations with one controlling actuator. Simulations also demonstrate the potential effectiveness of the observed vibration reductions on interior radiated noise.

Mendoza, J.↗

Finite-temperature many-body perturbation theory for anharmonic vibrations: Recursions, algebraic reduction, second-quantized reduction, diagrammatic rules, linked-diagram theorem, finite-temperature self-consistent field, and general-order algorithm

A unified theory is presented for finite-temperature many-body perturbation expansions of the anharmonic vibrational contributions to thermodynamic functions, i.e., the free energy, internal energy, and entropy. The theory is diagrammatically size-consistent at any order, as ensured by the linked-diagram theorem proved in this study, and, thus, applicable to molecular gases and solids on an equal footing. It is also a basis-set-free formalism, just like its underlying Bose–Einstein theory, capable of summing anharmonic effects over an infinite number of states analytically. It is formulated by the Rayleigh–Schrödinger-style recursions, generating sum-over-states formulas for the perturbation series, which unambiguously converges at the finite-temperature vibrational full-configuration-interaction limits. Two strategies are introduced to reduce these sum-over-states formulas into compact sum-over-modes analytical formulas. One is a purely algebraic method that factorizes each many-mode thermal average into a product of one-mode thermal averages, which are then evaluated by the thermal Born–Huang rules. Canonical forms of these rules are proposed, dramatically expediting the reduction process. The other is finite-temperature normal-ordered second quantization, which is fully developed in this study, including a proof of thermal Wick’s theorem and the derivation of a normal-ordered vibrational Hamiltonian at finite temperature. The latter naturally defines a finite-temperature extension of size-extensive vibrational self-consistent field theory. These reduced formulas can be represented graphically as Feynman diagrams with resolvent lines, which include anomalous and renormalization diagrams. Two order-by-order and one general-order algorithms of computing these perturbation corrections are implemented and applied up to the eighth order. The results show no signs of Kohn–Luttinger-type nonconvergence.

74 ATOMIC AND MOLECULAR PHYSICS↗

A Closed-Loop Optimal Neural-Network Controller to Optimize Rotorcraft Aeromechanical Behaviour: Theory and Methodology - Volume 1

Given the predicted growth in air transportation, the potential exists for significant market niches for rotary wing subsonic vehicles. Technological advances which optimise rotorcraft aeromechanical behaviour can contribute significantly to both their commercial and military development, acceptance, and sales. Examples of the optimisation of rotorcraft aeromechanical behaviour which are of interest include the minimisation of vibration and/or loads. The reduction of rotorcraft vibration and loads is an important means to extend the useful life of the vehicle and to improve its ride quality. Although vibration reduction can be accomplished by using passive dampers and/or tuned masses, active closed-loop control has the potential to reduce vibration and loads throughout a.wider flight regime whilst requiring less additional weight to the aircraft man that obtained by using passive methads. It is ernphasised that the analysis described herein is applicable to all those rotorcraft aeromechanical behaviour optimisation problems for which the relationship between the harmonic control vector and the measurement vector can be adequately described by a neural-network model.

Leyland, Jane Anne↗

Validated technology for the reduction of spacecraft vibrations - Controls-Structures Integration (CSI)

The NASA Langley Research Center has constructed several testbeds to assess the viability of flexible structure control. It is found, however, that simply adding sensors, actuators, and a control system to an existing structure (i.e. space platform) is not the preferred methodology for improving pointing performance. When the structure is designed without regard to pointing control, significant design freedom is lost. The preferred design procedure is to simultaneously design the structure and the control system, hence, the name Controls-Structures Integration. By designing the structure and control system simultaneously, much higher efficiency can be achieved. In this study, an 18 m long truss structure with several appendages was enhanced through integrated controls and structures design. The design was fabricated and tested for validation of the methodology. Test results collaborated predictions and showed a 60 percent reduction in control energy for the enhanced test article.

Newsom, Jerry R.↗

Exploring the influence of interfacial solvation on electrochemical CO 2 reduction using plasmon‐enhanced vibrational sum frequency generation spectroscopy

Although interfacial solvation plays an important role in determining carbon dioxide reduction (CO 2 R) kinetics, present understanding of the potential dependent properties of the electrochemical double layer under conditions relevant for CO 2 R remains limited. This article summarizes the development and recent applications of plasmon-enhanced vibrational sum frequency generation (VSFG) spectroscopy to study the effects of cation hydration and interfacial solvation on CO 2 R using CO as a vibrational Stark reporter. Results show that electrolyte cations retain their entire solvation shell upon adsorption to inactive sites, while active sites retain only a single water layer between the gold surface and the cation. Measurements also show that the total interfacial electric field can be separated into two contributions: one from the electrochemical double layer (Stern field) and another from the polar solvation environment (Onsager field). Surprisingly, correlating VSFG spectra with reaction kinetics reveals that it is the solvation-mediated Onsager field that governs the chemical reactivity at the electrode/electrolyte interface. Measuring the interfacial water spectra during electrocatalysis also provides evidence for the proton source during H2 evolution, which competes with CO 2 R in aqueous electrolyte. These findings highlight the importance of directly probing cation hydration and interfacial solvation, which mediates reaction kinetics at electrochemical interfaces.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of three controllers applied to helicopter vibration

A comparison was made of the applicability and suitability of the deterministic controller, the cautious controller, and the dual controller for the reduction of helicopter vibration by using higher harmonic blade pitch control. A randomly generated linear plant model was assumed and the performance index was defined to be a quadratic output metric of this linear plant. A computer code, designed to check out and evaluate these controllers, was implemented and used to accomplish this comparison. The effects of random measurement noise, the initial estimate of the plant matrix, and the plant matrix propagation rate were determined for each of the controllers. With few exceptions, the deterministic controller yielded the greatest vibration reduction (as characterized by the quadratic output metric) and operated with the greatest reliability. Theoretical limitations of these controllers were defined and appropriate candidate alternative methods, including one method particularly suitable to the cockpit, were identified.

Leyland, Jane A.↗

Interior Noise Reduction by Adaptive Feedback Vibration Control

The objective of this project is to investigate the possible use of adaptive digital filtering techniques in simultaneous, multiple-mode identification of the modal parameters of a vibrating structure in real-time. It is intended that the results obtained from this project will be used for state estimation needed in adaptive structural acoustics control. The work done in this project is basically an extension of the work on real-time single mode identification, which was performed successfully using a digital signal processor (DSP) at NASA, Langley. Initially, in this investigation the single mode identification work was duplicated on a different processor, namely the Texas Instruments TMS32OC40 DSP. The system identification results for the single mode case were very good. Then an algorithm for simultaneous two mode identification was developed and tested using analytical simulation. When it successfully performed the expected tasks, it was implemented in real-time on the DSP system to identify the first two modes of vibration of a cantilever aluminum beam. The results of the simultaneous two mode case were good but some problems were identified related to frequency warping and spurious mode identification. The frequency warping problem was found to be due to the bilinear transformation used in the algorithm to convert the system transfer function from the continuous-time domain to the discrete-time domain. An alternative approach was developed to rectify the problem. The spurious mode identification problem was found to be associated with high sampling rates. Noise in the signal is suspected to be the cause of this problem but further investigation will be needed to clarify the cause. For simultaneous identification of more than two modes, it was found that theoretically an adaptive digital filter can be designed to identify the required number of modes, but the algebra became very complex which made it impossible to implement in the DSP system used in this study. The on-line identification algorithm developed in this research will be useful in constructing a state estimator for feedback vibration control.

Lim, Tae W.↗

Six-Degree-of-Freedom Vibration Suppressor

New system, total-rotor-isolation system (TRIS) employs liquid-inertia vibration-eliminator (LIVE) units, designed to isolate all six degrees of freedom of aircraft-fuselage dynamic response from continuously changing airloads developed by rotor. Vibration suppressor uses liquid mercury to damp vibrations. Results of flight tests indicated at least 95-percent reduction in vibration levels from rotor hub to pilot's seat.

Halwes, Dennis R.↗

Analysis of a turbine rotor containing a transverse crack at Oak Creek Unit 17

Transient increases in one, two and three per revolution vibration characteristics of a low pressure steam turbine were observed during steam temperature reduction operations. Vibration and fracture mechanics analyses suggested the presence of a transverse shaft crack which was eventually identified by ultrasonic inspection and confirmed by destructive sectioning. Signature analyses of vibration data recorded over a two-year period prior to crack identification are correlated with fatigue crack growth, which occurred intermittently during transient temperature decreases. The apparent increased response of the rotor to vibration is due to asymmetric stiffness changes introduced by the growing transverse crack. The vibration response is predicted to increase with increasing crack depths in excess of 10% of the shaft diameter. Fracture mechanics analyses predict that fatigue crack growth occurred during periods of steam temperature decrease, when high surface tensile stresses are present. These same transient thermal stresses are shown to have retarded and prevented subsequent fatigue crack growth during steady operation.

Rogers, G. W.↗

Evaluation of passive and active vibration control mechanisms in a microgravity environment

The behavior of equipment and their light secondary attachments in large space structures under orbital excitation is studied. The equipment is modeled as a shear beam and its secondary attachment is treated as a single-degree-of-freedom lumped mass system. Peak responses of the equipment and its secondary system for a variety of vibration control mechanisms are evaluated. A novel active friction control mechanism, by varying the normal force, is suggested. The device uses a magnetic field control to minimize the stick condition, thereby reducing the overall structural response. The results show that the use of the passive vibration control devices could reduce the peak equipment responses to a certain extent. However, major reduction of vibration levels could be achieved only by the use of active devices. Using active control of the interface normal force, the peak responses of the equipment and its attachment are reduced by a factor of 10 over the fixed-base equipment response.

Ellison, J.↗