Search NASA⌕ Search

SEARCH · Search NASA

Results for “Excel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Passivation Mechanisms in Locally Etched P-Type Poly-Si on Silicon Nitride/Silicon Oxide Stack

Tunneling oxide passivated contacts are quickly becoming the industry standard for high-efficiency c-Si based photovoltaic cells. Further development of these structures is essential to enable higher efficiencies and better reliability of cells. By utilizing poly-Si/SixNy/SiOx stacks, very high efficiencies have been demonstrated on small area cells. In this work we investigate the cause of the excellent passivation seen by these structures and show that the primary reason of the excellent passivation seen is the blocking B diffusion to the SiOx/c -Si interface. We also show that the interface between the silicon nitride and polysilicon affects B diffusion through to the c-Si interface. Finally, we demonstrate that the composition of the nitride used is of great importance, and that an incorrect nitride composition leads to B diffusion, and is directly correlated to poor passivation performance.

industries↗

Field Quality and Fabrication Analysis of HQ02 Reconstructed Nb3Sn Coil Cross Sections

© 2017 IEEE. The U.S. LHC Accelerator Research Program (LARP) quadrupole HQ02 was designed and fully tested as part of the low-beta quad development for Hi-Lumi LHC. HQ02's design is well documented with full fabrication accounting along with full field analysis at low and high current. With this history, HQ02 is an excellent test bed for developing a methodology for measuring turn locations from magnet cross sections and comparing with CAD models and measured field. All four coils of HQ02 were cut in identical locations along the magnetic length corresponding to magnetic field measurement and coil metrology. A real-time camera and coordinate measuring equipment was used to plot turn corners. Measurements include systematic and random displacements of winding blocks and individual turns along the magnetic length. The range of cable shifts and the field harmonic range along the length are in agreement, although correlating turn locations and measured harmonics in each cross section is challenging.

Holik, Eddie Frank↗

Test Results of the CERN HL-LHC low- Quadrupole Short Models MQXFS3c and MQXFS4

For the High Luminosity Upgrade of the CERN Large Hadron Collider, lower * quadrupole magnets based on advanced Nb3Sn conductors will be installed on each side of the ATLAS and CMS experiment insertion zones. As part of the technological developments needed to achieve the required field gradient of 132.6 T/m within a 150-mm aperture, short length model magnets, named MQXFS, are tested both at the CERN SM18 and FERMI Lab test facilities. The model magnets rely on two types of Nb3Sn conductors (RRP and PIT) and on an innovative bladders and keys design to provide mechanical support against the Lorentz forces. In 2016 and 2017, the powering tests of the first two models MQXFS3 (RRP) and MQXFS5 (PIT) proved that nominal performance (16.5 kA) could be reached with excellent memory of the quench current after thermal cycle. However both magnets showed a slow training behavior with clear observations of voltage disturbances before the quench. Besides MQXFS5 only could reach ultimate current (17.9 kA) whereas erratic behavior was observed on MQXFS3 due to conductor local degradation at the head of one of the coil. In 2018, this limiting coil was changed and the applied azimuthal pre-stress increased. If ultimate current could then be reached, no stable current could be maintained due to identified defect on the outer layer of the new coil. Finally the outcome of the test of the new model MQXFS4, featuring the final RRP conductors that will be used for the series production and variation on the inner layer quench heater designs are here reported in details.

43 PARTICLE ACCELERATORS↗

Growth of High-Performance Thick Film REBCO Tapes Using Advanced MOCVD

An advanced MOCVD (A-MOCVD) reactor has been used to deposit 4+-µm-thick undoped (Gd,Y)BaCuO tapes in a single pass, with consistent critical current above 1400 A/12 mm and critical current density above 2.6 MA/cm 2 at 77 K, 0 T. The highest self-field critical current over 1660 A/12 mm and critical current density of 3.3 MA/cm 2 are among the best values ever reported in 4+-µm-thick REBCO films. Also, A-MOCVD reactor has been used to grow over 4.5 µm thick, 5 mol% Zr-doped REBCO films, with ~45% precursor-to-film conversion efficiency, which is more than four times higher than that achieved in conventional MOCVD reactors. Excellent in-plane and out-of-plane texture values below 2.35° and 1.25° respectively have been achieved. Furthermore, onset critical temperature (Tc) is in the range of (92.5-93.5) K and transition width (ΔTc) is below 1 K. This remarkable demonstration of growth of 4+-µm- thick doped (Gd,Y)BaCuO films with double deposition rate, 4X improvement in precursor-to-film conversion efficiency and excellent critical current makes A-MOCVD an attractive approach for the manufacturing of low-cost, high-performance superconductor tapes.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cathode Strip Chambers in ATLAS: Installation, Commissioning and in situ Performance

The Muon Spectrometer of the ATLAS detector at the LHC is designed to provide high quality stand-alone muon identification, momentum measurement and trigger capabilities with high pseudorapidity coverage. Precision tracking at the inner-most station in the high pseudorapidity regions, 2.3 < |eta| < 2.7, is performed by 16 four-layered Cathode Strip Chambers on each end-cap. These are multi-wire proportional chambers with segmented cathodes providing excellent spatial resolution and high counting rate capability. The second cathode of each layer is coarsely segmented, providing the transverse coordinate. The detector level performance of the system is presented. The installation and commissioning effort for the Cathode Strip Chambers is described. Finally, the in situ performance is briefly discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Upscaling of asymmetric hollow fiber‐supported thin film membranes for oxygen separation from air: Proof of concept

Abstract Hollow fiber membranes demonstrate various advantages for high performance oxygen separation. However, the small diameters of hollow fibers and the brittleness of ceramics limit their mechanical strength, imposing great difficulties on stack and module development. Gas‐tight sealing is another challenge for upscaling of hollow fiber membrane technology. Low temperature sealant materials of epoxy resin or silicon are typically used for hollow fiber stacks, requiring that the sealing portions be located out of hot zone. Consequently, only partial length of hollow fibers participates in oxygen permeation. In this study, upscaling of our recently developed asymmetric hollow fiber‐supported thin film membranes is conducted, where individual hollow fibers are assembled in parallel to form a stack. A reliable gas‐tight sealing is obtained by combining ceramic paste with conductive adhesive ink cohesively. Comprehensive oxygen permeation test is conducted with the sealing portions being in hot zone and compared with a single hollow fiber membrane. Fundamental mechanism is discussed to understand the performances and their differences. An accelerated long‐term test (∼320 h, 16 thermal cycles) demonstrates excellent stability and robustness of the stack and sealing. The characterization of post‐test samples further confirms excellent stability and robustness of the phases and microstructures of the stack.

36 MATERIALS SCIENCE↗

Systems Modeling of Chemical Hydride Hydrogen Storage Materials for Fuel Cell Applications

A fixed bed reactor was designed, modeled and simulated for hydrogen storage on-board the vehicle for PEM fuel cell applications. Ammonia Borane (AB) was selected by DOE's Hydrogen Storage Engineering Center of Excellence (HSECoE) as the initial chemical hydride of study because of its high hydrogen storage capacity (up to {approx}16% by weight for the release of {approx}2.5 molar equivalents of hydrogen gas) and its stability under typical ambient conditions. The design evaluated consisted of a tank with 8 thermally isolated sections in which H2 flows freely between sections to provide ballast. Heating elements are used to initiate reactions in each section when pressure drops below a specified level in the tank. Reactor models in Excel and COMSOL were developed to demonstrate the proof-of-concept, which was then used to develop systems models in Matlab/Simulink. Experiments and drive cycle simulations showed that the storage system meets thirteen 2010 DOE targets in entirety and the remaining four at greater than 60% of the target.

08 HYDROGEN↗

Ultrasonic Welding of Soft Polymer and Metal: A Preliminary Study

Joining soft polymers and metals is receiving increasing attention in both industry and academia to enable the manufacturing of innovative products. One motivation arises from the production of next-generation heat exchanges, the structure of which is primarily composed of polymers and metals. Waste heat coming from low temperature exhaust gas stream is significant in industries in the U.S. However, traditional heat exchangers that are available to recover heat in the presence of small temperature difference are large and costly, restricting the wide application of such heat exchangers. To address this challenge, a hybrid materials design is proposed to achieve a balance between thermal conductivity and mechanical strength. High quality requirement induced by the changing operating conditions necessitates a strong bonding between polymers and copper. In this research, the possibility of using ultrasonic welding, which is conventionally employed to join dissimilar or similar metal layers, is explored. Preliminary results from welding experiments and tensile shear tests reveal that two bonding modes exist in the welding of PET and copper. Furthermore, analysis of power signals collected during welding shows that one can potentially monitor and optimize welding processes using monitoring signals. It is concluded from this study that ultrasonic welding has excellent potential in joining soft polymers and metals. Future work is also discussed on the process improvement and mechanism investigation.

Meng, Yuquan↗

Electron-beam-evaporated thin films of hafnium dioxide for fabricating electronic devices

Thin films of hafnium dioxide (HfO 2 ) are widely used as the gate oxide in fabricating integrated circuits because of their high dielectric constants. In this paper, the authors report the growth of thin films of HfO 2 using e-beam evaporation, and the fabrication of complementary metal-oxide semiconductor (CMOS) integrated circuits using this HfO 2 thin film as the gate oxide. The authors analyzed the thin films using high-resolution transmission electron microscopy and electron diffraction, thereby demonstrating that the e-beam-evaporation-grown HfO 2 film has a polycrystalline structure and forms an excellent interface with silicon. Accordingly, we fabricated 31-stage CMOS ring oscillator to test the quality of the HfO 2 thin film as the gate oxide, and obtained excellent rail-to-rail oscillation waveforms from it, denoting that the HfO 2 thin film functioned very well as the gate oxide.

42 ENGINEERING↗

Pilot-scale electron cyclotron resonance-metal organic chemical vapor deposition system for the preparation of large-area fluorine-doped SnO{sub 2} thin films

The authors report the surface morphology, optical, electrical, thermal and humidity impacts, and electromagnetic interference properties of fluorine-doped tin oxide (SnO{sub 2}:F or “FTO”) thin films on a flexible polyethylene terephthalate (PET) substrate fabricated by a pilot-scale electron cyclotron resonance–metal organic chemical vapor deposition (PS ECR-MOCVD). The characteristics of large area FTO thin films were compared with a commercially available transparent conductive electrode made of tin-doped indium oxide (ITO), prepared with an identical film and PET thickness of 125 nm and 188 μm, respectively. The results revealed that the as-prepared FTO thin films exhibited comparable performances with the incumbent ITO films, including a high optical transmittance of 97% (substrate-subtracted), low electrical resistivity of about 5 × 10{sup −3} Ω cm, improved electrical and optical performances due to the external thermal and humidity impact, and an excellent shielding effectiveness of electromagnetic interference of nearly 2.3 dB. These excellent performances of the FTO thin films were strongly attributed to the design of the PS ECR-MOCVD, which enabled a uniform plasma environment resulting from a proper mixture of electromagnetic profiles and microwave power.

36 MATERIALS SCIENCE↗

Effect of microstructural evolution on mechanical and tribological properties of Ti-doped DLC films: How was an ultralow friction obtained?

This paper examined the evolution of microstructure and its effect on the mechanical and tribological properties of ultralow friction Ti-doped diamondlike carbon (DLC) films, by adjusting the CH{sub 4}/Ar ratio under constant radio frequency discharge power and bias. The Raman, high resolution transmission electron microscopy, atomic force microscope and nanoindentation measurements consistently reveal or indicate the formation of curved graphene sheets or fullerenelike nanostructures with increasing CH{sub 4}/Ar ratio. The superior frictional performance (0.008–0.01) of Ti-DLC films can be attributed to the special microstructure related to the development of embedded fullerenelike nanostructures as a result of incorporation of TiO{sub 2} clusters. The contributing factors include high hardness and cohesion, excellent toughness, high load-bearing capacity, as well as the ultralow shear resistance transform layer and the excellent antioxidation stability brought by the doped Ti.

36 MATERIALS SCIENCE↗

Linearity Response of Ca2+- Doped CeBr3 as a Function of Gamma-Ray Energy

An aliovalently calcium-doped cerium tribromide (CeBr3:Ca2+) crystal was prepared with a gamma-energy resolution (FWHM) of 3.2% at the 137Cs 662 keV gamma energy. We completed a crystal assessment and calculated the predictive performance and physical characteristics using density functional theory (DFT) formalism. Detector performance, characteristics, calcium doping concentration, and crystal strength are reported. The structural, electronic, and optical properties of CeBr3 crystals were investigated using the DFT within generalized gradient approximation. Specifically, we see excellent linearity of photons per unit energy with the aliovalent CeBr3:Ca2+ crystal. Proportionality of light yield is one area of performance in which Ce-doped and Ce-based lanthanide halides excel. Maintaining proportionality is the key to producing a strong, high-performance scintillator. Relative light yield proportionality was measured for both doped and undoped samples of CeBr3 to ensure no loss in performance was incurred by doping. The light output and proportionality for doped CeBr3, however, appears to be similar to that of undoped CeBr3. The new crystal was subjected to additional testing and evaluation, including a benchmark spectroscopy assessment. Results, which present energy resolution as a function of energy, are summarized. Typical spectroscopy results using a 137Cs radiation source are shown for our crystallites with diameters <1 cm. We obtain energy resolution of 3.2% before packing the crystallite in a sealed detector container and 4.5% after packing. Spectra were also obtained for 241Am, 60Co, 228Th, and background to illustrate the spectrosocopic quality of CeBr3:Ca2+ over a broader energy range.

aliovalent substitution↗

Comparison of MODTRAN5 atmospheric extinction predictions with narrowband astronomical flux observations

Improving the precision of ground-based astronomical observations is an objective of both current (e.g. PanSTARRS1) and future (e.g. Dark Energy Survey and the Large Synoptic Survey Telescope) sky surveys. An important element of this effort is to determine the optical attenuation imposed by the atmosphere. We have obtained atmospheric extinction observations from narrowband photometry (typically 10 nm bandwidth) at central wavelengths of 380 nm, 488 nm, 500 nm, 585 nm, 656 nm, 675 nm and 840 nm. The passbands were selected to measure the continuum component (predominantly from Rayleigh and aerosol scattering) of atmospheric attenuation, and to avoid molecular absorption features in the atmosphere. We compare these atmospheric extinction observations with predictions from MODTRAN5, a commonly used computer model of atmospheric optical transmission. Here, the MODTRAN5 calculations were informed by a satellite-based determination of atmospheric ozone on the night of observations. We also adjusted the MODTRAN5 predictions of Rayleigh scattering to account for the difference between the default pressure and that measured at the observatory on the night of observations. We find excellent agreement across all passbands between the pressureadjusted MODTRAN5 extinction model and the observations, within our typical extinction uncertainty of 0.013 mag/airmass, but only if we exclude any aerosol scattering component in the MODTRAN5 model. Even though this is a very limited test, with observations of a single star for a single night, the fact that we obtain excellent agreement between extinction measurements and the MODTRAN5 model, with no adjustable fit parameters, bodes well for exploiting MODTRAN5 to increase the precision of ground-based flux measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

History and current status of strontium iodide scintillators

Eu-doped strontium iodide single crystal growth has reached maturity and prototype SrI 2 (Eu)-based gamma ray spectrometers provide detection performance advantages over standard detectors. SrI 2 (Eu) offers a high, proportional light yield of >80,000 photons/MeV. Energy resolution of <3% at 662 keV with 1.5” x 1.5” SrI2(Eu) crystals is routinely achieved, by employing either a small taper at the top of the crystal or a digital readout technique. These methods overcome light-trapping, in which scintillation light is re-absorbed and re-emitted in Eu 2+ -doped crystals. As a result, its excellent energy resolution, lack of intrinsic radioactivity or toxicity, and commercial availability make SrI 2 (Eu) the ideal scintillator for use in handheld radioisotope identification devices. A 6-lb SrI 2 (Eu) radioisotope identifier is described.

36 MATERIALS SCIENCE↗

Toward High-Throughput Deposition of III-V Materials and Devices Using Halide Vapor Phase Epitaxy: Preprint

III-V devices are used in countless applications due to their excellent physical properties. They could become more prevalent, especially in area-intensive applications such as solar power, if they can achieve significant cost decreases through increasing scale. The development of high-throughput growth systems can help to achieve this scale, leading to the use of III-V devices in areas where they are not currently economically feasible. Here, we describe a pilot production, pseudo inline HVPE reactor with the potential to greatly increase the throughput of III-V devices. We show computational modeling results that both informed system design and the understanding of the impact of different process parameters on the deposition. We show the throughput possibilities of this reactor with an example solar cell device design but note that this system is agnostic to the device structure and can be used to increase the throughput of lasers, LEDs, transistors, and more III-V devices.

high throughput↗

Fundamentals and application of materials integration for low-power piezoelectrically actuated ultra-nanocrystalline diamond MEMS/NEMS.

Most current micro/nanoelectromechanical systems (MEMS/NEMS) are based on silicon. However, silicon exhibits relatively poor mechanical/tribological properties, compromising applications to several projected MEMS/NEMS devices, particularly those that require materials with high Young's modulus for MEMS resonators or low surface adhesion forces for MEMS/NEMS working in conditions with extensive surface contact. Diamond films with superior mechanical/tribological properties provide an excellent alternative platform material. Ultrananocrystalline diamond (UNCD{cflx W}) in film form with 2-5 nm grains exhibits excellent properties for high-performance MEMS/NEMS devices. Concurrently, piezoelectric Pb(Zr{sub x}Ti{sub 1-x})O{sub 3} (PZT) films provide high sensitivity/low electrical noise for sensing/high-force actuation at relatively low voltages. Therefore, integration of PZT and UNCD films provides a high-performance platform for advanced MEMS/NEMS devices. This paper describes the bases of such integration and demonstration of low voltage piezoactuated hybrid PZT/UNCD cantilevers.

42 ENGINEERING↗

Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Physical and psychophysical characterization of a novel clinical system for digital mammography

Purpose: In recent years, many approaches have been investigated on the development of full-field digital mammography detectors and implemented in practical clinical systems. Some of the most promising techniques are based on flat panel detectors, which, depending on the mechanism involved in the x-ray detection, can be grouped into direct and indirect flat panels. Direct detectors display a better spatial resolution due to the direct conversion of x rays into electron-hole pairs, which do not need an intermediate production of visible light. In these detectors the readout is usually achieved through arrays of thin film transistors (TFTs). However, TFT readout tends to display noise characteristics worse than those from indirect detectors. To address this problem, a novel clinical system for digital mammography has been recently marketed based on direct-conversion detector and optical readout. This unit, named AMULET and manufactured by FUJIFILM, is based on a dual layer of amorphous selenium that acts both as a converter of x rays (first layer) and as an optical switch for the readout of signals (second layer) powered by a line light source. The optical readout is expected to improve the noise characteristics of the detector. The aim is to obtain images with high resolution and low noise, thanks to the combination of optical switching technology and direct conversion with amorphous selenium. In this article, the authors present a characterization of an AMULET system. Methods: The characterization was achieved in terms of physical figures as modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE), and contrast-detail analysis. The clinical unit was tested by exposing it to two different beams: 28 kV Mo/Mo (namely, RQA-M2) and 28 kV W/Rh (namely, W/Rh). Results: MTF values of the system are slightly worse than those recorded from other direct-conversion flat panels but still within the range of those from indirect flat panels: The MTF values of the AMULET system are about 45% and 15% at 5 and 8 lp/mm, respectively. On the other hand, however, AMULET NNPS results are consistently better than those from direct-conversion flat panels (up to two to three times lower) and flat panels based on scintillation phosphors. DQE results lie around 70% when RQA-M2 beams are used and approaches 80% in the case of W/Rh beams. Contrast-detail analysis, when performed by human observers on the AMULET system, results in values better than those published for other full-field digital mammography systems. Conclusions: The novel clinical unit based on direct-conversion detector and optical reading presents great results in terms of both physical and psychophysical characterizations. The good spatial resolution, combined with excellent noise properties, allows the achievement of very good DQE, better than those published for clinical FFDM systems. The psychophysical analysis confirms the excellent behavior of the AMULET unit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗