At least 145 records · Page 8

Cesium Removal from Tank Waste Simulants Using Crystalline Silicotitanate at 12% and 100% TSCR Bed Heights

The Direct Feed Low-Activity Waste flowsheet provides for the early production of immobilized low-activity waste (LAW) by feeding waste directly from Hanford tank farms to the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for vitrification. Prior to the transfer of feed to the WTP LAW Vitrification Facility, tank waste supernatant will be pretreated by the Tank Side Cesium Removal (TSCR) system to meet the WTP LAW waste acceptance criteria (<3.18E-5 Ci 137 Cs/mole of Na). This pretreatment will remove cesium from the waste stream using ion exchange (IX). The selected media for IX is crystalline silicotitanate (CST), product number UOP-IONSIV-R9140-B, manufactured by Honeywell UOP LLC (Des Plaines, IL). Testing was requested by Washington River Protection Solutions to better define IX processing using Low-Activity Waste Pretreatment System (LAWPS) prototypic IX unit operation process steps at full height and medium height. The information is intended to significantly contribute towards establishing accurate process flowsheets for the individual feed campaigns planned for the LAWPS. Column testing at both the medium (12% of the full bed height) and full height scales was conducted to evaluate process variables and scale up performance of Cs exchange onto the CST, Lot 8056202-999. Nominal process conditions used 5.6 M Na simulant processed at 1.8 bed volumes per hour (BV/h) at 20 °C. Process variables included 1) increased process temperature to 35 °C, 2) increased Na concentration to 6.0 M, 3) added organics to the 5.6 M Na simulant, and 4) flowrate changes. The medium scale tests used single columns containing 44 mL of <25 mesh CST in a 1.44 cm diameter column, 27 cm tall CST bed. The full height columns used lead/lag columns containing 1.15 L unsieved (as-received) CST in 2.54-cm-diameter columns, 226 cm tall CST beds. Two process flowrates were tested at the full height: 1.30 and 1.82 BV/h. IX testing with simulant solutions was conducted using TSCR prototypic IX unit operations: feed processing, feed displacement with 0.1 M NaOH, water rinse, and solution expulsion with compressed air.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Continuous Laboratory-Scale Melter Runs for System Evaluation

The Waste Treatment and Immobilization Plant (WTP) will process and stabilize waste that is stored in underground tanks on the Hanford Site. Currently, the first phase of the planned WTP startup and operation, called Direct Feed Low-Activity Waste (DFLAW), involves directly feeding only the liquid portion of the waste to electric melters in the WTP Low-Activity Waste (LAW) Vitrification Facility without full pretreatment. A second portion of the tank waste, called high-level waste (HLW), is set to contain most of the radioactivity inventory.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Enhanced Hanford Low-Activity Waste Glass Property Data Development: Phase 2

The U.S. Department of Energy’s (DOE) Office of River Protection (ORP) requested Pacific Northwest National Laboratory (PNNL) to support the River Protection Project vitrification in an effort to support operations upon completion of startup activities (DOE 2012). This work was performed under the PNNL project titled “ORP Glass Support Work.” One task of this project—Enhanced Hanford Waste Glass Models—is the subject of this report. A previous task focused on generating property-composition data and models for the Hanford site low-activity waste (LAW) glasses with lower waste loadings, which are relevant to the commissioning of the LAW vitrification facility. The current task has the long-term objective of expanding the Hanford site LAW glass database and property composition models for the balance of the Hanford site tank waste treatment and immobilization mission. During the balance of the mission, LAW glasses with higher waste loadings will be produced. This report presents the glass compositions and glass property data developed in Phase 2 of the enhanced Hanford LAW glass property data development effort. When this effort is complete, enhanced LAW glass property models will be developed. Section 1.1 summarizes the status of the LAW glass composition regions and waste loading constraints prior to the data development effort documented in this report. Section 1.2 summarizes the LAW Phase 2 glass composition region and test matrix. Section 1.3 documents the quality assurance program used in performing the work discussed in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compilation of Off-Gas Vapor and Liquid Phase Organic Information from Scale Melter Testing of LAW Simulants (VSL-17S4450-1, Rev A)

The objective of this statement of work (SOW) is to obtain available offgas data from scale melter testing of low-activity waste (LAW) simulants within the Vitreous State Laboratory’s possession. The data will be used to provide an estimate of the composition and concentration of organic constituents expected to be present in the liquid waste streams generated from offgas treatment at the LAW Vitrification facility during cold commissioning (prior to radioactive commissioning).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1% (w/w) total organic carbon as Na 3 -HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per-component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST-in-water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Gas Generation Testing of Crystalline Silicotitanate Ion Exchange Media

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford site. As planned, Hanford tank waste would be sent to the Tank Side Cesium Removal (TSCR) system for solids removal (by filtration) and cesium removal (by ion exchange) during the initial phase of the DFLAW process. The resultant treated waste would be delivered to the LAW Vitrification Facility at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) for immobilization. The ongoing technology maturation of TSCR system components is being conducted by Washington River Protection Solutions, LLC (WRPS). The ion exchange process in the TSCR system will use columns of crystalline silicotitanate (CST) to remove cesium from the LAW. This report describes gas generation testing of the crystalline silicotitanate ion exchange media that was conducted to strengthen the technical basis of the media for use in the TSCR system. Specifically, the described study will inform the safety basis of both the operation of the TSCR system and the interim storage condition of the TSCR ion exchange columns after loading. Previous data on gas generation of CST are limited to a handful of studies using CST or similar media under unrepresentative conditions and durations. The safety basis underlying operation and storage of the CST columns needs to consider the rate and extent of radiolytic flammable gas generation. No existing studies provide a comprehensive set of gas generation data for column operating and storage conditions representative of those expected for TSCR. To address the data gap, this study was conducted under the following conditions (each in duplicate): (1) CST in water at 25°C tested to 300 Mrad total dose, (2) wet CST (soaked in water, then free-drained) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (3) dry CST (air-dried, free-flowing material equilibrated to laboratory conditions) at 25°C tested to both 300 Mrad and 900 Mrad total dose, (4) CST in 5.6M Na simulant at 25°C tested to 300 Mrad total dose, and (5) CST in 5.6M Na simulant with 1%(w/w) total organic carbon as Na3-HEDTA at 25°C and 70°C tested to 300 Mrad total dose. For each of the listed conditions, the generation of the following gas species was measured: hydrogen, oxygen, nitrous oxide, and methane. The test data was used to determine the amount of gas generated (total and on a per component basis), gas generation rates normalized to the CST bed volume tested, and G-values for each gas species. The reported results illustrate that the CST in water condition bounds the gas generation rate (at 25°C) of all other conditions, but there is some variability in the hydrogen G-value, depending on the lot of CST tested and the amount of residual moisture present at the start of the test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Physical and Flow Properties of Glass-Forming Chemicals (V 2 O 5 , SnO, SnO 2 , Cr 2 O 3 , FeCr 2 O 4 , and ZrSiO 4 ) and Mixtures

For an efficient nuclear waste vitrification process at the Waste Treatment and Immobilization Plant (WTP) on the Hanford Site, proper selection and consistent supply of glass-forming chemicals (GFCs) are crucial. Thorough characterization of the GFCs is required to reduce risks in operation of the vitrification facility. Low-activity waste (LAW) will be blended with GFCs to form slurry feeds and then fed to melters and vitrified. To enhance properties of waste glasses, new chemicals are being introduced to the current GFC mixture. In this study, three new GFCs were evaluated for enhanced LAW glass formulations: chromium oxide (Cr 2 O 3 ), vanadium oxide (V 2 O 5 ), and stannic oxide (SnO 2 ). These three oxide components are included in enhanced waste glass formulations, and GFCs with the appropriate physical and flow properties are needed. As a starting point, single metal oxide GFCs, Cr 2 O 3 , V 2 O 5 , and SnO 2 , were sourced and tested. Then, alternative sources of Sn and Cr (SnO and FeCr 2 O 4 ) were tested along with an alternative zircon source (ZrSiO 4 ). This report documents the work performed to collect physical and flow property data on these new GFCs and melter feed slurries generated using these GFCs and simulated low-activity wastes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Full Scale HEPA Filter Encapsulation in Ultra-High-Performance Grout - Proof of Concept

The Hanford Tank Waste Treatment and Immobilization Plant (WTP) currently being constructed to treat radioactive waste, includes vitrification facilities for both the high-level waste (HLW) and low activity waste (LAW) fractions. Operation of the WTP will produce contaminated high-efficiency particulate air filters (HEPA), as part of the solid secondary waste (SSW) stream. The HEPA filters receive off-gas from the vessel vent header and primary off-gas treatment system in LAW Facility and remove particulate contaminants including 99 Tc and 129 I salts. The current disposal method for HEPA filters is encapsulation in metal containers using cementitious material (CM) and disposal in the Integrated Disposal Facility (IDF). Results from the 2017 IDF Performance Assessment (PA) WRPS (2018) demonstrated that while compliance is maintained for the 1000 year compliance period mandated by DOE O 435.1 and its accompanying manual, release of constituents from the HEPA filters result in exceedance of the performance objective imposed as the groundwater regulatory limit at later times. For example, at about 1500 years post-closure, solid secondary waste (SSW), including HEPA filters is predicted to become a dominant contributor to 99 Tc release and over the 10,000-year sensitivity analysis period, SSW is the dominant contributor of 129 I release to the groundwater. The estimated release could potentially be reduced if the HEPA filters are not compacted and waste containers could be distributed throughout a large space, thereby diluting the contaminant release. Additionally, a better cementitious material could be used to encapsulate the HEPA filters. One alternative method for disposal of contaminated HEPA filters is encapsulation of the filters in ultra high-performance grout (UHPG). UHPG is a variation of ultra-high-performance concrete (UHPC) is commonly used in the prestressed concrete industry for large structural members. Recent studies of UHPG show it has excellent properties for containing radionuclides such as 99 Tc and 129 I Nichols and Kaplan (2021). This report presents the results of the first attempt to encapsulate a clean, full-size HEPA filter in UHPG and evaluate the effectiveness of the immobilization process and final waste form. A full-scale proof-of-concept simulated waste form was prepared by encapsulating a HEPA filter in a 110-gallon stainless steel (SS) drum using UHPG. A change from Type I/II PC to Type 1L PLC was made after American Rock Products informed the team that they would no longer be using Type I/II by the end of 2024 and the northwest was phasing out Type I/II PC overall. Type I/II PC used in previous studies of UHPG for encapsulation (Nichols and Kaplan 2021). After the UHPG was cured both the scaled mockup and the full-scale simulated waste forms were sectioned for visual examination. UHPG completely encapsulated the filters and bonded to the external surfaces of materials comprising the filters. No cracks were observed in the sectioned waste forms.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of Property Composition Models For RPP-WTP LAW Glasses (Final Report)

This report describes the development of property-composition models for low-activity waste (LAW) glasses for the River Protection Project Waste Treatment Plant (RPP-WTP) at the Hanford site. The RPP-WTP will separate Hanford tank wastes into LAW and high-level waste (HLW) streams and each stream will be vitrified separately. The development of LAW and HLW glass formulations for the RPP-WTP has been reported previously and is an ongoing activity. Acceptable formulations must meet a variety of processability, product quality, and waste loading requirements that are dictated either by the RPP-WTP contract or by the characteristics of the particular treatment processes that have been selected. These requirements amount to constraints on the acceptable ranges of certain glass properties. These properties are determined first and foremost by the composition of the glass or glass melt. Thus, while there is no direct way of controlling the glass properties of interest during production, there are simple and extremely effective methods of achieving the same result by instead controlling the glass composition. This basic principle is no different from that used to produce enormous volumes of commercial glass to meet exacting product specifications. An essential difference in waste vitrification, however, is that one of the raw materials (the waste itself) can be subject to considerable compositional uncertainty and variability. Thus, waste vitrification facilities and associated process control systems (of which, the operating envelope in glass formulation space is a key part) must, of course, be designed to be robust with respect to such variations. The determination of quantitative relationships between the glass properties that must be controlled and the glass composition can play an important role in the development of such facilities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY24 Development of Improved Grout Waste Forms for Alternative Low Activity Waste Treatment

Since the WTP Low Activity Waste (LAW) Vitrification Facility was not designed to process the entire inventory of Hanford LAW, up to half of the retrieved Hanford LAW will require supplemental immobilization. Immobilizing LAW in a cementitious waste form known as Cast Stone has been investigated as a possible candidate supplemental immobilization technology. In FY21, Washington River Protection Solutions, LLC (WRPS) tasked Atkins and the Vitreous State Laboratory (VSL) of The Catholic University of America (CUA) to perform testing to evaluate methods for reducing the release of COCs, particularly nitrate, 99Tc, and 129I, from cementitious waste forms made from aqueous LAW derived from Hanford Tank Waste. FY22 work built on the FY21 results and further developed formulations while targeting higher waste loadings. The objective of this work was to perform laboratory-scale testing to further refine the most promising formulation(s) that were identified in the FY23 work. The goal of the refinement was to further reduce the release rates for 99Tc, Cr, 129I, and nitrate while maintaining workability of the fresh grout, and to increase waste loading.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Affinity of LDR Organics to Cementitious Materials and Activated Carbon

The Hanford site stores approximately 56 million gallons of radioactive and hazardous waste in underground storage tanks. The current low-activity waste (LAW) vitrification facility does not have the capacity to immobilize all of the LAW. Therefore, cementitious waste forms are being evaluated as a cost-effective supplemental waste treatment, focusing on the solidification/immobilization of Land Disposal Restricted (LDR) organics, which is currently not recognized by the Environmental Protection Agency (EPA) as a standard treatment method (40 CFR 268.42). Previous efforts by the EPA and waste management agencies have highlighted the potential for cementitious materials to retain certain organic species through physical (encapsulation) and chemical (sorption) interactions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effects of Beta Irradiation on the Performance of ATR Fiber Probes

The use of real-time inline monitoring to track the chemical composition of slurries is recognized as a promising method to reduce the processing time of Hanford tank waste. The conversion of waste into glass suitable for long-term storage requires adherence to waste acceptance criteria and process control limits that respectively ensure safe operation of the vitrification facility and suitable glass quality. Real-time measurements of blended waste materials can ensure that the various criteria are met or can be addressed in a timely manner.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford WTP LAW Melter Startup and Tuning Feed Material Development - 17065

The U.S. Department of Energy's (DOE) Hanford Site in southeast Washington state is home to 56 million gallons of chemical and radioactive waste stored in underground tanks, the result of more than four decades of plutonium production. To address this challenge, the U.S. Department of Energy contracted Bechtel National, Inc., to design and build the world's largest radioactive waste treatment plant. The Hanford Tank Waste Treatment and Immobilization Plant (WTP) will use vitrification to immobilize most of Hanford's waste. Vitrification involves blending the waste with glass-forming materials, and heating it to high temperature to form molten glass, then pouring it into stainless steel containers. In this glass form, its radioactivity will decay over hundreds to thousands of years. In advance of full operation of WTP, a sequential process of commissioning will be undertaken to ensure the plant operates safely and within design requirements. The first phase of WTP operations will focus on the Low-Activity Waste (LAW) Vitrification Facility and its supporting facilities and systems. Commissioning of the LAW Facility will employ a progressive approach to address the complexity of system operation and introduction of hazards. This approach starts with introduction of low hazard and simple testing configurations, and incrementally increasing the complexity and hazardous makeup of testing feed materials, culminating in fully integrated treatment of radioactive tank waste during hot commissioning. Testing with simulants that are chemically similar to radioactive tank waste introduces significant chemical hazards into treatment systems in the form of nitrogen oxides (NOx) and anhydrous ammonia. A method of testing to allow tuning and demonstration of equipment and to develop operator proficiency prior to introducing these chemical hazards was deemed necessary. To that end, the development and testing of a new 'tuning feed' material is in progress. The tuning feed is important because its use will enable the first-time integration of all LAW Facility process systems. The tuning feed must include key physical and chemical characteristics that correspond to the commissioning simulant and low activity tank waste, without the inherently hazardous materials or toxic off-gas constituents that result from tank waste treatment. Tuning feed is being developed to provide representative melter feed rheology, glass chemistry, cold cap formation, and off-gas generation rate in order to predict system response to actual tank waste to the extent practical. The tuning feed must also be compatible with process equipment and other process streams that will be encountered during the cold commissioning testing program. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Integrated Waste Feed Delivery Plan for the Direct Feed Low-Activity Waste Mission - 17160

In order to begin tank waste treatment and reduce the risk to the liquid waste cleanup mission, a plan to directly feed the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Low-Activity Waste (LAW) Vitrification Facility before other WTP facilities has been implemented. Implementation requires another facility, the Low-Activity Waste Pretreatment System (LAWPS), to generate LAW from tank waste supernatant, along with upgrades to the existing tank farm facilities to provide waste feed and receive process returns. The Integrated Waste Feed Delivery Plan (IWFDP) presents the strategy for reliably delivering compliant waste feed to the LAWPS and subsequently WTP to safely and efficiently accomplish the direct feed LAW (DFLAW) mission. Modifications to existing systems and installation of new systems will be coordinated to meet WTP startup, commissioning, and processing needs. The IWFDP presents the process approach, feed campaign plans, and a list of infrastructure projects required to upgrade the DST system in order to support DFLAW start-up and operations. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling and Analysis of Coupled Flow Through Packed Beds as a Diagnostic Tool for Packed Bed Reactor Health - 17172

The US Department of Energy, Office of River Protection, is building the Waste Treatment and Immobilization Plant (WTP) in Richland, Washington, to immobilize the hundreds of millions of liters of radioactive waste stored at the Hanford Site in Washington state. The offgas generated during vitrification of these wastes requires treatment to remove and/or destroy chemical and radioactive hazardous components before release to the atmosphere. In particular, volatile and semi-volatile hydrocarbon components are to be catalytically oxidized to carbon dioxide and water, whereas nitrogen oxides (NOx) are to be catalytically reduced to nitrogen and water. These tasks are accomplished in a series of packed bed reactors. Achieving the requisite Destruction/Removal Efficiency (DRE) for each of the tracked components is highly dependent on the flow characteristics of the offgas through the packed beds. The flow kinetics may be monitored and characterized during the initial warm-up of the system. The gases, initially at 76 deg. C (169 deg. F), (a) flow through one side of a countercurrent heat exchanger to recover heat from the exiting gases (which have already passed through the catalytic beds), (b) are then further heated electrically to approximately 400 deg. C (750 deg. F; the preferred operating temperature of the Thermo Catalytic Oxidizer (TCO)), (c) pass through the TCO where the reduced components of the offgas are oxidized over a supported Pt catalyst bed, (d) are partially cooled to approximately 315 deg. C (600 deg. F) by addition of approximately 25% (by weight) diluted ammonia/air mixture, (e) pass through the Selective Catalytic Reducer (SCR) where the NOx components are converted to N{sub 2} and H{sub 2}O over a supported V2O{sub 5}/TiO{sub 2} catalyst bed, and (f) exit through the hot side of the countercurrent heat exchanger. The electrical heater is not powerful enough to raise the temperature of the offgas to the desired 400 deg. C without the contribution of the heat recovered in the heat exchanger. Moreover, the thermal mass of the beds and housings of the TCO and SCR require a significant input of thermal energy to reach the desired operating temperatures; the better part of a day is required to bring the unit from ambient temperatures to operating temperatures. Therefore, the temperature of the stream during the initial warm-up of the system at each point in the system is dependent upon the thermal mass, flow dispersion, and permeability of the components, quantified as characteristic/representative volumes and residence times. By monitoring the temperature of the offgas as it enters and exits each portion of the system during this warm-up period one may model the system as a series of small Continuously Stirred Tank Reactors (CSTR)s (referred to as 'CSTRlets') to explain the flow kinetics through the catalyst beds. These component CSTRlets are adjustable in size and number, that one may model the flow profile of the gases through the catalyst beds. For example, a single large CSTR will present an effluent temperature profile with a simple exponential decay shape. Concatenating more CSTRlets generate more complex sigmoidal responses. Concatenating one CSTRlet significantly larger than the others in the train also alters the shape of the effluent temperature profile, in a fashion not replicable by a train of equal-sized CSTRlets. The ultimate goal is to accurately emulate the entire system as a representative CSTRlet train. Once accomplished, this characterization may be used in subsequent warm-ups (following shutdown for catalyst maintenance, for example) or by an intentional step change in inlet offgas temperature to detect/diagnose anomalies in flow through the beds (e.g., channeling or partial blockage.) This work presents development of this model through analytical, calculational, and empirical means. - The analytic model is accomplished by Laplace transform analysis of each component to recover component process transfer functions. - The calculational portion is performed via brute force finite element calculation. - Fitting empirical data from the warm-up of the TCO skid allows one to select the hypothetical CSTRlet trains which best fit the TCO and SCR beds for the analytical and finite element calculations. The first portion of this paper presents the development of the analytical (Laplace space) model of the coupled system. Estimated values for the initial temperature, mass, specific heat, electrical heat, and relative quantities of the offgas, catalyst beds, stainless steel housings, and ammonia dilution stream are used to generate expected temperature profiles at several selected junctures of the system. The number and size of the component hypothetical CSTRlets are calculated from the analytical model and are used to predict temperature profiles at the exit of the system and at intermediate junctions between system components (where thermocouples are present in the actual unit.) The finite element calculations employ a series of CSTRlet volumes to produce a similar suite of temperature profiles, for comparison with the analytical model results. Finally, empirical data from the Factory Acceptance Test system warm-up are used to select and compare the results from each modeling strategy to select the CSTRlet train(s) which best model the behavior of the actual system. This work presents a novel method of system component characterization, of value to the WTP plant and similar vitrification facilities as well as chemical process industries unrelated to waste management. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Prediction of Gibbsite Precipitation for LAWPS and TSCR Processes at Hanford (U)

Determining the risk of precipitation of feed streams that could potentially lead to plugging ion exchange columns resulting in potential safety concerns and inefficient operation. Characterizing the feed to the filter at the Hanford site and compare it to the feed stream at SRS in ARP-MCU. Different precipitation distribution was observed for Hanford and SRS sites. Gibbsite precipitation is strongly affected by hydroxide concentration and temperature. High degrees of uncertainty of prediction of the exact amount of precipitate due to the extreme sensitivity of the waste solution to hydroxide fluctuations. Overall TSCR system consists of transferring supernate into an existing tank farm tank. Upon sampling and feed qualification, the supernate is sent into a dead-end filter to remove entrained solids, then is passed through an ion exchange column. The treated supernate will then be sent into another tank farm tank which will be used as the feed to the LAW vitrification facility. 250 + projected feed batches provided by Hanford: Reduced down to 65 batches; Projecting the feed vector from 2021-2054. Differences in Hanford and Savannah River waste feed stream compositions leading to dissimilar ionic interactions thus different precipitation distributions. Gibbsite: Dominating precipitate in Hanford waste (89 %). Sodium Oxalate: Predominant precipitate in SRS Waste (84 %). Based on the results, gibbsite precipitation is inversely affected by hydroxide concentration and temperature. Risk of precipitation is highly sensitive to hydroxide concentration and can vary significantly with slight fluctuations. All 65 batches showed distinct results with the range of [0.14, 1.25] Vol % and [0.28, 1.92] Mass % PPT.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Valent Iron for Reductive Removal of Technetium-99 from Aqueous Sulfate Solutions - 20347

This research investigates the reductive removal of technetium-99 ({sup 99}Tc) by zero valent iron (ZVI) from low activity waste (LAW) off-gas condensate simulant as a secondary treatment after recovery from vitrification planned at the Hanford Tank Waste Treatment and Immobilization Plant (WTP). Due to its high volatility, only a fraction of Tc{sup (VII)} will be incorporated into glass waste forms. Volatilized Tc will be captured by an off-gas treatment system with current plans to recycle off-gas condensate back to the vitrification facility. The scheme with off-gas recycling will increase Tc loading in the glass waste, but will also increase the concentrations of sulfate, halides, and other problematic constituents impeding overall LAW processing and increasing volume of the glass product. This study focuses on Tc{sup (VII)} removal by ZVI as a feasible pathway to minimize off-gas condensate recycling, which may result in a reduction in the volumes of LAW waste to be immobilized and subsequent cost savings. ZVI is an established treatment agent for redox-active contaminants such as trichloroethylene, nitrate, arsenic, chromium, phenol, and others. It is a commercially available and cost-effective material. Our previous experiments showed that ZVI is very efficient for the reductive removal of {sup 99}Tc. In this work we studied ZVI oxidation under aerobic conditions at pH 7 with 0.1 M Na{sub 2}SO{sub 4} solution (ionic strength, IS, 0.3 M) in the presence and absence of {sup 99}Tc. The concentration of {sup 99}Tc and the changes in pH, dissolved oxygen (DO), and oxidation-reduction potential (ORP) of the simulated solutions were monitored over 8 days. The formation of iron oxide phases was probed by X-ray diffraction (XRD). Obtained results suggest that ZVI contact time with {sup 99}Tc containing solutions for 6 hours resulted in nearly complete removal of {sup 99}Tc from the aqueous phase. XRD analysis showed that the oxidation of ZVI is rapid with formation of magnetite (Fe{sub 3}O{sub 4}) with minor percentage of goethite and maghemite. This work is a part of a larger set of studies investigating the feasibility of {sup 99}Tc reductive removal from the LAW off-gas condensate. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Using Best Basis Inventory Data to Direct Strategies for Real Time Monitoring of Hanford High Level Waste – 26226

The potential to accelerate the processing of low- and high-level tank waste by applying real-time monitoring (RTM) of chemical and physical properties has prompted research into the suitability of multiple analytical methods for that purpose. The broad variety of waste stream properties and the large number of analytes of interest (as evidenced by Waste Acceptance Criteria (WAC) and Process Control Limit (PCL) lists) lead to an overwhelming set of possible analytical scenarios. This report describes the use of Best Basis Inventory (BBI) data to find the most relevant analytical targets for the specific case of monitoring the blending of High Level Waste from multiple tanks prior to introduction into a vitrification facility. Campaigns for blending this waste to minimize the risk of exceeding WACs and PCLs have been proposed. However, the predicted compositions of the blended materials do not incorporate any uncertainties that may be associated with the representativeness of the waste layer samples or the laboratory analyses that generated the BBI data. Also, they do not include any uncertainty associated with the precision of collecting highly specific fractions of the layers during a blending campaign or any inhomogeneities that may exist in those layers. Monte Carlo methods are used to apply uncertainties to the compositions of the individual layers specified in the campaign recipes. The resulting variations in the compositions of the blended materials allow estimation of the risks of exceeding WACs and PCLs for each campaign. A critical subset of WACs/PCLs – NOx, NaK, AlFeZr, and S – are especially at risk of being exceeded in multiple campaigns. These analytes should be the focus of instrument development. We also have extracted the expected solid/supernate distribution for these analytes, which establishes important performance criteria for individual analytical methods. The BBI data also permits an understanding of the different chemical forms in which the analytes appear. Thus, the need to establish instrumental sensitivity to these forms can be gainfully addressed. Although concentrating on one specific application – the blending of tank waste - this approach should be generalizable for the analysis of other possible RTM applications for waste processing.

Lascola, Robert [Savannah River National Laborator↗