Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

SEARCHING FOR THE HR 8799 DEBRIS DISK WITH HST /STIS

We present a new algorithm for space telescope high contrast imaging of close-to-face-on planetary disks called Optimized Spatially Filtered (OSFi) normalization. This algorithm is used on HR 8799 Hubble Space Telescope (HST) Space Telescope Imaging Spectrograph (STIS) coronagraphic archival data, showing an over-luminosity after reference star point-spread function (PSF) subtraction that may be from the inner disk and/or planetesimal belt components of this system. The PSF-subtracted radial profiles in two separate epochs from 2011 and 2012 are consistent with one another, and self-subtraction shows no residual in both epochs. We explore a number of possible false-positive scenarios that could explain this residual flux, including telescope breathing, spectral differences between HR 8799 and the reference star, imaging of the known warm inner disk component, OSFi algorithm throughput and consistency with the standard spider normalization HST PSF subtraction technique, and coronagraph misalignment from pointing accuracy. In comparison to another similar STIS data set, we find that the over-luminosity is likely a result of telescope breathing and spectral difference between HR 8799 and the reference star. Thus, assuming a non-detection, we derive upper limits on the HR 8799 dust belt mass in small grains. In this scenario, we find that the flux of these micron-sized dust grains leaving the system due to radiation pressure is small enough to be consistent with measurements of other debris disk halos.

79 ASTRONOMY AND ASTROPHYSICS↗

Evidence of Free-Bound Transitions in Warm Dense Matter and Their Impact on Equation-of-State Measurements

Warm dense matter (WDM) is now routinely created and probed in laboratories around the world, providing unprecedented insights into conditions achieved in stellar atmospheres, planetary interiors, and inertial confinement fusion experiments. However, the interpretation of these experiments is often filtered through models with systematic errors that are difficult to quantify. Due to the simultaneous presence of quantum degeneracy and thermal excitation, transitions in which free electrons are de-excited into thermally unoccupied bound states transferring momentum and energy to a scattered x-ray photon become viable. Here we show that such free-bound transitions are a particular feature of WDM and vanish in the limits of cold and hot temperatures. The inclusion of these transitions into the analysis of recent X-ray Thomson Scattering experiments on WDM at the National Ignition Facility and the Linac Coherent Light Source is required to obtain a physically consistent temperature from the Chihara decomposition. This interpretation is corroborated by agreement with a recently developed model-free thermometry technique and presents an important step for precisely characterizing and understanding the complex WDM state of matter.

Boehme, M [HZDR Dresden]↗

Inverted end-Hall-type low-energy high-current gaseous ion source

A novel approach to low-energy, high-current, gaseous ion beam generation was explored and an ion source based on this technique has been developed. The source utilizes a dc high-current (up to 20 A) gaseous discharge with electron injection into the region of ion generation. Compared to the conventional end-Hall ion source, the locations of the discharge anode and cathode are inverted: the cathode is placed inside the source and the anode outside, and correspondingly, the discharge current is in the opposite direction. The discharge operates in a diverging axial magnetic field, similar to the end-Hall source. Electron generation and injection is accomplished by using an additional arc discharge with a ''cold'' (filamentless) hollow cathode. Low plasma contamination is achieved by using a low discharge voltage (avoidance of sputtering), as well as by a special geometric configuration of the emitter discharge electrodes, thereby filtering (removing) the erosion products stemming from the emitter cathode. The device produces a dc ion flow with energy below 20 eV and current up to 2.5 A onto a collector of 500 cm{sup 2} at 25 cm from the source edge, at a pressure {>=}0.02 Pa and gas flow rate {>=}14 SCCM. The ion energy spread is 2 to 3 eV (rms). The source is characterized by high reliability, low maintenance, and long lifetime. The beam contains less than 0.1% of metallic ions. The specific electric energy consumption is 400 eV per ion registered at the collector. The source operates with noble gases, nitrogen, oxygen, and hydrocarbons. Utilizing biasing, it can be used for plasma sputtering, etching, and other ion technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Radial Heat Flow Apparatus for Thermal Conductivity Characterisation of Cylindrical Samples

During the last two decades, silicon carbide based ceramic composites (SiC/SiC) have become a candidate material for nuclear fuel cladding, first for advanced nuclear systems, such as the GFR, and recently also as potential replacement material for nuclear fuel cladding in light water reactors. This work is contributing to the General Atomics/Westinghouse led CARAT project. In this frame, the thermal conductivity (TC) of cladding prototype sections are measured both before and after neutron irradiation with the purpose of better understanding the effects of neutron irradiation on the pyrolytic carbon interphase linking the SiC fibres to the SiC matrix. To this end, an apparatus has been designed and built to measure the TC of short cylindrical samples, whose lengths range from 5 to 20 cm, by the radial heat flow method. To avoid oxidation issues, the experiments are carried out in vacuum. Today the most common measurement method used to characterise the TC of materials is the so-called laser-flash technique, whereby a short high intensity laser pulse is shot on one surface of a thin flat sample and the energy transfer through the sample is analysed on the other side. Though much faster and easier to implement than the apparatus presented in this work, laser-flash equipment does have issues when dealing with highly anisotropic materials or capturing shape effects such as those present in large aspect ratio samples such as cladding tube sections. The two aforementioned effects are exactly what the developed equipment has been built to capture. The radial heat flow method is based on the principle of measuring the temperature difference building up through a piece of material as this material acts as a thermal resistance against a known heat flow crossing it. This paper presents a new implementation of one of the classical thermal conductivity measurement techniques. Since the development of the laser-flash method in the sixties, steady-state measurements such as the radial heat flow have fallen in disuse. In this discussion, it is shown that a direct measurement method can be used and even be preferable in the case of highly anisotropic materials such as SiC/SiC composites. The advantage of this experimental setup is that the actual transverse conductivity is obtained, whereas laser-flash measurements yield a response in which both the transverse and axial conductivities are mixed. Further steps of this study will include the measurements of samples irradiated with neutrons in the MITR test-reactor. The aim will be to evidence the role played by the pyrolytic carbon interphase by linking the TC measurements with energy filtered electron microscopy. We would like to acknowledge General Atomics and Westinghouse for their support in the frame of the CARAT research program. Providing us with actual prototype clad sections is a unique opportunity. Furthermore the Swiss CCEM.ch project MeAWaT is acknowledged for partially financing the development of the measurement device. (authors)

36 MATERIALS SCIENCE↗

Plasma Spectroscopy in ISTTOK

Plasma spectroscopy is a well established technique for impurities study in fusion plasmas. A brief description of the several spectroscopic systems which have been in operation at ISTTOK is given. In ISTTOK a passive spectroscopy diagnostic system is being used to perform spectral and spatial characterization in the 300-850 nm wavelength range. The system used to perform that work consist essentially of a cooled CCD camera coupled to a half a meter imaging spectrograph with collection optics based on a multi-fiber set to allow for enhanced spatial resolution. Experimental data is shown underlining typical plasma fusion spectral lines and specific ISTTOK characteristics. A web based data access tool is presented that allows the spectral plasma survey in specific wavelength ranges. The information provided by this survey has been used to select suitable transmission filters for a diagnostic, currently under development, to measure Zeff parameter for ISTTOK plasmas. A description of this diagnostic is also presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel flexible framework with automatic feature correspondence optimization for nonrigid registration in radiotherapy

Technical improvements in planning and dose delivery and in verification of patient positioning have substantially widened the therapeutic window for radiation treatment of cancer. However, changes in patient anatomy during the treatment limit the exploitation of these new techniques. To further improve radiation treatments, anatomical changes need to be modeled and accounted for. Nonrigid registration can be used for this purpose. This article describes the design, the implementation, and the validation of a new framework for nonrigid registration for radiotherapy applications. The core of this framework is an improved version of the thin plate spline robust point matching (TPS-RPM) algorithm. The TPS-RPM algorithm estimates a global correspondence and a transformation between the points that represent organs of interest belonging to two image sets. However, the algorithm does not allow for the inclusion of prior knowledge on the correspondence of subset of points, and therefore, it can lead to inconsistent anatomical solutions. In this article TPS-RPM was improved by employing a novel correspondence filter that supports simultaneous registration of multiple structures. The improved method allows for coherent organ registration and for the inclusion of user-defined landmarks, lines, and surfaces inside and outside of structures of interest. A procedure to generate control points from segmented organs is described. The framework parameters r and {lambda}, which control the number of points and the nonrigidness of the transformation, respectively, were optimized for three sites with different degrees of deformation (head and neck, prostate, and cervix) using two cases per site. For the head and neck cases, the salivary glands were manually contoured on CT scans, for the prostate cases the prostate and the vesicles, and for the cervix cases the cervix uterus, the bladder, and the rectum. The transformation error obtained using the best set of parameters was below 1 mm for all the studied cases. The lengths of the deformation vectors were on average ({+-}1 standard deviation) 5.8{+-}2.5 and 2.6{+-}1.1 mm for the head and neck cases, 7.2{+-}4.5 and 8.6{+-}1.9 mm for the prostate cases, and 19.0{+-}11.6 and 14.5{+-}9.3 mm for the cervix cases. Distinguishable anatomical features were identified for each case and were used to validate the registration by calculating residual distances after transformation: 1.5{+-}0.8, 2.3{+-}1.0, and 6.3{+-}2.9 mm for the head and neck, prostate, and cervix sites, respectively. Finally, the authors demonstrated how the inclusion of these anatomical features in the registration process reduced the residual distances to 0.8{+-}0.5, 0.6{+-}0.5, and 1.3{+-}0.7 mm for the head and neck, prostate, and cervix sites, respectively. The inclusion of additional anatomical features produced more anatomically coherent transformations without compromising the transformation error. The authors concluded that the presented nonrigid registration framework is a powerful tool to simultaneously register multiple segmented organs with very different complexities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-DE-BRA-09: Fast Megavoltage CT Imaging with Rapid Scan Time and Low Imaging Dose in Helical Tomotherapy

Purpose: Megavoltage computed tomography (MVCT) imaging has been widely used for daily patient setup with helical tomotherapy (HT). One drawback of MVCT is its very long imaging time, owing to slow couch speed. The purpose of this study was to develop an MVCT imaging method allowing faster couch speeds, and to assess its accuracy for image guidance for HT. Methods: Three cadavers (mimicking closest physiological and physical system of patients) were scanned four times with couch speeds of 1, 2, 3, and 4 mm/s. The resulting MVCT images were reconstructed using an iterative reconstruction (IR) algorithm. The MVCT images were registered with kilovoltage CT images, and the registration errors were compared with the errors with conventional filtered back projection (FBP) algorithm. Moreover, the fast MVCT imaging was tested in three cases of total marrow irradiation as a clinical trial. Results: Three-dimensional registration errors of the MVCT images reconstructed with the IR algorithm were significantly smaller (p < 0.05) than the errors of images reconstructed with the FBP algorithm at fast couch speeds (3, 4 mm/s). The scan time and imaging dose at a speed of 4 mm/s were reduced to 30% of those from a conventional coarse mode scan. For the patient imaging, a limited number of conventional MVCT (1.2 mm/s) and fast MVCT (3 mm/s) reveals acceptable reduced imaging time and dose able to use for anatomical registration. Conclusion: Fast MVCT with IR algorithm maybe clinically feasible alternative for rapid 3D patient localization. This technique may also be useful for calculating daily dose distributions or organ motion analyses in HT treatment over a wide area.

60 APPLIED LIFE SCIENCES↗

A comparison of Raman and pyrometry dynamic temperature measurements of shocked cyclohexane

Optical pyrometry is a well-developed, broadly applicable method to determine temperature in dynamic compression experiments. However, it measures radiation from only the skin depth of the radiant material, is highly susceptible to spurious backgrounds, and requires an often-unmeasurable free parameter—the sample dynamic emissivity. Raman spectroscopy offers a method to determine temperature directly from fundamental theory, but it is practically limited in applications to a small subset of shock experiments. In this work, we describe an experiment allowing simultaneous application of Raman and pyrometric temperature techniques to benchmark a specific instance of pyrometry. We attempted both measurements on multiple experiments and compare the successful temperature results between the separate but highly repeatable shots. Here, we find that dynamic shock temperatures inferred from Raman spectroscopy and pyrometry generally agree within the uncertainties of each measurement, although those uncertainties are larger than typical for a specially designed pyrometry experiment on a shocked metal sample.

74 ATOMIC AND MOLECULAR PHYSICS↗

WE-D-BRD-01: Innovation in Radiation Therapy Delivery: Advanced Digital Linac Features

Last few years has witnessed significant advances in linac technology and therapeutic dose delivery method. Digital linacs equipped with high dose rate FFF beams have been clinically implemented in a number of hospitals. Gated VMAT is becoming increasingly popular in treating tumors affected by respiratory motion. This session is devoted to update the audience with these technical advances and to present our experience in clinically implementing the new linacs and dose delivery methods. Topics to be covered include, technical features of new generation of linacs from different vendors, dosimetric characteristics and clinical need for FFF-beam based IMRT and VMAT, respiration-gated VMAT, the concept and implementation of station parameter optimized radiation therapy (SPORT), beam level imaging and onboard image guidance tools. Emphasis will be on providing fundamental understanding of the new treatment delivery and image guidance strategies, control systems, and the associated dosimetric characteristics. Commissioning and acceptance experience on these new treatment delivery technologies will be reported. Clinical experience and challenges encountered during the process of implementation of the new treatment techniques and future applications of the systems will also be highlighted. Learning Objectives: Present background knowledge of emerging digital linacs and summarize their key geometric and dosimetric features. SPORT as an emerging radiation therapy modality specifically designed to take advantage of digital linacs. Discuss issues related to the acceptance and commissioning of the digital linacs and FFF beams. Describe clinical utility of the new generation of digital linacs and their future applications.

60 APPLIED LIFE SCIENCES↗

Fast Arc Delivery for Stereotactic Body Radiotherapy of Vertebral and Lung Tumors

Purpose: Flattening filter-free (FFF) beams with higher dose rates and faster delivery are now clinically available. The purpose of this planning study was to compare optimized non-FFF and FFF RapidArc plans for stereotactic body radiotherapy (SBRT) and to validate the accuracy of fast arc delivery. Methods and Material: Ten patients with peripheral lung tumors and 10 with vertebral metastases were planned using RapidArc with a flattened 6-MV photon beam and a 10-MV FFF beam for fraction doses of 7.5-18 Gy. Dosimetry of the target and organs at risk (OAR), number of monitor units (MU), and beam delivery times were assessed. GafChromic EBT2 film measurements of FFF plans were performed to compare calculated and delivered dose distributions. Results: No major dosimetric differences were seen between the two delivery techniques. For lung SBRT plans, conformity indices and OAR doses were similar, although the average MU required were higher with FFF plans. For vertebral SBRT, FFF plans provided comparable PTV coverage, with no significant differences in OAR doses. Average beam delivery times were reduced by a factor of up to 2.5, with all FFF fractions deliverable within 4 min. Measured FFF plans showed high agreement with calculated plans, with more than 99% of the area within the region of interest fulfilling the acceptance criterion. Conclusion: The higher dose rate of FFF RapidArc reduces delivery times significantly, without compromising plan quality or accuracy of dose delivery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-38: Patient Organ Specific Dose Assessment in Coronary CT Angiograph Using Voxellaized Volume Dose Index in Monte Carlo Simulation

Purpose: Clinical use of multi detector computed tomography(MDCT) in diagnosis of diseases due to high speed in data acquisition and high spatial resolution is significantly increased. Regarding to the high radiation dose in CT and necessity of patient specific radiation risk assessment, the adoption of new method in the calculation of organ dose is completely required and necessary. In this study by introducing a conversion factor, patient organ dose in thorax region based on CT image data using MC system was calculated. Methods: The geometry of x-ray tube, inherent filter, bow tie filter and collimator were designed using EGSnrc/BEAMnrc MC-system component modules according to GE-Light-speed 64-slices CT-scanner geometry. CT-scan image of patient thorax as a specific phantom was voxellised with 6.25mm3 in voxel and 64×64×20 matrix size. Dose to thorax organ include esophagus, lung, heart, breast, ribs, muscle, spine, spinal cord with imaging technical condition of prospectively-gated-coronary CT-Angiography(PGT) as a step and shoot method, were calculated. Irradiation of patient specific phantom was performed using a dedicated MC-code as DOSXYZnrc with PGT-irradiation model. The ratio of organ dose value calculated in MC-method to the volume CT dose index(CTDIvol) reported by CT-scanner machine according to PGT radiation technique has been introduced as conversion factor. Results: In PGT method, CTDIvol was 10.6mGy and Organ Dose/CTDIvol conversion factor for esophagus, lung, heart, breast, ribs, muscle, spine and spinal cord were obtained as; 0.96, 1.46, 1.2, 3.28. 6.68. 1.35, 3.41 and 0.93 respectively. Conclusion: The results showed while, underestimation of patient dose was found in dose calculation based on CTDIvol, also dose to breast is higher than the other studies. Therefore, the method in this study can be used to provide the actual patient organ dose in CT imaging based on CTDIvol in order to calculation of real effective dose(ED) based on organ dose. This work has been supported by the research chancellor of tehran university of medical sciences(tums), school of medicine, Tehran, Iran.

60 APPLIED LIFE SCIENCES↗

Rock Physics-Based Data Assimilation of Integrated Continuous Active-Source Seismic and Pressure Monitoring Data during Geological Carbon Storage

Summary There has been substantial controversy concerning the role of geological carbon storage (GCS) in sequestering anthropogenic carbon emissions to mitigate climate change and global warming. Arguments center on the inability to monitor a geological storage site precisely and continuously, especially highlighting the associated costs and spatiotemporal trade-offs when using conventional subsurface monitoring techniques (well logs, core samples, chemical tracers, and 4D seismics). Active surveillance of GCS sites is essential for managing and mitigating potential leaks but is also required by regulation. With the goal of enhancing the monitoring capability at GCS sites, we present a rock physics-based joint data assimilation model to study a popular GCS site at Cranfield, Mississippi, USA. Synthetic continuous active-source seismic monitoring (CASSM) data (in the form of Vp and Qp measurements) and wellbore pressure monitoring data are assimilated with an ensemble of reservoir realizations to monitor gas saturation and reservoir pressure changes over a period of 100 years. Synthetic seismic attributes are generated using rock physics models (RPMs) and wellbore pressure monitoring data are extracted from the ground truth. Two assimilation methods, ensemble Kalman filter (EnKF) and ensemble Kalman smoother (EnKS), are tested in an observation system simulation experiment (OSSE) environment to assess the prediction accuracy of the individual and composite observation systems. The joint monitoring system achieves more accurate estimates of gas saturation and pressure, across the time span from start of injection to end of forecast, as compared to a single type of monitoring tool and irrespective of data assimilation algorithm choice. These results indicate that jointly assimilated data from two types of sensors (in this case, crosswell seismic and downhole pressure) may lead to a more risk-reducing monitoring design. One would expect that more data, vis-à-vis inclusion of a new sensor type, will improve the accuracy of any GCS monitoring system. However, from a practical standpoint, one important question is whether such a gain in accuracy is worth the additional cost associated with the new sensor. This paper focuses on quantifying the gain in accuracy, such that a practitioner can answer this question.

Engineering↗

Solid state NMR method development and studies of biological and biomimetic nanocomposites

This thesis describes application and development of advanced solid-state nuclear magnetic resonance techniques for complex materials, in particular organic-inorganic nanocomposites and thermoelectric tellurides. The apatite-collagen interface, essential for understanding the biomineralization process in bone and engineering the interface for controlled bio-mimetic synthesis and optimized mechanical properties, is buried within the nanocomposite of bone. We used multinuclear solid-state NMR to study the composition and structure of the interface. Citrate has been identified as the main organic molecule strongly bound to the apatite surface with a density of 1/(2 nm) 2 , covering 1/6 of the total surface area in bovine bone. Citrate provides more carboxylate groups, one of the key functional groups found to affect apatite nucleation and growth, than all the non-collagenous proteins all together in bone; thus we propose that citrate stabilizes apatite crystals at a very small thickness of ~3 nm (4 unit cells) to increase bone fracture tolerance. The hypothesis has been confirmed in vitro by adding citrate in the bio-mimetic synthesis of polymerhydroxyapatite nanocomposites. The results have shown that the size of hydroxyapatite nanocrystals decreases as increasing citrate concentration. With citrate concentrations comparable to that in body fluids, similar-sized nanocrystals as in bone have been produced. Besides the dimensions of the apatite crystals, the composition of bone also affects its biofunctional and macroscopic mechanical properties; therefore, our team also extended its effort to enhance the inorganic portion in our bio-mimetic synthesis from originally 15 wt% to current 50 wt% compared to 65 wt% in bovine bone, by using Lysine-Leucine hydroxyapatite nucleating diblock co-polypeptide, which forms a gel at very low concentration. In this thesis, various advanced solid state NMR techniques have been employed to characterize nanocomposites. Meanwhile, we have developed new methods to achieve broadband high resolution NMR and improve the accuracy of inter-nuclear distance measurements involving quadrupolar spins. Broadband high resolution NMR of spin-1/2 nuclei has been accomplished by the adaptation of the magic angle turning (MAT) method to fast magic angle spinning, termed fast MAT, by solving technical problems such as off resonance effects. Fast MAT separates chemical shift anisotropy and isotropic chemical shifts over a spectral range of ~1.8 γB 1 without significant distortions. Fast MAT 125 Te NMR has been applied to study technologically important telluride materials with spectra spreading up to 190 kHz. The signal-to-noise ratio of the spectra is significantly improved by using echo-matched Gaussian filtering in offline data processing. The accuracy of the measured distances between spin-1/2 and quadrupolar nuclei with methods such as SPIDER and REAPDOR has been improved by compensating for the fast longitudinal quadrupolar relaxation on the sub-millisecond with a modified S 0 pulse sequence. Also, the T1Q effect on the spin coherence and its spinning speed dependency has been explored and documented with analytical and numerical simulations as well as experimental measurements.

36 MATERIALS SCIENCE↗

Fatigue-Crack Detection and Monitoring through the Scattered-Wave Two-Dimensional Cross-Correlation Imaging Method Using Piezoelectric Transducers

Piezoelectric transducers are convenient enablers for generating and receiving Lamb waves for damage detection. Fatigue cracks are one of the most common causes for the failure of metallic structures. Increasing emphasis on the integrity of critical structures creates an urgent need to monitor structures and to detect cracks at an early stage to prevent catastrophic failures. This paper presents a two-dimensional (2D) cross-correlation imaging technique that can not only detect a fatigue crack but can also precisely image the fatigue cracks in metallic structures. The imaging method was based on the cross-correlation algorithm that uses incident waves and the crack-scattered waves of all directions to generate the crack image. Fatigue testing for crack generation was then conducted in both an aluminum plate and a stainless-steel plate. Piezoelectric wafer transducer was used to actuate the interrogating Lamb wave. To obtain the scattered waves as well as the incident waves, a scanning laser Doppler vibrometer was adopted for acquiring time-space multidimensional wavefield, followed with frequency-wavenumber processing. The proof-of-concept study was conducted in an aluminum plate with a hairline fatigue crack. A frequency-wavenumber filtering method was used to obtain the incident wave and the scattered wave wavefields for the cross-correlation imaging. After this, the imaging method was applied to evaluate cracks on a stainless-steel plate generated during fatigue loading tests. The presented imaging method showed successful inspection and quantification results of the crack and its growth.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessment of volumetric noise and resolution performance for linear and nonlinear CT reconstruction methods

Purpose: For nonlinear iterative image reconstructions (IR), the computed tomography (CT) noise and resolution properties can depend on the specific imaging conditions, such as lesion contrast and image noise level. Therefore, it is imperative to develop a reliable method to measure the noise and resolution properties under clinically relevant conditions. This study aimed to develop a robust methodology to measure the three-dimensional CT noise and resolution properties under such conditions and to provide guidelines to achieve desirable levels of accuracy and precision. Methods: The methodology was developed based on a previously reported CT image quality phantom. In this methodology, CT noise properties are measured in the uniform region of the phantom in terms of a task-based 3D noise-power spectrum (NPS{sub task}). The in-plane resolution properties are measured in terms of the task transfer function (TTF) by applying a radial edge technique to the rod inserts in the phantom. The z-direction resolution properties are measured from a supplemental phantom, also in terms of the TTF. To account for the possible nonlinearity of IR, the NPS{sub task} is measured with respect to the noise magnitude, and the TTF with respect to noise magnitude and edge contrast. To determine the accuracy and precision of the methodology, images of known noise and resolution properties were simulated. The NPS{sub task} and TTF were measured on the simulated images and compared to the truth, with criteria established to achieve NPS{sub task} and TTF measurements with <10% error. To demonstrate the utility of this methodology, measurements were performed on a commercial CT system using five dose levels, two slice thicknesses, and three reconstruction algorithms (filtered backprojection, FBP; iterative reconstruction in imaging space, IRIS; and sinogram affirmed iterative reconstruction with strengths of 5, SAFIRE5). Results: To achieve NPS{sub task} measurements with <10% error, the number of regions of interest needed to be greater than 65. To achieve TTF measurements with <10% error, the contrast-to-noise ratio of the edge needed to be ≥15, achievable by averaging multiple slices across the same edge. The NPS{sub task} measured on a commercial CT system showed IR's reduced noise (IRIS, 30% and SAFIRE5, 55%) and “waxier” texture (peak frequencies: FBP, 0.25 mm{sup −1}; IRIS, 0.23 mm{sup −1}; and SAFIRE5, 0.16 mm{sup −1}). The TTF measured within the axial plane showed improved in-plane resolution with SAFIRE5 at the TTF 50% frequency, f{sub 50} (FBP, 0.36–0.41 mm{sup −1}; SAFIRE5, 0.37–0.46 mm{sup −1}). The TTF measured along the axial direction showed improved z-direction resolution with thinner slice thickness (f{sub 50}: 0.6 mm, 0.35–0.79 mm{sup −1}; 1.5 mm, 0.22–0.3 mm{sup −1}) and with SAFIRE5 (f{sub 50}: FBP, 0.35–0.52 mm{sup −1}; SAFIRE5, 0.42–0.79 mm{sup −1}). Both in-plane and z-direction resolution of SAFIRE5 showed strong dependency on contrast, reflecting SAFIRE5's nonlinearity. Conclusions: A methodology was developed to measure three-dimensional CT noise and resolution properties for iterative reconstruction, especially at challenging measurement conditions with low contrast and high image noise. The methodology also demonstrated its utility for evaluating commercial CT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Final Technical Report Recovery Act: Online Nonintrusive Condition Monitoring and Fault Detection for Wind Turbines

The penetration of wind power has increased greatly over the last decade in the United States and across the world. The U.S. wind power industry installed 1,118 MW of new capacity in the first quarter of 2011 alone and entered the second quarter with another 5,600 MW under construction. By 2030, wind energy is expected to provide 20% of the U.S. electricity needs. As the number of wind turbines continues to grow, the need for effective condition monitoring and fault detection (CMFD) systems becomes increasingly important [3]. Online CMFD is an effective means of not only improving the reliability, capacity factor, and lifetime, but it also reduces the downtime, energy loss, and operation and maintenance (O&M) of wind turbines. The goal of this project is to develop novel online nonintrusive CMFD technologies for wind turbines. The proposed technologies use only the current measurements that have been used by the control and protection system of a wind turbine generator (WTG); no additional sensors or data acquisition devices are needed. Current signals are reliable and easily accessible from the ground without intruding on the wind turbine generators (WTGs) that are situated on high towers and installed in remote areas. Therefore, current-based CMFD techniques have great economic benefits and the potential to be adopted by the wind energy industry. Specifically, the following objectives and results have been achieved in this project: (1) Analyzed the effects of faults in a WTG on the generator currents of the WTG operating at variable rotating speed conditions from the perspective of amplitude and frequency modulations of the current measurements; (2) Developed effective amplitude and frequency demodulation methods for appropriate signal conditioning of the current measurements to improve the accuracy and reliability of wind turbine CMFD; (3) Developed a 1P-invariant power spectrum density (PSD) method for effective signature extraction of wind turbine faults with characteristic frequencies in the current or current demodulated signals, where 1P stands for the shaft rotating frequency of a WTG; (4) Developed a wavelet filter for effective signature extraction of wind turbine faults without characteristic frequencies in the current or current demodulated signals; (5) Developed an effective adaptive noise cancellation method as an alternative to the wavelet filter method for signature extraction of wind turbine faults without characteristic frequencies in the current or current demodulated signals; (6) Developed a statistical analysis-based impulse detection method for effective fault signature extraction and evaluation of WTGs based on the 1P-invariant PSD of the current or current demodulated signals; (7) Validated the proposed current-based wind turbine CMFD technologies through extensive computer simulations and experiments for small direct-drive WTGs without gearboxes; and (8) Showed, through extensive experiments for small direct-drive WTGs, that the performance of the proposed current-based wind turbine CMFD technologies is comparable to traditional vibration-based methods. The proposed technologies have been successfully applied for detection of major failures in blades, shafts, bearings, and generators of small direct-drive WTGs. The proposed technologies can be easily integrated into existing wind turbine control, protection, and monitoring systems and can be implemented remotely from the wind turbines being monitored. The proposed technologies provide an alternative to vibration-sensor-based CMFD. This will reduce the cost and hardware complexity of wind turbine CMFD systems. The proposed technologies can also be combined with vibration-sensor-based methods to improve the accuracy and reliability of wind turbine CMFD systems. When there are problems with sensors, the proposed technologies will ensure proper CMFD for the wind turbines, including their sensing systems. In conclusion, the proposed technologies offer an effective means to achieve condition-based smart maintenance for wind turbines and have a great potential to be adopted by the wind energy industry due to their almost no-cost, nonintrusive features. Although only validated for small direct-drive wind turbines without gearboxes, the proposed technologies are also applicable for CMFD of large-size wind turbines with and without gearboxes. However, additional investigations are recommended in order to apply the proposed technologies to those large-size wind turbines.

17 WIND ENERGY↗

Surface and material analytics based on Dresden-EBIS platform technology

Nowadays widely used mass spectrometry systems utilize energetic ions hitting a sample and sputter material from the surface of a specimen. The generated secondary ions are separated and detected with high mass resolution to determine the target materials constitution. Based on this principle, we present an alternative approach implementing a compact Electron Beam Ion Source (EBIS) in combination with a Liquid Metal Ion Source (LMIS). An LMIS can deliver heavy elements which generate high sputter yields on a target surface. More than 90% of this sputtered material consists of mono- and polyatomic neutrals. These particles are able to penetrate the magnetic field of an EBIS and they will be ionized within the electron beam. A broad spectrum of singly up to highly charged ions can be extracted depending on the operation conditions. Polyatomic ions will decay during the charge-up process. A standard bending magnet or a Wien filter is used to separate the different ion species due to their mass-to-charge ratio. Using different charge states of ions as it is common with EBIS it is also possible to resolve interfering charge-to-mass ratios of only singly charged ions. Different setups for the realization of feeding the electron beam with sputtered atoms of solids will be presented and discussed. As an example the analysis of a copper surface is used to show high-resolution spectra with low background noise. Individual copper isotopes and clusters with different isotope compositions can be resolved at equal atomic numbers. These results are a first step for the development of a new compact low-cost and high-resolution mass spectrometry system. In a more general context, the described technique demonstrates an efficient method for feeding an EBIS with atoms of nearly all solid elements from various solid target materials. The new straightforward design of the presented setup should be of high interest for a broad range of applications in materials research as well as for applications connected to analyzing the biosphere, hydrosphere, lithosphere, cosmosphere and technosphere.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

WE-AB-204-01: Performance Characterization of Regularized-Reconstruction Algorithm for 90Y PET/CT Images

Purpose: {sup 90}Y PET/CT imaging and quantification have recently been suggested as an approach of treatment verification. However, due to low positron yield (32ppm), the {sup 90}Y-PET/CT images are very noisy. Iterative reconstruction techniques that employ regularization, e.g. block sequential regularized expectation maximization (BSREM) algorithm (recently implemented on GE scanners – QClear™), has the potential to increase quantitative accuracy with lower noise penalty compared to OSEM. Our aim is to investigate the performance of RR algorithms in {sup 90}Y PET/CT studies. Methods: A NEMA IEC phantom filled with 3GBq {sup 90}YCl{sub 2} (to simulate patient treatment) was imaged on GE-D690 for 1800s/bed. The sphere-to-background ratio of 7. The data were reconstructed using OSEM and BSREM with PSF modeling and TOF correction while varying the iterations (IT) from 1–6 with fixed 24subsets. For BSREM, the edge-preservation parameter (γ ) was 2 and the penalty-parameters (β) was varied 350–950. In all cases a post-reconstruction filter of 5.2mm (2pixel) transaxial and standard z-axis were used. Sphere average activity concentration (AC) and background standard deviation (SD) were then calculated from VOIs drawn in the spheres and background. Results: Increasing IT from 1to6, the %SD in OSEM increased from 30% to 80%, whereas %SD in BSREM images increased by <5% for all βs. BSREM with β=350 didn’t offer any improvement over OSEM (convergence of mean achieved at 2 IT, in this study). Increasing β from 350 to 950 reduced the AC accuracy of small spheres (<20mm) by 10% and noise from 40% to 20%, which resulted in CNR increase from 11 to 17. Conclusion: In count-limited studies such as {sup 90}Y PET/CT, BSREM can be used to suppress image noise and increase CNR at the expense of a relatively small decrease of quantitative accuracy. The BSREM parameters need to be optimized for each study depending on the radionuclides and count densities. Research reported in this publication was supported by the National Cancer Institute of the National Institutes of Health under Award Number R01CA13898 and was also partly supported by General Electric.

60 APPLIED LIFE SCIENCES↗