Search NASA⌕ Search

SEARCH · Search NASA

Results for “zone”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Unique Structural Features Relate to Evolutionary Adaptation of Cytochrome P450 in the Abyssal Zone

Cytochromes P450 (CYPs) form one of the largest enzyme superfamilies, with similar structural folds yet biological functions varying from synthesis of physiologically essential compounds to metabolism of myriad xenobiotics. Sterol 14α-demethylases (CYP51s) represent a very special P450 family, regarded as a possible evolutionary progenitor for all currently existing P450s. In metazoans CYP51 is critical for the biosynthesis of sterols including cholesterol. Here we determined the crystal structures of ligand-free CYP51s from the abyssal fish Coryphaenoides armatus and human-. Comparative sequence–structure–function analysis revealed specific structural elements that imply elevated conformational flexibility, uncovering a molecular basis for faster catalytic rates, lower substrate selectivity, and intrinsic resistance to inhibition. In addition, the C. armatus structure displayed a large-scale repositioning of structural segments that, in vivo, are immersed in the endoplasmic reticulum membrane and border the substrate entrance (the FG arm, >20 Å, and the β4 hairpin, >15 Å). The structural distinction of C. armatus CYP51, which is the first structurally characterized deep sea P450, suggests stronger involvement of the membrane environment in regulation of the enzyme function. We interpret this as a co-adaptation of the membrane protein structure with membrane lipid composition during evolutionary incursion to life in the deep sea.

Biochemistry & Molecular Biology↗

Causal relationships of vegetation productivity with root zone water availability and atmospheric dryness at the catchment scale

Abstract. This study explores the causal relationships between catchment water availability, vapor pressure deficit, and gross primary productivity (GPP) across 341 catchments in the contiguous US. Seasonal climatic, hydrological, and vegetation characteristics were represented using the Horton index, ecological aridity index, evaporative fraction index, and carbon uptake efficiency. Statistical methods, including circularity statistics, correlation analysis, and causality tests, were employed to determine the complex interactions between catchment wetness, atmospheric dryness, and vegetation carbon uptake. The results revealed a maximum lag of 2 months in the intra-annual variability of catchment water supply–productivity and atmospheric water demand–productivity relationships, with hysteresis patterns varying with the catchment's hydrological characteristics. In catchments not permanently under water-limited or energy-limited conditions, vegetation experiences hydrological stress during the peak growing period, coinciding with the highest gross primary productivity and carbon uptake efficiency being out of phase with the Horton index and in phase with the evaporative fraction index. Causality analysis highlights strong temporal continuity in GPP seasonal characteristics, with a cause–effect relationship between catchment water supply, atmospheric demand, and vegetation productivity spanning a maximum of 2 months. These findings underscore the need for a comprehensive functional framework that integrates catchment water supply, atmospheric demand, and vegetation productivity to enhance our understanding and predictive capabilities with regard to ecosystem responses to climate change.

54 ENVIRONMENTAL SCIENCES↗

Fracture Networks Imaging in CO2 Injection Zones in IBDP Site: An Unsupervised Machine Learning Application with Multiple Datasets

This is the conference paper accompanying a poster presentation at the 17th International Conference on Greenhouse Gas Control Technologies GHGT-17 held in Calgary, Canada, October 20-24 , 2024. This work highlights the integration of unsupervised machine learning (ML) techniques as a transformative tool for advancing understanding of CO2 injection into reservoirs that could potentially contribute to optimizing injection strategies and reservoir management, ultimately bolstering the efficacy and sustainability of CO2 storage.

Kumar, Abhash↗

Zoned namespaces for computing device main memory

Disclosed in some examples are methods, systems, memory devices, memory controllers, and machine-readable mediums which provide for reserving physical memory device resources to specific execution units. Execution units may include processes, threads, virtual machines, functions, procedures, or the like. Physical memory device resources may include channels, modules, ranks, banks, bank groups, and the like. For example, a physical memory device resource that is reservable may be a smallest unit that allows for parallel access with another of the same size unit.

Sheridan, Patrick Michael↗

Influence of Phase-Change Materials and Operating Periods on Load Shifting for Thermal Storage Heat Pumps in European Climate Zones

As the reliance on heat pumps (HPs) for space conditioning increases worldwide, ex-tensive grid strains during utility peak hours are expected. Significant research efforts focus on investigating the use of integrated thermal energy storage (TES) systems to reduce peak energy demands. Conventionally, TES systems are often integrated to store and provide either cooling or heating, but not both. In this work, a single room-temperature phase-change material (PCM)-TES was integrated for dual-mode opera-tion with an R290 air-to-water 10.5 kW (3-Ton) HP. Two PCM melting temperatures (17°C, 22°C) were assessed to investigate their impact on system performance and cost reductions for Milan, Italy (4A); Barcelona, Spain (3A); and Oslo, Norway (6A). HP and HP-TES performance maps were generated using Modelica-based transient models and co-simulated with a prototype residential building using the Spawn of En-ergyPlusTM with simple rule-based controls. Our simulations indicate that PCM-17°C provided annual cost savings at higher peak-to-off-peak cost ratios, as the demand re-duction dominated the savings potential. The recharge energy costs and requirements became more dominant at lower cost ratios, making PCM-22°C more beneficial at lower cost ratios. Finally, despite Oslo's heating-dominated climate, the utility peak hours favor cooling demand reductions, making PCM-17°C more appealing. In all cases, the cost savings potential stabilized between 4 – 10% regardless of cost ratio, suggesting that system-level component and operation control optimization is required to maximize cost savings further.

25 ENERGY STORAGE↗

Exploring constituent redistribution in irradiated U-19Pu-14Zr fuel via electron probe microanalysis

Here, the phenomena of constituent redistribution, wherein a previously homogeneous metallic fuel forms discrete, radially concentric compositional zones upon irradiation was investigated by examining an irradiated U-19Pu-14Zr fuel (where numbers represent wt. %) with a burnup of 11.5 at.% with electron probe microanalysis (EPMA) and quadruple inductively coupled plasma mass spectroscopy (Q-ICP-MS). EPMA-generated U, Pu, and Zr compositional data obtained from a diameter traverse of the sample was converted to mass and was used to: 1) compare the overall fuel element analysis results between the two methods, 2) determine the number of compositionally distinct zones forming as a result of constituent redistribution; and 3) quantify the post-irradiation loss or gain of U, Pu, and Zr atoms in each distinct compositional zone. Weight percent concentrations of U, Pu, and Zr for the overall cross section compare favorably between the two analytical methods, suggesting that the spatially resolved EPMA analysis complements bulk chemical analysis. Among the four identified compositional zones, post-irradiation quantification of U, Pu, and Zr elemental atom content changes shows that the quantity of U atoms lost from the innermost zone is slightly less than the quantity of U atoms gained by the middle two zones, and the quantity of Zr atoms lost from the high-U third zone is slightly less than is gained by the two innermost zones. Pu is lost from all four zones, although the innermost zone and the high-U third zone lose a significantly higher percentage (> 22 %) of their initial Pu atoms than the other two zones. For all three elements, EPMA cannot distinguish between atoms lost due to transport to a different zone from atoms lost due to nuclear processes; however, the insight gained from using this process can be used to experiment with new modeling techniques to predict constituent redistribution in U-Pu-Zr fuels.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Slug Test Characterization Results for the Upper Three Runs Aquifer at the Chemicals, Metals, and Pesticides Pits Operable Unit

Slug tests were performed on 21 wells screened within the Upper Three Runs aquifer (UTRA) at the Chemical, Metals, and Pesticide (CMP) Pits Operable Unit (OU) to determine unit-specific hydraulic properties. The UTRA is the water table aquifer at CMP Pits and is comprised of three discrete zones that are separated by two semi-continuous confining zones. These zones include the transmissive zone (TZ, unconfined), the middle aquifer zone (MAZ, semi-confined), and the lower aquifer zone (LAZ, semi-confined). The LAZ, the most substantial portion of the UTRA in the area, extends vertically to the green clay confining zone (GCCZ). A subset of wells from each zone was selected for slug testing. The objective of the project was to determine hydraulic properties of the three zones of the UTRA for use in future updates to the CMP pits groundwater flow and contaminant transport modeling.

54 ENVIRONMENTAL SCIENCES↗

Energy characteristics of multi-chiller load distribution algorithms in a large office building

Here, this study evaluates the energy efficiency of multi-chiller systems in large office buildings, focusing on their optimization across various climate zones as defined by ASHRAE. Using EnergyPlus for simulations, the research examines five different load distribution algorithms in multi-chiller systems that range from one to ten chillers, aiming to understand their effectiveness in 15 distinct climate zones. The primary objectives of the study include identifying the energy efficiency of multi-chiller systems in each climate zone, determining the appropriate number of chillers for each zone, and evaluating the performance of the load distribution algorithms. Based on the U.S. Department of Energy’s commercial building model, the results suggest that multi-chiller systems can significantly reduce cooling energy consumption in various climates. Among the algorithms evaluated, the Sequential Uniform Part Load Ratio (SUPLR) algorithm demonstrates notable efficiency, especially in the 4A climate zone (Baltimore), where it achieves substantial energy savings. Applying the SUPLR algorithm in a multi-chiller setup with four chillers in this zone leads to an estimated 24.5 % reduction in energy usage, equivalent to 183 MW annually. The research indicates that a range of 3 to 5 chillers is typically optimal for most climate zones. In-depth analysis in the 4A climate zone highlights the importance of minimizing operation hours at low Part Load Ratios (PLR) to ensure that chillers operate at a high Coefficient of Performance (COP). This strategy underscores the potential of well-designed multi-chiller systems to reduce cooling energy demand, particularly in climates with transitional seasons. This study provides an overview of the energy-saving potential of multi-chiller systems, applicable across a variety of climatic scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Spatial mapping of the localized corrosion behavior of a magnesium alloy AZ31B tungsten inert gas weld

Sections of a magnesium alloy, AZ31B, joined with tungsten inert gas (TIG) welding, were examined with scanning electrochemical microscopy (SECM) and scanning Kelvin probe force microscopy (SKPFM) to investigate corrosion mechanisms by correlating observed corrosion behavior with weld-affected microstructural variations. Insight into the changing nature of the galvanic couples between weld zones and at localized microgalvanic sites were investigated using SECM and SKPFM to map both electrochemically active regions and Volta potential differences across the weld-affected zones. The formation of an Al-Zn solidification network in the fusion zone (FZ) at and near the TIG weld epicenter differs from the outer heat-affected zone (HAZ), where intermetallic particles (IMPs) are the notable secondary phase from the magnesium matrix. These microstructures were mapped with SKPFM before and after brief exposure to a salt solution, revealing micro-galvanic couples as the main driving force to corrosion initiation and propagation within each zone. The IMPs and Al-Zn solidification network act as strong cathodes and govern the corrosion processes. The galvanic coupling and evolution of the intrinsic corrosion behavior between the weld zones is explained by monitoring the hydrogen evolution reaction (HER) with SECM over time. Anodically induced cathodic activation is confirmed for this welded material, as micro-galvanic couples between microstructural features are found to transition over time to broad electrochemically active areas within the weld-affected zones, resulting in polarity reversal as time of exposure proceeds.

Anodically induced cathodic activation↗