Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Science”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Advancing Fusion with Machine Learning Research Needs Workshop

The pursuit of fusion energy has required extensive experimental and theoretical science activities to develop the knowledge needed that will enable design of successful fusion power plants. Even today, following decades of research in many key areas including plasma physics and material science, much remains to be learned to enable optimization of the tokamak or other paths to fusion energy. Data science methods from the fields of machine learning and artificial intelligence (ML/AI) offer opportunities for enabling or accelerating progress toward the realization of fusion energy by maximizing the amount and usefulness of information extracted from experimental and simulation output data. Jointly supported by the Department of Energy Offices of Fusion Energy Science (FES) and Advanced Scientific Computing Research (ASCR), a workshop was organized to identify Priority Research Opportunities (PRO’s) for application of ML/AI methods to enable accelerated solution of fusion problems. The resulting “Advancing Fusion with Machine Learning Research Needs Workshop,” held in Gaithersburg, MD, April 30 – May 2, 2019, brought together ~ 60 experts in fields spanning fusion science, data science, statistical inference and mathematics, machine learning, and artificial intelligence, along with DOE program managers and technical experts, to identify key PRO’s.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Continuous CO2 extractor and methods

The purpose of this CRADA was to assist in technology transfer from Russia to the US and assist in development of the technology improvements and applications for use in the U.S. and worldwide. Over the period of this work, ORNL has facilitated design, development and demonstration of a low-pressure liquid extractor and development of initial design for high-pressure supercritical CO2 fluid extractor.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF A NEW TYPE A(F)RADIOACTIVE MATERIAL PACKAGING FOR THE DEPARTMENT OF ENERGY

In a coordinated effort, the Department of Transportation (DOT) and Nuclear Regulatory Commission (NRC) proposed the elimination of the Specification Packaging from 49 CFR 173.[1] In accordance with the Federal Register, issued on October 1, 2004, new fabrication of Specification Packages would no longer be authorized. In accordance with the NRC final rulemaking published January 26, 2004, Specification Packagings are mandated by law to be removed from service no later than October 1, 2008. This coordinated effort and resulting rulemaking initiated a planned phase out of Specification Type B and Type A fissile (F) material transportation packages within the Department of Energy (DOE) and its subcontractors. One of the Specification Packages affected by this regulatory change is the UN1A2 Specification Package, per DOT 49 CFR 173.417(a)(6). To maintain continuing shipments of DOE materials currently transported in UN1A2 Specification Package after the existing authorization expires, a replacement Type A(F) material packaging design is under development by the Savannah River National Laboratory. This paper presents a summary of the prototype design effort and testing of the new Type A(F) Package development for the DOE. This paper discusses the progress made in the development of a Type A Fissile Packaging to replace the expiring 49 CFR UN1A2 Specification Fissile Package. The Specification Package was mostly a single-use waste disposal container. The design requirements and authorized radioactive material contents of the UN1A2 Specification Package were defined in 49 CFR. A UN1A2 Specification Package was authorized to ship up to 350 grams of U-235 in any enrichment and in any non-pyrophoric form. The design was specified as a 55-gallon 1A2 drum overpack with a body constructed from 18 gauge steel with a 16 gauge drum lid. Drum closure was specified as a standard 12-gauge ring closure. The inner product container size was not specified but was listed as any container that met Specification 7A requirements per 49 CFR 178.350. Specification 7A containers were required to withstand Type A packaging tests required by 49CFR173.465 with compliance demonstrated through testing, analysis or similarity to other containers. The maximum weight of the 7A product container, the radioactive content, and any internal packaging was limited to 200 lbs. The total gross weight for the UN1A2 Specification Package was limited to 350 lbs. No additional restrictions were applied. Authorization for use did not require the UN1A2 Specification Package to be tested to the Normal Conditions of Transport (NCT) and Hypothetical Accident Conditions (HAC) required for performance based, Type A(F) packages certified by the NRC or DOE. The Type A(F) Packaging design discussed in this paper is required to be in compliance with the regulatory safety requirements defined in Code of Federal Regulations (CFR) 10 CFR 71.41 through 71.47 and 10 CFR71.71. Sub-criticality of content must be maintained under the Hypothetical Accident Conditions specified under 10 CFR71.73. These federal regulations, and other applicable DOE Orders and Guides, govern design requirements for a Type A(F) package. Type A(F) packages with less than an A2 quantity of radioactive material are not required to have a leak testable boundary. With this exception a Type A(F) package design is subject to the same test requirements set forth for the design of a performance based Type B packaging.

36 MATERIALS SCIENCE↗

The co-crystal structure of ubiquitin carboxy-terminal hydrolase L1 (UCHL1) with a tripeptide fluoromethyl ketone (Z-VAE(OMe)-FMK)

UCHL1 is a 223 amino acid member of the UCH family of deubiquitinating enzymes (DUBs), found abundantly and exclusively expressed in neurons and the testis in normal tissues. Two naturally occurring variants of UCHL1 are directly involved in Parkinson's disease (PD). Not only has UCHL1 been linked to PD, but it has oncogenic properties, having been found abnormally expressed in lung, pancreatic, and colorectal cancers. Although inhibitors of UCHL1 have been described previously the co-crystal structure of the enzyme bound to any inhibitor has not been reported. Herein, we report the X-ray structure of UCHL1 co-crystallized with a peptide-based fluoromethylketone inhibitor, Z-VAE(OMe)-FMK (VAEFMK) at 2.35 {angstrom} resolution. The co-crystal structure reveals that the inhibitor binds in the active-site cleft, irreversibly modifying the active-site cysteine; however, the catalytic histidine is still misaligned as seen in the native structure, suggesting that the inhibitor binds to an inactive form of the enzyme. Our structure also reveals that the inhibitor approaches the active-site cleft from the opposite side of the crossover loop as compared to the direction of approach of ubiquitin's C-terminal tail, thereby occupying the P1{prime} (leaving group) site, a binding site perhaps used by the unknown C-terminal extension of ubiquitin in the actual in vivo substrate(s) of UCHL1. This structure provides a view of molecular contacts at the active-site cleft between the inhibitor and the enzyme as well as furnishing structural information needed to facilitate further design of inhibitors targeted to UCHL1 with high selectivity and potency.

59 BASIC BIOLOGICAL SCIENCES↗

A fiber-optic interferometer with subpicometer resolution for dc and low-frequency displacement measurement

We have developed a fiber-optic interferometer optimized for best performance in the frequency range from dc to 1 kHz, with displacement linearity of 1% over a range of {+-} 25 nm, and noise-limited resolution of 2 pm. The interferometer uses a tunable infrared laser source (nominal 1550 nm wavelength) with high amplitude and wavelength stability, low spontaneous self-emission noise, high sideband suppression, and a coherence control feature that broadens the laser linewidth and dramatically lowers the low-frequency noise in the system. The amplitude stability of the source, combined with the use of specially manufactured ''bend-insensitive'' fiber and all-spliced fiber construction, results in a robust homodyne interferometer system, which achieves resolution of 40 fm Hz{sup -1/2} above 20 Hz and approaches the shot-noise-limit of 20 fm Hz{sup -1/2} at 1 kHz for an optical power of 10 {mu}W, without the need for differential detection. Here we describe the design and construction of the interferometer, as well as modes of operation, and demonstrate its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: A short-pulse high-intensity molecular beam valve based on a piezoelectric stack actuator

Solenoid and piezoelectric disk valves, which are widely used to generate molecular beam pulses, still suffer from significant restrictions, such as pulse durations typically >50 μs, low repetition rates, and limited gas flows and operational times. Much of this arises owing to the limited forces these actuators can achieve. To overcome these limitations, we have developed a new pulsed valve based on a high-force piezoelectric stack actuator. We show here that operation with pulse durations as low as 20 μs and repetition rates up to 100 Hz can be easily achieved by operating the valve in conjunction with a commercial fast high-voltage switch. We outline our design and demonstrate its performance with molecular beam characterization via velocity map ion imaging.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Inverse-Designed Photonics for Semiconductor Foundries

Silicon photonics is becoming a leading technology in photonics, displacing traditional fiber optic transceivers and enabling new applications. Further improving the density and performance of silicon photonics, however, has been challenging due to the large size and limited performance of traditional semianalytically designed components. Automated optimization of photonic devices using inverse design is a promising path forward but has, until now, faced difficulties in producing designs that can be fabricated reliably at scale. In this paper we experimentally demonstrate four inverse-designed devices made successfully in a commercial silicon photonics foundry: a spatial mode multiplexer, wavelength demultiplexer, 50–50 directional coupler, and 3-way power splitter. These devices are efficient, robust to fabrication variability, and compact, with footprints only a few micrometers across. They pave the way forward for the widespread practical use of inverse design.

36 MATERIALS SCIENCE↗

3D DNA Crystals and Nanotechnology

DNA's molecular recognition properties have made it one of the most widely used biomacromolecular construction materials. The programmed assembly of DNA oligonucleotides has been used to create complex 2D and 3D self-assembled architectures and to guide the assembly of other molecules. The origins of DNA nanotechnology are rooted in the goal of assembling DNA molecules into designed periodic arrays, i.e., crystals. Here, we highlight several DNA crystal structures, the progress made in designing DNA crystals, and look at the current prospects and future directions of DNA crystals in nanotechnology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sintering of Iron Ores in a Millipot in Comparison with Tablet Testing and Industrial Process

To explore the feasibility of small-scale sintering pot testing, a ‘millipot’ facility (diameter of 53 mm and height of 400 mm) was established and used to examine the sintering performance of iron ores and other non-traditional ferrous materials. The sintering performance of a millipot was examined across a range of different operational conditions (coke rate and suction pressure) and compared with an industrial sinter strand operation. Tablet tests were also performed to assist in the design of the millipot experiments and identify conditions for achieving mineral composition similar to the industrial sinter. For the millipot experiments, the materials used need to be compacted to increase the bulk density, and a higher coke rate is required to compensate the high heat loss caused by wall effects. A higher suction pressure is also necessary to maintain an oxidizing atmosphere in the sinter bed. As expected, it was not possible to eliminate the wall effect, which resulted in more primary hematite at edges of the sintered column. However, the sintered material from the center of column simulates industrial sinter reasonably well. As such, millipot provides a practical way to evaluate the sintering process and material performance at laboratory scale, helping to bridge the gap between tablet sintering and large scale pot sintering, or full scale plant trial. The results of millipot testing can be used for designing larger scale experiments or commercial sintering trials.

36 MATERIALS SCIENCE↗

Evaluating the benefits of kinetic Monte Carlo and microkinetic modeling for catalyst design studies in the presence of lateral interactions

Popular computational catalyst design strategies rely on the identification of reactivity descriptors, which can be used along with Brønsted–Evans–Polanyi (BEP) and scaling relations as input to a microkinetic model (MKM) to make predictions for activity or selectivity trends. The main benefit of this approach is related to the inherent dimensionality reduction of the large material space to just a few catalyst descriptors. Conversely, it is well documented that a small set of descriptors is insufficient to capture the intricacies and complexities of a real catalytic system. The inclusion of coverage effects through lateral adsorbate-adsorbate interactions can narrow the gap between simplified descriptor predictions and real systems, but mean-field MKMs cannot properly account for local coverage effects. This shortcoming of the mean-field approximation can be rectified by switching to a lattice-based kinetic Monte Carlo (kMC) method using cluster expansion representation of adsorbate–adsorbate lateral interactions. Using the prototypical CO oxidation reaction as an example, we critically evaluate the benefits of kMC over MKM in terms of trend predictions and computational cost when using only a small set of input parameters. After confirming that in the absence of lateral interactions the kMC and MKM approaches yield identical trends and mechanistic information, we observed substantial differences between the two kinetic models when lateral interactions were introduced. Here, the mean-field implementation applies coverage corrections directly to the descriptors, causing an artificial overprediction of the activity of strongly binding metals. In contrast, the cluster expansion in kMC implementation can differentiate among the highly active metals but it is very sensitive to the set of included interaction parameters. Considering that computational screening relies on a minimal set of descriptors, for which MKM makes reasonable trend predictions at a ca. three orders of magnitude lower computational cost than kMC, the MKM approach does provide a better entry point for computational catalyst design.

36 MATERIALS SCIENCE↗

Structural basis of CX-4945 binding to human protein kinase CK2

Protein kinase CK2 (CK2), a constitutively active serine/threonine kinase, is involved in a variety of roles essential to the maintenance of cellular homeostasis. Elevated levels of CK2 expression results in the dysregulation of key signaling pathways that regulate transcription, and has been implicated in cancer. The adenosine-5'-triphosphate-competitive inhibitor CX-4945 has been reported to show broad spectrum anti-proliferative activity in multiple cancer cell lines. Although the enzymatic IC{sub 50} of CX-4945 has been reported, the thermodynamics and structural basis of binding to CK2{alpha} remained elusive. Presented here are the crystal structures of human CK2{alpha} in complex with CX-4945 and adenylyl phosphoramidate at 2.7 and 1.3 {angstrom}, respectively. Biophysical analysis of CX-4945 binding is also described. This data provides the structural rationale for the design of more potent inhibitors against this emerging cancer target.

59 BASIC BIOLOGICAL SCIENCES↗

Binding of 3,4,5,6-Tetrahydroxyazepanes to the Acid-[beta]-glucosidase Active Site: Implications for Pharmacological Chaperone Design for Gaucher Disease

Pharmacologic chaperoning is a therapeutic strategy being developed to improve the cellular folding and trafficking defects associated with Gaucher disease, a lysosomal storage disorder caused by point mutations in the gene encoding acid-{beta}-glucosidase (GCase). In this approach, small molecules bind to and stabilize mutant folded or nearly folded GCase in the endoplasmic reticulum (ER), increasing the concentration of folded, functional GCase trafficked to the lysosome where the mutant enzyme can hydrolyze the accumulated substrate. To date, the pharmacologic chaperone (PC) candidates that have been investigated largely have been active site-directed inhibitors of GCase, usually containing five- or six-membered rings, such as modified azasugars. Here we show that a seven-membered, nitrogen-containing heterocycle (3,4,5,6-tetrahydroxyazepane) scaffold is also promising for generating PCs for GCase. Crystal structures reveal that the core azepane stabilizes GCase in a variation of its proposed active conformation, whereas binding of an analogue with an N-linked hydroxyethyl tail stabilizes GCase in a conformation in which the active site is covered, also utilizing a loop conformation not seen previously. Although both compounds preferentially stabilize GCase to thermal denaturation at pH 7.4, reflective of the pH in the ER, only the core azepane, which is a mid-micromolar competitive inhibitor, elicits a modest increase in enzyme activity for the neuronopathic G202R and the non-neuronopathic N370S mutant GCase in an intact cell assay. Our results emphasize the importance of the conformational variability of the GCase active site in the design of competitive inhibitors as PCs for Gaucher disease.

59 BASIC BIOLOGICAL SCIENCES↗

An electrostatic autoresonant ion trap mass spectrometer

A new method for ion extraction from an anharmonic electrostatic trap is introduced. Anharmonicity is a common feature of electrostatic traps which can be used for small scale spatial confinement of ions, and this feature is also necessary for autoresonant ion extraction. With the aid of ion trajectory simulations, novel autoresonant trap mass spectrometers (ART-MSs) have been designed based on these very simple principles. A mass resolution {approx}60 is demonstrated for the prototypes discussed here. We report also on the pressure dependencies, and the (mV) rf field strength dependencies of the ART-MS sensitivity. Importantly the new MS designs do not require heavy magnets, tight manufacturing tolerances, introduction of buffer gases, high power rf sources, nor complicated electronics. The designs described here are very inexpensive to implement relative to other instruments, and can be easily miniaturized. Possible applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and construction of a high-resolution velocity-map imaging apparatus for photoelectron spectroscopy studies of size-selected clusters

A new velocity-map imaging apparatus equipped with a laser-vaporization supersonic cluster source and a time-of-flight mass spectrometer is described for high-resolution photoelectron spectroscopy studies of size-selected cluster anions. Vibrationally cold anion clusters are produced using a laser-vaporization supersonic cluster source, size-selected by a time-of-flight mass spectrometer, and then focused co-linearly into the interaction zone of the high-resolution velocity-map imaging (VMI) system. The multilens VMI system is optimized via systematic simulations and can reach a resolution of 1.2 cm{sup −1} (FWHM) for near threshold electrons while maintaining photoelectron kinetic energy resolutions (ΔKE/KE) of ∼0.53% for higher energy electrons. The new VMI lens has superior focusing power over a large energy range, yielding highly circular images with distortions no larger than 1.0025 between the long and short radii. The detailed design, simulation, construction, testing, and performance of the high-resolution VMI apparatus are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of 1 × 10{sup −15}

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of 1 × 10{sup −15} at integration times between 1 and 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission Space-Time Explorer and QUantum Equivalence Principle Space Test (STE-QUEST) ( http://sci.esa.int/ste-quest/ ). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are 40 cm × 20 cm × 30 cm. The acceleration sensitivities of the optical frequency in the three directions were measured to be 1.7 × 10{sup −11}/g, 8.0 × 10{sup −11}/g, and 3.9 × 10{sup −10}/g, and the absolute frequency instability was determined via a three-cornered hat measurement. Two additional cavity-stabilized lasers were used for this purpose, one of which had an instability σ{sub y} < 4 × 10{sup −16} at 1 s integration time. The design is also appropriate and useful for terrestrial applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The structure of myostatin:follistatin 288: insights into receptor utilization and heparin binding

Myostatin is a member of the transforming growth factor-{beta} (TGF-{beta}) family and a strong negative regulator of muscle growth. Here, we present the crystal structure of myostatin in complex with the antagonist follistatin 288 (Fst288). We find that the prehelix region of myostatin very closely resembles that of TGF-{beta} class members and that this region alone can be swapped into activin A to confer signalling through the non-canonical type I receptor Alk5. Furthermore, the N-terminal domain of Fst288 undergoes conformational rearrangements to bind myostatin and likely acts as a site of specificity for the antagonist. In addition, a unique continuous electropositive surface is created when myostatin binds Fst288, which significantly increases the affinity for heparin. This translates into stronger interactions with the cell surface and enhanced myostatin degradation in the presence of either Fst288 or Fst315. Overall, we have identified several characteristics unique to myostatin that will be paramount to the rational design of myostatin inhibitors that could be used in the treatment of muscle-wasting disorders.

36 MATERIALS SCIENCE↗

Note: Design and development of improved indirectly heated cathode based strip electron gun

An improved design of indirectly heated solid cathode based electron gun (200 kW, 45 kV, 270° bent strip type electron gun) has been presented. The solid cathode is made of thoriated tungsten, which acts as an improved source of electron at lower temperature. So, high power operation is possible without affecting structural integrity of the electron gun. The design issues are addressed based on the uniformity of temperature on the solid cathode and the single long filament based design. The design approach consists of simulation followed by extensive experimentation. In the design, the effort has been put to tailor the non-uniformity of the heat flux from the filament to the solid cathode to obtain better uniformity of temperature on the solid cathode. Trial beam experiments have been carried out and it is seen that the modified design achieves one to one correspondence of the solid cathode length and the electron beam length.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗