Search NASA⌕ Search

SEARCH · Search NASA

Results for “vuv”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Polarization measurements in the Vacuum Ultraviolet using SUMI

This paper will describe the VUV polarization testing of the NSSTC Solar Ultraviolet Magnetograph (SUMI) optics. SUMI is being developed for a sounding rocket payload to prove the feasibility of making magnetic field measurements in the transition region. This paper will cover the polarization testing of the SUMI optics and the instrumental polarization of the VUV test facility.

West, E. A.↗

Effect of a Silicone Contaminant Film on the Transmittance Properties of AR-coated Fused Silica

We present the results of a laboratory test to determine the effects of bulk deposited, DC-704 silicone contaminant film on the transmittance properties of an anti-reflective (AR) coated fused silica optical substrate. Testing and optical measurements were performed in vacuum in the Boeing Combined Effects Test Facility (CETF). The test and measurement procedures are described herein. Measurement results are presented showing the change in transmittance characteristics as a function of contaminant deposit thickness and vacuum ultra-violet (vuv) exposure levels. Measurement results show an initial degradation in the transmittance of the contaminated sample. This is followed by a partial recovery in sample transmittance as the sample is exposed to additional VUV radiation. Transmittance results also show a loss of transmission in the ultraviolet portion of the spectrum and an increase in transmission in the infrared portion of the spectrum. These transmittance results are characteristic of thin-film interference effects. Thin-film analyses indicate that some of the observed transmittance results can be successfully modeled, but only if the contaminant film is assumed to be SiO2 rather than DC-704 silicone. Post-test Scanning Electron Microscope (SEM) scans of the test sample indicate the formation of contaminant islands and the presence of a thin uniform coating of contaminant deposit on the sample

Boeder, Paul A.↗

Overview of Space Environment Effects on Materials and GRC's Test Capabilities

The Electro-Physics Branch at NASA Glenn Research Center has been involved with evaluating the durability of materials and understanding environment interactions for over 20 years. A combination of flight experiments, ground based exposure facilities, and environmental modeling provide a well rounded approach to material durability evaluation and prediction for future missions. Ground based testing includes atomic oxygen exposure facilities (large and small area thermal facilities and directed atomic oxygen with and without VUV radiation, VUV and NUV exposure facility, and thermal cycling facility with and without UV radiation. A lunar dust exposure facility is also being brought on-line. Material reactions in these facilities is compared to that observed in space.

Banks, Bruce A.↗

Vacuum ultraviolet light source utilizing rare gas scintillation amplification sustained by photon positive feedback

A source of light in the vacuum ultraviolet (VUV) spectral region includes a reflective UV-sensitive photocathode supported in spaced parallel relationship with a mesh electrode within a rare gas at low pressure. A high positive potential applied to the mesh electrode creates an electric field which causes drifting of free electrons occurring between the electrodes and producing continuous VUV light output by electric field-driven scintillation amplification sustained by positive photon feedback mediated by photoemission from the photocathode. In one embodiment the lamp emits a narrow-band continuum peaked at 175 nm.

Aprile, Elena↗

CIV Polarization Measurements using a Vacuum Ultraviolet Fabry-Perot Interferometer

Marshall Space Flight Center's (MSFC) is developing a Vacuum Ultraviolet (VUV) Fabry-P rot Interferometer that will be launched on a sounding rocket for high throughput, high-cadence, extended field of view CIV (155nm) measurements. These measurements will provide (i) Dopplergrams for studies of waves, oscillations, explosive events, and mass motions through the transition region, and, (ii), polarization measurements to study the magnetic field in the transition region. This paper will describe the scientific goals of the instrument, a brief description of the optics and the polarization characteristics of the VUV Fabry P rot.

West, Edward↗

CIV Polarization Measurements Using a Vacuum Ultraviolet Fabry Perot

Marshall Space Flight Center's (MSFC) is developing a Vacuum Ultraviolet (VUV) Fabry Perot that will be launched on a sounding rocket for high throughput, high-cadence, extended field of view CIV (155nm) measurements. These measurements will provide (i) Dopplergrams for studies of waves, oscillations, explosive events, and mass motions through the transition region, and, (ii), polarization measurements to study the magnetic field in the transition region. This paper will describe the scientific goals of the instrument, a brief description of the optics and the polarization characteristics of the VUV Fabry Perot.

West, Edward A.↗

Photodiode-Based, Passive Ultraviolet Dosimeters

Simple, passive instruments have been developed for measuring the exposure of material specimens to vacuum ultraviolet (VUV) radiation from the Sun. Each instrument contains a silicon photodiode and a coulometer. The photocharge generated in the photodiode is stored in the coulometer. The accumulated electric charge measured by use of the coulometer is assumed to be proportional to the cumulative dose of VUV radiation expressed in such convenient units as equivalent Sun hours (ESH) [defined as the number of hours of exposure to sunlight at normal incidence]. Intended originally for use aboard spacecraft, these instruments could also be adapted to such terrestrial uses as monitoring the curing of ultraviolet-curable epoxies. Each instrument includes a photodiode and a coulometer assembly mounted on an interface plate (see figure). The photodiode assembly includes an aluminum housing that holds the photodiode, a poly(tetrafluoroehylene) cosine receptor, and a narrow-band optical filter. The cosine receptor ensures that the angular response of the instrument approximates the ideal angular response (proportional to the cosine of the angle of incidence). The filter is chosen to pass the ultraviolet wavelength of interest in a specific experiment. The photodiode is electrically connected to the coulometer. The factor of proportionality between the charge stored in the coulometer and ultraviolet dosage (in units of ESH) is established, prior to use, in calibration experiments that involve the use of lamps and current sources traceable to the National Institute of Standards and Technology.

Vaughn, Jason A.↗

Charging of Basic Structural Shapes in a Simulated Lunar Environment

In order to understand the effect of the charging environment on and around structures on the lunar surface, we have exposed basic structural shapes to electrons and Vacuum Ultra-Violet (VUV) radiation. The objects were, in separate runs, isolated, grounded, and placed on dielectric surfaces. In this presentation, the effects of electron energy, VUV flux, and sample orientation, on the charging of the objects will be examined. The potential of each of the object surfaces was monitored in order to determine the magnitude of the ram and wake effects under different orientations relative to the incoming beams (solar wind). This is a part of, and complementary to, the study of the group at USC under Dr. J. Wang, the purpose of which is to model the effects of the charging environment on structures on the lunar surface.

Craven, P.↗

Measurements and Modeling of Total Solar Irradiance in X-class Solar Flares

The Total Irradiance Monitor (TIM) from NASA's SOlar Radiation and Climate Experiment can detect changes in the total solar irradiance (TSI) to a precision of 2 ppm, allowing observations of variations due to the largest X-class solar flares for the first time. Presented here is a robust algorithm for determining the radiative output in the TIM TSI measurements, in both the impulsive and gradual phases, for the four solar flares presented in Woods et al., as well as an additional flare measured on 2006 December 6. The radiative outputs for both phases of these five flares are then compared to the vacuum ultraviolet (VUV) irradiance output from the Flare Irradiance Spectral Model (FISM) in order to derive an empirical relationship between the FISM VUV model and the TIM TSI data output to estimate the TSI radiative output for eight other X-class flares. This model provides the basis for the bolometric energy estimates for the solar flares analyzed in the Emslie et al. study.

Sun: chromosphere↗

Validation of High Speed Earth Atmospheric Entry Radiative Heating from 9.5 to 15.5 km/s

This paper presents an overview of the analysis and measurements of equilibrium radiation obtained in the NASA Ames Research Center's Electric Arc Shock Tube (EAST) facility as a part of recent testing aimed at reaching shock velocities up to 15.5 km/s. The goal of these experiments was to measure the level of radiation encountered during high speed Earth entry conditions, such as would be relevant for an asteroid, inter-planetary or lunar return mission. These experiments provide the first spectrally and spatially resolved data for high speed Earth entry and cover conditions ranging from 9.5 to 15.5 km/s at 13.3 and 26.6 Pa (0.1 and 0.2 Torr). The present analysis endeavors to provide a validation of shock tube radiation measurements and simulations at high speed conditions. A comprehensive comparison between the spectrally resolved absolute equilibrium radiance measured in EAST and the predictive tools, NEQAIR and HARA, is presented. In order to provide a more accurate representation of the agreement between the experimental and simulation results, the integrated value of radiance has been compared across four spectral regions (VUV, UV/Vis, Vis/NIR and IR) as a function of velocity. Results have generally shown excellent agreement between the two codes and EAST data for the Vis through IR spectral regions, however, discrepancies have been identified in the VUV and parts of the UV spectral regions. As a result of the analysis presented in this paper, an updated parametric uncertainty for high speed radiation in air has been evaluated to be [9.0%, -6.3%]. Furthermore, due to the nature of the radiating environment at these high shock speeds, initial calculations aimed at modeling phenomena that become more significant with increasing shock speed have been performed. These phenomena include analyzing the radiating species emitting ahead of the shock and the increased significance of radiative cooling mechanisms.

Equilibrium↗

Experimental and Numerical Investigation of Air Radiation in Superorbital Expanding Flow

To investigate air radiation in expanding flows and provide experimental data for validating associated computational models, experiments were conducted in the X2 expansion tunnel facility at the Centre for Hypersonics of the University of Queensland. A 54 turning angle wedge model was employed to generate steady expanding flows with in flow total enthalpies of 50.7, 63.4 and 75.4 MJkg. VUV spectra from 118 to 180 nm were acquired across the wedge at three equispaced distances away from the top of the model, as well as through its top surface. High speed filtered images were also obtained by coupling a Shimadzu 1 MHz high speed camera to a bandpass filter to obtain calibrated images of the 777 nm oxygen triplet. Both the across-wedge VUV spectra and filtered images of the 777 nm atomic oxygen were compared with NEQAIR simulations, which were performed using flow field data from two-dimensional CFD simulations with two-temperature 11-species air chemistry utilizing the in-house Navier-Stokes flow solver Eilmer3. Data extracted from consecutive frames of the filtered high speed images confirmed up to 8 s of available test time for the flow conditions tested. For the strongly radiating 149 and 174 nm atomic nitrogen lines, large disagreement between experimental data and NEQAIR predictions can be observed from the start of the expansion fan where the electron-ion recombination process commences. The spatial extent, or spans of the radiance profiles of the 149 and 174 nm N lines are significantly under predicted by NEQAIR, and are very close to those of N, N+ and electron number density profiles, which follow that of flow density. The electron-ion recombination process is proposed as the main reason for these discrepancies. The comparisons between NEQAIR simulations and filtered images of the 777 nm oxygen triplet show good agreement in the post-shock compression region and the start of the expansion fan for the 63.4 MJkg condition, but with up to a factor of three over prediction by NEQAIR further downstream, which is attributed to electron-impact excitation. Similar trends are found with the 75.4 MJkg condition, with reduced level of agreement in the compression region, which can be due to uncertainties in inflow condition.

Earth entry↗

Experimental and Numerical Investigation of Air Radiation in Superorbital Expanding Flow

To investigate air radiation in expanding flows and provide experimental data for validating associated computational models, experiments were conducted in the X2 expansion tunnel facility at the Centre for Hypersonics of the University of Queensland. A 54deg turning angle wedge model was employed to generate steady expanding flows with in flow total enthalpies of 50.7, 63.4 and 75.4 MJ/kg. VUV spectra from 118 to 180 nm were acquired across the wedge at three equispaced distances away from the top of the model, as well as through its top surface. High speed filtered images were also obtained by coupling a Shimadzu 1 MHz high speed camera to a bandpass filter to obtain calibrated images of the 777 nm oxygen triplet. Both the across-wedge VUV spectra and filtered images of the 777 nm atomic oxygen were compared with NEQAIR simulations, which were performed using flow field data from two-dimensional CFD simulations with two-temperature 11-species air chemistry utilising the in-house Navier-Stokes flow solver Eilmer3. Data extracted from consecutive frames of the filtered high speed images confirmed up to 8 s of available test time for the flow conditions tested. For the strongly radiating 149 and 174 nm atomic nitrogen lines, large disagreement between experimental data and NEQAIR predictions can be observed from the start of the expansion fan where the electron-ion recombination process commences. The spatial extent, or spans of the radiance profiles of the 149 and 174 nm N lines are significantly underpredicted by NEQAIR, and are very close to those of N, N+ and electron number density profiles, which follow that of flow density. The electron-ion recombination process is proposed as the main reason for these discrepancies. The comparisons between NEQAIR simulations and filtered images of the 777 nm oxygen triplet show good agreement in the post-shock compression region and the start of the expansion fan for the 63.4 MJ/kg condition, but with up to a factor of three overprediction by NEQAIR further downstream, which is attributed to electron-impact excitation. Similar trends are found with the 75.4 MJ/kg condition, with reduced level of agreement in the compression region, which can be due to uncertainties in inflow condition.

expansion tube↗

Full Facility Shock Frame Simulations of the Electric Arc Shock Tube

Radiative heating computations are performed for high speed lunar return experiments conducted in the Electric Arc Shock Tube (EAST) facility at NASA Ames Research Center. The nonequilibrium radiative transport equations are solved via NASA's in-house radiation code NEQAIR using flow field input from US3D flow solver. The post-shock flow properties for the 10 km/s Earth entry conditions are computed using the stagnation line of a blunt-body and a full facility CFD (Computational Fluid Dynamics) simulation of the EAST shock tube. The shocked gas in the blunt-body flow achieves a thermochemical equilibrium away from the shock front whereas EAST flow exhibits a nonequilibrium behavior due to strong viscous dissipation of the shock by boundary layer. The full-tube flow calculations capture the influence of the boundary layer on the shocked gas state and provide a realistic fluid dynamic input for the radiative predictions. The integrated radiance behind the shock is calculated in NEQAIR for wavelength regimes from Vacuum-UltraViolet (VUV) to InfraRed (IR), which are pertinent to the emission characteristics of high enthalpy shock waves in air. These radiance profiles are validated against corresponding EAST shots. The full-tube simulations successfully predict a sharp radiance peak at the shock front which gets smeared in the test data due to the spatial resolution in the measurements. The full facility based radiance behind the shock shows a slightly better match with the test data in the VUV and Red spectral regions, as compared to that from a blunt-body based predictions. The UV radiance is very similar for both geometries and under-predicts the test behavior. The IR test data matches better with the blunt-body based predictions where the full-tube simulations show a significant over-prediction.

Radiation↗

Characterization of CO 4th Positive Radiation in CO2-Ar Mixtures

This paper presents measurements and simulations of CO 4th Positive spectra obtained in NASA Ames Research Center's Electric Arc Shock Tube (EAST) and CentraleSupelec's Plasma Torch. The experiments were aimed at measuring optically thin emission for the main band features of CO 4th Positive by using test gas mixtures of CO2 and Ar. By using mixtures of CO2 and Ar, the temperature of the flow (and consequently black-body curve) is increased compared to using pure CO2 (or CO2 / N2 mixtures). This temperature increase allows for emission spectroscopy of features that would nominally be black-body limited for conditions relevant to Mars entry. The CO 4th Positive system is the focus of this study as it accounts for a large percentage of the emitted radiation for Martian entry, and also due to the difficulties of obtaining experimental validation data due to the emission appearing in the Vacuum Ultraviolet (VUV) spectral range. The focus of this paper is to provide a comprehensive comparison between the EAST and plasma torch data along with various CO 4th Positive databases available in the literature. Previously reported VUV CO2 / N2 EAST data required a larger temperature than would be predicted based upon equilibrium shock relations. The need for the temperature increase implies that the EAST experiment did not fully equilibrate. Thus, it is presumed that the EAST data did not obtain an equilibrium condition. The plasma torch data, on the other hand, is very consistent with equilibrium assumptions. Thus, the equilibrium data obtained in the plasma torch is utilized to construct the CO 4th Positive emission model, which is then applied to the EAST data with a non-equilibrium interpretation.

A. M. Brandis↗

Characterization of Modern Spacecraft Materials under Space-simulated Environment

External spacecraft materials play an important role in satellite protection from the harsh space environment. Research has shown that the physical, chemical, and optical properties of matter change continuously as a result of exposure to solar radiation and aggressive chemical species produced in Earth’s upper atmosphere. Thorough knowledge of the material properties evolution throughout a planned mission lifetime helps to improve the reliability of spacecraft. Moreover, the establishment of correlation factors between true space exposure and accelerated space weather experiments at ground facilities enables accurate prediction of on-orbit material performance based on laboratory-based testing. The presented work aims to evaluate the radiation effects of low Earth orbit (LEO) environment, namely, exposure to the high-energy electrons, atomic oxygen (AO), and vacuum ultraviolet (VUV), of several modern spacecraft materials. The studied materials represent the “flight duplicates” of samples that will be launched as a part of the Materials International Space Station Experiment Flight Facility (MISSE-FF) mission in 2022. MISSE-FF flight sample collection comprises different classes of polymers, including polyimides from the Kapton family, manufactured by E.I du Pont de Nemours and Co., Polyethylene terephthalate (PET) materials, liquid crystal polymers, PI/Polyhedral Oligomeric Silsesquioxanes (POSS), and carbon and glass fiber reinforced polymers. A sequential exposure approach was undertaken to allow monitoring of degradation induced by each environmental component (electrons, AO, and VUV) separately. Surface morphology, optical, and charge transport properties of selected materials were characterized using different techniques, namely, atomic force and scanning electron microscopy, ultraviolet visible (UV/Vis) transmission, reflectance, Bidirectional Reflectance Distribution Function (BRDF), and surface potential decay measurements.

Elena Plis↗

Soft X-ray/VUV diagnostic upgrades and installation on NSTX-U (Final Report)

Due to repeated delays in the schedule for the NSTX-U upgrade as well as the emergence of COVID and subsequent personnel loss during the granting period, the scope of the award was reduced to completing the refurbishment and upgrade of the JHU soft X-ray (SXR) and vacuum ultraviolet (VUV) diagnostics for the NSTX-U experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization of Lyman-(alpha) Radiation from Atomic Hydrogen Excited by Electron Impact from Near-Threshold to 1800eV

The polarization of Lyman-(alpha) radiation, produced by electron impact excitation of atomic hydrogen, has been measured for the first time over the extended energy range from near-threshold to 1800eV. Measurements were obtained in a crossed-beams experiment using a silica-reflection linear polarization analyzer in tandem with a vacuum ultraviolet (VUV) monochromator to isolate the emitted line radiation.

Lyman atomic line radiation Zeeman effect VUV pola↗

Evaluating the Importance of Conformers for Understanding the Vacuum-Ultraviolet Spectra of Oxiranes: Experiment and Theory

Vacuum-ultraviolet (VUV) absorption spectroscopy enables electronic transitions that offer the unambiguous identification of molecules. As target molecules become more complex, multifunctional species present a great challenge to both experimental and computational spectroscopy. This research reports both experimental and theoretical studies of oxiranes. Computationally, the nuclear ensemble approach has been used to accurately predict experimental spectra for a variety of molecules. However, this approach incurs great computational cost, as ensembles generally consist of thousands of geometries. The present study aims to drastically reduce the ensemble by evaluating the significance of the conformers to the predicted spectra. This approach was applied to 11 substituted oxiranes using the Conformer Rotamer Ensemble Sampling Tool (CREST) of Grimme to generate an ensemble of unique conformers determined by their Boltzmann populations. Five TD-DFT functionals (BMK, CAM-B3LYP, M06-2X, MN15, ωB97X-D) and EOM-CCSD were used to simulate the spectrum of each substituted oxirane ensemble. Computed spectra were then compared to the experiment using both qualitative and quantitative metrics. Based on these metrics, it was observed that certain conformers may not be necessary to characterize this set of oxiranes despite the temperature (323 K) of the experiment. A single conformer can then be used with TD-DFT and EOM-CCSD to replicate the experimental spectra of these medium-sized combustion species.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗