Search NASA⌕ Search

SEARCH · Search NASA

Results for “Environmental Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

CMIF ECLS system test findings

During 1987 three Space Station integrated Environmental Control and Life Support System (ECLSS) tests were conducted at the Marshall Space Flight Center (MSFC) Core Module Integration Facility (CMIF) as part of the MSFC ECLSS Phase II test program. The three tests ranged in duration from 50 to 150 hours and were conducted inside of the CMIF module simulator. The Phase II partial integrated system test configuration consisted of four regenerative air revitalization subsystems and one regenerative water reclamation subsystem. This paper contains a discussion of results and lessons learned from the Phase II test program. The design of the Phase II test configuration and improvements made throughout the program are detailed. Future plans for the MSFC CMIF test program are provided, including an overview of planned improvements for the Phase III program.

Schunk, Richard G.↗

Suit Port Aft Bulkhead Mockup 2008 Test Results

The Lunar Electric Rover (LER), formerly called the Small Pressurized Rover (SPR), is currently being carried as an integral part of the current Lunar Surface Architectures under consideration in the Constellation program. One element of the LER is the suit port, the means by which the crew performs Extravehicular Activities (EVAs). Two suit port deliverables were produced in fiscal year 2008: an aft bulkhead mockup for functional integrated testing with the 1-G LER mockup and a functional and pressurizable Engineering Unit (EU). This paper focuses on the aft bulkhead mockup test results from Desert Research and Technology Studies (D-RATS) October 2008 testing at Black Point Lava Flow (BPLF), Arizona. Refer to 39th International Conference on Environmental Systems (ICES) for test results of the EU. The suit port aft bulkhead mockup was integrated with the mockup of the LER cabin and chassis. It is located on the aft bulkhead of the LER cabin structure and includes hatches, a locking mechanism, seals, interior and exterior suit don/doff aids, and exterior platforms to accommodate different crewmember heights. A lightweight mockup of the Mark III suit was tested with the suit port aft bulkhead mockup. There are several limitations to the suit port and mockup suits, and results of the suit port evaluation are presented and interpreted within the context of the limitations.

Romig, Barbara A.↗

Finite Element Analysis and Test Results Comparison for the Hybrid Wing Body Center Section Test Article

This report documents the comparison of test measurements and predictive finite element analysis results for a hybrid wing body center section test article. The testing and analysis efforts were part of the Airframe Technology subproject within the NASA Environmentally Responsible Aviation project. Test results include full field displacement measurements obtained from digital image correlation systems and discrete strain measurements obtained using both unidirectional and rosette resistive gauges. Most significant results are presented for the critical five load cases exercised during the test. Final test to failure after inflicting severe damage to the test article is also documented. Overall, good comparison between predicted and actual behavior of the test article is found.

Przekop, Adam↗

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 539: Area 25 and Area 26 Railroad Tracks, Nevada Test Site, Nevada, Revision 0

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 539, Areas 25 and 26 Railroad Tracks, as identified in the Federal Facility Agreement and Consent Order (FFACO). A modification to the FFACOwas approved in May 2010 to transfer the two Railroad Tracks corrective action sites (CASs) from CAU 114 into CAU539. The two CASs are located in Areas 25 and 26 of the Nevada Test Site: • 25-99-21, Area 25 Railroad Tracks • 26-99-05, Area 26 Railroad Tracks This plan provides the methodology for field activities needed to gather the necessary information for closing the two CASs. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of the CAU 539 Railroad Tracks CASs using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for each CAS. The results of the field investigation should support a defensible recommendation that no further corrective action is necessary. If it is determined that complete clean closure cannot be accomplished during the SAFER, then a hold point will have been reached and the Nevada Division of Environmental Protection (NDEP) will be consulted to determine whether the remaining contamination will be closed under the alternative corrective action of closure in place with use restrictions. This will be presented in a closure report that will be prepared and submitted to the NDEP for review and approval. The sites will be investigated based on the data quality objectives (DQOs) developed on December 14, 2009, by representatives of U.S.Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office; Navarro Nevada Environmental Services, LLC (NNES); and National Security Technologies, LLC. The DQO process has been used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for each Railroad Tracks CAS in CAU 539. The following text summarizes the SAFER activities that will support the closure of CAU 539: • Perform site preparation activities (e.g., utilities clearances, radiological surveys). • Collect in situ dose measurements. • Collect environmental samples from designated target populations (e.g., lead bricks) to confirm or disprove the presence of contaminants of concern (COCs) as necessary to supplement existing information. • If no COCs are present at a CAS, establish no further action as the corrective action. • If COCs exist, collect environmental samples from designated target populations (e.g., clean soil adjacent to contaminated soil) and submit for laboratory analyses to define the extent of COC contamination. If a COC is present at a CAS, NNES will consult NDEP to determine the path forward, then either: • Establish clean closure as the corrective action. The material to be remediated will be removed, disposed of as waste, and verification samples will be collected from remaining soil, or • Establish closure in place as the corrective action and implement the appropriate use restrictions.

54 ENVIRONMENTAL SCIENCES↗

Development of thermal control methods for specialized components and scientific instruments at very low temperatures (follow-on)

Many payloads currently proposed to be flown by the space shuttle system require long-duration cooling in the 3 to 200 K temperature range. Common requirements also exist for certain DOD payloads. Parametric design and optimization studies are reported for multistage and diode heat pipe radiator systems designed to operate in this temperature range. Also optimized are ground test systems for two long-life passive thermal control concepts operating under specified space environmental conditions. The ground test systems evaluated are ultimately intended to evolve into flight test qualification prototypes for early shuttle flights.

Wright, J. P.↗

A Hybrid AI/ML and Computational Mechanics Based Approach for Time-Series State and Fatigue Life Estimation of Nuclear Reactor Components

Environmental fatigue modeling is a complex problem due to multiple failure modes and their intermixing. The failure modes are function of various underlying causes in addition to the corrosive effect of reactor coolant environment. Some of the major causes are time-dependence of material associated with cyclic loading, load sequence effect associated with random/variable amplitude loading, effect of strain amplitude and rates, effect of varying temperature (along both temporal and spatial directions) and the effect of mean strain and stress. The nonlinear intermixing of failure modes associated with above mentioned causing parameters makes the environmental fatigue modeling is a challenging task. Because of this challenge, fatigue is traditionally being modeled based on experimental data. However, test based empirical approach often requires hundreds of fatigue tests to model the above-mentioned intermixing failure causes even for a single material system. The problem is further exaggerated for reactor component made from multi-material systems such as made from both carbon and stainless-steel base metals and their similar and dissimilar metal welds. With the difficulty of conducting hundreds of fatigue tests to capture the above-mentioned intermixing failure causes, fatigue modeling approaches often depends on empirical models based on limited available test data such as available through ASME code and NUREG 6909. However, these limited test-data-based models may not be enough to accurately predict the life of reactor components. Accurate prediction of life of reactor component would become a necessity, particularly when the license of the reactors to be extended for long-term-operation (LTO) that is for well beyond its original design life of 40 years. The requirement of extending the license of reactor under LTO requires hundreds of fatigue tests to be conducted to understand the mechanism associated with the above-mentioned interdependent failure causes. However, conducting large number of fatigue tests is not a feasibility due to the cost involved. To address this issues Argonne National Laboratory (ANL) with the sponsorship of DOE Light Water Reactor Sustainability (LWRS) program trying to develop a hybrid predictive modeling approach. This is based on limited experiment-data, Artificial-intelligence (AI) – Machine-Learning (ML) - Deep-Learning (DL) based techniques and Multiphysics-computational-mechanics based modeling tools. The hybrid approach not-only can improve the accuracy of the existing stress analysis and fatigue modeling approach but also can reduce the over-dependency on test-based approach. Towards this goal following are some of the major contributions based on ANL’s FY-20 environmental fatigue modeling activities: 1) A cyclic plasticity material model database for 82/182 dissimilar metal weld, which can be readily shared with US nuclear industry and regulatory agency on request. 2) A well validated analytical modeling methodology to perform cycle-by-cycle stress prediction under both constant amplitude fatigue loading and variable amplitude fatigue loading (with load-sequence effect). 3) An AI/ML/DL based methodology to predict unmeasurable cyclic strain based on other available sensor signals. This type of approach can be used for estimating strain in real reactor components from other sensor readings. 4) An AI/ML based approach to improve the US capability on environmental fatigue testing. This is by improving ANL’s existing environmental fatigue testing capacity to conduct ASME required strain-controlled tests (by controlling strain amplitudes and its rate), while not measuring the strain (due to the difficulty of placing an extensometer in a narrow autoclave in a PWR-water-test system). 5) A simulation and experiment based probabilistic modeling methodology for time-series fatigue state and life estimation of reactor metal such as dissimilar metal weld.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

High Efficiency Room Air Conditioner

This project was undertaken as a CRADA project between UT-Battelle and Geberal Electric Company and was funded by Department of Energy to design and develop of a high efficiency room air conditioner. A number of novel elements were investigated to improve the energy efficiency of a state-of-the-art WAC with base capacity of 10,000 BTU/h. One of the major modifications was made by downgrading its capacity from 10,000 BTU/hr to 8,000 BTU/hr by replacing the original compressor with a lower capacity (8,000 BTU/hr) but high efficiency compressor having an EER of 9.7 as compared with 9.3 of the original compressor. However, all heat exchangers from the original unit were retained to provide higher EER. The other subsequent major modifications included- (i) the AC fan motor was replaced by a brushless high efficiency ECM motor along with its fan housing, (ii) the capillary tube was replaced with a needle valve to better control the refrigerant flow and refrigerant set points, and (iii) the unit was tested with a drop-in environmentally friendly binary mixture of R32 (90% molar concentration)/R125 (10% molar concentration). The WAC was tested in the environmental chambers at ORNL as per the design rating conditions of AHAM/ASHRAE (Outdoor- 95F and 40%RH, Indoor- 80F, 51.5%RH). All these modifications resulted in enhancing the EER of the WAC by up to 25%.

EER↗

Flat-conductor cable baseboard

Report presents procedures and results of test of FCC baseboard system developed for use in commerical and residential applications. Mechanical, electrical, chemical, environmental, thermal, and analytical tests subjected system to conditions of greater severity than would be encountered in normal service; system withstood tests favorably.

Hankins, J. D.↗

Microbial biofilm studies of the environmental control and life support system water recovery test for Space Station Freedom

NASA is developing a water recovery system (WRS) for Space Station Freedom to reclaim human waste water for reuse by astronauts as hygiene or potable water. A water recovery test (WRT) currently in progress investigates the performance of a prototype of the WRS. Analysis of biofilm accumulation, the potential for microbially influenced corrosion (MIC) in the WRT, and studies of iodine disinfection of biofilm are reported. Analysis of WRT components indicated the presence of organic deposits and biofilms in selected tubing. Water samples for the WRT contained acid-producing and sulfate-reducing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples; however, stainless steel corrosion rates were not accelerated. Biofilm iodine sensitivity tests using an experimental laboratory scale recycled water system containing a microbial check valve (MCV) demonstrated that an iodine concentration of 1 to 2 mg/L was ineffective in eliminating microbial biofilm. For complete disinfection, an initial concentration of 16 mg/L was required, which was gradually reduced by the MCV over 4 to 8 hours to 1 to 2 mg/L. This treatment may be useful in controlling biofilm formation.

Rodgers, E. B.↗

Microbial distribution in the Environmental Control and Life Support System water recovery test conducted at NASA, MSFC

NASA/MSFC is developing a physical/chemical treatment system to reclaim wastewater for reuse on Space Station Freedom (SSF). Integrated testing of hygiene and potable water subsystems assessed the capability to reclaim water to SSF specifications. The test was conducted from May through July 1990 with a total of 47 days of system test operation. Water samples were analyzed using standard cultural methods employing membrane filtration and spread plate techniques and epifluorescence microscopy. Fatty acid methyl ester and biochemical profiles were used for microbial identification. Analysis of waste and product water produced by the subsystems demonstrated the effective reduction of viable microbial populations greater than 8.0E + 06 colony forming units (CFU) per 100 mL to an average of 5 CFU/100 mL prior to distribution into storage tanks.

Gauthier, J. J.↗

Microbial biofilm studies of the Environmental Control and Life Support System water recovery test for Space Station Freedom

Analysis of biofilm accumulation, studies of iodine disinfection of biofilm, and the potential for microbially influenced corrosion in the water recovery test (WRT) are presented. The analysis of WRT components showed the presence of biofilms and organic deposits in selected tubing. Water samples from the WRT contained sulfate-reducing and acid-producing organisms implicated in corrosion processes. Corrosion of an aluminum alloy was accelerated in the presence of these water samples, but stainless steel corrosion rates were not accelerated.

Obenhuber, D. C.↗

SWAS Spacecraft T/V Test, Unique In Chamber Tests Systems Actuation

The Sub-Millimeter Wave Astronomy Satellite (SWAS) is the third mission of the Small Explorer (SMEX) Project at Goddard Space Flight Center (GSFC). It is a path finding mission to study the chemical composition of interstellar galactic clouds to help determine the process of star formation. The spacecraft recently completed a month-long then-nal vacuum/thermal balance test in the Solar Environmental Simulator, the largest thermal vacuum facility at Goddard. Rather extensive fixturing was required for the test, considering the small size of the spacecraft, and two unusual deployments were completed in order to accomplish the goals of the test. This paper discusses the space simulation testing of the fully integrated SWAS spacecraft and the unique fixturing required.

Dunn, Jamie L.↗

International Space Station (ISS) Low Pressure Intramodule Quick Disconnect Failures

A failure of an ISS intermodule Quick Disconnect (QD) during protoflight vibration testing of ISS regenerative Environmental Control and Life Support (ECLS) hardware led to the discovery of QD design, manufacturing, and test flaws which can yield the male QD susceptible to failure of the secondary housing seal and inadequate housing assembly locking mechanisms. Discovery of this failure had large implications when considering that currently there are 399 similar units on orbit and approximately 1100 units on the ground integrated into flight hardware. Discovery of the nature of the failure required testing and analysis and implementation of a recovery plan requiring part screening and review of element level and project hazard analysis to determine if secondary seals are required. Implementation also involves coordination with the Nodes and MPLM project offices, Regenerative ECLS Project, ISS Payloads, JAXA, ESA, and ISS Logistics and Maintenance.

Lewis, John F.↗

Characterization of Microbial Communities in Subsurface Nuclear Blast Cavities of the Nevada Test Site

This U.S. Department of Energy (DOE) Environmental Remediation Sciences Project (ERSP) was designed to test fundamental hypotheses concerning the existence and nature of indigenous microbial populations of Nevada Test Site subsurface nuclear test/detonation cavities. Now called Subsurface Biogeochemical Research (SBR), this program’s Exploratory Research (ER) element, which funded this research, is designed to support high risk, high potential reward projects. Here, five cavities (GASCON, CHANCELLOR, NASH, ALEMAN, and ALMENDRO) and one tunnel (U12N) were sampled using bailers or pumps. Molecular and cultivation-based techniques revealed bacterial signatures at five sites (CHANCELLOR may be lifeless). SSU rRNA gene libraries contained diverse and divergent microbial sequences affiliated with known metal- and sulfur-cycling microorganisms, organic compound degraders, microorganisms from deep mines, and bacteria involved in selenate reduction and arsenite oxidation. Close relatives of Desulforudis audaxviator, a microorganism thought to subsist in the terrestrial deep subsurface on H2 and SO42- produced by radiochemical reactions, was detected in the tunnel waters. NTS-specific media formulations were used to culture and quantify nitrate-, sulfate-, iron-reducing, fermentative, and methanogenic microorganisms. Given that redox manipulations mediated by microorganisms can impact the mobility of DOE contaminants, our results should have implications for management strategies at this and other DOE sites.

54 ENVIRONMENTAL SCIENCES↗

Lunar Water Extraction Via Lunar Auger Dryer ISRU (LADI)

In 2009, the Lunar Reconnaissance Orbiter (LRO) and Lunar Crater Observation and Sensing Satellite (LCROSS) provided definitive proof of water in the Lunar’s southern permanently shadowed region (PSR)1. Both the 2020 NASA Technology Taxonomy2 and the Lunar Surface Innovation Initiative (LSII) team identified capability gaps in icy regolith transfer and reactor processing in Permanently Shadowed Region (PSR) environmental conditions. A water processing plant operating inside the PSR can continuously process water (and volatiles) for both breathable air and propellant. NASA’s Johnson Space Center (JSC) fabricated a unique breadboard test stand for validating the feasibility of this concept,developed a lunar auger dryer sizing tool, and identified the physical flow and thermal models required to design an Engineering Development Unit (EDU) for environmental testing. Over the two years this project was active, models were developed including: a) a sizing tool that scales the auger parameters based on production targets, b) accurate thermal models in both lab and lunar conditions, c) a Discreet Element Model (DEM) for observing particle effects in low-g, and d) incorporated these subsystem models into a MATLAB parametric Modular Open System Approach (MOSA) system model. These models were validated by testing the auger in both a mechanical and thermal system configuration. The results of this testing increased the Technology Readiness Level (TRL) of the Lunar Auger Dryer ISRU (LADI) system to TRL 4.

Lunar↗