Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

NREL Pyrheliometer Comparisons: September 24 - October 5, 2018 (NPC-2018)

Accurate measurements of direct normal (beam) solar irradiance from pyrheliometers are important for developing and deploying solar energy conversion systems, improving our understanding of the Earth's energy budget for climate change studies, and for other science and technology applications involving solar flux. Providing these measurements places many demands on the quality system used by the operator of commercially available radiometers. Maintaining accurate radiometer calibrations that are traceable to an international standard is the first step in producing research-quality solar irradiance measurements. In 1977, the World Meteorological Organization (WMO) established the World Radiometric Reference (WRR) as the international standard for the measurement of direct normal solar irradiance (Frohlich 1991). The WRR is an internationally recognized, detector-based measurement standard determined by the collective performance of six electrically self-calibrated absolute cavity radiometers comprising the World Standard Group (WSG). Various countries, including the United States, have contributed these specialized radiometers to the Physikalisch-Meteorologisches Observatorium Davos - World Radiation Center (PMOD/WRC) to establish the WSG. As with all measurement systems, Absolute Cavity Radiometers (ASR) are subject to performance changes over time. Therefore, PMOD/WRC in Davos, Switzerland, hosts an International Pyrheliometer Comparison (IPC) for transferring the WRR to participating radiometers quinquennialy by invitation. NREL has represented the U.S. Department of Energy (DOE) in each IPC since 1980. As a result, NREL has developed and maintained a select group of absolute cavity radiometers with direct calibration traceability to the WRR, and uses these reference instruments to calibrate pyrheliometers and pyranometers using the International Organization for Standardization (ISO) 17025 accredited Broadband Outdoor Radiometer Calibration (BORCAL) process (Reda et al. 2008). To fill the gap between each IPC, NREL pyrheliometer comparisons (NPCs) are held annually at the Solar Radiation Research Laboratory (SRRL) in Golden, Colorado. Open to all ACR owners and operators, each NPC provides an opportunity to determine the unique WRR transfer factor (WRR-TF) for each participating pyrheliometer. By adjusting all subsequent pyrheliometer measurements by the appropriate WRR-TF, the solar irradiance data are traceable to the WRR. NPC-2018 was September 24 through October 5, 2018. Participants operated 43 ACRs to simultaneously measure clear-sky direct normal solar irradiance during this period. The Transfer Standard Group (TSG) of reference radiometers for NPC-2018 consisted of four NREL radiometers with direct traceability to the WRR, having participated in the Twelfth International Pyrheliometer Comparisons (IPC-XII) in the fall of 2015. As a result of NPC-2018, each participating absolute cavity radiometer was assigned a new WRR-TF, computed as the reference irradiance determined by the TSG divided by the observed irradiance from the participating radiometer. The performance of the TSG during NPC-2018 was consistent with previous comparisons, including IPC-XII. The measurement performance of the TSG allowed the transfer of the WRR to each participating radiometer with an estimated uncertainty of plus/minus 0.36% with respect to the International System of Units.

14 SOLAR ENERGY↗

NREL Comparison Between Absolute Cavity Pyrgeometers and Pyrgeometers Traceable to World Infrared Standard Group and the InfraRed Integrating Sphere

The comparison of the Absolute Cavity Pyrgeometers (ACPs) Comparison with a PIR Pyrgeometer Traceable to the World Infrared Standard Group (WISG) and a Kipp & Zonen (KZ) pyrgeometer traceable to the InfraRed Integrating Sphere Radiometer (IRIS) was held during the NREL Pyrheliometer Comparison (NPC-2018) from September 24 to October 5, 2018. Data from all instruments was collected during night time clear sky conditions only. The irradiance measured by the ACPs and the PIR pyrgeometer traceable to the WISG were collected every 10 seconds during the ACPs self-calibration and every 30 seconds during the measurement runs. The measurement runs were for two hours while the calibration runs were for 6 minutes. The irradiance measured by the Kipp & Zonen pyrgeometer was collected every 30 seconds. During the comparison the average (av) irradiance difference measured by three ACPs varied from 0.2 W/m 2 to -0.5 W/m 2 , with a standard deviation (sd) from 0.5 W/m 2 to 0.8 W/m 2 . The average irradiance difference measured by the three ACPs minus the irradiance measured by the PIR is 4.3 W/m 2 and sd 4.2 W/m 2 , and that of measured irradiance by the KZ is 2.3 W/m 2 and sd 3.5 W/m 2 .

14 SOLAR ENERGY↗

Advanced Inverter Voltage Controls: Simulation and Field Pilot Findings

This report describes work performed by the Hawaiian Electric Companies and the National Renewable Energy Laboratory (NREL) to model and simulate advanced inverter grid-support functions and to validate and expand on those simulations through a field pilot study. This work builds on earlier research, referred to as the Voltage Regulation Operational Strategies study. The objective of both is to investigate functionalities available in most photovoltaic (PV) inverters to modulate active and reactive power autonomously based on local voltage measurements for the purpose of mitigating off-nominal grid voltage conditions. Specifically of interest are volt/volt-ampere reactive (VAR) control and volt/watt control, the effect of those functions on quasi-steady-state feeder voltages, and the impact of the functions on PV energy production. Because volt/VAR and volt/watt control autonomously adjust inverter output based on local conditions without requiring communication with any other devices, they are good candidates to increase PV hosting capacity when it is limited by voltage constraints in a feeder with very large numbers of PV systems.

14 SOLAR ENERGY↗

FY2018 PV Lifetime Annual Report (Final Project Report)

Started in 2016, the PV Lifetime Project is measuring PV module and system degradation profiles over time with the aim of distinguishing different module types and technology. Outdoor energy monitoring in different climates is supplemented with regular testing under repeatable test conditions indoors. The focus is on the PV module, as well as other hardware components (junction boxes, bypass diodes, and module-level electronics) attached to it. Hardware is installed at Sandia National Laboratories in New Mexico, at the National Renewable Energy Laboratory in Colorado, and at the University of Central Florida. The systems are continuously monitored for DC current and voltage, as well as periodic I-V curves at the string level. In the future, once degradation trends have been identified with more certainty, results will be made available to the public online. This data is expected to enable an increase in the accuracy and precision of degradation profiles used in yield assessments that support investments made in new PV plants. Current practice is to assume that degradation is constant over the life of the system. Forthcoming results in the next few years will help to determine whether this assumption is still appropriate.

14 SOLAR ENERGY↗

Widespread Loss of Communications in Grid Systems: Impacts and Response Strategies

This report explores the reliance on communication systems for bulk grid operations and considers selected options as a supplement to cyber security. The extreme scenario of a complete loss of communications for power grid operation is assessed, presenting a bounded, worst-case perspective. The paper explores grid communications failures and how a system modifications can, at an increased cost, retain a moderate level of preparedness for a loss of communications and control when used in partnership with cyber security protocols. Doing so allows the increased economic and secure operation that communication based controls affords, but also ensures a level of resilient operation if they are lost. The motivation of this paper is due to the proliferation of photovoltaic (PV) resources, and more generally, smart-grid resources within the US grid, which are requiring more and more active and wide-area controls. Though the loss of communication and control can affect nearly any grid control system, the risk of losing load at large scales requires a broad view of system interconnectivity, so it has been evaluated from a transmission perspective in this report.

14 SOLAR ENERGY↗

Evaluation of Multi-Inverter Anti-Islanding with Grid Support and Ride-Through and Investigation of Island Detection Alternatives

As utility interconnected photovoltaic systems (PV) become integrated into the electrical power system (EPS) at an increasing rate, utilities and regulators have become concerned about the potential for increased voltage and frequency deviations as well as EPS reliability and resiliency. These concerns have initiated the need to amend the utility interconnection standard to allow advanced inverter control functionalities that provide: (1) reactive power control for voltage support, (2) real (active) power control for frequency support and (3) voltage and frequency ride- through for bulk system support. The new real and reactive power modulation are intended to reduce EPS voltage and frequency deviations by mimicking the droop and excitation controls of conventional generation. The new ride-through capabilities are needed to prevent a large quantity of generation from autonomously de-energizing or disconnecting in response to a voltage or frequency deviation. These changes, however, may have the potential to interfere with autonomous anti-islanding, especially when multiple inverters from different vendors are co-located on one bus. This report presents results from an investigation of multi-inverter autonomous anti- islanding with advanced functions, and the development of a means to mitigate adverse interaction between the two.

14 SOLAR ENERGY↗

Highly Accurate Method for Real-Time Active Power Reserve Estimation for Utility-Scale Photovoltaic Power Plants

This paper applies a robust technique for determining the available power from a curtailed utility-scale photovoltaic (PV) power plant. The proposed technique does not require deploying any additional equipment or sensors and is based only on the addition of new control logic to the existing power plant controller. Also, the proposed method is universally applicable to PV plants with any type of smart inverters and PV modules. Accurate determination of available power is important for using curtailed PV generation as a resource for various types of active power controls, such as spinning reserves and primary and secondary frequency control. For PV plants to be able to maintain the desired regulation range, the plant controller must be able to estimate the available aggregate peak power that all the plant's inverters can produce at any point in time and ensure that the control error stays within the tolerance band at all times. In this paper, we explore a highly accurate control method that uses dedicated inverters within the plant as reference units and evaluates the available aggregate peak power for the whole plant under different cloud variability conditions.

14 SOLAR ENERGY↗

Accelerating Systems Integration Standards (ACCEL)

This is the final report for a project to support the development of systems integration standards. The scope of work undertaken by the multi-laboratory team was to facilitate standards development and to help expedite the process in three important standards identified under the SunShot National Laboratory Multiyear Partnership (SuNLaMP) grid performance and reliability topic area.

14 SOLAR ENERGY↗

PV Variability at the DeSoto Next Generation Solar Energy Center (Cooperative Research and Development Final Report, CRADA Number CRD-11-425)

In order to support the continued integration of utility-scale solar photovoltaic sites into the Florida transmission system and to further enhance our understanding of the effects of cloud-induced output variability on the site and transmission operations, participant elects to enter a Cooperative Research and Development Agreement (CRADA) with the National Renewable Energy Lab (NREL). Under this agreement, NREL will work with participant to instrument their PV plant in DeSoto county FL and obtain solar radiation and power output data. The Florida Power & Light's (FPL) DeSoto Next Generation Energy Center is the largest installed PV plant in the country (25 MW). Our goal is that this site be instrumented and used for research into PV variability and forecasting.

14 SOLAR ENERGY↗

Life-Cycle Cost and Optimization of PV Systems Based on Power Duration Curve with Variable Performance Ratio and Availability

A new derivation of Power Duration Curve is presented and applied to analysis of photovoltaic system life cycle cost. The effect of non-unity Performance Ratio and non-unity Availability on the power duration curve are illustrated. The effect of these two key performance indicators on calculation of life cycle cost and PV system design optimization (optimal DC/AC ratio) are illustrated as example applications of the method.

14 SOLAR ENERGY↗

Performance of Photovoltaic Systems Recorded by Open Solar Performance and Reliability Clearinghouse (oSPARC)

This article analyzes data from 2,200 photovoltaic systems collected through the Open Solar Performance and Reliability Clearinghouse (oSPARC, 2018) to draw conclusions about the measured performance of the systems, how it compares to expectations, and how wide the variation is. The systems range in size from 2 kW to 1,200 kW, with an average size of 229 kW, and were activated in oSPARC between March 13, 2007 and Dec. 16, 2016. Data regarding co-incident insolation and ambient temperature are provided through the oSPARC platform for the population of systems and summarized here. Results indicate that - after correcting for measured insolation, derating for temperature, and correcting for balance-of-system efficiency and degradation as a result of system age - the performance ratio of these 2,200 systems averages 91.7%. Adjusting for known parameters such as age and efficiency, the ratio would ideally be 100%. Thus, the 'underperformance' of this system sample is measured at 9.3% and suggests that as much as 9.3% could be recovered if the systems were caused to perform as expected through optimal operation and maintenance. Efforts to correlate the performance ratio with environmental conditions resulted in very low coefficients of regression, but the method already normalizes for actual site insolation and temperature, which are responsible for much of the site-specific variation. An exemption is air-quality nonattainment areas, where the measured performance of plants averages 86.9% and is consistently lower than the average of 95.9% in areas that are in compliance with air quality standards, likely because of particulate matter such as diesel soot exacerbating the soiling rate.

14 SOLAR ENERGY↗

Global Perspective of Energy Storage (2019 Annual Peer Review Report)

This report provides information about the DOE Office of Electricity Energy Storage Peer Review held in 2019 and includes posters reviewed in these categories: postdoctoral, validated reliability and safety performance, equitable regulatory environment and analytics, applied materials (Materials I), power electronics, industry acceptance, partnerships, and Materials I.

13 HYDRO ENERGY↗

Hawaiian Electric Companies Demand Response Tool

This document introduces the Hawaiian Electric Companies Demand Response Tool, which was developed at the Pacific Northwest National Laboratory. The battery storage evaluation tool by PNNL was modified to run one-year simulations that evaluate the benefits of behind-the-meter behind-the-meter photovoltaics and storage from the customer perspective, while optimizing use of these assets to minimize customer energy bills and improve reliability.

14 SOLAR ENERGY↗

Cybersecurity in Photovoltaic Plant Operations

This paper provides practical information for PV plant operators regarding cybersecurity. Plans to integrate photovoltaic generation into utility systems requires that cybersecurity be considered in every aspect- from customer data to business information to plant monitoring and control operations. This paper describes the types of threats encountered in operation of PV plants; challenges faced by photovoltaic plant operators in implementing cybersecurity; cybersecurity standards that apply to photovoltaic plant operations; cybersecurity response plans and recommended best practices to ensure photovoltaic plant cybersecurity.

14 SOLAR ENERGY↗

Evaluating Utility-Scale PV-Battery Hybrids in an Operational Model for the Bulk Power System

Systems that combine solar photovoltaic and battery energy storage technologies (PV-BES) are increasingly being proposed and deployed on the bulk power system. The operations and value of PV-BES systems have been extensively studied from the project developer's perspective through analyses that maximize plant-level revenue. However, PV-BES hybrids' operational characteristics are seldom studied from the perspective of bulk power system operators, who seek to optimize the performance of a suite of generation and storage assets that are connected via the transmission network. This work presents modeling approaches for representing and evaluating PV-BES hybrids in a model that optimizes operations across the bulk power system. Its novel contributions include demonstrating a technique to modify a unit commitment and dispatch model to represent the operational synergies of PV-BES hybrids. In particular, we describe the challenges and an approach for representing so-called DC-coupled PV-BES - which utilize a single bi-directional inverter - as a dispatchable resource in a commercial, production cost model (PCM), PLEXOS. We demonstrate this technique in a PCM study of the Los Angeles Department of Water and Power (LADWP) test system, by replacing existing PV and battery generators on the test system with our PV-BES hybrids. We then pursue scenario analysis that is designed to isolate the various drivers of operational strategies for DC-coupled PV-BES hybrids, including the nature of coupling, PV penetration on the system, and varying inverter loading ratios (or degrees of over-sizing of the PV field). Results from the analysis include utilization profiles for the PV DC energy across available pathways, dispatch profiles for the battery component, and the hybrid technologies' impacts on system-wide production costs. The approach presented in this paper can be used in any PCM that is looking to study PV-BES hybrids as a resource in different power system configurations and services.

14 SOLAR ENERGY↗

Open Source Fault-tolerant Grid Frequency Measurement for Solar Inverters

The Discrete Fourier transform (DFT) based measurement algorithms are one of the most common measurement algorithms for grid parameter estimation such as rms, phase angle, frequency. Over the past few years, many DFT based algorithms have been developed to enhance its measurement accuracy under steady-state and/or dynamic grid conditions. For example, an adaptive band-pass filter utilizing exponential modulation filter has been proposed to reduce measurement errors at the presence of large frequency deviations. Measurement accuracy of different algorithms including FIR filter, extended Kalman filtering (EKF), and enhanced DFT method have been compared in detail under different grid conditions. Two artificial signals that have 90-degree phase difference were constructed by the Clarke transformation to address the frequency spectrum leakage of DFT. A multi-module approach was developed to enhance both steady-state and dynamic measurement accuracies, in which each module was developed to eliminate some specific errors. Besides DFT-based measurement algorithms, some signal model-based algorithms have been developed to further improve the accuracy under dynamic conditions. However, a key drawback of the state-of-the-art algorithms is that they cannot perform measurements accurately during system transient faults. In the Blue Cut Fire event, there was a phase angle jump of about 26 degrees in the voltage waveform during the transient fault. The phase angle jump fault will cause waveform discontinuity, and these algorithms will fail to provide reliable measurements during this period because they typically assume the waveform to be measured is continuous, no matter what method (DFT, PLL, EKF, FIR, or Taylor WLS) is used for estimation. In fact, the measurement errors during the system transient faults like phase-jump is not required in the IEEE Standard. As a result, although a measurement instrument can pass the strict IEEE Standard, it could still be the source of the problem in the future if we have similar system transient faults, which could happen again. Therefore, developing the fault-tolerant measurement technology is the key to solve the problem.

14 SOLAR ENERGY↗

Solar-to-Grid: Trends in System Impacts, Reliability, and Market Value in the United States with Data Through 2020

With continued deployment of solar across the United States, assessing the interactions of solar with the power system is an increasingly important complement to studies tracking the cost and performance of solar plants. This project focuses on the historical contribution to reliability, trends in market value, and impacts on the bulk power system of solar deployed in the U.S. through the end of 2020. The scope of this analysis includes the seven organized U.S. wholesale power markets and is based on historical hourly solar generation profiles for each individual plant larger than 1 MW or county-level aggregate profiles for smaller solar. In addition, we present a limited set of results for ten utilities that are outside of the independent system operator (ISO)/regional transmission organization (RTO) markets.

14 SOLAR ENERGY↗

Understanding Solar Photovoltaic System Performance: An Assessment of 75 Federal Photovoltaic Systems

This report presents a performance analysis of 75 photovoltaic systems based on PV system production data collected as part of a FEMP Federal PV Performance Assessment project combined with co-incident insolation, and ambient temperature to analyze how actual performance compares with a performance model. FEMP collaborated with 17 Federal agencies and sub-agencies to collect the information required to analyze the performance of each system. The systems represent a total capacity of 30,714 kW and range in size from 1 kW to 4,043 kW, with an average size of 410 kW, and were installed between 2011 and 2020. The data is analyzed for Key Performance Indicators, Availability, Performance Ratio and Energy Ratio by comparing the measured production data to model production data. The System Advisor Model (SAM) combines a description of the system (such as inverter capacity, de-rating for temperature, balance-of-system efficiency) with environmental parameters (coincident solar and temperature data) to calculate predicted performance. The performance metrics are calculated by lining up the measured production data with the model estimate on an hour-by-hour, day-by-day, or month-by-month basis (depending on the interval resolution of the production data). A report with system description, photo of the system, special assumptions made for the site, graph of measured production and model production, table of key performance indicators, and links to O&M resources that might improve performance was produced and delivered to site and agency staff with a short on-line briefing.

14 SOLAR ENERGY↗