Search NASA⌕ Search

SEARCH · Search NASA

Results for “volume tracking”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

SU-D-18A-04: Quantifying the Ability of Tumor Tracking to Spare Normal Tissue

Purpose: Tumor tracking allows for smaller tissue volumes to be treated, potentially reducing normal tissue damage. However, tumor tracking is a more complex treatment and has little benefit in some scenarios. Here we quantify the benefit of tumor tracking for a range of patients by estimating the dose of radiation to organs at risk and the normal tissue complication probability (NTCP) for both standard and tracking treatment plans. This comparison is performed using both patient 4DCT data and extended Cardiac-Torso (XCAT) digital phantoms. Methods: We use 4DCT data for 10 patients. Additionally, we generate digital phantoms with motion derived from measured patient long tumor trajectories to compare standard and tracking treatment plans. The standard treatment is based on the average intensity projection (AIP) of 4DCT images taken over a breath cycle. The tracking treatment is based on doses calculated on images representing the anatomy at each time point. It is assumed that there are no errors in tracking the target. The NTCP values are calculated based on RTOG guidelines. Results: The mean reduction in the mean dose delivered was 5.5% to the lungs (from 7.3 Gy to 6.9 Gy) and 4.0% to the heart (from 12.5 Gy to 12.0 Gy). The mean reduction in the max dose delivered was 13% to the spinal cord (from 27.6 Gy to 24.0 Gy), 2.5% to the carina (from 31.7 Gy to 30.9 Gy), and 15% to the esophagus (from 69.6 Gy to 58.9 Gy). The mean reduction in the probability of 2nd degree radiation pneumonitis (RP) was 8.7% (3.1% to 2.8%) and the mean reduction in the effective volume was 6.8% (10.8% to 10.2%). Conclusions: Tumor tracking has the potential to reduce irradiation of organs at risk, and consequentially reduce the normal tissue complication probability. The benefits vary based on the clinical scenario. This study is supported by Varian Medical Systems, Inc.

60 APPLIED LIFE SCIENCES↗

L1 track triggers for ATLAS in the HL-LHC

The HL-LHC, the planned high luminosity upgrade for the LHC, will increase the collision rate in the ATLAS detector approximately a factor of 5 beyond the luminosity for which the detectors were designed, while also increasing the number of pile-up collisions in each event by a similar factor. This means that the level-1 trigger must achieve a higher rejection factor in a more difficult environment. This presentation discusses the challenges that arise in this environment and strategies being considered by ATLAS to include information from the tracking systems in the level-1 decision. The main challenges involve reducing the data volume exported from the tracking system for which two options are under consideration: a region of interest based system and an intelligent sensor method which filters on hits likely to come from higher transverse momentum tracks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Deterministic Simulation of First-Order Scattering in a Clinical X-ray Computed Tomography Scanner - Paper 81

In nondestructive testing (NDT) and medical diagnostic x-ray imaging (photon energy<140 keV), scattered x-ray caused by Compton and Rayleigh scattering should be eliminated. Scattered x-ray photons reduce image contrast, increase image noise, and introduce artifact into the reconstructed computed tomography (CT) images. In cone-beam CT, where the coverage of the x-ray beam and the area of the detector are significantly larger than those in fan-beam CT, x-ray photon scatter is one of the major sources of image degradation. The artifacts caused by scattered x-ray photon can be divided into two categories: 1) low spatial frequency scatter profile adds a positive bias to the detected radiation signal, thus reducing the effective attenuation of the imaged object, resulting in a negative bias in the measured linear attenuation coefficient in the image; 2) a high spatial frequency scatter profile causes a differential artifact, such as shading in uniform regions. A real x-ray scan is composed of both low and high frequency scatter profiles. Thus, the key to a successful scatter correction is the ability to accurately capture the scatter profile of a real x-ray imaging scan. The most accurate method for estimating a scatter profile is the Monte Carlo simulation. However, the computation cost of the Monte Carlo method makes it unfeasible for simulating real and complex scan geometries in clinical settings. A practical yet accurate scatter profile estimation method is through ray tracing techniques, where the scatter profiles are computed by tracking rays through the object's volume. The x-ray from the source is tracked when it interacts with the material in the volume. The interaction creates scattered x-rays, in all possible directions. These rays are again either attenuated or scattered, creating cascaded scatter events. In x-ray CT, the first-order scattering (where only one scatter interaction is encountered) accounts for the most severe image artifacts since this first-order scatter contains a high frequency component of the scatter profile. Previous studies have shown that ray tracing techniques are quite effective in simulating the contribution of first-order scattering in radiological images. In this study, a similar ray tracing technique is applied to simulate the scatter profile of a real x-ray computed tomography (CT) scan in clinical settings. A good agreement has been found between the simulated scatter profile and the experimental measurement result. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Tracking and data systems support for the Helios project. Volume 1: Project development through end of mission, phase 2

The overall evolution of the Helios Project is summarized from its conception through to the completion of the Helios-1 mission phase 2. Beginning with the project objectives and concluding with the Helios-1 spacecraft entering its first superior conjunction (end of mission phase 2), descriptions of the project, the mission and its phases, international management and interfaces, and Deep Space Network-spacecraft engineering development in telemetry, tracking, and command systems to ensure compatibility between the U.S. Deep Space Network and the German-built spacecraft are included.

Goodwin, P. S.↗

Three-dimensional track reconstruction for directional Dark Matter detection

Directional detection of Dark Matter is a promising search strategy. However, to perform such detection, a given set of parameters has to be retrieved from the recoiling tracks: direction, sense and position in the detector volume. In order to optimize the track reconstruction and to fully exploit the data of forthcoming directional detectors, we present a likelihood method dedicated to 3D track reconstruction. This new analysis method is applied to the MIMAC detector. It requires a full simulation of track measurements in order to compare real tracks to simulated ones. We conclude that a good spatial resolution can be achieved, i.e. sub-mm in the anode plane and cm along the drift axis. This opens the possibility to perform a fiducialization of directional detectors. The angular resolution is shown to range between 20° to 80°, depending on the recoil energy, which is however enough to achieve a high significance discovery of Dark Matter. On the contrary, we show that sense recognition capability of directional detectors depends strongly on the recoil energy and the drift distance, with small efficiency values (50%–70%). We suggest not to consider this information either for exclusion or discovery of Dark Matter for recoils below 100 keV and then to focus on axial directional data.

79 ASTRONOMY AND ASTROPHYSICS↗

Effects of target fragmentation on evaluation of LET spectra from space radiation in low-earth orbit (LEO) environment: impact on SEU predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

STS-51 Shuttle Project↗

Effects of Target Fragmentation on Evaluation of LET Spectra From Space Radiation in Low-Earth Orbit (LEO) Environment: Impact on SEU Predictions

Recent improvements in the radiation transport code HZETRN/BRYNTRN and galactic cosmic ray environmental model have provided an opportunity to investigate the effects of target fragmentation on estimates of single event upset (SEU) rates for spacecraft memory devices. Since target fragments are mostly of very low energy, an SEU prediction model has been derived in terms of particle energy rather than linear energy transfer (LET) to account for nonlinear relationship between range and energy. Predictions are made for SEU rates observed on two Shuttle flights, each at low and high inclination orbit. Corrections due to track structure effects are made for both high energy ions with track structure larger than device sensitive volume and for low energy ions with dense track where charge recombination is important. Results indicate contributions from target fragments are relatively important at large shield depths (or any thick structure material) and at low inclination orbit. Consequently, a more consistent set of predictions for upset rates observed in these two flights is reached when compared to an earlier analysis with CREME model. It is also observed that the errors produced by assuming linear relationship in range and energy in the earlier analysis have fortuitously canceled out the errors for not considering target fragmentation and track structure effects.

Shinn, J. L.↗

Comparison between target margins derived from 4DCT scans and real-time tumor motion tracking: Insights from lung tumor patients treated with robotic radiosurgery

Purpose: A unique capability of the CyberKnife system is dynamic target tracking. However, not all patients are eligible for this approach. Rather, their tumors are tracked statically using the vertebral column for alignment. When using static tracking, the internal target volume (ITV) is delineated on the four-dimensional (4D) CT scan and an additional margin is added to account for setup uncertainty [planning target volume (PTV)]. Treatment margins are difficult to estimate due to unpredictable variations in tumor motion and respiratory pattern during the course of treatment. The inability to track the target and detect changes in respiratory characteristics might result in geographic misses and local tumor recurrences. The purpose of this study is to develop a method to evaluate the adequacy of ITV-to-PTV margins for patients treated in this manner. Methods: Data from 24 patients with lesions in the upper lobe (n = 12), middle lobe (n = 3), and lower lobe (n = 9) were included in this study. Each patient was treated with dynamic tracking and underwent 4DCT scanning at the time of simulation. Data including the 3D coordinates of the target over the course of treatment were extracted from the treatment log files and used to determine actual target motion in the superior–inferior (S–I), anterior–posterior (A–P), and left–right (L–R) directions. Different approaches were used to calculate anisotropic and isotropic margins, assuming that the tumor moves as a rigid body. Anisotropic margins were calculated by separating target motion in the three anatomical directions, and a uniform margin was calculated by shifting the gross tumor volume contours in the 3D space and by computing the percentage of overlap with the PTV. The analysis was validated by means of a theoretical formulation. Results: The three methods provided consistent results. A uniform margin of 4.5 mm around the ITV was necessary to assure 95% target coverage for 95% of the fractions included in the analysis. In the case of anisotropic margins, the expansion required in the S–I direction was larger (8.1 mm) than those in the L–R (4.9 mm) and A–P (4.5 mm) directions. This margin accounts for variations of target position within the same treatment fraction. Conclusions: The use of bony alignment for CyberKnife lung stereotactic body radiation therapy requires careful considerations, in terms of the potential for increased toxicity or local miss. Our method could be used by other centers to determine the adequacy of ITV-to-PTV margins for their patients.

60 APPLIED LIFE SCIENCES↗

Tracking and data system support for the Viking 1975 mission to Mars. Volume 2: Launch through landing of Viking 1

Problems inherent in the deployment and management of a worldwide tracking and data acquisition network to support the two Viking Orbiters and two Viking Landers simultaneously over 320 million kilometers (200 million miles) of deep space are discussed. Activities described include tracking coverage of the launch phase, the deep space operations during the long cruise phase that occupied approximately 11 months, and the implementation of the a vast worldwide network of tracking sttions and global communications systems. The performance of the personnel, hardware, and software involved in this vast undertaking are evaluated.

Mudgway, D. J.↗

Particle tracking approach for transport in three-dimensional discrete fracture networks: Particle tracking in 3-D DFNs

The discrete fracture network (DFN) model is a method to mimic discrete pathways for fluid flow through a fractured low-permeable rock mass, and may be combined with particle tracking simulations to address solute transport. However, experience has shown that it is challenging to obtain accurate transport results in three-dimensional DFNs because of the high computational burden and difficulty in constructing a high-quality unstructured computational mesh on simulated fractures. We present a new particle tracking capability, which is adapted to control volume (Voronoi polygons) flow solutions on unstructured grids (Delaunay triangulations) on three-dimensional DFNs. The locally mass-conserving finite-volume approach eliminates mass balance-related problems during particle tracking. The scalar fluxes calculated for each control volume face by the flow solver are used to reconstruct a Darcy velocity at each control volume centroid. The groundwater velocities can then be continuously interpolated to any point in the domain of interest. The control volumes at fracture intersections are split into four pieces, and the velocity is reconstructed independently on each piece, which results in multiple groundwater velocities at the intersection, one for each fracture on each side of the intersection line. This technique enables detailed particle transport representation through a complex DFN structure. Verified for small DFNs, the new simulation capability enables numerical experiments on advective transport in large DFNs to be performed. As a result, we demonstrate this particle transport approach on a DFN model using parameters similar to those of crystalline rock at a proposed geologic repository for spent nuclear fuel in Forsmark, Sweden.

58 GEOSCIENCES↗

Study of a tracking and data acquisition system for the 1990's. Volume 1: User community characteristics

Projected 1990's experiments; navigation requirements and potentials; communications requirements associated with space experiments; alternative forecast options; and operational impacts on experiments are covered. A baseline of plans for the TDAS User Community, including a set of generic experiments developed to supplement existing planning for the 1990's time frame is generated. It includes extensive summaries of collected data, and a bibliography. The data are representative of inputs obtained from NASA planning sources through September 1981.

Mccreary, T.↗

Study of a tracking and data acquisition system for the 1990's. Volume 3: TDAS Communication Mission Model

A parametric description of the communication channels required between the user spacecraft to be supported and the user ground data systems is developed. Scenarios of mission models, which reflect a range of free flyers vs space platform usage as well as levels of NASA activity and potential support for military missions, and potential channel requirements which identify: (1) bounds on TDAS forward and return link data communication demand, and (2) the additional demand for providing navigation/tracking support are covered.

Mccreary, T.↗