Search NASA⌕ Search

SEARCH · Search NASA

Results for “Acceleration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

ALACRITY: Analytics-Driven Lossless Data Compression for Rapid In-Situ Indexing, Storing, and Querying. In: Transactions on Large-Scale Data- and Knowledge-Centered Systems X. Lecture Notes in Computer Science, vol 8220

High-performance computing architectures face nontrivial data processing challenges, as computational and I/O components further diverge in performance trajectories. For scientific data analysis in particular, methods based on generating heavyweight access acceleration structures, e.g. indexes, are becoming less feasible for ever-increasing dataset sizes. We present ALACRITY, demonstrating the effectiveness of a fused data and index encoding of scientific, floating-point data in generating lightweight data structures amenable to common types of queries used in scientific data analysis. We exploit the representation of floating-point values by extracting significant bytes, using the resulting unique values to bin the remaining data along fixed-precision boundaries. To optimize query processing, we use an inverted index, mapping each generated bin to a list of records contained within, allowing us to optimize query processing with attribute range constraints. Overall, the storage footprint for both index and data is shown to be below numerous configurations of bitmap indexing, while matching or outperforming query performance.

Compression Ratio↗

Detecting Thermally-Induced Spinodal Decomposition with Picosecond Ultrasonics in Cast Austenitic Stainless Steels

Destructive techniques to monitor nuclear reactor component health may not always be available during service, as they are time-consuming and often require pre-installed inspection coupons. Non-destructive evaluation (NDE) techniques can bridge this gap by rapidly identifying the state of mission-critical reactor components, via inference between NDE-measurable material properties and those of ultimate interest, such as ductility and toughness. Here, we demonstrate one such inference about the health of thermally aged cast austenitic stainless steels. Observations of surface acoustic wave peak (SAW) splitting correlate with spinodal decomposition-induced embrittlement as destructively measured by Charpy impact energy. Elastodynamic calculations and molecular dynamics simulations of the effects of spinodal decomposition on elastic moduli support that the new acoustic modes present are due to stiffening in the δ-ferrite domains. Finally, this discovery enables one to probe structure-property relationships in materials in a greatly accelerated manner, suggesting that similar inference methods can be used to determine material fitness-for-service, or to quickly uncover new structure-property relationships.

304-type stainless steel↗

Bridging microscale to macroscale mechanical property measurements of FeCrAl alloys by crystal plasticity modeling

FeCrAl alloys are candidates for accident tolerant fuel cladding of light water reactors. In this work, a microstructure- and temperature-dependent crystal plasticity model is employed to bridge microscale to macroscale mechanical property measurements of FeCrAl alloys. With the visco-plastic self-consistent (VPSC) polycrystal plasticity framework, a mechanism-based single crystal plasticity (MSCP) model adopts the Arrhenius type rate equation to describe the dependence of the critical resolved shear stress for dislocation slips on their temperature-dependent intrinsic frictional resistance and the microstructure-dependent irradiation hardening. The intrinsic frictional resistance associated with {110}<111> and {112}<111> slip systems were measured by in-situ micromechanical testing on unirradiated/irradiated samples at 25-500 °C. The irradiation hardening is estimated by the Bacon-Kocks-Scattergood (BKS) model with density and size of radiation-induced defects measured from microstructural characterization. Several features associated with thermo-mechanical behavior of unirradiated/irradiated polycrystalline FeCrAl alloys are captured. High density of deformation-induced dislocations and radiation-induced defects results in obvious hardening at room temperature, which is weakened at high temperature, and facilitates damage evolution during deformation. Moreover, both high temperature and radiation-induced defects, which facilitate dislocation multiplication, trigger large hardening rate. Finally, the proposed method together with application of accelerator-based ion irradiation technique is a surrogate approach to simulate neutron damage, improving the efficiency associated with evaluation of mechanical properties of FeCrAl alloys exposed to temperature, stress and radiation conditions.

36 MATERIALS SCIENCE↗

Breath-Hold Target Localization With Simultaneous Kilovoltage/Megavoltage Cone-Beam Computed Tomography and Fast Reconstruction

Purpose: Hypofractionated high-dose radiotherapy for small lung tumors has typically been based on stereotaxy. Cone-beam computed tomography and breath-hold techniques have provided a noninvasive basis for precise cranial and extracranial patient positioning. The cone-beam computed tomography acquisition time of 60 s, however, is beyond the breath-hold capacity of patients, resulting in respiratory motion artifacts. By combining megavoltage (MV) and kilovoltage (kV) photon sources (mounted perpendicularly on the linear accelerator) and accelerating the gantry rotation to the allowed limit, the data acquisition time could be reduced to 15 s. Methods and Materials: An Elekta Synergy 6-MV linear accelerator, with iViewGT as the MV- and XVI as the kV-imaging device, was used with a Catphan phantom and an anthropomorphic thorax phantom. Both image sources performed continuous image acquisition, passing an angle interval of 90{sup o} within 15 s. For reconstruction, filtered back projection on a graphics processor unit was used. It reconstructed 100 projections acquired to a 512 x 512 x 512 volume within 6 s. Results: The resolution in the Catphan phantom (CTP528 high-resolution module) was 3 lines/cm. The spatial accuracy was within 2-3 mm. The diameters of different tumor shapes in the thorax phantom were determined within an accuracy of 1.6 mm. The signal-to-noise ratio was 68% less than that with a 180{sup o}-kV scan. The dose generated to acquire the MV frames accumulated to 82.5 mGy, and the kV contribution was <6 mGy. Conclusion: The present results have shown that fast breath-hold, on-line volume imaging with a linear accelerator using simultaneous kV-MV cone-beam computed tomography is promising and can potentially be used for image-guided radiotherapy for lung cancer patients in the near future.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A stochastic asymptotic-preserving scheme for a kinetic-fluid model for disperse two-phase flows with uncertainty

In this paper we consider a kinetic-fluid model for disperse two-phase flows with uncertainty. We propose a stochastic asymptotic-preserving (s-AP) scheme in the generalized polynomial chaos stochastic Galerkin (gPC-sG) framework, which allows the efficient computation of the problem in both kinetic and hydrodynamic regimes. The s-AP property is proved by deriving the equilibrium of the gPC version of the Fokker–Planck operator. The coefficient matrices that arise in a Helmholtz equation and a Poisson equation, essential ingredients of the algorithms, are proved to be positive definite under reasonable and mild assumptions. The computation of the gPC version of a translation operator that arises in the inversion of the Fokker–Planck operator is accelerated by a spectrally accurate splitting method. Numerical examples illustrate the s-AP property and the efficiency of the gPC-sG method in various asymptotic regimes.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Dosimetry of Small Circular Fields for 6-MeV Electron Beams

Small field electron beams used in the clinic present complex dosimetry. This investigation reports dosimetric characteristics of small 6-MeV electron field measurements and Monte Carlo calculations, and examines their impact on patient dosimetry. Radiographic film and ionization chamber were used for dosimetric measurements for a 6-MeV electron beam from a Varian 21EX linac. A set of circular cerrobend cutouts with diameters ranging from 2 to 3.0 cm was made. A clinical Monte Carlo algorithm was used to calculate dosimetric parameters. As the cutout diameter decreased, the build-up portion of the percentage depth dose (PDD) curves shifted toward the phantom surface, the depth of maximum dose, d{sub max,} decreased from 1.2 cm to 0.6 cm, but the practical range, R{sub p}, remained constant at about 3.1 cm. The absorbed dose rate, D{sub r}, decreased linearly with decreasing diameter. Profile coverage ratios CR (ie, the ratio of a given isodose line to the cutout diameter) at d{sub max}, for 90% and 80%, CR{sub 90}, CR{sub 80}, are approximately 55% and 73%, respectively. As the cutout diameter decreased, the 90% to 10% penumbra to diameter ratio, PR, increased from 0.49 to 0.56 for 3- to 2-cm cutouts. The total 90% to 10% penumbra was about the same size as the cutout diameter. The measured output factors were in good agreement with Monte Carlo calculation within 2.2%. Accurate small electron field measurements were performed using parallel plate ion chamber and film. The data were well supported by Monte Carlo calculations. These data facilitate routine clinical treatments for small cutouts as d{sub max}, D{sub r}, and other data can be quickly obtained instead of performing labor-intensive individual patient measurements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields

The Geant4 toolkit was used to develop a Monte Carlo (MC)-based engine for accurate dose calculations in small radiation field sizes. The Geant4 toolkit (version 10.1.p02) was used to simulate 6-MV photon beam of a Varian2100C linear accelerator that is being used for stereotactic radiosurgery (SRS) treatment with small radiation fields. Geometric models of 3 in-house designed radiosurgical divergent cones, with the diameters of their projections at the isocenter being 10, 20, and 30 mm, were simulated. The accuracy of the MC simulation technique was examined by reproducing several different simulated dosimetric parameters of the primary beams with the experimental data. The dose distributions are first checked for single beams for each cone, then standard multiple field (SMF) techniques are applied. A sample set of DICOM files from computed tomography (CT) scan imaging of a patient's head was converted to the Geant4 geometry format to implement MC-based engine for a clinical test. To validate the accuracy of the MC-based calculations for SMF arrangements, the isodose lines from MC simulation in water phantom were compared with the measured isodose lines using EBT3 Gafchromic film in Solid Water phantoms. Agreements between measured and simulated depth dose values and beam profiles for SRS cones were generally within 2%/2 mm. For output factors, the largest discrepancy was observed for 10 mm SRS cone, which was 1.7%. For SMF techniques, in SRS cones, the MC simulation and EBT3 Gafchromic film dosimetry were in acceptable agreement (5%/5 mm). Excellent agreement between the results of the MC-based and measured dose values for both single and SMF techniques in SRS cones indicates the ability of the Geant4 toolkit to be applied as the platform for treatment planning of advanced radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

When and how to treat an IMRT patient on a second accelerator without replanning?

When a linear accelerator is unavailable for treatment, a clinical decision is imminent regarding whether a patient should be treated on a linear accelerator other than the machine the patient was scheduled on, or whether treatment should be postponed until the original Linac becomes available. This work investigates the feasibility of switching patients to different accelerators for intensity-modulated radiation therapy (IMRT). We have performed Monte Carlo simulations of photon beams from different Linac models and vendors. Prostate and head and neck (H&N) treatment plans for Siemens Primus, Primart, and Varian 21EX accelerators are studied in this work. Dose distributions for given plans are recalculated using different beam data with the same nominal energy from different Linacs. We have compared dose-volume histograms (DVHs) and the maximum, the minimum, and the mean doses to the target and critical structures because of switching accelerators. In the process of switching a treatment plan to a different accelerator, issues exist, including optimum penumbra compensation, dose distribution at the boundary of target and critical structures, and multileaf collimator (MLC) leaf-width effects, which need to be considered and verified with measurements. Our Monte Carlo simulation results confirm that, for the cases we tested, the dose received by 95% of the planning target volume differs by 0.2% to 1.5% between Siemens Primus and Varian 21EX Linacs. The discrepancy is within our clinical acceptance criteria of 3% for IMRT treatments. In making the final decision on whether to switch machines or not, the tumor control probabilities (TCPs) based on a linear-quadratic model are compared. Based on the analyses performed in this work, it is therapeutically more beneficial to switch a patient to a different machine than to postpone a treatment until the original machine is available, especially for fast-growing tumors such as H&N cancers.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cyberknife stereotactic radiosurgery and radiation therapy treatment planning system

CyberKnife is an image-guided stereotactical dose delivery system designed for both focal irradiation and radiation therapy (SRT). Focal irradiation refers the use of many small beams to deliver highly focus dose to a small target region in a few fractions. The system consists of a 6-MV linac mounted to a robotic arm, coupled with a digital x-ray imaging system. The radiation dose is delivered using many beams oriented at a number of defined or nodal positions around the patients. The CyberKnife can be used for both intracranial and extracranial treaments unlike the Gamma Knife which is limited to intracranial cases. Multiplan (Accuray Inc., Sunnyvale, CA) is the treatment planning system developed to cooperate with this accurate and versatile SRS and SRT system, and exploit the full function of Cyberknife in high-precision radiosurgery and therapy. Optimized inverse treatment plan can be achieved by fine-tuning contours and planning parameters. Precision is the newest version of Cyberknife treatment planning system (TPS) and an upgrade to Multiplan. It offers several new features such as Monte Carlo for multileaf collimator (MLC) and retreatment for other modalities that added more support for the Cyberknife system. The Cybeknife TPS is an easy-to-use and versatile inverse planning platform, suitable for stereotactic radiosurgery and radiation therapy. The knowledge and experience of the planner in this TPS is essential to improve the quality of patient care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Use of high throughput screening methods to study dual-functional crosslinkable latexes

Herein, structure-formulation-property relationships for crosslinkable core-shell latexes were studied initially using high throughput screening methods and then using conventional experimental methods to determine optimum coating formulations. Two approaches that are used within coatings technology to improve sustainability are reduction in volatile organic compounds (VOC) and reduction in energy needed to cure coatings. Hybrid crosslinkable core-shell latexes have shown potential in meeting these challenges where film properties provided by particle coalescence are not sufficient and chemical crosslinking is needed. However, with numerous parameters involved such as latex particle architecture, nature and amount of crosslinker, and curing conditions, the screening of formulations via conventional coating testing methods becomes laborious and time-consuming. The results from high-throughput dye extraction and puncture testing were compared to data from conventional testing methods such as chemical resistance (MEK double rubs), pendulum hardness, and tensile testing to identify correlations. The dye extraction results have shown a strong correlation to solvent resistance and pendulum hardness data whereas toughness from puncture testing data correlated to tensile testing. Both high throughput dye extraction and puncture testing methods can be used for the accelerated screening of crosslinkable coating formulations to optimize curing parameters to achieve the best coating performance.

36 MATERIALS SCIENCE↗

NEML2: An efficient and modular multiphysics constitutive modeling library for hybrid computing environments

This paper presents NEML2, an open-source, high-performance library developed for constitutive material modeling, designed to support the flexible and modular development of models for complex material behavior. Building on the foundational structure of its predecessor, NEML, the NEML2 library introduces significant improvements, including enhanced vectorization, automatic differentiation, and seamless integration with PyTorch, facilitating the application of machine learning techniques in material simulations. NEML2 provides a C++ backend with Python bindings, enabling users to create custom material models that can be executed efficiently on both CPU and GPU platforms. The library also supports coupling with Multiphysics simulation frameworks like MOOSE, making it suitable for realistic simulations involving coupled physical processes. Rigorous quality assurance through unit and regression testing ensures the reliability of results, while the extensible, user-friendly design encourages collaboration and reproducibility across the scientific community. This paper provides an overview of NEML2’s architecture, core features, and applications, highlighting its impact on accelerating material qualification and advancing computational methods in materials science.

GPU↗

Intrinsic Li Distribution in Layered Transition-Metal Oxides Using Low-Dose Scanning Transmission Electron Microscopy and Spectroscopy

Understanding Li distribution in layered lithium transition-metal oxide (LiTMO) cathodes in Li-ion batteries has been a major challenge at the atomic scale and nanoscale. Li is extremely difficult to study by transmission electron microscopy (TEM) because the high-energy electrons impart significant energy and cause massive migration. Here, we directly map the intrinsic spatial distribution and bonding of Li in LiNiO 2 -layered cathode materials using low-dose and low-loss electron energy loss spectroscopy (EELS). EELS spectra of the Li–K edge are measured simultaneously with O–K and Ni–L, M 3,2 edges from layered, cation-mixed, and rock-salt phases and directly matched with atomic-resolution scanning TEM images to correlate the changes in peak intensities and positions to the stoichiometry changes with continual loss of Li and O. Changes in the Li content in the LiNiO 2 particles as a function of electron beam dose are studied by sequential Li spectroscopic mapping. We show that the “intrinsic” Li distribution can be observed using a total dose of less than ~1.5 × 10 8 e – nm –2 at an accelerating voltage of 80 kV. The method of nanoscale mapping of Li distribution introduced in this study is applicable to high-Ni LiTMO cathode materials (>89% of Ni) as well as LiNiO 2 . Further study on the extra peaks of the Li–K edge reveals that the peak at ~59 eV is from the Li ions intercalated in between NiO 2 layers barely interacting with each other with less Li K shell electrons pulled to the L shell electrons in NiO 2 . Furthermore, the results shown here provide improved low-loss TEM characterization approaches that can be used to understand the intrinsic fundamental behaviors in Li-ion batteries.

25 ENERGY STORAGE↗

High accuracy barrier heights, enthalpies, and rate coefficients for chemical reactions

Abstract Quantitative chemical reaction data, including activation energies and reaction rates, are crucial for developing detailed kinetic mechanisms and accurately predicting reaction outcomes. However, such data are often difficult to find, and high-quality datasets are especially rare. Here, we use CCSD(T)-F12a/cc-pVDZ-F12// ω B97X-D3/def2-TZVP to obtain high-quality single point calculations for nearly 22,000 unique stable species and transition states. We report the results from these quantum chemistry calculations and extract the barrier heights and reaction enthalpies to create a kinetics dataset of nearly 12,000 gas-phase reactions. These reactions involve H, C, N, and O, contain up to seven heavy atoms, and have cleaned atom-mapped SMILES. Our higher-accuracy coupled-cluster barrier heights differ significantly (RMSE of ∼5 kcal mol −1 ) relative to those calculated at ω B97X-D3/def2-TZVP. We also report accurate transition state theory rate coefficients $${k}_{\infty }(T)$$ k ∞ ( T ) between 300 K and 2000 K and the corresponding Arrhenius parameters for a subset of rigid reactions. We believe this data will accelerate development of automated and reliable methods for quantitative reaction prediction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Unusual flaring activity in the blazar PKS 1424-418 during 2008-2011

Context. Blazars are a subset of active galactic nuclei (AGN) with jets that are oriented along our line of sight. Variability and spectral energy distribution (SED) studies are crucial tools for understanding the physical processes responsible for observed AGN emission. Aims. We report peculiar behaviour in the bright γ-ray blazar PKS 1424-418 and use its strong variability to reveal information about the particle acceleration and interactions in the jet. Methods. Correlation analysis of the extensive optical coverage by the ATOM telescope and nearly continuous γ-ray coverage by the Fermi Large Area Telescope is combined with broadband, time-dependent modeling of the SED incorporating supplemental information from radio and X-ray observations of this blazar. Results. We analyse in detail four bright phases at optical-GeV energies. These flares of PKS 1424-418 show high correlation between these energy ranges, with the exception of one large optical flare that coincides with relatively low γ-ray activity. Although the optical/ γ-ray behaviour of PKS 1424-418 shows variety, the multiwavelength modeling indicates that these differences can largely be explained by changes in the flux and energy spectrum of the electrons in the jet that are radiating. We find that for all flares the SED is adequately represented by a leptonic model that includes inverse Compton emission from external radiation fields with similar parameters. Conclusions. Detailed studies of individual blazars like PKS 1424-418 during periods of enhanced activity in different wavebands are helping us identify underlying patterns in the physical parameters in this class of AGN.

Buson, S.↗

Simulation of Weibel Instability for LWFA and PWFA Electron Beams

Weibel instability is of central importance for relativistic beams both in laboratory, ex. fast-igniter concept for inertial confinement fusion, and astrophysical, ex. cosmic jets, plasmas. Simulations, using QuickPIC, of an intense and monoenergetic beam propagating through a plasma were conducted for experimental setups with Laser Wakefield and RF accelerators and show the appearance of Weibel instability (or current instability). The appearance of the instability is investigated as a function of beam parameters (density, spot size and bunch length) and plasma parameters (plasma density and length of plasma). We present preliminary simulation results that show that the instability should be observable for the RF accelerator experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionization oscillations in Hall accelerators

The underlying mechanism of low-frequency oscillations in Hall accelerators is investigated theoretically. It is shown that relaxation oscillations arise from a competition between avalanche ionization and the advective transport of the working gas. The model derived recovers the slow progression and fast recession of the ionization front. Analytical approximations of the shape of current pulses and of the oscillation frequency are provided for the case of large amplitude oscillations.

43 PARTICLE ACCELERATORS↗

The Interstellar H Flow: Updated Analysis of SOHO/SWAN Data

We update two kinds of results obtained with the SWAN instrument on board SOHO. First, we use H cell data recorded in 2001 and derive the H flow direction in the same way the study was done at solar minimum. We again compare with the Helium flow direction and doing so correct for the coordinate system change between the Ulysses and SOHO missions. The deflection plane we obtain is compatible with our previous result within error bars, confirming the potential predominant role of the interstellar magnetic field. In a second part, we extend the computation of the interstellar H ionization as a function of heliographic latitude and time, a quantity which reflects closely the SW flux latitudinal structure. The pattern for the present solar minimum is strikingly different from the previous minimum, with a much wider slow solar wind equatorial belt which persists until at least 2008. Comparing with synoptic LASCO/C2 electron densities we infer from a preliminary study that the acceleration of the high speed solar wind occurs at a higher altitude during this minimum compared to the previous one, a difference expansion models must be able to reproduce.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗