Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROMAGNETIC INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Resonator-quantum well infrared photodetectors

We applied a recent electromagnetic model to design the resonator-quantum well infrared photodetector (R-QWIP). In this design, we used an array of rings as diffractive elements to diffract normal incident light into parallel propagation and used the pixel volume as a resonator to intensify the diffracted light. With a proper pixel size, the detector resonates at certain optical wavelengths and thus yields a high quantum efficiency (QE). To test this detector concept, we fabricated a number of R-QWIPs with different quantum well materials and detector geometries. The experimental result agrees satisfactorily with the prediction, and the highest QE achieved is 71%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SEARCH FOR VERY HIGH ENERGY GAMMA-RAY EMISSION FROM PULSAR-PULSAR WIND NEBULA SYSTEMS WITH THE MAGIC TELESCOPE

The MAGIC collaboration has searched for high-energy gamma-ray emission of some of the most promising pulsar candidates above an energy threshold of 50 GeV, an energy not reachable up to now by other ground-based instruments. Neither pulsed nor steady gamma-ray emission has been observed at energies of 100 GeV from the classical radio pulsars PSR J0205+6449 and PSR J2229+6114 (and their nebulae 3C58 and Boomerang, respectively) and the millisecond pulsar PSR J0218+4232. Here, we present the flux upper limits for these sources and discuss their implications in the context of current model predictions.

79 ASTRONOMY AND ASTROPHYSICS↗

Performance of electron reconstruction and selection with the CMS detector in proton-proton collisions at √s = 8 TeV

The performance and strategies used in electron reconstruction and selection at CMS are presented based on data corresponding to an integrated luminosity of 19.7 fb -1 , collected in proton-proton collisions at √s = 8 TeV at the CERN LHC. The paper focuses on prompt isolated electrons with transverse momenta ranging from about 5 to a few 100 GeV. A detailed description is given of the algorithms used to cluster energy in the electromagnetic calorimeter and to reconstruct electron trajectories in the tracker. The electron momentum is estimated by combining the energy measurement in the calorimeter with the momentum measurement in the tracker. Benchmark selection criteria are presented, and their performances assessed using Z, Υ, and J/ψ decays into e + + e - pairs. The spectra of the observables relevant to electron reconstruction and selection as well as their global efficiencies are well reproduced by Monte Carlo simulations. The momentum scale is calibrated with an uncertainty smaller than 0.3%. The momentum resolution for electrons produced in Z boson decays ranges from 1.7 to 4.5%, depending on electron pseudorapidity and energy loss through bremsstrahlung in the detector material.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A RING OF POLARIZED LIGHT: EVIDENCE FOR TWISTED CORONAL MAGNETISM IN CAVITIES

Coronal prominence cavities may be manifestations of twisted or sheared magnetic fields capable of storing the energy required to drive solar eruptions. The Coronal Multi-Channel Polarimeter (CoMP), recently installed at Mauna Loa Solar Observatory, can measure polarimetric signatures of current-carrying magnetohydrodynamic (MHD) systems. For the first time, this instrument offers the capability of daily full-Sun observations of the forbidden lines of Fe XIII with high enough spatial resolution and throughput to measure polarimetric signatures of current-carrying MHD systems. By forward-calculating CoMP observables from analytic MHD models of spheromak-type magnetic flux ropes, we show that a predicted observable for such flux ropes oriented along the line of sight is a bright ring of linear polarization surrounding a region where the linear polarization strength is relatively depleted. We present CoMP observations of a coronal cavity possessing such a polarization ring.

79 ASTRONOMY AND ASTROPHYSICS↗

Investigation of a stripline transmission line structure for gyromagnetic nonlinear transmission line high power microwave sources

A stripline gyromagnetic nonlinear transmission line (NLTL) was constructed out of yttrium iron garnet ferrite and tested at charge voltages of 35 kV–55 kV with bias fields ranging from 10 kA/m to 20 kA/m. Typically, high power gyromagnetic NLTLs are constructed in a coaxial geometry. While this approach has many advantages, including a uniform transverse electromagnetic (TEM) mode, simple interconnection between components, and the ability to use oil or pressurized gas as an insulator, the coaxial implementation suffers from complexity of construction, especially when using a solid insulator. By moving to a simpler transmission line geometry, NLTLs can be constructed more easily and arrayed on a single substrate. This work represents a first step in exploring the suitability of various transmission line structures, such as microstrips and coplanar waveguides. The resulting high power microwave (HPM) source operates in ultra high frequency (UHF) band with an average bandwidth of 40.1% and peak rf power from 2 MW to 12.7 MW.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstruction and Measurement of $\mathcal{O}$(100) MeV Energy Electromagnetic Activity from $\pi^0 \rightarrow \gamma\gamma$ Decays in the MicroBooNE LArTPC

We present results on the reconstruction of electromagnetic (EM) activity from photons produced in charged current νμ interactions with final state π0s. We employ a fully-automated reconstruction chain capable of identifying EM showers of &calO;(100) MeV energy, relying on a combination of traditional reconstruction techniques together with novel machine-learning approaches. These studies demonstrate good energy resolution, and good agreement between data and simulation, relying on the reconstructed invariant π0 mass and other photon distributions for validation. The reconstruction techniques developed are applied to a selection of νμ + Ar → μ + π0 + X candidate events to demonstrate the potential for calorimetric separation of photons from electrons and reconstruction of π0 kinematics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Simulation of Electromagnetic Showers in the ATLAS Calorimeter: Frozen Showers

One of the most time consuming process simulating pp interactions in the ATLAS detector at LHC is the simulation of electromagnetic showers in the calorimeter. In order to speed up the event simulation several parametrisation methods are available in ATLAS. In this paper we present a short description of a frozen shower technique, together with some recent benchmarks and comparison with full simulation. An expected high rate of proton-proton collisions in ATLAS detector at LHC requires large samples of simulated events (Monte Carlo) to study various physics processes. A detailed simulation of particle reactions ('full simulation') in the ATLAS detector is based on GEANT4 and is very accurate. However, due to complexity of the detector, high particle multiplicity and GEANT4 itself, the average CPU time spend to simulate typical QCD event in pp collision is 20 or more minutes for modern computers. During detector simulation the largest time is spend in the calorimeters (up to 70%) most of which is required for electromagnetic particles in the electromagnetic (EM) part of the calorimeters. This is the motivation for fast simulation approaches which reduce the simulation time without affecting the accuracy. Several of fast simulation methods available within the ATLAS simulation framework (standard Athena based simulation program) are discussed here with the focus on the novel frozen shower library (FS) technique. The results obtained with FS are presented here as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Status and evolution of the ESRF beamline ID19

The ESRF synchrotron beamline ID19, dedicated to full-field parallel-beam imaging techniques such as phase-contrast and absorption microtomography and X-ray topography, is one of the most versatile instruments of its kind. This paper presents key characteristics of ID19 in its present form, names examples for research and development performed on the beamline, and outlines the plans for an upgrade on the beamline in coming years, to adapt to the growing needs of the user community. The technical goals envisioned include an increase in available beam size and maximum photon energy, and a substantial increase in flux density for applications using beams of small and intermediate size.

43 PARTICLE ACCELERATORS↗

Direct measurement of {sup 4}He({sup 12}C, {sup 16}O){gamma} reaction near stellar energy

A cross section measurement with a direct {sup 16}O detection method for the reaction energy from E{sub cm} = 2.4 down to 0.7 MeV is planned at Kyushu University Tandem Laboratory (KUTL). To perform the experiment successfully and to get the quantitative information of the cross section within the 10% error, we have newly developed several instruments in 2009, such as a blow-in type windowless gas target and movable slit system placed in the recoil mass separator. By using the windowless blow-in gas target, a pressure of 24 Torr was achieved. The effective thickness along the beam axis was measured by p+{sup 4}He scattering. Thanks to the movable slits installed in a recoil mass separator and the trajectory analysis, we found effective reduction of background conditions from the {sup 12}C beam.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the unexplored period between the dark ages and reionization with observations of the global 21 cm signal

Observations of the frequency dependence of the global brightness temperature of the redshifted 21 cm line of neutral hydrogen may be possible with single dipole experiments. In this paper, we develop a Fisher matrix formalism for calculating the sensitivity of such instruments to the 21 cm signal from reionization and the dark ages. We show that rapid reionization histories with duration {Delta}z < or approx. 2 can be constrained, provided that local foregrounds can be well modeled by low order polynomials. It is then shown that observations in the range {nu}=50-100 MHz can feasibly constrain the Ly{alpha} and x-ray emissivity of the first stars forming at z{approx}15-25, provided that systematic temperature residuals can be controlled to less than 1 mK. Finally, we demonstrate the difficulty of detecting the 21 cm signal from the dark ages before star formation.

79 ASTRONOMY AND ASTROPHYSICS↗

Designing graphene absorption in a multispectral plasmon-enhanced infrared detector

Here, we have examined graphene absorption in a range of graphene-based infrared devices that combine either monolayer or bilayer graphene with three different gate dielectrics. Electromagnetic simulations show that the optical absorption in graphene in these devices, an important factor in a functional graphene-based detector, is strongly dielectric-dependent. Our simulations reveal that plasmonic excitation in graphene can significantly influence the percentage of light absorbed in the entire device, as well as the graphene layer itself, with graphene absorption exceeding 25% in regions where plasmonic excitation occurs. Notably, the dielectric environment of graphene has a dramatic influence on the strength and wavelength range over which the plasmons can be excited, making dielectric choice paramount to final detector tunability and sensitivity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of an AGATA asymmetric detector

Each major technical advance in gamma-ray detection devices has resulted in significant new insights into the structure of atomic nuclei. The next major step in gamma-ray spectroscopy involves achieving the goal of a 4{pi} ball of germanium detectors by using the technique of gamma-ray energy tracking in electrically segmented germanium crystals. The resulting spectrometer will have an unparalleled level of detection power for nuclear electromagnetic radiation. Collaborations have been established in Europe (AGATA)[1] and the USA (GRETA/GRETINA)[2] to build gamma-ray tracking spectrometers. This paper discusses the performance of the first AGATA (Advanced GAmma Tracking Array) asymmetric detector that has been tested at the University of Liverpool. The use of a fully digital data acquisition system has allowed detector charge pulse shapes from a selection of well defined photon interaction positions to be analysed, yielding important information on the position sensitivity of the detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review of Monte Carlo simulations for backgrounds from radioactivity

For all experiments dealing with the rare event searches (neutrino, dark matter, neutrino-less double-beta decay), the reduction of the radioactive background is one of the most important and difficult tasks. There are basically two types of background, electron recoils and nuclear recoils. The electron recoil background is mostly from the gamma rays through the radioactive decay. The nuclear recoil background is from neutrons from spontaneous fission, (α, n) reactions and muoninduced interactions (spallations, photo-nuclear and hadronic interaction). The external gammas and neutrons from the muons and laboratory environment, can be reduced by operating the detector at deep underground laboratories and by placing active or passive shield materials around the detector. The radioactivity of the detector materials also contributes to the background; in order to reduce it a careful screening campaign is mandatory to select highly radio-pure materials. In this review I present the status of current Monte Carlo simulations aimed to estimate and reproduce the background induced by gamma and neutron radioactivity of the materials and the shield of rare event search experiment. For the electromagnetic background a good level of agreement between the data and the MC simulation has been reached by the XENON100 and EDELWEISS experiments, using the GEANT4 toolkit. For the neutron background, a comparison between the yield of neutrons from spontaneous fission and (α, n) obtained with two dedicated softwares, SOURCES-4A and the one developed by Mei-Zhang-Hime, show a good overall agreement, with total yields within a factor 2 difference. The energy spectra from SOURCES-4A are in general smoother, while those from MZH presents sharp peaks. The neutron propagation through various materials has been studied with two MC codes, GEANT4 and MCNPX, showing a reasonably good agreement, inside 50% discrepancy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STEREO QUADRATURE OBSERVATIONS OF THE THREE-DIMENSIONAL STRUCTURE AND DRIVER OF A GLOBAL CORONAL WAVE

We present the first observations of a global coronal wave ('EIT wave') from the two STEREO satellites in quadrature. The wave's initiation site was at the disk center in STEREO-B and precisely on the limb in STEREO-A. These unprecedented observations from the STEREO Extreme Ultraviolet Imaging (EUVI) instruments enable us to gain insight into the wave's kinematics, initiation, and three-dimensional structure. The wave propagates globally over the whole solar hemisphere visible to STEREO-B with a constant velocity of {approx}263 +- 16 km s{sup -1}. From the two STEREO observations, we derive a height of the wave in the range of {approx}80-100 Mm. Comparison of the wave kinematics with the early phase of the erupting coronal mass ejection (CME) structure indicates that the wave is initiated by the CME lateral expansion, and then propagates freely with a velocity close to the fast magnetosonic speed in the quiet solar corona.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimizing the XMaS Beamline for Low energy Operations to Maximize Benefits from the ESRF Upgrade Program

The XMaS beamline at the ESRF has been in regular user operation since April 1998 and operates over an energy range of 2.4-15 keV. It has developed a wide range of unique instrumentation, primarily dedicated to high resolution magnetic and single crystal diffraction. With the upcoming ESRF upgrade program a number of instrumental developments are planned for the beamline to maximize the benefits of the increased photon flux at low energies. Firstly we report on the optimisation of the beamline and its core components. A novel attenuator system which is actuated by fast acting solenoids thereby avoiding problems of gas bursts into the beamline vacuum seen on some commercially available instruments is introduced. Secondly we discuss developments to the low temperature sample environments that have been integrated into the beamline vacuum system, minimizing both air and beryllium absorption. Finally we demonstrate the current capabilities of the beamline by describing preliminary reflectivity measurements that have been made on an [Fe(2ML)Pd(15ML)]x20 multilayer recorded around the Pd L{sub 3} edge using circular polarised light produced from a thin diamond phase plate.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Streaming readout for next generation electron scattering experiments

Current and future experiments at the high-intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard ‘triggered’ data acquisition systems with a new, simplified and outperforming scheme. ‘Streaming readout’ (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper, we report results of the on-beam validation of the Jefferson Lab SRO framework. In this work, we exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.

47 OTHER INSTRUMENTATION↗

Simulation study of energy resolution, position resolution and $\pi^0$-$\gamma$ separation of a sampling electromagnetic calorimeter at high energies

A simulation study of energy resolution, position resolution, and π(0)-γ separation using multivariate methods of a sampling calorimeter is presented. As a realistic example, the geometry of the calorimeter is taken from the design geometry of the Shashlik calorimeter which was considered as a candidate for CMS endcap for the phase II of LHC running. The methods proposed in this paper can be easily adapted to various geometrical layouts of a sampling calorimeter. Energy resolution is studied for different layouts and different absorber-scintillator combinations of the Shashlik detector. It is shown that a boosted decision tree using fine grained information of the calorimeter can perform three times better than a cut-based method for separation of π(0) from γ over a large energy range of 20 GeV–200 GeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Voltage-tunable dual-layer terahertz metamaterials

This paper presents the design, fabrication, and characterization of a real-time voltage-tunable terahertz metamaterial based on microelectromechanical systems and broadside-coupled split-ring resonators. In our metamaterial, the magnetic and electric interactions between the coupled resonators are modulated by a comb-drive actuator, which provides continuous lateral shifting between the coupled resonators by up to 20 μm. For these strongly coupled split-ring resonators, both a symmetric mode and an anti-symmetric mode are observed. With increasing lateral shift, the electromagnetic interactions between the split-ring resonators weaken, resulting in frequency shifting of the resonant modes. Over the entire lateral shift range, the symmetric mode blueshifts by ~60 GHz, and the anti-symmetric mode redshifts by ~50 GHz. The amplitude of the transmission at 1.03 THz is modulated by 74%; moreover, a 180° phase shift is achieved at 1.08 THz. Our tunable metamaterial device has myriad potential applications, including terahertz spatial light modulation, phase modulation, and chemical sensing. Furthermore, the scheme that we have implemented can be scaled to operate at other frequencies, thereby enabling a wide range of distinct applications.

42 ENGINEERING↗