Search NASA⌕ Search

SEARCH · Search NASA

Results for “Engineering Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Phase II Characterization Survey of the USNS Bridge (T-AOE 10), Military Sealift Fleet Support Command, Naval Station, Norfolk, Virginia (Final Report)

In March 2011, the USNS Bridge was deployed off northeastern Honshu, Japan with the carrier USS Ronald Reagan to assist with relief efforts after the 2011 Tōhoku earthquake and tsunami. During that time, the Bridge was exposed to air-borne radioactive materials leaking from the damaged Fukushima I Nuclear Power Plant. The proximity of the Bridge to the air-borne impacted area resulted in the contamination of the ship’s air-handling systems and the associated components, as well as potential contamination of other ship surfaces due to either direct intake/deposition or inadvertent spread from crew/operational activities. Preliminary surveys in the weeks after the event confirmed low-level contamination within the heating, ventilation, and air conditioning (HVAC) ductwork and systems, and engine and other auxiliary air intake systems. Some partial decontamination was performed at that time. In response to the airborne contamination event, Military Sealift Fleet Support Command (MSFSC) contracted Oak Ridge Associated Universities (ORAU), under provisions of the Oak Ridge Institute for Science and Education (ORISE) contract, to assess the radiological condition of the Bridge. Phase I identified contamination within the CPS filters, ventilation systems, miscellaneous equipment, and other suspect locations that could not accessed at that time (ORAU 2011b). Because the Bridge was underway during the characterization, all the potentially impacted systems/spaces could not be investigated. As a result, MSFSC contracted with ORAU to perform Phase II of the characterization, specifically to survey systems/spaces previously inaccessible. During Phase II of the characterization, the ship was in port to perform routine maintenance operations, allowing access to the previously inaccessible systems/spaces.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Geothermal Power and Interconnection: The Economics of Getting to Market

This report provides a baseline description of the transmission issues affecting geothermal technologies. It is intended for geothermal experts in either the private or public sector who are less familiar with how the electricity system operates beyond the geothermal plant. The report begins with a comprehensive overview of the grid, how it is planned, how it is used, and how it is paid for. The report then overlays onto this "big picture" three types of geothermal technologies: conventional hydrothermal systems; emerging technologies such as enhanced engineered geothermal systems (EGS) and geopressured geothermal; and geothermal co-production with existing oil and gas wells. Each category of geothermal technology has its own set of interconnection issues, and these are examined separately for each. The report draws conclusions about each technology’s market affinities as defined by factors related to transmission and distribution infrastructure. It finishes with an assessment of selected markets with known geothermal potential, identifying those that offer the best prospects for near-term commercial development and for demonstration projects.

15 GEOTHERMAL ENERGY↗

Authentication Without Secrets

This work examines a new approach to authentication, which is the most fundamental security primitive that underpins all cyber security protections. Current Internet authentication techniques require the protection of one or more secret keys along with the integrity protection of the algorithms/computations designed to prove possession of the secret without actually revealing it. Protecting a secret requires physical barriers or encryption with yet another secret key. The reason to strive for "Authentication without Secret Keys" is that protecting secrets (even small ones only kept in a small corner of a component or device) is much harder than protecting the integrity of information that is not secret. Promising methods are examined for authentication of components, data, programs, network transactions, and/or individuals. The successful development of authentication without secret keys will enable far more tractable system security engineering for high exposure, high consequence systems by eliminating the need for brittle protection mechanisms to protect secret keys (such as are now protected in smart cards, etc.). This paper is a re-release of SAND2009-7032 with new figures numerous edits.

Pierson, Lyndon G.↗

Critical issues in process control system security : DHS spares project.

The goals of this event are: (1) Discuss the next-generation issues and emerging risks in cyber security for control systems; (2) Review and discuss common control system architectures; (3) Discuss the role of policy, standards, and supply chain issues; (4) Interact to determine the most pertinent risks and most critical areas of the architecture; and (5) Merge feedback from Control System Managers, Engineers, IT, and Auditors.

99 GENERAL AND MISCELLANEOUS↗

Geothermal Power and Interconnection: The Economics of Getting to Market

This report provides a baseline description of the transmission issues affecting geothermal technologies. The report begins with a comprehensive overview of the grid, how it is planned, how it is used, and how it is paid for. The report then overlays onto this 'big picture' three types of geothermal technologies: conventional hydrothermal systems; emerging technologies such as enhanced engineered geothermal systems (EGS) and geopressured geothermal; and geothermal co-production with existing oil and gas wells. Each category of geothermal technology has its own set of interconnection issues, and these are examined separately for each. The report draws conclusions about each technology's market affinities as defined by factors related to transmission and distribution infrastructure. It finishes with an assessment of selected markets with known geothermal potential, identifying those that offer the best prospects for near-term commercial development and for demonstration projects.

03 NATURAL GAS↗

Performance Assessment Program for the Savannah River Site Liquid Waste Facilities - 13610

The Liquid Waste facilities at the U.S. Department of Energy's (DOE) Savannah River Site (SRS) are operated by Liquid Waste Operations contractor Savannah River Remediation LLC (SRR). A separate Performance Assessment (PA) is prepared to support disposal operations at the Saltstone Disposal Facility and closure evaluations for the two liquid waste tank farm facilities at SRS, F-Tank Farm and H-Tank Farm. A PA provides the technical basis and results to be used in subsequent documents to demonstrate compliance with the pertinent requirements identified in operations and closure regulatory guidance. The Saltstone Disposal Facility is subject to a State of South Carolina industrial solid waste landfill permit and the tank farms are subject to a state industrial waste water permit. The three Liquid Waste facilities are also subject to a Federal Facility Agreement approved by the State, DOE and the Environmental Protection Agency (EPA). Due to the regulatory structure, a PA is a key technical document reviewed by the DOE, the State of South Carolina and the EPA. As the waste material disposed of in the Saltstone Disposal Facility and the residual material in the closed tank farms is also subject to reclassification prior to closure via a waste determination pursuant to Section 3116 of the Ronald W. Reagan National Defense Authorization Act of Fiscal Year 2005, the U.S. Nuclear Regulatory Commission (NRC) is also a reviewing agency for the PAs. Pursuant to the Act, the NRC also has a continuing role to monitor disposal actions to assess compliance with stated performance objectives. The Liquid Waste PA program at SRS represents a continual process over the life of the disposal and closure operations. When the need for a PA or PA revision is identified, the first step is to develop a conceptual model to best represent the facility conditions. The conceptual model will include physical dimensions of the closed system, both the engineered and natural system, and modeling input parameters associated with the modeled features, both initial values (at the time of facility closure) and degradation rates/values. During the development of the PA, evaluations are conducted to reflect not only the results associated with the best available information at the time but also to evaluate potential uncertainties and sensitivities associated with the modeled system. While the PA will reflect the modeled system results from the best available information, it will also identify areas for future work to reduce overall PA uncertainties moving forward. DOE requires a PA Maintenance Program such that work continues to reduce model uncertainties, thus bolstering confidence in PA results that support regulatory decisions. This maintenance work may include new Research and Development activities or modeling as informed by previous PA results and other new information that becomes available. As new information becomes available, it is evaluated against previous PAs and appropriate actions are taken to ensure continued confidence in the regulatory decisions. Therefore, the PA program is a continual process that is not just the development of a PA but seeks to incorporate new information to reduce overall model uncertainty and provide continuing confidence in regulatory decisions. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Scientific machine learning for modeling and simulating complex fluids

The formulation of rheological constitutive equations—models that relate internal stresses and deformations in complex fluids—is a critical step in the engineering of systems involving soft materials. While data-driven models provide accessible alternatives to expensive first-principles models and less accurate empirical models in many engineering disciplines, the development of similar models for complex fluids has lagged. The diversity of techniques for characterizing non-Newtonian fluid dynamics creates a challenge for classical machine learning approaches, which require uniformly structured training data. Consequently, early machine-learning based constitutive equations have not been portable between different deformation protocols or mechanical observables. Here, we present a data-driven framework that resolves such issues, allowing rheologists to construct learnable models that incorporate essential physical information, while remaining agnostic to details regarding particular experimental protocols or flow kinematics. These scientific machine learning models incorporate a universal approximator within a materially objective tensorial constitutive framework. By construction, these models respect physical constraints, such as frame-invariance and tensor symmetry, required by continuum mechanics. We demonstrate that this framework facilitates the rapid discovery of accurate constitutive equations from limited data and that the learned models may be used to describe more kinematically complex flows. This inherent flexibility admits the application of these “digital fluid twins” to a range of material systems and engineering problems. We illustrate this flexibility by deploying a trained model within a multidimensional computational fluid dynamics simulation—a task that is not achievable using any previously developed data-driven rheological equation of state.

Science & Technology - Other Topics↗

System Modeling and Building Energy Simulations of Gas Engine Driven Heat Pump

To improve the system performance of a gas engine driven heat pump (GHP) system, an analytical modeling and experimental study has been made by using desiccant system in cooling operation (particularly in high humidity operations) and suction line waste heat recovery to augment heating capacity and efficiency. The performance of overall GHP system has been simulated with a detailed vapor compression heat pump system design model. The modeling includes: (1) GHP cycle without any performance improvements (suction liquid heat exchange and heat recovery) as a baseline (both in cooling and heating mode), (2) the GHP cycle in cooling mode with desiccant system regenerated by waste heat from engine incorporated, (3) GHP cycle in heating mode with heat recovery (recovered heat from engine). According to the system modeling results, by using the desiccant system the sensible heat ratio (SHR- sensible heat ratio) can be lowered to 40%. The waste heat of the gas engine can boost the space heating efficiency by 25% at rated operating conditions. In addtion,using EnergyPlus, building energy simulations have been conducted to assess annual energy consumptions of GHP in sixteen US cities, and the performances are compared to a baseline unit, which has a electrically-driven air conditioner with the seasonal COP of 4.1 for space cooling and a gas funace with 90% fuel efficiency for space heating.

building energy simulation↗

Local imaging of diamagnetism in proximity-coupled niobium nanoisland arrays on gold thin films.

In this work, we study the effect of engineered disorder on the local magnetic response of proximity-coupled superconducting island arrays by comparing scanning superconducting quantum interference device (SQUID) susceptibility measurements to a model in which we treat the system as a network of one-dimensional (1D) superconductor-normal-metal-superconductor Josephson junctions, each with a Josephson coupling energy E-J determined by the junction length or distance between islands. We find that the disordered arrays exhibit a spatially inhomogeneous diamagnetic response which, for low local applied magnetic fields, is well described by this junction network model, and we discuss these results as they relate to inhomogeneous 2D superconductors. Our model of the static magnetic response of the arrays does not fully capture the onset of nonlinearity and dissipation with increasing applied field, as these effects are associated with vortex motion due to the dynamic nature of the scanning SQUID susceptometry measurement. This work demonstrates a model 2D superconducting system with engineered disorder, and it highlights the impact of dissipation on the local magnetic properties of 2D superconductors and Josephson junction arrays.

Bishop-Van Horn, Logan↗

Cyber-Informed Engineering: Incorporating CIE into Engineering Curricula

Cyber-Informed Engineering (CIE) is an engineering approach that mitigates the consequences of cyber risk to critical infrastructure by integrating engineered controls into system design and operation. CIE-focused education is necessary to prepare future engineers and technicians to understand and mitigate digital risk in modern engineered systems. This session explores how universities can incorporate CIE into their curricula, provides examples of how existing universities are already leveraging CIE in their programs, and highlights resources to support adoption.

99 - GENERAL AND MISCELLANEOUS↗

A Bifunctional Pt/CeO 2 -Cu 1 /CeO 2 Catalyst System for Isooctane Oxidation under Fully Simulated Engine-Exhaust Condition: Eliminating the Inhibition by CO

Pt-based catalysts, because of their outstanding activity for hydrocarbon oxidation, are widely used in the engine-exhaust aftertreatment system to remove hydrocarbon emissions. However, the CO and NO x present in real engine exhausts compete with hydrocarbons for active Pt sites, and thus inhibit hydrocarbon oxidation. In this work, we evaluated the inhibition effects of CO and NO on isooctane oxidation over a Pt/CeO 2 catalyst under the simulated condition of the US DRIVE test protocol (S-GDI, stoichiometric gasoline direct injection). We also leveraged a low-cost single-atom Cu 1 /CeO 2 catalyst, which is highly active for low-temperature CO oxidation, to eliminate the inhibition effect of CO. Specifically, by physically mixing Cu 1 /CeO 2 and Pt/CeO 2 , all the CO is completely converted below 200 °C under simulated exhaust condition, which helps lower the isooctane oxidation temperature. However, the unconverted NO still strongly suppresses HC oxidation. Possible strategies to address the NO inhibitor were proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Experimental Study and Model Predictive Control of a Lean-Burn Gasoline Engine Coupled With a Passive Selective Catalytic Reduction System

Lean-burn gasoline engines have reflected 10–20% engine efficiency gain over stoichiometric engines and are widely considered as a promising technology for meeting the 54.5 miles-per-gallon (mpg) corporate average fuel economy standard by 2025. Nonetheless, nitrogen oxides (NO x ) emissions control for lean-burn gasoline for meeting the stringent Environmental Protection Agency tier 3 emission standards has been one of the main challenges toward the commercialization of highly efficient lean-burn gasoline engines in the United States. Passive selective catalytic reduction (SCR) systems, which consist of a three-way catalyst (TWC) and SCR, have demonstrated great potentials of effectively reducing NO x emissions for lean gasoline engines at low cost. Yet, passive SCR operation may cause significant fuel penalty since rich engine combustion is required for ammonia generation. The purpose of this study is to develop a model-predictive control (MPC) scheme for a lean-burn gasoline engine coupled with a passive SCR system to minimize the total equivalent fuel penalty associated with passive SCR operation while satisfying stringent NO x and ammonia (NH 3 ) emissions requirements. Simulation results demonstrate that the MPC approach can reduce the fuel penalty by 43.9% in a simulated US06 cycle and 28.0% in a simulated urban dynamometer driving schedule (UDDS) cycle, respectively, compared to the baseline control, while achieving over 97% DeNO x efficiency and less than 15 ppm tailpipe ammonia slip. The proposed MPC controller can potentially enable highly efficient lean-burn gasoline engines while meeting the stringent Environmental Protection Agency tier 3 emission standards.

33 ADVANCED PROPULSION SYSTEMS↗

Long-term performance of engineered barriers for high-level waste repositories - 15358

The evolution of the engineered barrier system (EBS) of geological repositories for high-level radioactive waste (HLW) and spent fuel (SF) has been the subject of many national and international research programs during recent years. The emphasis of the research activities was on the elaboration of a detailed understanding of the complex coupled thermo-hydro-mechanical and -chemical (THM-C) processes, which are expected to evolve in the early post-closure period in the near field. From the perspective of radiological long-term safety, an in-depth understanding of these coupled processes is of great significance, because the evolution of the EBS during the early post-closure phase may have a non-negligible impact on the safety functions at later stages of the repository's lifetime. Process interactions during the re-saturation phase (heat pulse, gas generation, non-uniform water uptake from the host rock) could impair the homogeneity of the safety-relevant properties in the EBS (e.g. swelling pressure, hydraulic conductivity, diffusivity). The 7. Framework EURATOM PEBS project (long-term Performance of Engineered Barrier Systems) was initiated in 2010 and completed in March 2014. The project aimed at evaluating the sealing and barrier performance of clay-based EBS over time. The project approach included experiments, model development and consideration of the potential impact on long-term safety functions. The specific project aims were to: -deepen the understanding of the THM and THM-C evolution of the EBS system with time, - provide an enhanced quantitative basis for relating the evolutionary behavior to the safety functions, - clarify further the significance of residual uncertainties for long-term performance assessment. It can be concluded that uncertainties in process understanding occurring in the re-saturation period have been better constrained through PEBS studies, thus the uncertainties in the long-term performance of bentonite barriers have been reduced in some areas. Improvements are in the areas of evolution of materials properties and model development and testing at various scales. On-going in-situ experiments in underground research laboratories may play an important role in further confirming bentonite performance over periods of 10 - 20 years. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Modeling Energy Recovery Using Thermoelectric Conversion Integrated with an Organic Rankine Bottoming Cycle

Hot engine exhaust represents a resource that is often rejected to the environment without further utilization. This resource is most prevalent in the transportation sector, but stationary engine-generator systems also typically do not utilize this resource. Engine exhaust is a source of high grade thermal energy that can potentially be utilized by various approaches to produce electricity or to drive heating and cooling systems. This paper describes a model system that employs thermoelectric conversion as a topping cycle integrated with an organic Rankine bottoming cycle for waste heat utilization. This approach is being developed to fully utilize the thermal energy contained in hot exhaust streams. The model is composed of a high temperature heat exchanger which extracts thermal energy for driving the thermoelectric conversion elements. However, substantial sensible heat remains in the exhaust stream after emerging from the heat exchanger. The model incorporates a closely integrated bottoming cycle to utilize this remaining thermal energy in the exhaust stream. The model has many interacting parameters that define combined system quantities such as overall output power, efficiency, and total energy utilization factors. In addition, the model identifies a maximum power operating point for the system. That is, the model can identify the optimal amount of heat to remove from the exhaust flow to run through the thermoelectric elements. Removing too much or too little heat from the exhaust stream in this stage will reduce overall cycle performance. The model has been developed such that heat exchanger UAh values, thermal resistances, ZT values, and multiple thermoelectric elements can be investigated in the context of system operation. The model also has the ability to simultaneously determine the effect of each cycle design parameter on the performance of the overall system, thus giving the ability to utilize as much waste heat as possible. Key analysis results are presented showing the impact of critical design parameters on power output, system performance and inter-relationships between design parameters in governing performance.

30 DIRECT ENERGY CONVERSION↗

Engineering-Scale Integrated Energy System Data Projection Demonstration via the Dynamic Energy Transport and Integration Laboratory

The objective of this study is to demonstrate and validate the Dynamic Energy Transport and Integration Laboratory (DETAIL) preliminary scaling analysis using Modelica language system-code Dymola. The DETAIL preliminary scaling analysis includes a multisystem integral scaling package between thermal-storage and hydrogen-electrolysis systems. To construct the system of scaled equations, dynamical system scaling (DSS) was applied to all governing laws and closure relations associated with the selected integral system. The existing Dymola thermal-energy distribution system (TEDS) facility and high-temperature steam electrolysis (HTSE) facility models in the Idaho National Laboratory HYBRID repository were used to simulate a test case and a corresponding scaled case for integrated system HYBRID demonstration and validation. The DSS projected data based on the test-case simulations and determined scaling ratios were generated and compared with scaled case simulations. The preliminary scaling analysis performance was evaluated, and scaling distortions were investigated based on data magnitude, sequence, and similarity. The results indicated a necessity to change the normalization method for thermal storage generating optimal operating conditions of 261 kW power and mass flow rate of 6.42 kg/s and the possibility of reselecting governing laws for hydrogen electrolysis to improve scaling predictive properties. To enhance system-scaling similarity for TEDS and HTSE, the requirement for scaling validation via physical-facility demonstration was identified.

08 HYDROGEN↗