Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Lunar Science from Lunar Laser Ranging

Variations in rotation and orientation of the Moon are sensitive to solid-body tidal dissipation, dissipation due to relative motion at the fluid-core/solid-mantle boundary, tidal Love number k2, and moment of inertia differences. There is weaker sensitivity to flattening of the core/mantle boundary (CMB) and fluid core moment of inertia. Accurate Lunar Laser Ranging (LLR) measurements of the distance from observatories on the Earth to four retroreflector arrays on the Moon are sensitive to variations in lunar rotation, orientation and tidal displacements. Past solutions using the LLR data have given results for Love numbers plus dissipation due to solid-body tides and fluid core. Detection of the fluid core polar minus equatorial moment of inertia difference due to CMB flattening is weakly significant. This strengthens the case for a fluid lunar core. Future approaches are considered to detect a solid inner core.

Love numbers↗

Enhanced Boiling on Micro-Configured Composite Surfaces Under Microgravity Conditions

Two experimental setups: High Heat Flux Pool Boiling Setup and Optical system of Measuring Contact Angle and Spreading Parameters were established and a series of experiments was conducted. The experimental work on the nucleate boiling performance of both Freon-113 and water on the composite surfaces has been finished and the results show that the composite surface with 25% volume fraction of graphite fibers in the copper matrix has the best enhancing performance. Stronger enhancement was obtained for water compared to Freon-113. The wall superheat initiating boiling was reduced 40% and 35% and the heat flux of the nucleate boiling was augmented up to ten times and 6.7 times, respectively. A bubble departure model has been presented to explain the enhancement mechanism of the boiling heat transfer on the composite surfaces. A powerful optical method to measure contact angle and spreading parameters of liquids on solid surfaces, including both transparent and non-transparent substrates, has been developed and successfully used in the measurements for various liquid-solid systems. The experimental work on identification of profiles near three-phase line by laser shadowgraphy method has been finished and the characteristics of the three-phase line for different liquid-solid systems were unveiled, which is very important to understand the mechanism of boiling under microgravity conditions. The four basic patterns of sessile profile were discovered through caustics and caustic-diffraction analysis by applying wave theory in shadowgraphy technology, which contributes to clearly explain the different characteristics of wetting and spreading of various liquids on a solid surface, and therefore to further understand the bubble departure mechanisms. A new working pattern of heat pipes using working fluids with positive surface-tension gradient against temperature was discovered and analyzed, and then the new heat pipe systems using this kind of working fluids have been presented. Two patent devices, i.e. Shadowgraphic Method to Measure Properties of Sessile Drops and Heat Pipe Systems Using New Working Fluids, have been developed; the former has been approved by The United States Patent & Trademark Office and the latter is being examined.

Source record↗

STEADY COUNTERFLOW HE II HEAT TRANSFER THROUGH POROUS MEDIA

We present steady state counterflow measurements performed on porous samples saturated in He II. The experiment is composed of a vacuum insulated open channel whose top extremity is closed to a Minco registered heater. The temperature and pressure differences across the plug are measured by two germanium TTR-G Microsensors registered thermometers and a Validyne DP10-20 differential pressure sensor. Applied heat fluxes range up to 0.5 kW/m{sup 2} of sample cross section. Measurements were performed at temperatures ranging from 1.7 to 2.1 K on highly anisotropic samples provided by Composite Technology Development Inc.: circular pellets (3.08 mm thick and 28.58 mm in diameter) of 20 compressed layers of pre-impregnated woven magnet insulation. In the laminar regime, the permeability is estimated from the pressure drop measurements for comparison with room temperature data. In the turbulent regime, the model based on tortuosity developed previously fails to describe the heat transfer behavior of He II in this type of porous medium.

42 ENGINEERING↗

The Isolated Synthetic Jet in Crossflow: A Benchmark for Flow Control Simulation

An overview of the data acquisition, reduction, and uncertainty of experimental measurements of the flowfield created by the interaction of an isolated synthetic jet and a turbulent boundary layer is presented. The experimental measurements were undertaken to serve as the second of three computational fluid dynamics validation databases for Active Flow Control. The validation databases were presented at the NASA Langley Research Center Workshop on CFD Validation of Synthetic Jets and Turbulent Separation Control in March, 2004. Detailed measurements were made to document the boundary conditions for the flow and also for the phase-averaged flowfield itself. Three component Laser-Doppler Velocimetry, 2-D Particle Image Velocimetry, and Stereo Particle Image Velocimetry were utilized to document the phase averaged velocity field and the turbulent stresses.

Schaeffler, Norman W.↗

The Isolated Synthetic Jet in Crossflow: A Benchmark for Flow Control Simulation

An overview of the data acquisition, reduction, and uncertainty of experimental measurements made of the flowfield created by the interaction of an isolated synthetic jet and a turbulent boundary layer is presented. The experimental measurements were undertaken to serve as the second of three computational fluid dynamics validation databases for Active Flow Control. The validation databases were presented at the NASA Langley Research Center Workshop on CFD Validation of Synthetic Jets and Turbulent Separation Control in March, 2004. Detailed measurements were made to document the boundary conditions for the flow and also for the phase-averaged flowfield itself. Three component Laser-Doppler Velocimetry, 2-D Particle Image Velocimetry, and Stereo Particle Image Velocimetry were utilized to document the phase-averaged velocity field and the turbulent stresses.

Schaeffler, Norman W.↗

3-D Flow Field Diagnostics and Validation Studies using Stereoscopic Tracking Velocimetry

The measurement of 3-D three-component velocity fields is of great importance in both ground and space experiments for understanding materials processing and fluid physics. Here, we present the investigation results of stereoscopic tracking velocimetry (STV) for measuring 3-D velocity fields. The effort includes diagnostic technology development, experimental velocity measurement, and comparison with analytical and numerical computation. The advantages of STV stems from the system simplicity for building compact hardware and in software efficiency for continual near-real-time process monitoring. It also has illumination flexibility for observing volumetric flow fields from arbitrary directions. STV is based on stereoscopic CCD observations of particles seeded in a flow. Neural networks are used for data analysis. The developed diagnostic tool is tested with a simple directional solidification apparatus using Succinonitrile. The 3-D velocity field in the liquid phase is measured and compared with results from detailed numerical computations. Our theoretical, numerical, and experimental effort has shown STV to be a viable candidate for reliably quantifying the 3-D flow field in materials processing and fluids experiments.

Cha, Soyoung Stephen↗

Cardiovascular response to lower body negative pressure stimulation before, during, and after space flight

BACKGROUND: It is well known that space travel cause post-flight orthostatic hypotension and it was assumed that autonomic cardiovascular control deteriorates in space. Lower body negative pressure (LBNP) was used to assess autonomic function of the cardiovascular system. METHODS: LBNP tests were performed on six crew-members before and on the first days post-flight in a series of three space missions. Additionally, two of the subjects performed LBNP tests in-flight. LBNP mimics fluid distribution of upright posture in a gravity independent way. It causes an artificial sequestration of blood, reduces preload, and filtrates plasma into the lower part of the body. Fluid distribution was assessed by bioelectrical impedance and anthropometric measurements. RESULTS: Heart rate, blood pressure, and total peripheral resistance increased significantly during LBNP experiments in-flight. The decrease in stroke volume, the increased pooling of blood, and the increased filtration of plasma into the lower limbs during LBNP indicated that a plasma volume reduction and a deficit of the interstitial volume of lower limbs rather than a change in cardiovascular control was responsible for the in-flight response. Post-flight LBNP showed no signs of cardiovascular deterioration. The still more pronounced haemodynamic changes during LBNP reflected the expected behaviour of cardiovascular control faced with less intravascular volume. In-flight, the status of an intra-and extravascular fluid deficit increases sympathetic activity, the release of vasoactive substances and consequently blood pressure. Post-flight, blood pressure decreases significantly below pre-flight values after restoration of volume deficits. CONCLUSION: We conclude that the cardiovascular changes in-flight are a consequence of a fluid deficit rather than a consequence of changes in autonomic signal processing.

manned↗

Acoustic gas volume fraction measurement in a multiphase flowing liquid

Apparatus and methods for the measurement of gas volume fraction of produced oil are described. A first method measures the response of a pipe containing the produced oil excited by a source of vibration in the form of an acoustic frequency chirp containing a linearly varying range of frequencies in the tens of kilohertz range encompassing at least one resonant mode of the pipe. As the gas volume fraction increases, the location of the peak maximum of the measured frequency spectrum responsive to the excitation increases in frequency, and the height of the peak maximum increases, thereby permitting a linear calibration curve to be obtained. A second method measures the response of a pipe containing the produced oil to excitation by a continuous source of vibration having a chosen frequency above those which excite flexural vibrations in the pipe and simultaneously excite acoustic waves in the fluid contained in the pipe, known as the coincidence frequency. Gas present in the fluid will interrupt sound propagation or reverberation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe. The amplitude fluctuation level provides a measure of the gas volume present inside the pipe. A third method measures the response of a pipe containing the produced oil to excitation by a high-bandwidth, short pulse having a chosen center frequency above the coincidence frequency. Gas present in the fluid will interrupt pulse propagation, thereby generating fluctuations in the amplitude of the measured vibrations of the pipe.

Sinha, Dipen N.↗

Modeling and simulation of Ultrasonic Guided Waves propagation in the fluid-structure domain by a monolithic approach

The present study introduces the coupled multiphysics model as part of the structural health monitoring (SHM) system. In particular, the Ultrasonic Guided Waves (UGWs) propagation is tracked in order to identify the damage to the structure. For this purpose, a multiphysics mathematical model is proposed. The model constitutes a monolithically coupled system of acoustic and elastic wave equations (WpFSI problem) where the wave signal displacement measurements are analyzed as the UGWs propagates in the solid, fluid and their interface. The ultimate goal of this paper is to explore and develop the efficient numerical solution of the WpFSI problem using the finite element method. A detailed description of the modeling framework and conditions that facilitate the coupling is provided. To couple the displacement-based acoustic wave equations for the isothermal fluid with elastic wave equations for the Saint Venant-Kirchhoff material model, the present study uses a monolithic solution algorithm. In particular, at each time step, wave equations are transformed to a fixed reference configuration via the arbitrary Lagrangian-Eulerian (ALE) mapping and automatically adopt the boundary conditions from the previous time step. The implementation is accomplished via the finite element library deal.II (Goll et al., 2017) based software toolbox DOpElib (Bangerth et al., 2007) which provides modularized higher level algorithms. Beyond SHM systems, the model is relevant for problems from biomechanics and biomedicine, vibromechanics, poroelasticity as well as subsurface and porous media flow. Here, the model developed here serves as a first step towards the on-line SHM system modeling, where structural dynamics are accounted for.

42 ENGINEERING↗

Utilizing a Novel Acoustic Backscatter Array to Characterize Waste Consolidation and Settling in a Horizontal Flow Clarifier - 16051

As part of a collaboration between the University of Leeds, Sellafield Ltd and MMI Engineering Ltd, bespoke acoustic instrumentation and numerical simulation methods have been established to optimize nuclear legacy waste transfers. Specifically, a new ultrasonic measurement system has been developed, allowing suspended particle concentration and consolidation to be measured remotely. This technology has been combined with computational fluid dynamics (CFD) modelling of settling particulate systems, permitting full characterization, simulation and prediction of sludge separation processes. Presented here are experimental and numerical results on the transport and settling behavior of non-active nuclear-analogue suspensions in two flow geometries: gravitational settling of glass dispersions in a 250-liter column; and transport and sedimentation of flocculated calcite in a close-to-full-scale clarifier (9 m{sup 3} total volume and 4.8 m{sup 2} length). In addition, details of the design, construction and calibration of a custom-built Ultrasonic Array Research Platform (UARP) are described. Settling column results suggested that particle concentration changes could be simulated with good accuracy by a CFD model (developed using the open source OpenFOAM framework) when compared to measured samples. Large-scale clarifier trials were used to assess the effectiveness of the UARP controller with an attached in situ acoustic backscatter array (ABA). The ABA consisted of 8 transducers angled down at 20 deg. to the vertical, pulsing at 2-2.5 MHz in cycles (covering 1.8 m total depth). In comparison to a range of sampled concentrations across the length of the clarifier, results confirmed that the UARP-ABA system was highly successful at characterizing these complex flows over several hours of operation, allowing visualization of depth-wise bulk density changes and bed build-up over time. Collectively, this work highlights the capability of these tools to monitor and optimize a number of current waste transfer operations at Sellafield, with further potential applications for solid-liquid separations across waste, water treatment and minerals engineering industries. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Regulation of body fluid volume and electrolyte concentrations in spaceflight

Despite a number of difficulties in performing experiments during weightlessness, a great deal of information has been obtained concerning the effects of spaceflight on the regulation of body fluid and electrolytes. Many paradoxes and questions remain, however. Although body mass, extracellular fluid volume, and plasma volume are reduced during spaceflight and remain so at landing, the changes in total body water are comparatively small. Serum or plasma sodium and osmolality have generally been unchanged or reduced during the spaceflight, and fluid intake is substantially reduced, especially during the first of flight. The diuresis that was predicted to be caused by weightlessness, has only rarely been observed as an increased urine volume. What has been well established by now, is the occurrence of a relative diuresis, where fluid intake decreases more than urine volume does. Urinary excretion of electrolytes has been variable during spaceflight, but retention of fluid and electrolytes at landing has been consistently observed. The glomerular filtration rate was significantly elevated during the SLS missions, and water and electrolyte loading tests have indicated that renal function is altered during readaptation to Earth's gravity. Endocrine control of fluid volumes and electrolyte concentrations may be altered during weightlessness, but levels of hormones in body fluids do not conform to predictions based on early hypotheses. Antidiuretic hormone is not suppressed, though its level is highly variable and its secretion may be affected by space motion sickness and environmental factors. Plasma renin activity and aldosterone are generally elevated at landing, consistent with sodium retention, but inflight levels have been variable. Salt intake may be an important factor influencing the levels of these hormones. The circadian rhythm of cortisol has undoubtedly contributed to its variability, and little is known yet about the influence of spaceflight on circadian rhythms. Atrial natriuretic peptide does not seem to play an important role in the control of natriuresis during spaceflight. Inflight activity of the sympathetic nervous system, assessed by measuring catecholamines and their metabolites and precursors in body fluids, generally seems to be no greater than on Earth, but this system is usually activated at landing. Collaborative experiments on the Mir and the International Space Station should provide more of the data needed from long-term flights, and perhaps help to resolve some of the discrepancies between U.S. and Russian data. The use of alternative methods that are easier to execute during spaceflight, such as collection of saliva instead of blood and urine, should permit more thorough study of circadian rhythms and rapid hormone changes in weightlessness. More investigations of dietary intake of fluid and electrolytes must be performed to understand regulatory processes. Additional hormones that may participate in these processes, such as other natriuretic hormones, should be determined during and after spaceflight. Alterations in body fluid volume and blood electrolyte concentrations during spaceflight have important consequences for readaptation to the 1-G environment. The current assessment of fluid and electrolyte status during weightlessness and at landing and our still incomplete understanding of the processes of adaptation to weightlessness and readaptation to Earth's gravity have resulted in the development of countermeasures that are only partly successful in reducing the postflight orthostatic intolerance experienced by astronauts and cosmonauts. More complete knowledge of these processes can be expected to produce countermeasures that are even more successful, as well as expand our comprehension of the range of adaptability of human physiologic processes.

NASA Discipline Number 18-10↗

Measurements of Pressure Distributions and Force Coefficients in a Squeeze Film Damper. Part 1: Fully Open Ended Configuration

Measurements of pressure distributions and force coefficients were carried out in two types of squeeze film dampers, executing a circular centered orbit, an open-ended configuration, and a partially sealed one, in order to investigate the effect of fluid inertia and cavitation on pressure distributions and force coefficients. Dynamic pressure measurements were carried out for two orbit radii, epsilon 0.5 and 0.8. It was found that the partially sealed configuration was less influenced by fluid inertia than the open ended configuration.

Jung, S. Y.↗

Liquid Acquisition Strategies for Exploration Missions: Current Status 2010

NASA is currently developing the propulsion system concepts for human exploration missions to the lunar surface. The propulsion concepts being investigated are considering the use of cryogenic propellants for the low gravity portion of the mission, that is, the lunar transit, lunar orbit insertion, lunar descent and the rendezvous in lunar orbit with a service module after ascent from the lunar surface. These propulsion concepts will require the vapor free delivery of the cryogenic propellants stored in the propulsion tanks to the exploration vehicles main propulsion system (MPS) engines and reaction control system (RCS) engines. Propellant management devices (PMD s) such as screen channel capillary liquid acquisition devices (LAD s), vanes and sponges currently are used for earth storable propellants in the Space Shuttle Orbiter OMS and RCS applications and spacecraft propulsion applications but only very limited propellant management capability exists for cryogenic propellants. NASA has begun a technology program to develop LAD cryogenic fluid management (CFM) technology through a government in-house ground test program of accurately measuring the bubble point delta-pressure for typical screen samples using LO2, LN2, LH2 and LCH4 as test fluids at various fluid temperatures and pressures. This presentation will document the CFM project s progress to date in concept designs, as well ground testing results.

Chato, David J.↗

Development and application of a standardized flow measurement uncertainty analysis framework to various low-head short-converging intake types across the United States federal hydropower fleet

Turbine discharges at low-head short converging intakes are difficult to measure accurately. The proximity of the measurement section to the intake entrance admits large uncertainties related to asymmetry of the velocity profile, swirl, and turbulence. Existing turbine performance codes [10, 24] do not address this special case and published literature is largely silent on rigorous evaluation of uncertainties associated with this measurement context. The American Society of Mechanical Engineers (ASME) Committee investigated the use of Acoustic transit time (ATT), Acoustic scintillation (AS), and Current meter (CM) in a short converging intake at the Kootenay Canal Generating Station in 2009. Based on their findings, a standardized uncertainty analysis (UA) framework for velocity-area method (specifically for CM measurements) is presented in this paper given the fact that CM is still the most fundamental and common type of measurement system. Typical sources of systematic and random errors associated with CM measurements are investigated, and the major sources of uncertainties associated with turbulence and velocity fluctuations, numerical velocity integration technique (bi-cubic spline), and the number and placement of current meters are being considered for an evaluation. Since the velocity measurements in a short converging intake are associated with complex nonlinear and time varying uncertainties (e.g., Reynolds stress in fluid dynamics), simply applying the law of propagation of uncertainty is known to overestimate the measurement variance while the Monte Carlo method does not. Therefore, a pseudo-Monte Carlo simulation method (random flow generation technique [8]) which was initially developed for the purpose of establishing upstream or initial conditions in the Large-Eddy Simulation (LES) and the Direct Numerical Simulation (DNS) is used to statistically determine uncertainties associated with turbulence and velocity fluctuations. This technique is then combined with a bi-cubic spline interpolation method which converts point velocities into a continuous velocity distribution over the measurement domain. Subsequently the number and placement of current meters are simulated to investigate the accuracy of the estimated flow rates using the numerical velocity-area integration method outlined in ISO 3354 [12]. The authors herein consider that statistics on generated flow rates processed with bi-cubic interpolation and sensor simulations are the combined uncertainties which already accounted for the effects of all those three uncertainty sources. A preliminary analysis based on the current meter data obtained through an upgrade acceptance test of a single unit located in a mainstem plant has been presented.

Smith, Brennan T↗

Techniques for determining total body water using deuterium oxide

The measurement of total body water (TBW) is fundamental to the study of body fluid changes consequent to microgravity exposure or treatment with microgravity countermeasures. Often, the use of radioactive isotopes is prohibited for safety or other reasons. It was selected and implemented for use by some Johnson Space Center (JCS) laboratories, which permitted serial measurements over a 14 day period which was accurate enough to serve as a criterion method for validating new techniques. These requirements resulted in the selection of deuterium oxide dilution as the method of choice for TBW measurement. The development of this technique at JSC is reviewed. The recommended dosage, body fluid sampling techniques, and deuterium assay options are described.

Bishop, Phillip A.↗

Thermal conductivity measurement using modulated photothermal radiometry for nitrate and chloride molten salts

Molten salts are being used or explored for thermal energy storage and conversion systems in concentrating solar power and nuclear power plants. Thermal conductivity of molten salts is an important thermophysical property dictating the performance and cost of these systems, but its accurate measurement has been challenging, as evidenced by wide scattering of existing data in literature. The corrosive and conducting nature of these fluids also leads to time consuming sample preparation processes of many contact-based measurements. Here, in this work, we report the measurement of thermal conductivity of molten salts using a modulated photothermal radiometry (MPR) technique, which is a laser-based, non-contact, frequency-domain method adopted for molten salts for the first time. By unitizing the advantages of front side sensing of frequency-domain measurements and the vertical holder orientation, the technique can minimize the natural convection and salt creeping effects, thus yielding accurate molten salt thermal conductivity . The MPR technique is first calibrated using standard molten materials including paraffin wax and sulfur. It is then applied on measuring pure nitrate salts (NaNO 3 and KNO 3 ), solar salt (NaNO 3 –KNO 3 mixture), and chloride salt (NaCl–KCl–MgCl 2 ). The measurement results are compared with data from literature, especially those obtained from laser flash analysis (LFA). Our results demonstrate that the MPR is a convenient and reliable technique of measuring thermal conductivity of molten salts. Accurate thermal conductivity data of molten salts will be valuable in developing the next-generation high-temperature thermal energy storage and conversion systems.

14 SOLAR ENERGY↗