Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Power Generation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Ensuring Solution Uniqueness in Three-Phase Power System State Estimation

This paper is concerned with the issue of potential non-unique solutions in three-phase state estimation. Theory of observability analysis for positive sequence power system state estimation is based on certain assumptions that avoid possibility of multiple solutions. Also, it is shown that observability of a positive sequence network remains independent of the network parameters or the operating state. When extending single-phase observability analysis directly to the three-phase case, this paper considers the possibility of converging to multiple solutions, i.e. solution non-uniqueness, even for cases where state estimator successfully converges. The study illustrates via numerical examples the likelihood of converging to entirely different solutions for certain network parameters. It also examines how the operating state, particularly under unbalanced loading, leads to solution non-uniqueness. The paper then describes an alternative approach to ensure a unique solution in three-phase state estimation. This method aims to accurately and uniquely estimate the state of any unbalanced three-phase system, irrespective of load imbalance, network configuration, existence of synchronous generators or transformers.

Power System State Estimation, Three-Phase, Distri↗

Survivability of Autonomous Microgrid during Overload Events

Grid-forming sources are voltage sources that draw necessary currents to meet any load changes. A load step can cause part or all of these sources to become overloaded in a microgrid. This paper presents an overload mitigation controller that addresses the two overload issues in a microgrid by actively controlling the sources’ frequency. When part of the sources in a microgrid is overloaded, the controller autonomously transfers the extra load to other sources by rapidly reducing its frequency. The frequency difference between sources during transient results in a change of phase angle, which redistributes the power flow. When all sources in a microgrid are overloaded, each source keeps dropping the frequency. Therefore, under frequency load shedding can be used to trip the non-critical loads resulting in the survival of microgrid. The advantages of these concepts are that communications between sources are not needed during transient, and the robust voltage control is maintained. Lastly, simulation and field tests from CERTS/AEP microgrid test site verify that the control strategy is effective in both purely inverter-based microgrids and inverter & generator mixed microgrids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Energy Storage to Support Puerto Rico's Transmission System

As part of the DOE's multi-laboratory effort to provide analysis and tools to support reconstruction and modernization of the Puerto Rico electric grid, Sandia National Laboratory was tasked with making recommendations for how to use energy storage to support the transmission system. Puerto Rico's electric grid is outdated and still recovering from the 2017 hurricane season, and targeted improvements are needed to restore reliability and to provide resilience for future extreme events. This report examined the most critical near-term issues with the transmission system: frequency regulation and response, and analyzed the impacts of incorporating energy storage systems of varying sizes with the goal of immediately minimizing load shedding while laying the foundation for future renewable energy integration. The analysis concluded that 240 MW/60 MWh of energy storage would stabilize system frequency sufficiently to avoid loss of load for rapid load changes or generation outages up to and including loss of the largest generation unit on the island.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High Performance Adaptive Deep-Reinforcement-Learning-based Real-time Emergency Control (HADREC) to Enhance Power Grid Resilience in Stochastic Environment (Final Report)

The HADREC technology developed in this project features real-time, validated, and predictive emergency control capabilities needed to effectively safeguard the grid against costly disturbances from extreme weather and other disruptive events. It has the potential to revolutionize the emergency control by providing faster and more effective solution for power grid emergency control. The technology can reduce the grid emergency control action time from minutes to seconds and mitigate the impact of outages and reduce system recovery time. The evaluation results using the models and data from PacifiCorp system have shown ~20% improvement in responding time and 70% improved in tripped generator output, comparing against today’s industrial application. This performance can help reduce preventive measurements and improve network utilization and market efficiency, and help lead to a more reliable and resilient power grid with renewable integration. The project has generated significant interest from industry, academic and commercial companies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

New Jersey Transit Grid Distributed Generation Program. Cybersecurity Design Assurance Assessment

Superstorm Sandy caused a major disruption to passenger-rail and other commuter systems throughout New York and New Jersey. To address this issue, New Jersey Transit (NJT) established the NJ TRANSITGRID project, an effort designed to power bus, ferry, and limited passenger-rail service during natural or man-made disasters. Given the importance of these transportation systems, NJT partnered with Sandia National Laboratories (Sandia) to assess the cyber-resilience of the information systems that monitor and control the electrical systems within the microgrid. The Sandia “tabletop” assessment is based on the most recent 20% design packages. From this assessment, the Sandia team identified several security areas that were undefined or did not implement industry best practices. Finally, the Sandia team presented possible follow-on assessment activities and recommended investigating multiple hardening technologies. Addressing these findings and adding state-of-the-art detection and mitigation technologies will help ensure the NJ TRANSITGRID is built with more comprehensive cyber-resilience features.

24 POWER TRANSMISSION AND DISTRIBUTION↗

High-Penetration Microgrids Providing Grid Stability Using Frequency Watt Control

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint. Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

14 SOLAR ENERGY↗

High Penetration Microgrids Providing Grid Stability Using Frequency-Watt Control Presentation

The U.S. grid is rapidly transitioning towards utilizing inverter-based renewable energy resources such as solar, wind, and batteries, reducing the carbon emission footprint.Inverter-based microgrid control architectures remain a critical focus to address power system stability issues in future high penetration markets lacking spinning generation assets. Idaho National Laboratory (INL) is researching an active layered inverter based frequency-Watt control scheme that provides distribution level stability in high-penetration markets where grid inertia is lacking. Hardware in the loop case study was implemented using INL’s Microgrid Testbed to combat scalable frequency deviations ranging from 60 Hz down to 50 Hz initialized by a hydropower model implementing step loads using a 540-kW grid emulator. Our research findings demonstrate the importance of distribution level, inverter-based active frequency-Watt controls utilizing a battery energy storage system (BESS) to provide adequate frequency support at the point of common coupling without major power infrastructure upgrades.

13 HYDRO ENERGY↗

Effects of inflow distortion profiles on fan tone noise calculated using a 3-D theory

Calculations of the fan tone acoustic power and modal structure generated by complex distortions in axial inflow velocity are presented. The model used treats the motor as a rotating three-dimensional cascade and calculates the acoustic field from the distortion-produced dipole distribution on the blades including noncompact source effects. Radial and circumferential distortion shapes are synthesized from Fourier-Bessel components representing individual distortion modes. The relation between individual distortion modes and the generated acoustic modes is examined for particular distortion cases. Comparisons between theoretical and experimental results for distortions produced by wakes from upstream radial rods show that the analysis is a good predictor of acoustic power dependence on disturbance strength.

Kobayashi, H.↗

Effects of inflow distortion profiles on fan tone noise calculated using a 3-D theory

Calculations of the fan tone acoustic power and modal structure generated by complex distortions in axial inflow velocity are presented. The model used treats the rotor as a rotating three-dimensional cascade and calculates the acoustic field from the distortion-produced dipole distribution on the blades including noncompact source effects. Radial and circumferential distortion shapes are synthesized from Fourier-Bessel components representing individual distortion modes. The relation between individual distortion modes and the generated acoustic modes is examined for particular distortion cases. Comparisons between theoretical and experimental results for distortions produced by wakes from upstream radial rods show that the analysis is a good predictor of acoustic power dependence on disturbance strength.

Kobayshi, H.↗

Tall Lunar Towers: Systems Analysis of a Lunar-Surface-Assembled Power, Communication, and Navigation Infrastructure

The National Aeronautics and Space Administration (NASA) intends to develop and maintain a human-lunar presence, requiring infrastructure on the Lunar South Pole. To keep pace with the continued growth in cislunar activity, there is national interest in developing a global lunar infrastructure network for power and Communication, Position, Navigation, and Timing (CPNT). Demonstrating autonomous construction capabilities is an infrastructure-enabling objective. This study explores several architecture trade studies to assess the feasibility of alternative lunar infrastructure concepts. 50 m towers, for instance, enable solar power generation up to 99% of a lunar year in addition to acting as wide-range communication and navigation surface relays. The infrastructure network considered in this study consisted of tower platforms, utilities hosted on the towers, and both crewed and robotic end users. High-level trades were analyzed, such as tower height, location, and distributed vs centralized power grids. Results indicated that even with minimal permanent surface assets (darkness survival power loads on the order of 5 kW or greater), at any of the five locations considered, taller towers resulted in lower infrastructure mass than shorter towers; up to 24% system mass savings were realized by reducing battery mass. Simultaneously, taller towers increased the range of communication coverage; a 50 m tower on the Connecting Ridge had 5 kg more structure and 76% more line-of-sight coverage to a two-meter-tall end user than a 10 m tower with the same location and user height. Leveraging a grid of tall towers for nominal power and communication would not only save up to 2,800 kg in battery mass but would be more maintainable and allow users to take advantage of generational upgrades.

lunar infrastructure↗

Operational Resilience of Nuclear-Renewable Integrated-Energy Microgrids

The increasing prevalence and severity of wildfires, severe storms, and cyberattacks is driving the introduction of numerous microgrids to improve resilience locally. While distributed energy resources (DERs), such as small-scale wind and solar photovoltaics with storage, will be major components in future microgrids, today, the majority of microgrids are backed up with fossil-fuel-based generators. Small modular reactors (SMRs) can form synergistic mix with DERs due to their ability to provide baseload and flexible power. The heat produced by SMRs can also fulfill the heating needs of microgrid consumers. This paper discusses an operational scheme based on distributed control of flexible power assets to strengthen the operational resilience of SMR-DER integrated-energy microgrids. A framework is developed to assess the operational resilience of SMR-DER microgrids in terms of system adaptive real-power capacity quantified as a response area metric (RAM). Month-long simulation results are shown with a microgrid developed in a modified Institute of Electrical and Electronics Engineers (IEEE)-30 bus system. The RAM values calculated along the operational simulation reflect the system resilience in real time and can be used to supervise the microgrid operation and reactor’s autonomous control.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Demand Forecasting in the Smart Grid Paradigm: Features and Challenges

Demand forecasting faces challenges that include a large volume of data, increasing number of factors that affect the demand profile, uncertainties in the generation profile of the distributed and renewable generation resources and lack of historical data. A hierarchical demand forecasting framework can incorporate the new technologies, customer behaviors and preferences, and environmental factors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Management of Risk and Uncertainty Through Optimized Co-Operation of Transmission Systems and Microgrids With Responsive Loads (Final Report)

The evolution of the power system to the reliable, efficient and sustainable system of the future will involve development of both demand- and supply-side technology and operations. Ambitious national and state-level goals around the decarbonization of electricity relies on the integration of very high levels of renewable resources, most of which are variable and intermittent. The use of demand response is an ideal approach to counterbalance the intermittency of renewable generation and brings the consumer into the spotlight. Though individual consumers are interconnected at the low-voltage distribution system, these resources are typically modeled as variables at the transmission network level. Demand-side participation cannot be leveraged effectively without explicitly including the distribution system dynamics in the optimization-based wholesale market operations. This project grew from a vision for co-optimized interaction of distribution systems, or microgrids, with the high-voltage transmission system. In this framework, microgrids encompass consumers, distributed renewables and storage. The energy management system of the lower voltage system (distribution or microgrid) can also sell (buy) excess (necessary) energy from the transmission system. Until recently, very little research had been conducted on the co-optimization of these two systems due to computational limitations. However, advances in computational capabilities, and the judicious use of decomposition methods and innovative approximation methods for high-dimension dynamic programming made this goal a viable objective for this project, leading to a fundamental shift in the ability to integrate and fully utilize demand-side resources. To this end, the modeling framework developed introduces a novel co-optimization framework, to include the operations of both the transmission and distribution systems (or microgrids) in operational decision making. This framework was used to analyze renewable and distributed generation along with responsive demand and to compare the capability of co-optimized systems to perform with higher levels of variable renewables. An ideal microgrid is defined as an electric entity capable of operating in both interconnected (with the high-voltage grid) and islanded mode. As such, the microgrid should incorporate generating units (traditional units and intermittent) and if needed, exchange power with the high-voltage grid. The interplay between the microgrid and high-voltage grid motivated the development of the co-optimization approach to ensure efficient performance of the interconnected network. Results show that the use of a bi-level optimization approach is an appropriate structure, capable of co-optimizing a transmission system with multiple distribution systems and microgrids. While increasing the number of connected systems provides increasing flexibility for renewables integration this can also the economic benefits to the low-voltage subsystems with each additional system connected. Comparison of a traditional single-level decision structure with the co-optimization approach illustrates a reduction in overall system cost under co-optimization, while specific cost allocations to transmission and distribution systems are changed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamically robust coordinated set point tracking of distributed DERs at point of common coupling

Low-inertia operation of small-scale power systems, such as a microgrid or a portion of a long feeder, requires careful coordination of the controller performance of the constituting devices. This challenge is exacerbated in microgrids serving the functionalities of a conventional synchronous-based generation unit while comprised of smaller DERs operating mainly interfaced through power electronics converters. This paper builds on the idea of set point modulation and proposes a two-level control strategy that aims to achieve superior performance at the point of common coupling (PCC) of microgrids by combining a local control level with a distributed and coordinated level. Several case studies on both AC and DC systems, the CIGRE low-voltage benchmark system as the AC system and a test DC microgrid, validate the performance of the proposed approach. The real-world applicability of the approach is established via a high-fidelity power hardware-in-the-loop (PHIL) experimental setup and an application case study on grid frequency regulation. The proposed approach enables a microgrid to participate in ancillary service provisions where speed and quality of regulation are critical.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Experimental investigation of plasma flows in open trap with toroidal diverter under ECR discharge

The results of experimental investigations of plasma flows from an open trap with a toroidal diverter are presented. Cold plasma is generated when introducing microwave power under conditions of electron cyclotron resonance (ECR). The radiation is introduced by a waveguide through a vacuum-tight ceramic window across the axis of the device. By means of the Langmuir probes, the spatial distributions of plasma parameters are measured. The highest density is limited to a critical value n{sub c} (∼10{sup 12} cm{sup –3}) for the generator frequency under use. It is found that the temperature and density of the plasma in the trap and in escaping flows are almost independent of the radius when the ECR zone is located near the open-trap confinement region and the density is close to n{sub c}. At the density n < n{sub c}, ring plasma structures, which collapse under the action of a low-frequency instability, are observed near the separatrix. The possible mechanisms of the occurrence of plasma structures and the nature of the plasma streams are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electrocatalytic Hydrogenation of Biomass-Derived Organics: A review

Sustainable energy generation calls for a shift away from centralized, high-temperature, energy-intensive processes to decentralized, low-temperature conversions that can be powered by electricity produced from renewable sources. Electrocatalytic conversion of biomass-derived feedstocks would allow carbon recycling of distributed, energy-poor resources in the absence of sinks and sources of high-grade heat. Selective, efficient electrocatalysts that operate at low temperatures are needed for electrocatalytic hydrogenation (ECH) to upgrade the feedstocks. For effective generation of energy-dense chemicals and fuels, two design criteria must be met: (i) a high H:C ratio via ECH to allow for high-quality fuels and blends, and (ii) a lower O:C ratio in the target molecules via electrochemical decarboxylation/deoxygenation to improve the stability of fuels and chemicals. The goal of this review is to determine whether the following questions have been sufficiently answered in open literature, and if not, what additional information is required: (1) What organic functionalities are accessible for electrocatalytic hydrogenation under a set of reaction conditions? How do substitutions and functionalities impact the activity and selectivity of ECH? (2) What material properties cause an electrocatalyst to be active for ECH? Can general trends in ECH be formulated based on the type of electrocatalyst? (3) What is the impact of reaction (electrolyte concentration, pH, operating potential) and reactor type conditions?

Catalysts, redox reactions, hydrocarbons, Aromatic↗