Search NASA⌕ Search

SEARCH · Search NASA

Results for “wind turbine controls”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

New vortex‐lift and tangential‐force models for HAWT aerodynamic load prediction

Abstract Horizontal axis wind turbines (HAWTs) experience three‐dimensional rotational and unsteady aerodynamic phenomena at the rotor blades sections. These highly unsteady three‐dimensional effects have a dramatic impact on the aerodynamic load distributions on the blades, in particular, when they occur at high angles of attack due to stall delay and dynamic stall. Unfortunately, there is no complete understanding of the flow physics yet at these unsteady 3D flow conditions, and hence, the existing published theoretical models are often incapable of modelling the impact on the turbine response realistically. The purpose of this paper is to provide an insight on the combined influence of the stall delay and dynamic stall on the blade load history of wind turbines in controlled and uncontrolled conditions. New dynamic stall vortex and nonlinear tangential force coefficient modules, which integrally take into account the three dimensional rotational effect, are also proposed in this paper. This module along with the unsteady influence of turbulent wind speed and tower shadow is implemented in a blade element momentum (BEM) model to estimate the aerodynamic loads on a rotating blade more accurately. This work presents an important step to help modelling the combined influence of the stall delay and dynamic stall on the load history of the rotating wind turbine blades which is vital to have lighter turbine blades and improved wind turbine design systems.

Elgammi, Moutaz↗

Employing static excitation control and tie line reactance to stabilize wind turbine generators

An analytical representation of a wind turbine generator is presented which employs blade pitch angle feedback control. A mathematical model was formulated. With the functioning MOD-0 wind turbine serving as a practical case study, results of computer simulations of the model as applied to the problem of dynamic stability at rated load are also presented. The effect of the tower shadow was included in the input to the system. Different configurations of the drive train, and optimal values of the tie line reactance were used in the simulations. Computer results revealed that a static excitation control system coupled with optimal values of the tie line reactance would effectively reduce oscillations of the power output, without the use of a slip clutch.

Hwang, H. H.↗

Control design and performance analysis of a 6 MW wind turbine-generator

This paper discusses an approach to the modeling and performance for the preliminary design phase of a large (6.2 MW) horizontal axis wind turbine generator (WTG). Two control philosophies are presented, both of which are based on linearized models of the WT mechanical and electrical systems. The control designs are compared by showing the performance through detailed non-linear time simulation. The disturbances considered are wind gusts, and electrical faults near the WT terminals.

Murdoch, A.↗

2020 Component Innovation Awardee: Windurance LLC

Currently, there is no wind system power-conversion component available to wind turbine OEMs that is certified to applicable standards for use in the U.S. distributed wind energy market. Off-the-shelf industrial drives have features that are not needed by distributed wind OEMs and lack other features that would be valuable for the operation and control of wind turbine generating systems. In addition to adding costs for OEMs, these industrial drives increase uncertainty and risk for project developers and prospective owners. All of this presents barriers and increases costs for the development of distributed wind in the United States. With funding from CIP, Windurance plans to develop an industry-specific power-conversion component that will offer application-specific features at lower cost for distributed wind OEMs.

CIP↗

Robust Output Feedback Control Design for Inertia Emulation by Wind Turbine Generators

Wind generation has gained widespread use as a renewable energy source. Most wind turbines and other renewables connected to the grid through converters result in a reduction in the natural inertial response to grid frequency changes. The doubly-fed induction generator (DFIG) can be controlled to compensate for this reduction and, in fact, provide faster response than traditional synchronous machines. This paper proposes to design observer based output feedback linear quadratic regulator (LQR) and H control laws to realize the inertia emulation function and deliver fast frequency support. Furthermore, the aim is to track the reference speed by a diesel synchronous generator (DSG) in order to reach the desired inertia. The control signal is computed based on a reduced order model using the balanced truncation technique. A comparison with selective modal analysis (SMA) and balanced truncation model reduction techniques is presented. Comprehensive results show the effective emulation of synthetic inertia by implementing the control laws on a nonlinear three- phase diesel-wind system. The proposed technique is analyzed for different short circuit ratio (SCR) scenarios.

17 WIND ENERGY↗

Curled-Skewed Wakes behind Yawed Wind Turbines Subject to Veered Inflow

This work presents a new engineering analytical model that predicts the effect of both the turbine yaw misalignment and the inflow wind veer on the wake flow distribution downwind of a wind turbine. To consider the veered inflow, two methods were examined. In the first method, the curled shape of the wake due to the yaw offset is initially modelled. The wake shape is then laterally skewed at each height due to the wind veer based on the assumption that the turbine wake is transported downstream by the incoming flow. The second method is a more realistic approach that accounts for the effect of wind veer on the wind velocity direction and the yaw angle seen by the wind turbine. This models the wake region in a local coordinate system defined based on the wind direction at each height. A coordinate transformation is then performed to represent the wake flow distribution in the global coordinate system attached to the ground. The results show that while the two methods provide similar outputs for small variations in the wind direction across the rotor, the difference becomes more evident with an increase in wind veer. High-fidelity simulations for a turbine subject to a neutral atmospheric boundary layer were employed to validate model predictions for different operating conditions.

17 WIND ENERGY↗

Wind farm flow control: prospects and challenges

Abstract. Wind farm control has been a topic of research for more than two decades. It has been identified as a core component of grand challenges in wind energy science to support accelerated wind energy deployment and to transition to a clean and sustainable energy system for the 21st century. The prospect of collective control of wind turbines in an array, to increase energy extraction, reduce structural loads, improve the balance of systems, reduce operation and maintenance costs, etc. has inspired many researchers over the years to propose innovative ideas and solutions. However, practical demonstration and commercialization of some of the more advanced concepts has been limited by a wide range of challenges, which include the complex physics of turbulent flows in wind farms and the atmosphere, uncertainties related to predicting structural load and failure statistics, and the highly multi-disciplinary nature of the overall design optimization problem, among others. In the current work, we aim at providing a comprehensive overview of the state of the art and outstanding challenges, thus identifying the key research areas that could further enable commercial uptake and success of wind farm control solutions. To this end, we have structured the discussion on challenges and opportunities into four main areas: (1) insight in control flow physics, (2) algorithms and AI, (3) validation and industry implementation, and (4) integrating control with system design (co-design).

Meyers, Johan (ORCID:0000000228284397)↗

Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL): Use Cases and Definitions

This resource document is designed to establish common use cases and definitions for U.S. Department of Energy national laboratories and partners participating in the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) effort. Use case definitions can be used to classify and connect research-and-development efforts and ultimately to organize project goals. Establishing use cases will also allow for the definition of operational benchmarks for various elements of the MIRACL project and broader distributed wind program as well as enable future alignment with other distributed energy resource research projects.

17 WIND ENERGY↗

Robust trajectory-constrained frequency control for microgrids considering model linearization error

Grid supportive modes integrated within inverter-based resources can improve the frequency response of renewable-rich microgrids. The synthesis of grid supportive modes to guarantee frequency trajectory constraints under a predefined disturbance set is challenging but essential. To tackle this challenge, a numerical optimal control (NOC)-based control synthesis methodology is proposed. Without loss of generality, a wind-diesel fed microgrid is studied, where we aim to design grid supportive functions in the wind turbine. In the control design, linearized models are used, and the linearization-induced errors are quantitatively analyzed by reachability and interval arithmetics and represented in the form of interval uncertainties. Then, the NOC problem can be formulated into a robust mixed-integer linear program. The control structure is strategically configured into two levels to realize online deployment. The proposed control is verified on the modified 33-node microgrid with a full-order three-phase nonlinear model in Simulink. In conclusion, the simulation results show the effectiveness of the proposed control paradigm and the necessity of considering linearization-induced uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Adaptive Control Using Residual Mode Filters Applied to Wind Turbines

Many dynamic systems containing a large number of modes can benefit from adaptive control techniques, which are well suited to applications that have unknown parameters and poorly known operating conditions. In this paper, we focus on a model reference direct adaptive control approach that has been extended to handle adaptive rejection of persistent disturbances. We extend this adaptive control theory to accommodate problematic modal subsystems of a plant that inhibit the adaptive controller by causing the open-loop plant to be non-minimum phase. We will augment the adaptive controller using a Residual Mode Filter (RMF) to compensate for problematic modal subsystems, thereby allowing the system to satisfy the requirements for the adaptive controller to have guaranteed convergence and bounded gains. We apply these theoretical results to design an adaptive collective pitch controller for a high-fidelity simulation of a utility-scale, variable-speed wind turbine that has minimum phase zeros.

Frost, Susan A.↗

Impact of wake steering on loads of downstream wind turbines at an above-rated condition

Wake steering strategies often seek to gain power at the expense of increased fatigue loads. Here, we investigate the feasibility of applying wake steering at an above-rated condition. In such a condition, the farm is operating at rated power, and thus, increased power output is not the goal. Instead, wake steering is considered in the context of load reduction. We perform a sweep of wind directions and yaw misalignment angles, ranging from negative to positive values. This approach allows us to obtain trends and identify asymmetries in turbine response for symmetric scenarios. We use a wind farm consisting of five aligned IEA Wind 15-MW reference wind turbines, and analyze trends related to the blade-root, low-speed shaft, and tower-base moments, both in terms of standard deviation and damage equivalent loads. We show that for any given fixed wind direction, the turbines can be yawed such that the fatigue loads are reduced. Reductions of up to 5% (depending on the component) in terms of standard deviation and damage equivalent loads can be achieved by negatively yawing the turbine. A negative yaw misalignment has shown to be the direction of larger improvements. Such results contrast those found for below-rated conditions, where a positive yaw misalignment is typically preferred. However, since load reduction is not uniform across all component loads, more study and consideration is required before operational recommendations can be made.

17 WIND ENERGY↗

Mod-1 Wind Turbine Generator Analysis

A general summary of the MOD-1 wind turbine generator control system and simulation is presented. Mechanical and speed stabilization control means to add drive train damping were mentioned and MOD-1 simulation results showing the effects of speed stabilization are displayed.

Barton, R. S.↗

Comparative wind tunnel tests at high Reynolds numbers of NACA 64 621 airfoils with two aileron configurations

An experimental program to measure the aerodynamic characteristics of the NACA 64-621 airfoil when equipped with plain ailerons of 0.38 chord and 0.30 chord and with 0.38 chord balanced aileron has been conducted in a pressurized 6 x 12-inch High Reynolds Number Wind Tunnel. Surface pressures were measured and integrated to yield lift and pressure drag coefficients for angles of attack from -3 deg to +42 deg, and for selected aileron deflections from 0 to -90 deg at nominal Mach and Reynolds numbers of 0.25 and 5 x l0 exp 6, respectively. When resolved into thrust coefficient for wind turbine aerodynamic control applications, the data indicated the anticipated decrease in thrust coefficient with negative aileron deflection at low angles of attack; however, as angle of attack increased, thrust coefficients eventually became positive. All aileron configurations, even at -90 deg deflections, showed this trend. Hinge moments for each configuration complete the data set.

Gregorek, G. M.↗

Comparative wind tunnel test at high Reynolds numbers of NACA 64 621 airfoils with two aileron configurations

An experimental program to measure the aerodynamic characteristics of the NACA 64-621 airfoil when equipped with plain ailerons of 0.38 chord and 0.30 chord and with 0.38 chord balanced aileron has been conducted in the pressurized O.S.U. 6 x 12 ft High Reynolds Number Wind Tunnel. Surface pressures were measured and integrated to yield lift and pressure drag coefficients for angles of attack from -3 to +42 deg and for selected aileron deflections from 0 to -90 deg at nominal Mach and Reynolds numbers of 0.25 and 5 x 10(exp 6). When resolved into thrust coefficient for wind turbine aerodynamic control applications, the data indicated the anticipated decrease in thrust coefficient with negative aileron deflection at low angles of attack; however, as angle of attack increased, thrust coefficients eventually became positive. All aileron configurations, even at -90 deg deflections showed this trend. Hinge moments for each configuration complete the data set.

Gregorek, G. M.↗

Control system design for the MOD-5A 7.3 mW wind turbine generator

This paper provides descriptions of the requirements analysis, hardware development and software development phases of the Control System design for the MOD-5A 7.3 mW Wind Turbine Generator. The system, designed by General Electric Company, Advanced Energy Programs Department, under contract DEN 3-153 with NASA Lewis Research Center and DOE, provides real time regulation of rotor speed by control of both generator torque and rotor torque. A variable speed generator system is used to provide both airgap torque control and reactive power control. The wind rotor is designed with segmented ailerons which are positioned to control blade torque. The central component of the control system, selected early in the design process, is a programmable controller used for sequencing, alarm monitoring, communication, and real time control. Development of requirements for use of aileron controlled blades and a variable speed generator required an analytical simulation that combined drivetrain, tower and blade elastic modes with wind disturbances and control behavior. An orderly two phase plan was used for controller software development. A microcomputer based turbine simulator was used to facilitate hardware and software integration and test.

Barton, Robert S.↗

Comparison of blade loads of fixed and free yawing wind turbine

The self regulating composite bearingless wind turbine utilizes an automatic pitch control concept and a completely unrestrained yawing degree of freedom. Aerodynamic moments caused by skewed flow provide the control to align the wind turbine with the wind. Model tests demonstrated the feasibility of the concept and analytical studies showed the free system to experience lower blade loads compared to the fixed system.

Cheney, M. C.↗

Model-free control for frequency response support in microgrids utilizing wind turbines

Islanded microgrids integrated with renewable energy resources bring additional challenges to the primary frequency control due to their power-electronic interfaced generations. Developing an efficient control strategy for inertia emulation and frequency response support of microgrids is becoming an important issue. Wind turbine dynamics, however, will degrade the emulated inertial and primary responses with most traditional control strategies. On the other hand, compensation methods often require the knowledge of system models at the design stage and state estimation for feedback once deployed online. To overcome these challenges, this paper explores a model-free control (MFC) strategy to emulate the desired inertia and support the frequency response of a diesel-wind microgrid system. Additionally, the proposed MFC strategy utilizes a model reference concept to obtain guaranteed inertial response and improve the frequency response of microgrids. This work considers different control strategies with different operating points. The proposed controller is implemented and verified using the modified 33-bus full nonlinear model of the three-phase diesel-wind system in Simulink. Simulation results demonstrate the improved frequency response by precisely emulating the desired inertia using the MFC strategy.

24 POWER TRANSMISSION AND DISTRIBUTION↗