At least 145 records · Page 8

Utilizing Oxygen Redox in Layered Cathode Materials from Multiscale Perspective

We report in high-capacity layered oxide cathode materials, utilization of lattice oxygen as a redox center is considered to be one of the most promising approaches to overcome the capacity limitation set by conventional transition metal redox centers. However, rapid material degradation is often associated with oxygen oxidation, leading to formidable challenges in utilizing oxygen redox. Further mechanistic understanding of the oxygen activities thus becomes critical to better control oxygen redox reactions. This review summarizes recent advances for investigating oxygen redox reactions in cathode materials from a multiscale perspective, i.e., from the atomistic level to the microstructure regime. First the mechanistic aspects of oxygen redox and the consequences of this reaction on various electrode degradation pathways during battery operation (e.g., oxygen loss, transition metal migration, irreversible phase transition), relating structural changes at the crystallographic scale to those at the macro scale, are discussed. Then recent developments based on atomic and microstructure modifications that are promising for improving the reversibility of oxygen redox reaction or mitigating the harmful processes arising from oxidation of the oxygen centers under high operating voltage are recounted. The analysis is concluded with a commentary on further research directions toward optimizing the oxygen activity for high-capacity charge storage.

25 ENERGY STORAGE↗

Half-cell electrode assessments of a crossover-tolerant direct methanol fuel cell with a platinum group metal-free cathode

In this work, a platinum group metal- free (PGM-free) Fe-N-C oxygen reduction reaction (ORR) catalyst derived from metal organic framework precursors (Fe-MOF) is evaluated at the cathode side of a direct methanol fuel cell (DMFC). A wide range of methanol concentrations were used, and the performance of the DMFC using air was evaluated and compared to a commercial Pt/C cathode. We conducted our tests with a custom, integrated H 2 reference electrode that separately provided the anode and cathode overpotentials. This allowed us to perform a Tafel analysis on both electrodes and understand the dominant polarizations involved at the PGM-free cathode and the PtRu/C anode. Overall, we achieved a high cell performance using a Fe-N-C based catalyst under liquid methanol and air operation with a peak power density of 111 mW/cm 2 , where the cathode presented a markedly larger contribution to the voltage loss versus the anode. Additionally, we used nanoscale X-ray computed tomography (nano-CT) to image the Fe-N-C cathode and investigate the ionomer and pore size distributions allowing us to identify areas of improvement for catalyst layer fabrication.

30 DIRECT ENERGY CONVERSION↗

Analysis of anion exchange membrane water electrolyzer performance and its evolution over time

Understanding water, evolved gas, and ionic transport in membrane-electrode-assemblies (MEAs) is essential for the development of high performance and durable anion exchange membrane water electrolyzers (AEMWEs). This study evaluates the MEA conditioning process, operating conditions, and short-term stability in a 1 M potassium hydroxide (KOH) electrolyte, focusing on the underlying transport phenomena. We observe a significant initial voltage loss in continuous cell operation, which could be associated with gas bubble accumulation, transport layer or flow field passivation, and changes in the catalyst oxidation state. Further, we investigate the effects of materials and operational configurations, including the membrane type and thickness, and the electrolyte flow rate, including KOH being fed to both electrodes as well as to the anode only. Furthermore, the effect of membrane drying temperature on ex situ as well as in situ electrochemical performance is evaluated. Finally, we discuss 700 h of AEMWE operation at 1 A/cm 2 , highlighting the underlying degradation phenomena.

25 ENERGY STORAGE↗

Predicting Trends in VOC Through Rapid, Multimodal Characterization of State-of-the-Art p-i-n Perovskite Devices

Perovskite photovoltaic technologies are approaching commercial deployment, yet single junction and tandem architectures both still have significant room to improve power conversion efficiency and stability. The ability to perform rapid screening of material quality after altering processing conditions is critical to accelerating the optimization and commercialization of perovskite-based technologies. Currently, researchers utilize a wide range of stand-alone metrology tools to isolate sources of power loss throughout a device stack, which can be slow and labor intensive. Here, we demonstrate the use of a multimodal metrology approach to rapidly determine the maximum achievable and predicted open circuit voltages of >100 perovskite devices during fabrication. Acquisition of these different data is facilitated by combining them into a single integrated measurement platform. We show that these data and automated analysis can be used to rapidly understand and ultimately predict quantitative trends in open circuit voltages of state-of-the-art device architectures. The data and automated analysis workflow presented provides a reliable approach to quickly identify absorber and charge transport layer combinations that can lead to improved open circuit voltages.

14 SOLAR ENERGY↗

Limiting mechanisms in large-grain polycrystalline silicon Spatial homogeneity

An experiment to investigate the spatial homogeneity of large-grain polycrystalline silicon shows a number of performance-loss mechanisms. Arrays of up to 400 small (about 0.2 sq cm in area) photodiodes were fabricated on a selection of 10 cm x 10 cm polycrystalline silicon wafers. Measurements of the illuminated current-voltage (J-V) characteristics were used to generate maps of Voc, Jsc, and FF as a function of position; and dark J-V and LBIC analysis were used to determine the cause of low performance in areas with significantly degraded J-V characteristics. In addition to the presence of inclusions, which act as resistive shunts, the performance of many of the cells is limited by quasineutral recombination current, which may vary by up to an order of magnitude across a wafer. The increase is the result of either electrically-active grain boundaries or numerous subgrain boundaries within the grain bulk. In other isolated instances, the open-circuit voltage is reduced by excess space-charge recombination current that is not correlated with either grain or subgrain boundary activity.

Culik, J.↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications: Preprint

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaNbased DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

Electrolyte and Cutoff Potential Effects on Cycle Life of Li4Ti5O12/LiNi0.9Mn0.1O2 Batteries for Behind-the-Meter Storage Applications

Behind-the-Meter Storage (BTMS) is a stationary battery energy storage system that is connected to the electrical distribution system on the customer's side of the utility's service meter. BTMS systems are used to store electrical energy from the grid as well as inconstant, renewable energy, such as local solar and wind generation. A successful BTMS system will allow the customer to pair their energy generation and storage to optimize electrical consumption from the grid, improving reliability and minimizing cost. For BTMS applications, batteries must be designed and optimized with different set of criteria from other leading segments of the Li-ion battery market, like transportation, due the system being stationary and proximal to the residential or commercial building it's benefitting. BTMS applications prioritize safety, cost (low/no-critical materials), reliability (20-year calendar life), and durability (10,000 cycle life), while having the ability to (minimally) compromise energy density and rate capability. Lithium titanate (Li4Ti5O12-, LTO) is a promising anode candidate for BTMS applications due to its high safety and capacity retention, while maintaining a reasonable 160 mAhg-1 reversable capacity and composition of relatively abundant materials. (1) Specifically, LTO has a high working voltage which helps to prevent Li dendrite formation, improving safety. Furthermore, LTO also has negligible lithiation-based volume change, leading to less mechanical pulverization, or loss of active material, upon cycling. For the cathode, materials with little or no Co are of high interest due to the high cost and low abundance of Co. LiMn2O4 (LMO) has been paired with LTO for BTMS applications in the past due to its safety, low cost (abundancy), and reasonably high operating voltage. (2-4) However, the low capacity of LMO limits energy density and specific energy. While not the highest priority for BTMS applications, increasing energy density will enable deployment in space constrained BTMS applications and decrease total cost. LiNi0.9Mn0.1O2 (LN-MO) is a recently developed material with promise due to its high operating voltage and relatively low price. (5) However, Ni-rich layered oxides, including LNMO, tend to struggle with capacity retention during high-voltage cycling due to mechanical pulverization, irreversible phase transitions, and unstable solid-electrolyte interphase. The study presented here focuses on building an understanding of how electrolyte solvent and varied cutoff potentials will impact the cycle life of LTO/LN-MO cells. Specifically, a comparison is provided between ethylene carbonate (EC), ethyl methyl carbonate (EMC), fluoroethylene carbonate (FEC), and Gen2 electrolyte solvents with 1M Lithium hexafluorophosphate (LiPF6) salt, cycling to two upper termination potentials, 2.6V and 2.7V. Electrochemical testing and diagnostics (e.g., differential capacity analysis, area specific impedance, constant voltage hold, and rate capability) and post-mortem characterization will be used to understand the aging behavior and failure mechanisms of the 8 cell combinations (four electrolytes and two voltage cutoffs). Cells with FEC electrolyte showed a lower initial capacity compared to cells with Gen2, EMC, and EC cycling at both voltages; however, the cells with FEC showed consistent trends in capacity retention with 2.6V and 2.7V termination potentials, while the cells with the other electrolytes showed much higher rates of capacity loss when cycling to the higher voltage. These results indicate that FEC may play a role in improving durability of high-voltage, Ni-rich electrode systems for use in high-cycle applications, such as BTMS.

electrolyte↗

Design, Optimization, and Validation of GaN-Based DAB Converter for Active Cell Balancing in BTMS Applications

This paper focuses on the design of a bidirectional dual active bridge (DAB) DC/DC converter that utilizes Gallium Nitride (GaN) switches as active components. In the existing literature, MOSFET-based DAB for active cell balancing is available, but GaN-based DAB converter for active cell balancing is still new. The proposed modular isolated GaN-based DAB converter is designed as an individual module of active cell balancing for behind-the-meter storage (BTMS) applications, targeting high-power charging stations. Modular isolated converters are connected to each cell (low voltage bus), and each cell is connected in series to build up a battery module. According to the reference current command of supervisory control, each DAB converter can transfer power back and forth through the high voltage (HV) bus to balance the State of Charge (SoC) between the cells. Each module DAB converter is designed at a 50 W power rating. Switch power and transformer losses are analyzed for different switching frequencies, showing the optimum switching frequency for minimum losses. Furthermore, the procedure to select the required gate driver and the PCB layout optimization are discussed. Finally, the DAB performance analysis of GaN-based DAB and Si-based DAB is provided for a battery module operating with a LiFeMnPO4 prismatic cell with 3.2V 20Ah rated values.

active cell balancing↗

A Secondary Control Framework for Microgrid Interoperability With Vendor-Agnostic Grid-Forming Units: Design, Implementation, and Demonstration via Large-Scale Hardware Setup

The reliable operation of islanded microgrids increasingly depends on secondary controls that restore voltage and frequency to nominal values and ensure accurate active and reactive power sharing. Centralized secondary control architectures achieve high accuracy through global coordination at the cost of single-point failures and limited scalability compared with decentralized/distributed approaches. But a critical gap remains in addressing the interoperability and vendor-agnostic operation of secondary controls in real-world microgrids where heterogeneous diesel generator(s) and grid-forming (GFM) inverter(s) from multiple manufacturers always coexist. Practical and vendor-agnostic interoperability guidelines for the secondary control architecture of microgrids with multiple GFM units have not yet been developed; therefore, this paper proposes an interoperable and vendor-agnostic secondary control framework that operates seamlessly across GFM units from different vendors without relying on proprietary controls and protocols, hardware, or lock-ins. The framework leverages existing communication infrastructures (e.g., Modbus TCP/IP) to enable cost-effective deployment while addressing practical challenges, such as packet loss and quantization errors. Mitigation strategies-including data averaging, situational event-triggered control, and finite-iteration execution-are introduced to enhance reliability under real-world conditions. A generalized modeling and design framework is also presented, supported by robustness analysis to demonstrate independence from vendor-specific implementations. The proposed framework is validated through a large-scale hardware demonstration using a 3-$\phi$, 480-V, 60-Hz, 713-kVA laboratory hardware microgrid involving a heterogeneous diesel generator and multiple GFM inverters, showcasing its effectiveness in achieving stable voltage and frequency restoration and accurate power sharing under practical constraints. The results highlight the framework's potential as a scalable and practical solution for next-generation microgrids requiring openness, standard framework, and interoperability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Halting Oxygen Evolution to Achieve Long Cycle Life in Sodium Layered Cathodes

Oxygen redox chemistries at high voltage have materialized as a revolutionary paradigm for cathodes with high-energy density; however, they are plagued by the challenges of labile oxygen loss and rapid degradations upon cycling, even after concerted endeavors from the research community. Here we propose a multi-concentration stratagem propelled by entropy reinforcement to enhance the electronic structure disorder (ESD) at high desodiation states for impeding undesired oxygen mobility and ensuring controlled oxygen activity, elucidated by density functional theory calculations. The increased disorder strengthens the reversible electrochemistry of lattice oxygen redox, leading to effectively suppressed P−O structural evolution and highly stable localized TMO 6 octahedral environments, as demonstrated by soft/hard X-ray absorption spectroscopy. Furthermore, through a comparative analysis of sodium-layered cathodes with different configuration entropy, we reveal that a high-entropy state induced by cationic disordering has the capacity to perturb cationic redox boundaries, significantly restraining the formation of detrimental O′3 phases. As a consequence, the high-voltage cycling stability has been greatly upgraded, up to 4.4 V versus Na + /Na, with an impressive 90.1 % capacity retention at 1 C over 100 cycles and 76.1 % capacity retention at 2 C over 300 cycles. In conclusion, the resilient oxygen redox, enabled through the control of ESD, broadens the horizons for entropy engineering and lays the foundation for advancements in high-energy, long-cycling, and safe batteries.

25 ENERGY STORAGE↗

Near surface defects: Cause of deficit between internal and external open-circuit voltage in solar cells

The presence of interface recombination in a complex multilayered thin-film solar structure causes a disparity between the internal open-circuit voltage (V OC,in ), measured by photoluminescence, and the external open-circuit voltage (V OC,ex ) i.e. an additional V OC deficit. Higher V OC,ex value aim require a comprehensive understanding of connection between V OC deficit and interface recombination. Here, a deep near-surface defect model at the absorber/buffer interface is developed for copper indium di-selenide solar cells grown under Cu excess conditions to explain the disparity between V OC ,in and V OC,ex . The model is based on experimental analysis of admittance spectroscopy and deep-level transient spectroscopy, which show the signature of deep acceptor defect. Further, temperature-dependent current-voltage measurements confirm the presence of near surface defects as the cause of interface recombination. The numerical simulations show strong decrease in the local V OC ,in near the absorber/buffer interface leading to a V OC deficit in the device. This loss mechanism leads to interface recombination without a reduced interface bandgap or Fermi level pinning. Further, these findings demonstrate that the V OC ,in measurements alone can be inconclusive and might conceal the information on interface recombination pathways, establishing the need for complementary techniques like temperature dependent current voltage measurements to identify the cause of interface recombination in the devices.

14 SOLAR ENERGY↗

Comprehensive model for evaluating voltage losses and performance improvements in thin-film photovoltaic devices

Progress of state-of-the-art and next-generation thin-film photovoltaic devices is often stymied by open-circuit voltage (𝑉 oc ) that is significantly lower than theoretical and practical limits. Yet, effectively diagnosing the primary sources of voltage loss remains challenging. Herein, a sequence of device-level characterization techniques and simulations are employed to identify and rank loss mechanisms. For the research-based Cd⁡(Se,Te) device under study, most of the loss was at the front semiconductor heterointerface due to a clifflike conduction-band offset that lowered the recombination activation energy. Additional losses due to band tails were quantified by photoluminescence analysis. The latter provided the absorption coefficient and activation energy reduction associated with band tails as inputs to device models. Simulations showed that alleviating front-interface issues would improve 𝑉 oc , but it would then be limited by bulk recombination. Further improvement of the bulk would then lead to back-contact limitations. Reducing band tails is beneficial in any circumstance. In conclusion, this analysis provides guidance for reaching toward the radiative 𝑉 oc limit.

14 SOLAR ENERGY↗

Analysis of High Frequency AC Link Isolated Three Port Resonant Converter for UAV Applications

A high frequency AC link isolated three port semi-bridgeless resonant converter is analyzed for unmanned aerial vehicle (UAV) applications in this study. The proposed topology is established by replacing rectifier lover diodes with synchronous switches. A phase shifted pulse width modulation (PS-PWM) technique adjusts bi-directional power flow between ports. Proposed control technique provides high efficiency by reducing switching losses with zero voltage switching (ZVS) and zero current switching (ZCS) in a wide power range regulation. Compared to integrated PWM converters in a bi-directional mode, the proposed topology reduces the number of converter stages and allows centralized control at high operating frequency. Theoretical and experimental results demonstrate the feasibility and effectiveness of the proposed converter at a full power of 500 W in laboratory conditions.

Asa, Erdem↗

Power Operations of the Mars Exploration Rovers

The rovers of the National Aeronautics and Space Administration’s (NASA) Mars Exploration Rovers (MER) project, Spirit (MER-A) and Opportunity (MER-B), safely landed on the surface of Mars three weeks apart during January 2004. Spirit and Opportunity were built and operated by the Jet Propulsion Laboratory (JPL), which is managed by the California Institute of Technology (Caltech) for NASA. Spirit landed at Gusev Crater, 14.8 degrees south of the equator, and operated continuously on the surface of Mars from January 4, 2004 until last contact from Spirit on March 22, 2010. Opportunity landed at Meridiani Planum, a location 2.5 degrees south of the Martian equator. Opportunity operated continuously on the Martian surface from January 25, 2004 until the last received transmission from Opportunity on June 10, 2018. The goal of the MER project was to determine if Mars ever had a habitable environment, in particular, if it ever had water. During their missions, both Spirit and Opportunity found evidence that liquid water once flowed on the surface of Mars. Both Spirit and Opportunity used a 1.33 m2 triple-junction solar array as their power sources. Based on observations of the original Mars rover, the Sojourner rover of the Mars Pathfinder mission that landed on Mars on July 4, 1997, the expectation was that the Martian dust would rapidly accumulate on the solar arrays of Spirit and Opportunity, and that the rovers would not have enough energy to continue operations after 90 Martian days (sols). Instead, due in part to lower dust accumulation rates than expected and numerous dust cleaning events, the Spirit and Opportunity rovers continued to operate on the Martian surface for over 2000 sols (MER-A) and 5000 sols (MER-B), respectively. During this time, the rovers experienced multiple Martian winters and several dust storms. Because the sources of solar array energy loss were known, the solar array energy output offered a method to scientifically estimate the loading and aeolian removal of dust from the solar arrays each sol. The MER Power operations team called this value that they calculated the solar array Dust Factor (DF). Dust Factor was defined as the fraction of sunlight that penetrates the accumulated dust on the surface of the solar array. A Dust Factor of 1.0 would indicate that the solar array was perfectly clean. A Dust Factor of 0.6 would indicate that only 60% of the available sunlight was able to penetrate the accumulated dust on the solar arrays. The MER Power subsystem operations team used the Multi-Mission Power Analysis Tool (MMPAT) to perform these Dust Factor calculations. The MMPAT software tool modeled the behavior of the solar arrays and the batteries as they interacted with the spacecraft power loads over the mission timeline. MMPAT also had knowledge (through telemetry and user inputs) of telemetered Power subsystem voltages and currents, atmospheric opacity (Tau), rover surface location, rover attitude, the planetary tilt and distance of Mars from the sun based on day of year, the instantaneous elevation of the sun based on time of day, temperatures (internal and external), terrain masking, and shadowing (due to the camera mast and antennas). Once all of the known sources of array energy loss are accounted, the remaining difference between the expected array energy and the actual array energy determines the solar array Dust Factor. The assumptions made while determining the Dust Factor are 1) that the single measured atmospheric opacity value (Tau) is constant over the course of the entire sol, 2) there is no measurable solar cell degradation, 3) there are no shorted strings and therefore, 4) all unexpected solar array energy losses are due to accumulated dust on the solar array. Although it cannot provide an absolute measure of dust loading, the determination of solar array Dust Factor provides a useful way of tracking dust accumulation and aeolian dust removal trends on Martian spacecraft. Any spacecraft on the Martian surface is vulnerable to dust, especially solar-powered spacecraft. The Spirit and Opportunity rovers were operational on the Martian surface for much longer than expected due in part to aeolian removal of dust from their solar arrays. The first few dust removal events were a pleasant surprise to the MER operations teams; however, over time a pattern began to arise. In over three Mars Years on the surface, the Power operations team tracked the solar array Dust Factor at Gusev Crater (location of MER-A) and observed that there were several significant dust removal and deposition events in Mars Year (MY) 27, even in the absence of a large dust storm. In MY 28 at Gusev Crater, the large atmospheric opacity (Tau) increase lagged significant dust removal events. Overall at Gusev Crater, there was a pattern of steady dust accumulation on the solar arrays, with a small number of significant dust cleaning events. At Meridiani Planum, where Opportunity rover operated for over seven Mars Years (late MY 26 to mid MY 34), a clear and consistent pattern of dust movement emerged. Meridiani Planum had a predictable, seasonally dependent pattern of gradual and continuous dust accumulation and removal. In summary, this paper explains the reasons for the development of the solar array Dust Factor and how it was used in mission operations. In particular, this paper describes the MMPAT software package, how it models array energy, including the important assumptions, model inputs and sources of error. And finally, this paper will show how the calculated solar array Dust Factor was used at Gusev Crater and Meridiani Planum to predict dust accumulation rates and weather patterns, and the importance of this generated data set for current and future solar- powered missions to Mars, such as the InSight lander and the planned Mars Sample Return rover.

Chin, Keith B.↗

Evaluating switch lifetime in soft-switched single-stage differential-mode SST

The reliability of semiconductor switches in single-stage differential-mode solid-state transformers (DM-SSTs) has not been systematically evaluated under soft-switching operation and realistic grid conditions. This paper presents a switch-level reliability analysis for soft-switched and hard-switched DM-SST configurations by integrating converter-specific power loss modeling with empirical lifetime prediction. Analytical derivation of device current profiles specific to the DM-SST is used to characterize electrothermal stress, which is then mapped to lifetime using degradation models obtained from power cycling tests (PCTs). Applied to realistic SST load profiles and grid voltage variations, this approach provides a probabilistic prediction of switch lifetime for the DM-SST. Lifetime estimates for both SiC MOSFETs and Si IGBTs are presented, offering insight into device degradation under converter operating conditions. The results quantify the reliability benefits of soft switching in single-stage SSTs, highlighting how switching dynamics influence long-term switch degradation.

14 SOLAR ENERGY↗

Comprehensive Efficiency Analysis of Current Source Inverter Based on CSI-Type Double Pulse Test and Genetic Algorithm

A current-source inverter (CSI) has a natural output voltage boost feature that can be advantageous for traction applications. Switching frequency is one of the easily-controlled variables that can be adjusted to improve the CSI efficiency at different operating points when the boost function is used. This paper investigates a CSI-based double-pulse test (DPT) measurement that mimics normal operation of the CSI. A loss model of the CSI is developed based on the CSI-type DPT experimental results. The impacts of the switching frequency and voltage boost ratio on the CSI efficiency and output voltage ripple are investigated. Based on the loss model, a genetic algorithm has been introduced that makes it possible to optimize the CSI's switching frequency and modulation index to maximize its efficiency under any desired operating condition.

current-source inverter, genetic algorithm, SPM ma↗

Steady-state analysis of a faulted three-phase four-wire system supplying induction motors with neutrals connected and other single-phase line-to-neutral loads

Four wire Wye connected ac power systems exhibit peculiar steady state fault characteristics when the fourth wire of three phase induction motors is connected. The loss of one phase of power source due to a series or shunt fault results in currents higher than anticipated on the remaining two phases. A theoretical approach to compute the fault currents and voltages is developed. A FORTRAN program is included in the appendix.

Wood, M. E.↗

Design of BLDC Motor Diagnostic Device Based on Surge Test for Phase to Ground Fault

BLDC motor is essential in the industrial world, especially it been used for an electric vehicle. The benefit of using BLDC motor is that it has high rate efficiency and low mechanical losses. However, to know the isolation condition of winding and increase reliability, it needs to be tested. With the implementation of surge test based fault detection device of BLDC motor, the condition of BLDC motor can be monitored and maintained according to analysis of its condition. The surge test method used because it is sensitive in detecting the initial damage in the isolation failure process on stator winding. A surge voltage is generated from the Cockroft-Walton and switching circuit with capacitors. The result is analyzed using Error Area Ratio (EAR). The test result shows that the higher the value of resistance and inductance, the smaller the frequency of the surge wave. When the BLDC motor in a parallel short circuit condition, the threshold value of the EAR test-reff has a minimum value of 5.28%, an average of 13.52%, and a maximum of 28.55%.

BLDC motor↗