Search NASA⌕ Search

SEARCH · Search NASA

Results for “weather condition”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]↗

Evaluating grid stress and reliability in future electricity grids across a range of demand, generation mix, and weather trends

The reliability of power grids in the future will depend on how system planners account for the integration of new technologies, extreme weather events, and uncertainties in demand growth from increased electrification and data centers. This study introduces an open-source, multisectoral, multiscale modeling framework that projects grid stress and reliability trends between 2020 and 2055 in the Western Interconnection of the United States. The framework integrates global to national energy-water-land dynamics with power plant siting and hourly grid operations modeling. We analyze future wholesale electricity price shocks and unserved energy events across eight scenarios spanning a range of population growth and economic change, generation mixes, and weather conditions. Our results show future grids with high percentage of non-renewable generation and strong economic growth are characterized by higher reliability and lower wholesale electricity prices than lower growth scenarios because of larger reliance on dispatchable generators and lower fossil fuel extraction costs. Scenarios with high percentage of renewable resources have lower median but more volatile wholesale electricity prices as well as more frequent and severe unserved energy events compared to scenarios relying more on dispatchable generators. These events occur because higher proportion of solar and wind energy causes net demand curves to deepen during midday (duck curves get progressively severe), exacerbating the challenge of meeting demand during summer evening peaks. This study suggests that robust and co-optimized transmission and energy storage planning could help maintain low wholesale electricity prices and high reliability levels in future electricity grids across uncertainties in generation mixes.

Electric grid reliability↗

Growth modeling to evaluate alternative cultivation strategies to enhance national microalgal biomass production

In this paper, we present a model-based assessment of alternative cultivation strategies on algal biomass production within the conterminous United States. Our assessment focuses on two basic cultivation strategies: 1) seasonal rotation of three representative freshwater algal strains that are well suited for warm weather, cold weather, and all-season diverse weather conditions, respectively; and 2) variation between three open pond water depths (15cm, 20cm, and 25cm). The enhanced Biomass Assessment Tool (BAT) is applied on a site-specific, hourly basis at 5,832 North American Land Data Assimilation System Phase 2 1/8° meteorological model grid cells over a 30-year period (1980-2009) to evaluate the operational strategies. Recognizing that resource management decisions may also consider scales beyond the individual site, we also conduct a regional assessment of focused on 7 representative climate zones in the conterminous United States. Results demonstrate that the spatial variability of algal productivity is largely affected by the strain-specific growth response to light and temperature that vary significantly by climate zone and latitude. Therefore, with a limited set of alternative cultivation strategies, the BAT identified the best performing combination of cultivation strategies on a site-specific basis that considerably enhances national annual biomass productivity. Specifically, the appropriate choice of seasonal strain rotation is able to significantly dampen climate-driven seasonal and spatial variability.

59 BASIC BIOLOGICAL SCIENCES↗

Self-cleaning and de-pollution efficacies of photocatalytic architectural membranes

Photocatalytic self-cleaning “cool” roofs and walls can maintain high albedos, saving building cooling energy, reducing peak power demand, and mitigating the urban heat island effect. Other environmental benefits result from their de-polluting properties. Specimens from two different photocatalytic architectural membranes and a non-photocatalytic control were exposed alongside vertically, facing west, for two years at three California sites, and retrieved quarterly for testing. Photocatalytic materials showed excellent self-cleaning performance, retaining albedos of 0.74 – 0.75. By contrast, the control material exhibited an albedo loss of up to 0.10, with appreciable soiling observed by scanning electron microscopy. De-pollution capacity was assessed by quantifying NO removal and NOx deposition rates at 60 °C. Furthermore, efficacy varied with exposure location, weather conditions, and the nature of the photocatalytic material. Seasonal effects were observed, with partial inhibition during the dry season and reactivation during the rainy season.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Convolutional neural networks for intra-hour solar forecasting based on sky image sequences

Accurate and timely solar forecasts play an increasingly critical role in power systems. Compared to longer forecasting timescales, very short-term solar forecasting has lagged behind in both research and practice. In this paper, we propose deep convolutional neural networks (CNNs) to provide operational intra-hour (10-minute-ahead to 60-minute-ahead) solar forecasts. We develop two CNN structures inspired by a widely-used CNN architecture. The CNNs are tailored to our solar forecasting regression tasks and rely solely on sky image sequences. Case studies based on six years of data (over 150,000 data points) demonstrate that the best CNN model has forecast skill scores of 20%-39% over the naive persistence of cloudiness benchmark, even at these very short timescales. The CNNs also have consistently superior performance when compared to shallow machine learning models with meteorological predictors, where the improvement averages around 7%. The sensitivity analyses show that the sky image length, resolution, and weather conditions have impacts on the deep learning model accuracy. In our intra-hour problem with specific setups, two sky images with a 10-minute 128 x 128 resolution yield the most accurate forecasts. Current limitations, future work, and deployment challenges and solutions are also discussed.

14 SOLAR ENERGY↗

Heating performance of a vapor compression heat pump cascaded with a thermoelectric heat pump

Air source heat pumps (ASHPs) are widely utilized for heating and cooling in residential buildings; however, their effectiveness in heating mode is compromised during extreme weather conditions. Extensive research endeavors have been undertaken to develop, test, and assess a cost-effective vapor compression ASHP suitable for cold climate regions. Further, this study takes an innovative approach by developing component and system prototypes for a cold climate heat pump. This design combines a thermoelectric heat pump (TEHP) with a traditional residential split ASHP to augment heating capacity in low ambient temperature conditions. The component and system prototypes underwent experimental testing in the psychrometric chambers. The experimental findings revealed a 13.6% to 13.7% increase in total heat pump heating capacity, accompanied by a 3.1% to 5.0% decrease in the coefficient of performance (COP) at ambient temperatures of -15°C and -19°C, when compared to the original ASHP. The COP of the TEHP is relatively constant, ranging from 1.63 to 1.76. This prototype offers a solution to address the challenges associated with reduced heat pump capacity at low ambient temperatures. The experimental results indicated that the lower the ambient temperature, thermoelectric heat pump auxiliary heating can increase the heating efficiency 60% in comparison to electric resistance.

42 ENGINEERING↗

Evapotranspiration of advanced perennial bioenergy grasses produced on marginal land in the U.S. Midwest

The production of dedicated energy crops for biofuel and co-products can help develop a sustainable and viable bioeconomy under a changing climate. The co-production of perennial bioenergy and commodity crops in an agricultural landscape has the potential to reduce greenhouse gas emissions and provide numerous ecosystem services. However, as production of advanced, higher-yielding cultivars occurs, their impact on water resources needs to be considered. Estimates of evapotranspiration (ET) of perennial grasses compared to commodity crops are not always consistent in the literature. In this study, ET was estimated using an energy-balance model with Landsat satellite imagery and ground-based weather data to compare the large-scale production of advanced switchgrass cultivars (‘Independence’, ‘Liberty’, and ‘Carthage’), predecessor cultivars (‘Shawnee’ and ‘Sunburst’), and other perennial grasses (big bluestem and a low-diversity mixture) to corn grown continuously on marginal soils in the U.S. Midwest. Results showed significant differences in ET between corn and perennial grass treatments at four of the five field sites. However, differences between crop treatments were not consistent across sites, nor were the differences between advanced and predecessor switchgrass varieties. Production year played a large role in daily and cumulative ET across all sites. Differences in crop biomass yield between establishment and post-establishment years may contribute to these interannual differences. Site and interannual variations in precipitation and temperature may also be major contributing factors. Overall, the results of this study indicate that differences in ET between perennial bioenergy grasses and corn are likely dependent upon location of production and weather conditions.

09 BIOMASS FUELS↗

Regional difference and related cooling electricity savings of air pollutant affected natural ventilation in commercial buildings across the US

Maintaining indoor air pollutants under acceptable levels is significant to protect occupants from exposure to excessive air pollutants in natural ventilation. In this paper, using the representative air pollutant concentration data, we present the natural ventilation usability with associated cooling energy saving potentials in different location settings (urban and city center, suburban and rural) of the US under the influence of local weather conditions and major outdoor air pollutants, i.e. PM2.5, PM10 and ozone. It is found that the impacts of air pollutants on natural ventilation are usually higher in urban/suburban areas than rural areas (up to 25% difference) with the PM2.5 being the most significant outdoor air pollutant affecting natural ventilation usage. Furthermore, ozone could become increasingly influential on natural ventilation as moving from urban to suburban/rural areas. As to the cooling energy saving considering the impacts of outdoor air pollutants, natural ventilation is estimated to save approximately 10%–40% cooling energy (800–2600 kWh per small commercial building) annually in different location settings of investigated areas across the US. The following economic analysis demonstrates that these electricity savings lead to approximately 80–540 dollars annual savings of building operation cost per building. If the time of use rate is adopted, these cost savings could further increase by approximately 20% (Los Angeles) to more than 50% (Albuquerque) depending on different rate structures, which further demonstrates the potential of adopting natural ventilation as a sustainability measurement with benefits for building owners without compromising occupants health.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ten questions on building stock modeling to inform energy efficiency and sustainability

To enhance economic competitiveness and ensure energy efficiency, resilience, and security, cities and governments are adopting technologies and strategies to improve their existing building stocks. This approach aims to reduce energy use, improve energy affordability, and ensure a reliable power supply while safeguarding occupants during extreme weather events that may disrupt energy services. The effectiveness of these solutions will depend on building stock characteristics, use patterns, weather conditions, evolving technologies and their markets, and a city’s socio-economic conditions. This paper presents ten questions and answers that highlight the most important issues regarding the use of building stock modeling as a powerful tool to provide insights for informing stakeholders’ actions and decision-making on energy efficiency, costs reduction, and resilience of buildings in cities. Building stock modeling should build upon the fit-for-purpose framework, balancing the use case accuracy requirements, level of complexity, and needed resources (expertise, compute). The advancements in Artificial Intelligence (AI), the increasingly available open dataset of building stock in cities, and the more affordable powerful computing will accelerate the adoption of building stock modeling across scales by researchers and practitioners to inform decision making on sustainability and efficiency.

AI↗

Relating storm-snow avalanche instabilities to data collected from the Differential Emissivity Imaging Disdrometer (DEID)

Storm-snow avalanches are challenging to forecast due to complex alpine terrain and during rapidly changing weather conditions. They can result in loss of lives and significant economic impact. We describe how a new device that continuously measures with high-frequency snowflake mass, size, density, and type, the Differential Emissivity Imaging Disdrometer (DEID), and show how the DEID can be used to aid avalanche forecasting when coupled with a storm-snow stability model. DEID measurements of snow accumulation, snow water equivalent (SWE), and snow density obtained during seventeen storms taken at the mid-Collins Snow-Study Plot at Alta Ski Area in Utah's Central Wasatch mountain range during winter 2020–2021 show excellent agreement with infrequent manual measurements. Additionally, two new variables, the Shape Density Index (SDI) and Complexity, are proposed and used to classify snowflake habit and estimate storm-snow shear strength. We illustrate how these DEID-derived data can be used to identify layers of concern in the storm snow such as density inversions, in real-time without digging snow pits. Furthermore, the DEID-data are used to run four variations of the SNOw Slope Stability model (SNOSS) for the storms investigated. The results are evaluated with data collected from tilt-board tests, infrasound measurements, and visual observations of avalanches. For a total fourteen storms analyzed, the DEID-driven SNOSS-modeled minimum stability index predicts the general stability of the storm-snow as indicated by observed avalanches, both natural and of unknown cause. Finally, the results provide a promising approach for nowcasting instabilities within storm-snow layers with a single instrument.

54 ENVIRONMENTAL SCIENCES↗

The good, the bad, and the ugly: Data-driven load profile discord identification in a large building portfolio

Reducing the overall energy consumption and associated greenhouse gas emissions in the building sector is essential for meeting our future sustainability goals. Recently, smart energy metering facilities have been deployed to enable monitoring of energy consumption data with hourly or subhourly temporal resolution. This unprecedented data collection has created various opportunities for advanced data analytics involving load profiles (e.g., building energy benchmarking programs, building-to-grid integration, and calibration of urban-scale energy models). These applications often need preprocessing steps to detect daily load profile discords, such as: 1) outliers due to system malfunctions (the bad) and 2) irregular energy consumption patterns, such as those resulting from holidays (the ugly) compared to normal consumption patterns (the good). However, current preprocessing methods predominantly focus on filtering using statistical threshold values, which fail to capture the contextual discords of daily profiles. In addition, discord detection algorithms in building research are often aimed at finding individual building-level discords, which are not suitable at a large scale. Thus, here, we develop a method for automated load profile discord identification (ALDI) in a large portfolio of buildings (more than 100 buildings). Specifically, ALDI 1) uses the matrix profile (MP) method to quantify the similarities of daily subsequences in time series meter data, 2) compares daily MP values with typical-day MP distributions using the Kolmogorov-Smirnov test, and 3) identifies daily load profile discords in a large building portfolio. We evaluate ALDI using the metering data of both an academic campus and a residential neighborhood. Our results demonstrate that ALDI efficiently discovers measurement errors by system malfunctions and low energy consumption days in the academic campus portfolio, and it detects unique load shape patterns likely driven by occupant behavior and extreme weather conditions in the residential neighborhood.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Active learning strategy for high fidelity short-term data-driven building energy forecasting

The quality of a data-driven model is heavily dependent on the quality of data. Data from building operation often have data bias problems, which means that the data sample is collected in a way that some members of the intended data population are less likely to be included than others. Data-driven energy forecasting models built on such data hence are biased and could lead to large forecasting errors. Active learning—an effective method to defying data bias—is rarely studied or applied in the area of data-driven building energy forecasting modeling. This paper attempts to fill this gap and explores the application of active learning in data-driven building energy forecasting. The developed strategy in this paper efficiently generate informative training data within a time budget and uses block design to passively consider weather disturbances. The developed active learning strategy is applied and evaluated in both virtual and real-building testbeds against traditional data-driven methods. Via these virtual and real-building evaluation cases, we have demonstrated that the data bias problem typically exists in building operation data is resolved by applying the developed active learning strategy. Furthermore, building energy forecasting models trained from data generated from the active learning strategy have shown improved performances in both model accuracy and model extendibility perspectives. The effectiveness of the block design module is also validated to effectively consider the impact of weather conditions on active learning design.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Experimental test of model predictive control in a variable air volume system

Model predictive control (MPC) has been widely studied as a promising approach for improving energy efficiency and operational flexibility in buildings, yet its real-world performance for commercial variable air volume (VAV) systems remains insufficiently characterized. In particular, the impacts of model mismatch on control robustness, real-time computational burden, and device-level operation are rarely evaluated using long-term field data. Here, this study presents a comprehensive experimental evaluation of MPC applied to a full-scale VAV system in Oak Ridge National Laboratory’s Flexible Research Platform-2 building with constant cooling/heating temperature setpoints and no occupancy. The study offers three key advantages over existing work: (1) it uses a representative building in a full-scale experimental test, capturing realistic system dynamics and complexity; (2) it evaluates a relatively sophisticated MPC formulation using two different optimization solvers (Gurobi and PSO), fully accounting for computational complexity and methodological diversity; and (3) it systematically assesses potential negative impacts on various building devices, benchmark against a well-established baseline, ASHRAE Guideline 36 (G36). To isolate zone- and air-handling-unit–level supervisory control effects, the supply fan was operated with a fixed static pressure setpoint under all strategies, and the trim-and-response static pressure reset in G36 was not enabled. Results show that MPC maintained thermal comfort while improving energy efficiency. Abrupt solar radiation variations degraded performance. Computation times ranged from ∼1 s (Gurobi) to ∼ 70 s (PSO). Compared with G36, MPC achieves 33% energy savings and reduces median reheat coil output by approximately a factor of 5–10 for a representative cooling day under matched weather conditions. However, it increases the maximum discomfort deviation from 0.5 to 1°C and results in a 32% increase in staging frequency. In addition, PSO-based MPC introduced damper oscillations, also affecting actuator longevity.

ASHRAE guideline 36↗

Machine learning-enhanced hybrid modeling approach for better identification of a building thermal network model and improved prediction

The gray-box modeling approach, which uses a semi-physical thermal network model, has been widely used in building prediction applications, such as model predictive control (MPC). However, unmeasured disturbances, such as occupants, lighting, and in/exfiltration loads, make it challenging to apply this approach to practical buildings. In this word, we propose a hybrid modeling approach that integrates the gray-box model with a model for unmeasured disturbance. After reviewing several system identification approaches, we systematically designed the unmeasured disturbance model with a model selection process based on statistical tests to make it robust. We generated data based on the building model calibrated by real operational data and then trained the hybrid model for two different weather conditions. The hybrid model approach demonstrates an RMSE reduction of approximately 0.2–0.9 °C and 0.3–2 °C on 1-day ahead temperature prediction compared to the Conventional approach for mild (Berkeley, CA) and cold (Chicago, IL) climates, respectively. In addition, this approach was applied to experimental data obtained from the laboratory building to be used for the MPC application, showing superior prediction performances.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A practical control strategy for demand flexibility with ensured occupant comfort in grid-interactive efficient buildings

This study proposes a practical and simplified demand response (DR) control strategy from the perspective of grid-interactive efficient buildings (GEBs), aiming to secure demand flexibility while ensuring occupant thermal comfort. Focusing on summer on-peak periods, a linear demand response (LDR) strategy that integrates cooling setpoint adjustment and lighting dimming was designed, and its performance was quantitatively evaluated. A case study was conducted using EnergyPlus-based simulations for a U.S. DOE small office prototype building under summer on-peak weather conditions. Compared with a conventional rapid demand response (RDR) strategy, the proposed LDR approach gradually reduced electrical loads while maintaining occupant thermal comfort indices, including predicted mean vote (PMV) and predicted percentage of dissatisfied (PPD), within acceptable comfort ranges. Quantitative analysis of demand flexibility using the grid-interactive impact index (GII) and the flexibility strength index (FSI) showed that the LDR strategy provided approximately 12.5% demand flexibility during DR periods and achieved an electricity cost reduction of about 8.8%. In addition, the results of the part-load ratio (PLR)-based cooling system performance analysis showed that, in the on-peak period, the LDR strategy exhibited improved cooling performance compared with the baseline. Overall, this study shows the potential of a practical DR control strategy that can simultaneously achieve occupant comfort and demand flexibility without relying on complex advanced control technologies.

Jung, Dong Eun↗

An interregional optimization approach for time series aggregation in continent-scale electricity system models

Modeling electric power systems with high shares of weather-dependent resources requires tradeoffs between temporal, spatial, and operational resolution. Many studies perform time series aggregation using clustering algorithms to reduce the temporal dimension, but when modeling continent-scale electricity systems that are large enough to contain multiple independent weather systems, this approach requires large numbers of representative periods to minimize errors in regional wind and solar capacity factors. Here, a new optimization-based approach for representative period selection and weighting is introduced that minimizes regional errors in average renewable capacity factors and electricity demand. The method delivers higher regional fidelity with fewer representative periods than alternative clustering methods when applied to wind, solar, and demand profiles for the contiguous United States. When representative periods are selected from multiple weather years, the optimized method reproduces regional averages with lower error than a complete 365-day time series from any single weather year. The method identifies only representative (as opposed to outlying) periods but can be combined with an iterative "stress period" identification approach to guide efficient decision-making considering both average and high-risk weather conditions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatiotemporal features of traffic help reduce automatic accident detection time

Quick and reliable automatic detection of traffic accidents is of paramount importance to save human lives in transportation systems. However, automatically detecting when accidents occur has proven challenging, and minimizing the time to detect accidents (TTDA) by using traditional features in machine learning (ML) classifiers has plateaued. We hypothesize that accidents affect traffic farther from the accident location than previously reported. Therefore, leveraging traffic signatures from neighboring sensors that are adjacent to accidents should help improve their detection. We confirm this hypothesis by using verified ground-truth accident data, traffic data from radar detection system sensors, and light and weather conditions and show that we can minimize the TTDA while maximizing classification performance by considering spatiotemporal features of traffic. Specifically, we compare the performance of different ML classifiers (i.e, logistic regression, random forest, and XGBoost) when controlling for different numbers of neighboring sensors and TTDA horizons. We use data from interstates 75 and 24 in the metropolitan area that surrounds Chattanooga, TN. Our results show that the XGBoost classifier produces the best results by detecting accidents as quickly as 1.0 min after their occurrence with an area under the receiver operating characteristic curve of up to 83% and an average precision of up to 49%. We describe limitations, open challenges, and how the proposed framework can be used for quicker operational accident detection.

33 ADVANCED PROPULSION SYSTEMS↗

Optimal design of solar-driven electrolytic hydrogen production systems within electricity markets

Hydrogen has the potential to be a key contributor toward a low-carbon economy. Generating hydrogen by electrolysis using renewable energy is one way to support a decarbonized economy; however, its cost is not typically competitive with the carbon-emitting incumbent technology, steam methane reforming. The ability of electrolysis to integrate with electricity markets presents a unique cost reduction opportunity due to the perceived future availability of low and zero-marginal cost renewable energy sources. Additionally, as renewables, and particularly, photovoltaics are installed on the grid, they have a value deflation effect. This work evaluates solar-electrolysis configurations using a mathematical programming framework to maximize system net present value. The framework has been tested with specific weather conditions and financial mechanisms in California. Our findings indicate that a spectrum of potential cost competitive solutions is available for systems that (i) have market configurations resembling hybrid retail/wholesale, resulting in a hydrogen production cost range of US$6.2 kg-1–US$6.6 kg-1, or full wholesale market participation, reducing production cost to US$2.6 kg-1–US$3.1 kg-1, and (ii) achieve projected future cost reductions.

08 HYDROGEN↗