Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind generator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Microprocessor control of a wind turbine generator

This paper describes a microprocessor based system used to control the unattended operation of a wind turbine generator. The turbine and its microcomputer system are fully described with special emphasis on the wide variety of tasks performed by the microprocessor for the safe and efficient operation of the turbine. The flexibility, cost and reliability of the microprocessor were major factors in its selection.

Gnecco, A. J.↗

Conceptual design of a fixed-pitch wind turbine generator system rated at 400 kilowatts

The design and cost aspects of a fixed pitch, 400 kW Wind Turbine Generator (WTG) concept are presented. Improvements in reliability and cost reductions were achieved with fixed pitch operation and by incorporating recent advances in WTG technology. The specifications for this WTG concept were as follows: (1) A fixed pitch, continuous wooden rotor was to be provided by the Gougeon Bros. Co. (2) An 8 leg hyperboloid tower that showed promise as a low cost structure was to be used. (3) Only commercially available components and parts that could be easily fabricated were to be considered. (4) Design features deemed desirable based on recent NASA research efforts were to be incorporated. Detailed costs and weight estimates were prepared for the second machine and a wind farm of 12 WTG's. The calculated cost of energy for the fixed pitch, twelve unit windfarm is 11.5 cents/kW hr not including the cost of land and access roads. The study shows feasibility of fixed pitch, intermediate power WTG operation.

Pintz, A.↗

MOD-0A 200 kW wind turbine generator design and analysis report

The design, analysis, and initial performance of the MOD-OA 200 kW wind turbine generator at Clayton, NM is documented. The MOD-OA was designed and built to obtain operation and performance data and experience in utility environments. The project requirements, approach, system description, design requirements, design, analysis, system tests, installation, safety considerations, failure modes and effects analysis, data acquisition, and initial performance for the wind turbine are discussed. The design and analysis of the rotor, drive train, nacelle equipment, yaw drive mechanism and brake, tower, foundation, electricl system, and control systems are presented. The rotor includes the blades, hub, and pitch change mechanism. The drive train includes the low speed shaft, speed increaser, high speed shaft, and rotor brake. The electrical system includes the generator, switchgear, transformer, and utility connection. The control systems are the blade pitch, yaw, and generator control, and the safety system. Manual, automatic, and remote control are discussed. Systems analyses on dynamic loads and fatigue are presented.

Anderson, T. S.↗

Model-OA wind turbine generator - Failure modes and effects analysis

The results failure modes and effects analysis (FMEA) conducted for wind-turbine generators are presented. The FMEA was performed for the functional modes of each system, subsystem, or component. The single-point failures were eliminated for most of the systems. The blade system was the only exception. The qualitative probability of a blade separating was estimated at level D-remote. Many changes were made to the hardware as a result of this analysis. The most significant change was the addition of the safety system. Operational experience and need to improve machine availability have resulted in subsequent changes to the various systems, which are also reflected in this FMEA.

Klein, William E.↗

Sound measurements and observations of the MOD-OA wind turbine generator

Sound measurements are reported for a wind velocity of about 5 m/s and a power output of about 70 kW. Both broadband and narrowband data were obtained for a range of distances and azimuth angles from the machine. Both discrete frequency and broadband components were identified. Loading harmonics at multiples of the blade passage frequency and electrical generator harmonics at multiples of the shaft speed dominated the spectrum below 100 Hz. The 10,000 Hz peak is believed to be of mechanical origin in the nacelle and the other arises from blade aerodynamic sources. Aural detection distances of about 525 m upwind and 850 downwind were observed.

Shepherd, K. P.↗

Measured effects of wind turbine generation at the Block Island Power Company

Data measurements made on the NASA MOD-OA 200-kw wind-turbine generator (WTG) installed on a utility grid form the basis for an overall performance analysis. Fuel displacement/-savings, dynamic interactions, and WTG excitation (reactive-power) control effects are studied. Continuous recording of a large number of electrical and mechanical variables on FM magnetic tape permit evaluation and correlation of phenomena over a bandwidth of at least 20 Hz. Because the wind-power penetration reached peaks of 60 percent, the impact of wind fluctuation and wind-turbine/diesel-utility interaction is evaluated in a worst-case scenario. The speed-governor dynamics of the diesel units exhibited an underdamped response, and the utility operation procedures were not altered to optimize overall WTG/utility performance. Primary findings over the data collection period are: a calculated 6.7-percent reduction in fuel consumption while generating 11 percent of the total electrical energy; acceptable system voltage and frequency fluctuations with WTG connected; and applicability of WTG excitation schemes using voltage, power, or VARS as the controlled variable.

Wilreker, V. F.↗

Wind Turbine Generator Reliability Analysis to Reduce Operations and Maintenance (O&M) Costs

Wind turbine major systems (blades, pitch, main bearing, gearbox, and generator) are integrated into a composite system. Specifications for these systems and components are developed to achieve symmetry of operation, avoiding negative interaction. For instance, the main bearing, gearbox, and generator (drivetrain) components are interdependent, functioning in unison for efficient energy production. Hence, wind resource and grid interactions affecting the drivetrain impact the performance and reliability of the turbine generator. This paper discusses generator reliability covering the technology evolution over the last 20 years. EPRI's Wind Network for Enhanced Reliability (WinNER) web-based tool and Shermco Industries databases are presented, and conclusions are drawn regarding failures specific to generator design, manufacturing, and operating conditions. Additionally, this paper compares the life expectancy of stator-fed configurations and doubly fed generator systems.

17 WIND ENERGY↗

Control system design for the MOD-5A 7.3 mW wind turbine generator

This paper provides descriptions of the requirements analysis, hardware development and software development phases of the Control System design for the MOD-5A 7.3 mW Wind Turbine Generator. The system, designed by General Electric Company, Advanced Energy Programs Department, under contract DEN 3-153 with NASA Lewis Research Center and DOE, provides real time regulation of rotor speed by control of both generator torque and rotor torque. A variable speed generator system is used to provide both airgap torque control and reactive power control. The wind rotor is designed with segmented ailerons which are positioned to control blade torque. The central component of the control system, selected early in the design process, is a programmable controller used for sequencing, alarm monitoring, communication, and real time control. Development of requirements for use of aileron controlled blades and a variable speed generator required an analytical simulation that combined drivetrain, tower and blade elastic modes with wind disturbances and control behavior. An orderly two phase plan was used for controller software development. A microcomputer based turbine simulator was used to facilitate hardware and software integration and test.

Barton, Robert S.↗

Rotor dynamic considerations for large wind power generator systems

Successful large, reliable, low maintenance wind turbines must be designed with full consideration for minimizing dynamic response to aerodynamic, inertial, and gravitational forces. Much of existing helicopter rotor technology is applicable to this problem. Compared with helicopter rotors, large wind turbines are likely to be relatively less flexible with higher dimensionless natural frequencies. For very large wind turbines, low power output per unit weight and stresses due to gravitational forces are limiting factors. The need to reduce rotor complexity to a minimum favors the use of cantilevered (hingeless) rotor configurations where stresses are relieved by elastic deformations.

Ormiston, R. A.↗

Repurposing Offshore Oil and Gas Platforms to Support Wind Power Generation

B. Gibbs, J. McAvoy, S. T. Nutakki and R. Seetharam, "Repurposing Offshore Oil and Gas Platforms to Support Wind Power Generation," 2025 IEEE International Communications Energy Conference (INTELEC), Houstin, TX, USA, 2025, pp. 215-221, doi: 10.1109/INTELEC63987.2025.11214768.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparison of measured and calculated sound pressure levels around a large horizontal axis wind turbine generator

Results are reported from a large number of simultaneous acoustic measurements around a large horizontal axis downwind configuration wind turbine generator. In addition, comparisons are made between measurements and calculations of both the discrete frequency rotational harmonics and the broad band noise components. Sound pressure time histories and noise radiation patterns as well as narrow band and broadband noise spectra are presented for a range of operating conditions. The data are useful for purposes of environmental impact assessment.

Shepherd, Kevin P.↗

Mod-1 wind turbine generator analysis and design report, volume 1

The activities leading to the completion of detail design of the MOD-1 wind turbine generator are described. Emphasis is placed on the description of the design as it finally evolved. However, the steps through which the design progressed are also traced in order to understand the major design decisions.

Source record↗

MOD-5A wind turbine generator program design report: Volume 1: Executive Summary

The design, development and analysis of the 7.3 MW MOD-5A wind turbine generator covering work performed between July 1980 and June 1984 is discussed. The report is divided into four volumes: Volume 1 summarizes the entire MOD-5A program, Volume 2 discusses the conceptual and preliminary design phases, Volume 3 describes the final design of the MOD-5A, and Volume 4 contains the drawings and specifications developed for the final design. Volume 1, the Executive Summary, summarizes all phases of the MOD-5A program. The performance and cost of energy generated by the MOD-5A are presented. Each subsystem - the rotor, drivetrain, nacelle, tower and foundation, power generation, and control and instrumentation subsystems - is described briefly. The early phases of the MOD-5A program, during which the design was analyzed and optimized, and new technologies and materials were developed, are discussed. Manufacturing, quality assurance, and safety plans are presented. The volume concludes with an index of volumes 2 and 3.

Source record↗

Resource and Load Compatibility Assessment of Wind Energy Offshore of Humboldt County, California

Floating offshore wind is being considered in northern California as indicated by the Bureau of Ocean Energy Management’s issuance of a lease consideration in the Humboldt Call Area. Humboldt County offers access to this enormous resource, but local electric load and transmission are limited. The potential impacts of offshore wind generators at three different scales were studied using a regional grid model of Humboldt County. Offshore wind generation was calculated using modeled wind speed data and 12-MW turbine specifications and integrated with projected load and historical generation. Offshore wind farms deployed in the Humboldt Call Area achieve annual capacity factors between 45% and 54% after losses and maintenance. Power output is variable between and within seasons, with full power output 30% of the time and no output approximately 20% of the time. Electricity from a 48-MW wind farm provides 22% of regional load with limited exports. A 144-MW wind farm serves 38% of local load, exporting 40% of its electricity with the extant 70-MW transmission capacity. A full build-out of 1836 MW would result in 88% curtailment with existing transmission. Across scenarios, offshore wind variability necessitates reliance on existing power plants to meet local demand in periods of low wind.

17 WIND ENERGY↗

Capturing convection essential for projections of climate change in African dust emission

The summertime Sahara and Sahel are the world’s largest source of airborne mineral dust. Cold-pool outflows from moist convection (‘haboobs’) are a dominant source of summertime uplift but are essentially missing in global models, raising major questions on the reliability of climate projections of dust and dust impacts. Here we use convection-permitting simulations of pan-African climate change, which explicitly capture haboobs, to investigate whether this key limitation of global models affects projections. We show that explicit convection is key to capturing the observed summertime maximum of dust-generating winds, which is missed with parameterised convection. Despite this, future climate changes in dust-generating winds are more sensitive to the effects of explicit convection on the wider meteorology than they are to the haboobs themselves, with model differences in the change in dust-generating winds reaching 60% of current values. The results therefore show the importance of improving convection in climate models for dust projections.

54 ENVIRONMENTAL SCIENCES↗

Wind turbine generator interaction with conventional diesel generators on Block Island, Rhode Island. Volume 1: Executive summary

Primary results are summarized for a three-part study involving the effects of connecting a MOD-OA wind turbine generator to an isolated diesel power system. The MOD-OA installation considered was the third of four experimental nominal 200 kW wind turbines connected to various utilities under the Federal Wind Energy Program and was characterized by the highest wind energy penetration levels of four sites. The study analyses address: fuel displacement, dynamic interaction, and three modes of reactive power control. These analyses all have as their basis the results of the data acquisition program conducted on Block Island, Rhode Island.

Wilreker, V. F.↗