Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Normalizing VFO Frequency by Non-Powr-of-2 Division

PLL oscillator with VFO operating at one frequency yields any one of four frequencies by dividing by 4, 7, 21, or 52.5. Radiation resistant phase-locked loop oscillator generates output frequency 32 times any 1 or 4 specific input reference frequencies constructed without increasing component count over that of conventional circuit.

Anderson, C. R.↗

Transport And Chemical Effects On Concurrent And Opposed-Flow Flame Spread At Microgravity

Flame spread over flat solid fuel beds is a useful means of understanding more complex two-phase non-premixed spreading flames, such as those that may occur due to accidents in inhabited buildings and orbiting spacecraft. The role of buoyant convection on flame spread is substantial, especially for thermally-thick fuels. With suitable assumptions, deRis showed that the spread rate (S(sub f)) is proportional to the buoyant or forced convection velocity (U) and thus suggests that S(sub f) is indeterminate at mu g (since S(sub f) = U) unless a forced flow is applied. (In contrast, for thermally thin fuels, the ideal S(sub f) is independent of U.) The conventional view, as supported by computations and space experiments, is that for quiescent g conditions, S(sub f) must be unsteady and decreasing until extinction occurs due to radiative losses. However, this view does not consider that radiative transfer to the fuel surface can enhance flame spread. In recent work we have found evidence that radiative transfer from the flame itself can lead to steady flame spread at mu g over thick fuel beds. Our current work focuses on refining these experiments and a companion modeling effort toward the goal of a space flight experiment called Radiative Enhancement Effects on Flame Spread (REEFS) planned for the International Space Station (ISS) c. 2007.

Son, Y.↗

In-flight Far-Infrared Performance of the CIRS Instrument on Cassini

The Composite Infrared Spectrometer (CIRS) on-board Cassini consists of two interferometers: a conventional Michelson for the mid-infrared; and a Martin-Puplett type in the far-infrared employing wire grid polarizers to split, recombine and analyze the radiation. The far-IR focal plane (FP1) assembly uses two thermopile detectors to measure the final transmitted and reflected beams at the polarizer-analyzer: if one fails, the interferometer can still operate, albeit with a lower efficiency. The combined effect is for good response from 10 to 300/cm, and declining response to 600/cm. This paper will examine in-flight performance of the far-IR interferometer, including NESR and response. Regular noise spikes, resulting from pickup from other electrical sub-systems has been found on the CIRS interferograms, and the removal of these effects is discussed. The radiometric calibration is described, and then we show how the calibration was applied to science data taken during the Jupiter flyby of December 2000. Finally, we discuss signal-to-noise on the calibrated spectra, emphasizing limitations of the current instrument and the potential for improvement in future missions.

Nixon, Conor A.↗

Modeling and Validation of Damped Plexiglas Windows for Noise Control

Windows are a significant path for structure-borne and air-borne noise transmission in general aviation aircraft. In this paper, numerical and experimental results are used to evaluate damped plexiglas windows for the reduction of structure-borne and air-borne noise transmitted into the interior of an aircraft. In contrast to conventional homogeneous windows, the damped plexiglas windows were fabricated using two or three layers of plexiglas with transparent viscoelastic damping material sandwiched between the layers. Transmission loss and radiated sound power measurements were used to compare different layups of the damped plexiglas windows with uniform windows of the same nominal thickness. This vibro-acoustic test data was also used for the verification and validation of finite element and boundary element models of the damped plexiglas windows. Numerical models are presented for the prediction of radiated sound power for a point force excitation and transmission loss for diffuse acoustic excitation. Radiated sound power and transmission loss predictions are in good agreement with experimental data. Once validated, the numerical models were used to perform a parametric study to determine the optimum configuration of the damped plexiglas windows for reducing the radiated sound power for a point force excitation.

Buehrle, Ralph D.↗

SU-E-T-357: Electronic Compensation Technique to Deliver Total Body Dose

Purpose: Total body irradiation (TBI) uses large parallel-opposed radiation fields to suppress the patient’s immune system and eradicate the residual cancer cells in preparation of recipient for bone marrow transplant. The manual placement of lead compensators has conventionally been used to compensate for the varying thickness through the entire body in large-field TBI. The goal of this study is to pursue utilizing the modern electronic compensation technique to more accurately and efficiently deliver dose to patients in need of TBI. Methods: Treatment plans utilizing electronic compensation to deliver a total body dose were created retrospectively for patients for whom CT data had been previously acquired. Each treatment plan includes two, specifically weighted, pair of opposed fields. One pair of open, large fields (collimator=45°), to encompass the patient’s entire anatomy, and one pair of smaller fields (collimator=0°) focused only on the thicker midsection of the patient. The optimal fluence for each one of the smaller fields was calculated at a patient specific penetration depth. Irregular surface compensators provide a more uniform dose distribution within the smaller opposed fields. Results: Dose-volume histograms (DVH) were calculated for the evaluating the electronic compensation technique. In one case, the maximum body doses calculated from the DVH were reduced from the non-compensated 195.8% to 165.3% in the electronically compensated plans, indicating a more uniform dose with the region of electronic compensation. The mean body doses calculated from the DVH were also reduced from the non-compensated 120.6% to 112.7% in the electronically compensated plans, indicating a more accurate delivery of the prescription dose. All calculated monitor units were well within clinically acceptable limits. Conclusion: Electronic compensation technique for TBI will not substantially increase the beam on time while it can significantly reduce the compensator setup time and the potential risk of errors in manually placing lead compensators.

60 APPLIED LIFE SCIENCES↗

Mixed-Material Scintillators (MMSS Quarterly Report FY20Q2)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. This quarter, we delivered one the MMSS Particle-ID Modeling report, a major deliverable of this project. This report describes our results on simulations of the particle-ID (PID) class of detectors. We found that these detectors outperform competing approaches for neutron-gamma discrimination, neutron source pointing, and neutron spectroscopy. Further highlights of the report are described below. During this quarter, We alerted HQ to a change in schedule for the remaining simulations planned for this project: we plan to put off further simulation and reporting of the position-resolving (PR) detector class until July. This change in schedule has allowed us to go into additional detail in the PID work that is both very promising and motivates our upcoming proposal. The other active task in this project is prototyping 3D-printed scintillators with the aim of realizing the designs we’ve simulated. On that front, we had three focuses: measuring the light output, increasing the size of printed parts, and combining blue and green scintillators. We succeeded in measuring the light output, showing an output of 30% of commercial standard. This result leaves room for improvement but is within striking distance of where we need to be. We were on track to demonstrate a key requirement for increasing the size of parts and also to show combined green/blue prints before the laboratory moved to a Minimum Safe (MinSafe) Operations posture as a result of local Shelter In Place orders due to Covid-19.

42 ENGINEERING↗

Automated Voxel-Based Analysis of Volumetric Dynamic Contrast-Enhanced CT Data Improves Measurement of Serial Changes in Tumor Vascular Biomarkers

Objectives: Development of perfusion imaging as a biomarker requires more robust methodologies for quantification of tumor physiology that allow assessment of volumetric tumor heterogeneity over time. This study proposes a parametric method for automatically analyzing perfused tissue from volumetric dynamic contrast-enhanced (DCE) computed tomography (CT) scans and assesses whether this 4-dimensional (4D) DCE approach is more robust and accurate than conventional, region-of-interest (ROI)-based CT methods in quantifying tumor perfusion with preliminary evaluation in metastatic brain cancer. Methods and Materials: Functional parameter reproducibility and analysis of sensitivity to imaging resolution and arterial input function were evaluated in image sets acquired from a 320-slice CT with a controlled flow phantom and patients with brain metastases, whose treatments were planned for stereotactic radiation surgery and who consented to a research ethics board-approved prospective imaging biomarker study. A voxel-based temporal dynamic analysis (TDA) methodology was used at baseline, at day 7, and at day 20 after treatment. The ability to detect changes in kinetic parameter maps in clinical data sets was investigated for both 4D TDA and conventional 2D ROI-based analysis methods. Results: A total of 7 brain metastases in 3 patients were evaluated over the 3 time points. The 4D TDA method showed improved spatial efficacy and accuracy of perfusion parameters compared to ROI-based DCE analysis (P<.005), with a reproducibility error of less than 2% when tested with DCE phantom data. Clinically, changes in transfer constant from the blood plasma into the extracellular extravascular space (K{sub trans}) were seen when using TDA, with substantially smaller errors than the 2D method on both day 7 post radiation surgery (±13%; P<.05) and by day 20 (±12%; P<.04). Standard methods showed a decrease in K{sub trans} but with large uncertainty (111.6 ± 150.5) %. Conclusions: Parametric voxel-based analysis of 4D DCE CT data resulted in greater accuracy and reliability in measuring changes in perfusion CT-based kinetic metrics, which have the potential to be used as biomarkers in patients with metastatic brain cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increase of Cisplatinum therapeutic index through optical irradiation

The increase/modification of the Cisplatinum therapeutic index by neoplastic tissue exposure to optical radiation emitted between 400-2000 nm was studied; Cisplatinumum molecules do not absorb between 400 nm-2 {open_square}m. Doppler ultrasonography indicates that, following exposure, the living tissue local micro-vascularisation increases in a controlled and reversible way. The increase in the Cisplatinum therapeutic index may be produced by accelerating the intracellular hydrolyze processes due to the water molecules absorption in the near infrared. The irradiation makes possible the use of Cisplatinumum doses 10 times lower than in conventional chemotherapy; this generates lower secondary effects (kidney toxicity) while increasing the drug antineoplastic effect.

07 ISOTOPE AND RADIATION SOURCES↗

Absence of Intrinsic Ferromagnetic Interactions of Isolated and Paired Co Dopant Atoms in Zn 1-x Co x O with High Structural Perfection

We report element specific structural and magnetic investigations on Zn 1-x Co x O epitaxial films using synchrotron radiation. Co dopants exclusively occupy Zn sites as revealed by x-ray linear dichroism leading to a high degree of structural perfection. Comparative magnetic field dependent measurements by x-ray magnetic circular dichroism and conventional magnetometry consistently show purely paramagnetic behavior for isolated Co dopant atoms with a magnetic moment of 4.8μB. However, the total magnetization is reduced by ~30%, indicating that Co-O-Co pairs are antiferromagnetically coupled. We find no sign of intrinsic ferromagnetism in Co:ZnO films.

43 PARTICLE ACCELERATORS↗

TH-E-17A-11: Tracking Tumor’s Boundary in MV Image Sequences for Image-Guided Radiation Therapy

Purpose: To develop a level set method (LSM)-based algorithm to track the tumor’s boundary in MV image sequences for image-guided radiation therapy (IGRT). Method: Four MV image sequences, each of which consists of 100 frames at frame rate of 7.5 Hz, are acquired by using the electronic portal imaging device (EPID) (Varian Medical Systems, Pal Alto, USA) during the treatment of lung cancer. In the first frame of each sequence, we roughly delineate an initial contour of the target tumor by hand. Using a LSM-based algorithm, the initial contour can automatically shape itself to fit the tumor, and eventually detect the tumor’s boundary. We then employ the tumor’s boundary obtained from the previous frame as the initial contour in the subsequent frame, so that the LSM-based method can drive this initial contour to the tumor’s boundary quickly and fulfill a tracking task. Results: The proposed method has been evaluated on four MV image sequences. The mean tracking errors were 0.23, 0.29, 0.37, and 1.18 mm, and their corresponding standard deviations were 0.97, 0.75, 1.2 and 1.48 mm, respectively. Conclusion: Compared with conventional tumor tracking techniques, the proposed system is capable not only of tracking the tumor’s position, but also of detecting the tumor’s boundary varying with the respiration during the treatment. Considering current radiation therapy technique, for example, dynamical multi-leaf collimator (DMLC) has been widely applied in clinical treatment, this study indicates the potential for significant accuracy improvement in radiation therapy. This work was partially supported by a research grant from Varian Medical Systems (Palo Alto, California)

60 APPLIED LIFE SCIENCES↗

Calculation of hypersonic shock structure using flux-split algorithms

There exists an altitude regime in the atmosphere that is within the continuum domain, but wherein the conventional Navier-Stokes equations cease to be accurate. The altitude limits for this so called continuum transition regime depend on vehicle size and speed. Within this regime the thickness of the bow shock wave is no longer negligible when compared to the shock stand-off distance and the peak radiation intensity occurs within the shock wave structure itself. For this reason it is no longer valid to treat the shock wave as a discontinuous jump and it becomes necessary to compute through the shock wave itself. To accurately calculate hypersonic flowfields, the governing equations must be capable of yielding realistic profiles of flow variables throughout the structure of a hypersonic shock wave. The conventional form of the Navier-Stokes equations is restricted to flows with only small departures from translational equilibrium; it is for this reason they do not provide the capability to accurately predict hypersonic shock structure. Calculations in the continuum transition regime, therefore, require the use of governing equations other than Navier-Stokes. Several alternatives to Navier-Stokes are discussed; first for the case of a monatomic gas and then for the case of a diatomic gas where rotational energy must be included. Results are presented for normal shock calculations with argon and nitrogen.

Eppard, W. M.↗

Oral Mucositis Prevention By Low-Level Laser Therapy in Head-and-Neck Cancer Patients Undergoing Concurrent Chemoradiotherapy: A Phase III Randomized Study

Purpose: Oral mucositis is a major complication of concurrent chemoradiotherapy (CRT) in head-and-neck cancer patients. Low-level laser (LLL) therapy is a promising preventive therapy. We aimed to evaluate the efficacy of LLL therapy to decrease severe oral mucositis and its effect on RT interruptions. Methods and Materials: In the present randomized, double-blind, Phase III study, patients received either gallium-aluminum-arsenide LLL therapy 2.5 J/cm{sup 2} or placebo laser, before each radiation fraction. Eligible patients had to have been diagnosed with squamous cell carcinoma or undifferentiated carcinoma of the oral cavity, pharynx, larynx, or metastases to the neck with an unknown primary site. They were treated with adjuvant or definitive CRT, consisting of conventional RT 60-70 Gy (range, 1.8-2.0 Gy/d, 5 times/wk) and concurrent cisplatin. The primary endpoints were the oral mucositis severity in Weeks 2, 4, and 6 and the number of RT interruptions because of mucositis. The secondary endpoints included patient-reported pain scores. To detect a decrease in the incidence of Grade 3 or 4 oral mucositis from 80% to 50%, we planned to enroll 74 patients. Results: A total of 75 patients were included, and 37 patients received preventive LLL therapy. The mean delivered radiation dose was greater in the patients treated with LLL (69.4 vs. 67.9 Gy, p = .03). During CRT, the number of patients diagnosed with Grade 3 or 4 oral mucositis treated with LLL vs. placebo was 4 vs. 5 (Week 2, p = 1.0), 4 vs. 12 (Week 4, p = .08), and 8 vs. 9 (Week 6, p = 1.0), respectively. More of the patients treated with placebo had RT interruptions because of mucositis (6 vs. 0, p = .02). No difference was detected between the treatment arms in the incidence of severe pain. Conclusions: LLL therapy was not effective in reducing severe oral mucositis, although a marginal benefit could not be excluded. It reduced RT interruptions in these head-and-neck cancer patients, which might translate into improved CRT efficacy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Timelike Virtual Compton Scattering from Electron-Positron Radiative Annihilation

We propose measurements of the deeply virtual Compton amplitude (DVCS), gamma* to H H-bar gamma, in the timelike t = (p_{H} + p_{H-bar})^2 > 0 kinematic domain which is accessible at electron-positron colliders via the radiative annihilation process e+ e- to H H-bar gamma. These processes allow the measurement of timelike deeply virtual Compton scattering for a variety of H H-bar hadron pairs such as pi+ pi-, K+ K-, and D D-bar as well as p p-bar. As in the conventional spacelike DVCS, there are interfering coherent amplitudes contributing to the timelike processes involving C= - form factors. The interference between the amplitudes measures the phase of the C=+ timelike DVCS amplitude relative to the phase of the timelike form factors and can be isolated by considering the forward-backward e+ \leftrightarrow e- asymmetry. The J=0 fixed pole contribution which arises from the local coupling of the two photons to the quark current plays a special role. As an example we present a simple model.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic ordering and slow dynamics in a Ho-based bulk metallic glass with moderate random magnetic anisotropy

Results of magnetic measurements are presented for a Ho-based bulk metallic glass, which shows similarities and differences with conventional spin glasses (SGs), and significant differences with weak random magnetic anisotropy (RMA) systems. Both ac and dc magnetic measurements indicate a single transition from paramagnetic to speromagnetic or spin glasslike state around 5.6 K. The moderate RMA prevents the formation of long- (or quasilong)-range magnetic order and slows down the spin dynamics in the critical region. Further its isothermal remnant magnetization exhibits a small maximum, instead of a gradual increase with field in SGs. The roles of RMA in the magnetic structure and dynamics of disordered and frustrated systems are discussed by comparisons between the weak RMA system, the moderate or strong RMA system, and conventional SG.

36 MATERIALS SCIENCE↗

SU-F-BRD-13: Quantum Annealing Applied to IMRT Beamlet Intensity Optimization

Purpose: We report on the first application of quantum annealing (QA) to the process of beamlet intensity optimization for IMRT. QA is a new technology, which employs novel hardware and software techniques to address various discrete optimization problems in many fields. Methods: We apply the D-Wave Inc. proprietary hardware, which natively exploits quantum mechanical effects for improved optimization. The new QA algorithm, running on this hardware, is most similar to simulated annealing, but relies on natural processes to directly minimize the free energy of a system. A simple quantum system is slowly evolved into a classical system, representing the objective function. To apply QA to IMRT-type optimization, two prostate cases were considered. A reduced number of beamlets were employed, due to the current QA hardware limitation of ∼500 binary variables. The beamlet dose matrices were computed using CERR, and an objective function was defined based on typical clinical constraints, including dose-volume objectives. The objective function was discretized, and the QA method was compared to two standard optimization Methods: simulated annealing and Tabu search, run on a conventional computing cluster. Results: Based on several runs, the average final objective function value achieved by the QA was 16.9 for the first patient, compared with 10.0 for Tabu and 6.7 for the SA. For the second patient, the values were 70.7 for the QA, 120.0 for Tabu, and 22.9 for the SA. The QA algorithm required 27–38% of the time required by the other two methods. Conclusion: In terms of objective function value, the QA performance was similar to Tabu but less effective than the SA. However, its speed was 3–4 times faster than the other two methods. This initial experiment suggests that QA-based heuristics may offer significant speedup over conventional clinical optimization methods, as quantum annealing hardware scales to larger sizes.

07 ISOTOPE AND RADIATION SOURCES↗

Forecasting of preprocessed daily solar radiation time series using neural networks

In this paper, we present an application of Artificial Neural Networks (ANNs) in the renewable energy domain. We particularly look at the Multi-Layer Perceptron (MLP) network which has been the most used of ANNs architectures both in the renewable energy domain and in the time series forecasting. We have used a MLP and an ad hoc time series pre-processing to develop a methodology for the daily prediction of global solar radiation on a horizontal surface. First results are promising with nRMSE {proportional_to} 21% and RMSE {proportional_to} 3.59 MJ/m{sup 2}. The optimized MLP presents predictions similar to or even better than conventional and reference methods such as ARIMA techniques, Bayesian inference, Markov chains and k-Nearest-Neighbors. Moreover we found that the data pre-processing approach proposed can reduce significantly forecasting errors of about 6% compared to conventional prediction methods such as Markov chains or Bayesian inference. The simulator proposed has been obtained using 19 years of available data from the meteorological station of Ajaccio (Corsica Island, France, 41 55'N, 8 44'E, 4 m above mean sea level). The predicted whole methodology has been validated on a 1.175 kWc mono-Si PV power grid. Six prediction methods (ANN, clear sky model, combination..) allow to predict the best daily DC PV power production at horizon d + 1. The cumulated DC PV energy on a 6-months period shows a great agreement between simulated and measured data (R{sup 2} > 0.99 and nRMSE < 2%). (author)

14 SOLAR ENERGY↗

A hybrid-drive nonisobaric-ignition scheme for inertial confinement fusion

A new hybrid-drive (HD) nonisobaric ignition scheme of inertial confinement fusion (ICF) is proposed, in which a HD pressure to drive implosion dynamics increases via increasing density rather than temperature in the conventional indirect drive (ID) and direct drive (DD) approaches. In this HD (combination of ID and DD) scheme, an assembled target of a spherical hohlraum and a layered deuterium-tritium capsule inside is used. The ID lasers first drive the shock to perform a spherical symmetry implosion and produce a large-scale corona plasma. Then, the DD lasers, whose critical surface in ID corona plasma is far from the radiation ablation front, drive a supersonic electron thermal wave, which slows down to a high-pressure electron compression wave, like a snowplow, piling up the corona plasma into high density and forming a HD pressurized plateau with a large width. The HD pressure is several times the conventional ID and DD ablation pressure and launches an enhanced precursor shock and a continuous compression wave, which give rise to the HD capsule implosion dynamics in a large implosion velocity. The hydrodynamic instabilities at imploding capsule interfaces are suppressed, and the continuous HD compression wave provides main pdV work large enough to hotspot, resulting in the HD nonisobaric ignition. The ignition condition and target design based on this scheme are given theoretically and by numerical simulations. It shows that the novel scheme can significantly suppress implosion asymmetry and hydrodynamic instabilities of current isobaric hotspot ignition design, and a high-gain ICF is promising.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Comparison of F ratios generated from interphase and metaphase chromosome damage induced by high doses of low- and high-LET radiation

Although biophysical models predict a difference in the ratio of interchromosomal to intrachromosomal interarm exchanges (F ratio) for low- and high-LET radiations, few experimental data support this prediction. However, the F ratios in experiments to date have been generated using data on chromosome aberrations in samples collected at the first postirradiation mitosis, which may not be indicative of the aberrations formed in interphase after exposure to high-LET radiations. In the present study, we exposed human lymphocytes in vitro to 2 and 5 Gy of gamma rays and 3 Gy of 1 GeV/nucleon iron ions (LET = 140 keV/micrometer), stimulated the cells to grow with phytohemagglutinin (PHA), and collected the condensed chromosomes after 48 h of incubation using both chemically induced premature chromosome condensation (PCC) and the conventional metaphase techniques. The PCC technique used here condenses chromosomes mostly in the G(2) phase of the cell cycle. The F ratio was calculated using data on asymmetrical chromosome aberrations in both the PCC and metaphase samples. It was found that the F ratios were similar for the samples irradiated with low- and high-LET radiation and collected at metaphase. However, for irradiated samples assayed by PCC, the F ratio was found to be 8.2 +/- 2.0 for 5 Gy gamma rays and 5.2 +/- 0.9 for 3 Gy iron ions. The distribution of the aberrations indicated that, in the PCC samples irradiated with iron ions, most of the centric rings occurred in spreads containing five or more asymmetrical aberrations. These heavily damaged cells, which were either less likely to reach mitosis or may reach mitosis at a later time, were responsible for the difference in the F ratios generated from interphase and metaphase analysis after exposure to iron ions.

NASA Discipline Radiation Health↗