Search NASA⌕ Search

SEARCH · Search NASA

Results for “ACOUSTIC TESTING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Acoustic Results of Over the Rotor and Soft Vane Treatments on the Source Diagnostic Test Model in the NASA Glenn Research Center 9- by 15-foot Low-Speed Wind Tunnel

Two novel fan noise reduction concepts were tested using the Source Diagnostic Test fan stage model in the NASA Glenn 9x15 Low Speed Wind Tunnel. One, referred to as over the rotor treatment, consisted of a number of different casing treatments some of which contained acoustic treatment. The other, known as soft vane, consisted of fan exit guide vanes whose interior volume contained acoustic treatment that was exposed to the vane suction side surface through a perforate.

Aeroacoustics↗

A theoretical and flight test study of pressure fluctuations under a turbulent boundary layer. Part 2: Flight test study

The study of pressure fluctuations under a turbulent boundary layer was undertaken with the objective of extending previous work to lower frequencies. Wind tunnel and flight test measurements are invalid at low frequencies because of extraneous acoustic noises and free stream turbulence. A glider was instrumented and used as a test bed to carry microphones into a smooth flow free of acoustic noise. Hodgson had previously measured the spectrum of boundary layer noise on a glider wing. These tests showed a drop off at low frequencies that could not be reproduced in any other facility. The measurements were made on the forward fuselage of a glider where the boundary layer could develop naturally and have some length in a zero pressure gradient before the measurements were made. Two different sets of measurements were made.

Panton, R. L.↗

Detection and Location of Transverse Matrix Cracks in Cross-Ply Gr/Ep Composites Using Acoustic Emission

Transverse matrix cracking in cross-ply gr/ep laminates was studied with advanced acoustic emission (AE) techniques. The primary goal of this research was to measure the load required to initiate the first transverse matrix crack in cross-ply laminates of different thicknesses. Other methods had been previously used for these measurements including penetrant enhanced radiography, optical microscopy, and audible acoustic microphone measurements. The former methods required that the mechanical test be paused for measurements at load intervals. This slowed the test procedure and did not provide the required resolution in load. With acoustic microphones, acoustic signals from cracks could not be clearly differentiated from other noise sources such as grip damage, specimen slippage, or test machine noise. A second goal for this work was to use the high resolution source location accuracy of the advanced acoustic emission techniques to determine whether the crack initiation site was at the specimen edge or in the interior of the specimen.In this research, advanced AE techniques using broad band sensors, high capture rate digital waveform acquisition, and plate wave propagation based analysis were applied to cross-ply composite coupons with different numbers of 0 and 90 degree plies. Noise signals, believed to be caused by grip damage or specimen slipping, were eliminated based on their plate wave characteristics. Such signals were always located outside the sensor gage length in the gripped region of the specimen. Cracks were confirmed post-test by microscopic analysis of a polished specimen edge, backscatter ultrasonic scans, and in limited cases, by penetrant enhanced radiography. For specimens with three or more 90 degree plies together, there was an exact 1-1 correlation between AE crack signals and observed cracks. The ultrasonic scans and some destructive sectioning analysis showed that the cracks extended across the full width of the specimen. Furthermore, the locations of the cracks from the AE data were in excellent agreement with the locations measured with the microscope. The high resolution source location capability of this technique, combined with an array of sensors, was able to determine that the cracks initiated at the specimen edges, rather than in the interior. For specimens with only one or two 90 degree plies, the crack-like signals were significantly smaller in amplitude and there was not a 1-1 correlation to observed cracks. This was similar to previous results. In this case, however, ultrasonic and destructive sectioning analysis revealed that the cracks did not extend across the specimen. They initiated at the edge, but did not propagate any appreciable distance into the specimen. This explains the much smaller AE signal amplitudes and the difficulty in correlating these signals to actual cracks in this, as well as in the previous study.

Prosser, W. H.↗

Directional Cooling-Induced Fracturing: Directional Cooling Data Under True-Triaxial Stress State

Data includes Directional Cooling-Induced Fracturing (DCIF) testing data using westerly granite blocks. This submission includes data from two samples of westerly granite, lab sample 7 and 8. Files contain stress, temperature and acoustic emission data acquired during polyaxial, laboratory testing of westerly granite blocks for each sample. FILES: .tradb -- files containing acoustic emission waveforms; sqlite3 database .pridb -- files containing basic acoustic emission information (no waveforms); sqlite3 database .geom -- geometry of the AE sensor network (ASCII)

15 GEOTHERMAL ENERGY↗

Commercialization and Industrial Development for the Fetal Hear Rate Monitor

The primary objectives for this task were to continue the development and testing of the NASA/ODU passive acoustic fetal heart rate monitor, with the goal of transferring the technology to the commercial sector. Areas of work included: 1. To assist in the development of a new hardware front end electronics box for the fetal heart rate monitor, so as to reduce the size of the electronics box, and also to provide for a "low-frequency" and "high-frequency" mode of operation. To make necessary changes in the operating software to support the two modes of operation. 2. To provide an option for a strip chart recording for the system, so that medical personnel could more easily make comparisons with ultra sound strip chart recordings. and 3. To help with continued testing of the system.

Zahorian, Stephen↗

Acoustic Data Processing and Transient Signal Analysis for the Hybrid Wing Body 14- by 22-Foot Subsonic Wind Tunnel Test

An advanced vehicle concept, the HWB N2A-EXTE aircraft design, was tested in NASA Langley's 14- by 22-Foot Subsonic Wind Tunnel to study its acoustic characteristics for var- ious propulsion system installation and airframe con gurations. A signi cant upgrade to existing data processing systems was implemented, with a focus on portability and a re- duction in turnaround time. These requirements were met by updating codes originally written for a cluster environment and transferring them to a local workstation while en- abling GPU computing. Post-test, additional processing of the time series was required to remove transient hydrodynamic gusts from some of the microphone time series. A novel automated procedure was developed to analyze and reject contaminated blocks of data, under the assumption that the desired acoustic signal of interest was a band-limited sta- tionary random process, and of lower variance than the hydrodynamic contamination. The procedure is shown to successfully identify and remove contaminated blocks of data and retain the desired acoustic signal. Additional corrections to the data, mainly background subtraction, shear layer refraction calculations, atmospheric attenuation and microphone directivity corrections, were all necessary for initial analysis and noise assessments. These were implemented for the post-processing of spectral data, and are shown to behave as expected.

Bahr, Christopher J.↗

Experimental study correlating damage and permeability in concrete using confined, flattened Brazilian disks

This research experimentally studies coupled hydro-mechanical relationships using flattened Brazilian disks under confinement, with concurrent permeability measurements and acoustic emission monitoring. A series of tests are performed on concrete, as representative samples of brittle geo-materials, under a range of confining stresses between 2.76 and 13.79 MPa. Acoustic emission data is used to quantify damage and identify damage thresholds. Damage is then correlated to pre-peak changes in permeability. The advancement of models that couple transport properties to mechanical responses are of interest in the fields of carbon sequestration, hydrofracking, production of geothermal energy, induced seismicity, and underground nuclear waste storage, and these experiments validate a novel experimental approach towards investigating hydro-mechanical relationships.

Boyce, S.↗

Installation caused flow distortion and its effect on noise from a fan designed for turbofan engines

A ground test stand was used to obtain acoustic data on a full scale prototype fan designed for quiet subsonic aircraft engines. The fan was installed in three different ways in the test stand. In two of the installations the fan was driven by a shaft in the inlet; in the third installation the fan was driven from the rear. These three installations, and the structures associated with them, resulted in various amounts of inlet flow distortion to the fan. The rear drive installation had less inlet flow distortion than the two front drive installations. Some measurements of inlet flow distortion were made and used in a blade passage noise generation theory to predict the effects of distortion on noise. Good agreement was obtained when the predicted and measured power level differences between the front drive and rear drive installations were compared.

Povinelli, F. P.↗

Investigation of noise suppression by sonic inlets for turbofan engines. Volume 1: Program summary

Results of a program for sonic inlet technology development are presented. This program includes configuration and mechanical design selection of concepts, aerodynamic design description of the models, and results of test evaluation. Several sonic inlet concepts were tested and compared for aerodynamic and acoustic performance. Results of these comparative evaluations are presented. Near-field measurements were taken inside several of the inlet models. Results of these tests are discussed with respect to the effect of Mach number gradients on noise attenuation and rotor shock wave attenuation, and boundary layer effects on noise propagation. The test facilities and experimental techniques employed are described briefly.

Klujber, F.↗

Static and wind tunnel model tests for the development of externally blown flap noise reduction techniques

Externally blown flap models were tested for noise and performance at one-fifth scale in a static facility and at one-tenth scale in a large acoustically-treated wind tunnel. The static tests covered two flap designs, conical and ejector nozzles, third-flap noise-reduction treatments, internal blowing, and flap/nozzle geometry variations. The wind tunnel variables were triple-slotted or single-slotted flaps, sweep angle, and solid or perforated third flap. The static test program showed the following noise reductions at takeoff: 1.5 PNdB due to treating the third flap; 0.5 PNdB due to blowing from the third flap; 6 PNdB at flyover and 4.5 PNdB in the critical sideline plane (30 deg elevation) due to installation of the ejector nozzle. The wind tunnel program showed a reduction of 2 PNdB in the sideline plane due to a forward speed of 43.8 m/s (85 kn). The best combination of noise reduction concepts reduced the sideline noise of the reference aircraft at constant field length by 4 PNdB.

Pennock, A. P.↗

Results of an investigation of the acoustic and vibrational environment of a full scale space shuttle orbiter structural test panel with simulated TPS in the Ames unitary plan wind tunnel, model 81-0, test OS8A and B

Results of tests OS8A and B and pertinent test and model information are presented. The test was conducted in two parts. Test OS8A was performed in the NASA/ARC unitary 11-foot section and OS8B was conducted in the NASA/ARC unitary 9 x 7 tunnel. Test objectives were to investigate thermal protection system (TPS) tile sensitivity to extreme pressure gradients and vibration and to define the TPS aerodynamic environment. The model utilized for OS8 was a full-scale representation of a portion of the space shuttle orbiter lower wing carry-through structure forward of the aft tank strut and propellant lines. Thermal protection tiles were simulated on the model. The model was instrumented with static pressure orifices, accelerometers, and dynamic pressure transducers (Kulites). A total rake was utilized to obtain boundary layer surveys.

Kingsland, R. B.↗

Laboratory tests on an aircraft fuselage to determine the insertion loss of various acoustic add-on treatments

This paper describes a laboratory study of add-on acoustic treatments for a propeller-driven light aircraft fuselage. The treatments included: no treatment (i.e., baseline fuselage); a production-type double-wall interior; and various amounts of high density fiberglass added to the baseline fuselage. The sound source was a pneumatic-driver with attached exponential horn, supplied with a broadband signal. Data were acquired at the approximate head positions of the six passenger seats. The results were analyzed on space-averaged narrowband, one-third octave band and overall insertion loss basis. In addition, insertion loss results for the different configurations at specific frequencies representing propeller tone spectra are presented. The propeller tone data includes not only the space-averaged insertion loss, but also the variation of insertion loss at these particular frequencies across the six microphone positions.

Heitman, K. E.↗

Turbofan aft duct suppressor study. Contractor's data report of mode probe signal data

Acoustic modal distributions were measured in a fan test model having an annular exhaust duct for comparison with theoretically predicted acoustic suppression values. This report contains the amplitude and phase data of the acoustic signals sensed by the transducers of the two mode probes employed in the measurement. Each mode probe consisted of an array of 12 transducers sensing the acoustic field at three axial positions and four radial positions.

Fiske, G. H.↗

Vibro-Acoustic Response of Buildings Due to Sonic Boom Exposure: June 2006 Field Test

During the month of June 2006, a series of structural response measurements were made on a house on Edwards Air Force Base (AFB) property that was excited by sonic booms of various amplitudes. Many NASA personnel other than the authors of this report from both Langley Research Center and Dryden Flight Research Center participated in the planning, coordination, execution, and data reduction for the experiment documented in this report. The purpose of this report is to document the measurements that were made, the structure on which they were made, the conditions under which they were made, the sensors and other hardware that were used, and the data that were collected.

Klos, Jacob↗

Microstructure Controlled Multi-Layer Porous Material Liner Tested On The Advanced Noise Control Fan

A novel concept of multilayer micro structurally controlled noise mitigation porous material was developed and experimentally validated in the laboratory by normal incidence impedance test. Extensive parametric studies were made to understand various parameters that influence acoustic absorption and transmission loss based on the test specimen size, particle size, porosity, pore size, and its distribution through the thickness. The results were reported in many publications. This work was focused on applying the concept and assessing the validity of the technology to aircraft turbomachine engines. The NASA Glenn Research Center’s Advanced Noise Control Fan (ANCF) low-speed test rig was selected. The liner insert required a 4-ft internal diameter cylinder with a 2-inch thick and 9-inch axial length. The liner was fabricated in eight segments and assembled in an aluminum test rig. The liner was tested for both tonal and broadband noise at the Notre Dame Turbomachinery Lab White Field test facility, where the ANCF is located. The study concludes that: Microstructurally controlled porous material is very effective in dissipating the sound energy; the liner is effective for tonal noise (2 to 13 dB reduction in noise levels) that constitutes the major part of the overall fan noise, especially the blade passing frequency which is generally the dominating component; Also, the liner is effective for broadband noise with reductions in sound pressure level of about 3 dB for the shaft order greater than 20. The proposed two-layer liner model demonstrated the validity of the concept. More studies are required to optimize the design.

Liner↗

Radiation boundary condition and anisotropy correction for finite difference solutions of the Helmholtz equation

In this paper finite-difference solutions of the Helmholtz equation in an open domain are considered. By using a second-order central difference scheme and the Bayliss-Turkel radiation boundary condition, reasonably accurate solutions can be obtained when the number of grid points per acoustic wavelength used is large. However, when a smaller number of grid points per wavelength is used excessive reflections occur which tend to overwhelm the computed solutions. Excessive reflections are due to the incompability between the governing finite difference equation and the Bayliss-Turkel radiation boundary condition. The Bayliss-Turkel radiation boundary condition was developed from the asymptotic solution of the partial differential equation. To obtain compatibility, the radiation boundary condition should be constructed from the asymptotic solution of the finite difference equation instead. Examples are provided using the improved radiation boundary condition based on the asymptotic solution of the governing finite difference equation. The computed results are free of reflections even when only five grid points per wavelength are used. The improved radiation boundary condition has also been tested for problems with complex acoustic sources and sources embedded in a uniform mean flow. The present method of developing a radiation boundary condition is also applicable to higher order finite difference schemes. In all these cases no reflected waves could be detected. The use of finite difference approximation inevita bly introduces anisotropy into the governing field equation. The effect of anisotropy is to distort the directional distribution of the amplitude and phase of the computed solution. It can be quite large when the number of grid points per wavelength used in the computation is small. A way to correct this effect is proposed. The correction factor developed from the asymptotic solutions is source independent and, hence, can be determined once and for all. The effectiveness of the correction factor in providing improvements to the computed solution is demonstrated in this paper.

Tam, Christopher K. W.↗

Initial Calibrations and Wind Tunnel Test Results for an In-Flow Reference Array Using New In-Flow Acoustic Sources in Four Array Mount Configurations

This paper describes efforts to develop a small in-flow phased microphone array as a reference acoustic sensor and quantify its level-measurement accuracy with new in-flow calibration sources. The devices can be applied to a wide variety of in- and out-of-flow measurement applications and test facilities. Recent tests of the array and two calibration sources in the NASA Anechoic Chamber and Army 7- by 10-foot Wind Tunnel at NASA Ames Research Center demonstrated that the array was functional over a frequency range of 2 to 100 kilohertz for emission angles of 92 degrees, 108 degrees, and 120 degrees, and Mach numbers of 0, 0.15, and 0.25. The array and calibration sources were then used to assess the relative effects of array installation on background noise and level measurement accuracy by locating the array in the flow (strut- and wall-mounted) as well as outside the flow behind a porous wall screen and a free shear layer. The wind tunnel array measurements were compared with anechoic chamber measurements using discrete microphones at the same source distance and emission angles. At 92 degrees, the noise floor and attenuation spectra were comparable (within 5 decibels) for each installation from 2 to 30 kilohertz. At higher angles, the array installation behind the Kevlar screen had the lowest noise floor at M = 0.15 and 0.25. The array installation 10 inches (maximum available distance) behind a free shear layer had higher background noise that is typically reduced to a lower level by moving the array back further from the flow. For emission angles greater than 92 degrees, both the Kevlar and free shear layer installations exhibited stronger attenuations in measured level, beginning at lower frequencies than either the wall- or strut-mount configurations. Additional array and calibration source units of the same design are being tested at NASA’s Glenn Research Center and Langley Research Center in their aeroacoustic research facilities in an effort to improve measurement accuracy and repeatability.

Aeroacoustic Wind Tunnel Research↗

Noncontact Acousto-Ultrasonic Testing With Laser Beams

Laser beams used to excite and detect acoustic waves in specimens. Laser/acousto-ultrasonic technique entails no mechanical contact between specimens and testing apparatus. Apparatus located at relatively large distances (meters) from specimens, making it possible to test specimens too hot for contact measurements or located in inaccessible places, vacuums, or hostile environments.

Huber, Robert D.↗