Unfulfilled needs in IR astronomy focal-plane readout electronics

The NOAO's 8-m IR optimized telescope for Mauna Kea and NASA's SIRTF show that from 1 to 200 microns there are a number of unfulfilled needs in readout electronics. These include: extremely low readnoise, less than 10 electrons, stable operation at temperatures as low as 2 K, high well capacity, greater than 1 e 7 electrons, and integration times from 30 msec to over 100 sec. Sensors for adaptive optics systems are required with readnoise less than 10 electrons and response times of 30 msec. They should be highly efficient from 1 to 2.5 microns, but may have small formats. Ground-based imagers at these wavelengths need comparable readnoise but longer integration times, and the largest possible formats are essential. To achieve these goals improved cryogenic MOSFETS are essential and complete cryogenic CMOS circuits are highly desirable. Experimental cryoptimized MFETS promise to exceed the above noise requirements at 77 K and approach the needs at 2 K.

Low, Frank J.↗

An atlas of monthly mean distributions of SSMI surface wind speed, ARGOS buoy drift, AVHRR/2 sea surface temperature, and ECMWF surface wind components during 1990

The following monthly mean global distributions for 1990 are proposed with a common color scale and geographical map: 10-m height wind speed estimated from the Special Sensor Microwave Imager (SSMI) on a United States (US) Air Force Defense Meteorological Satellite Program (DMSP) spacecraft; sea surface temperature estimated from the advanced very high resolution radiometer (AVHRR/2) on a U.S. National Oceanic and Atmospheric Administration (NOAA) spacecraft; Cartesian components of free drifting buoys which are tracked by the ARGOS navigation system on NOAA satellites; and Cartesian components on the 10-m height wind vector computed by the European Center for Medium-Range Weather Forecasting (ECMWF). Charts of monthly mean value, sampling distribution, and standard deviation values are displayed. Annual mean distributions are displayed.

Halpern, D.↗

An atlas of monthly mean distributions of SSMI surface wind speed, AVHRR/2 sea surface temperature, AMI surface wind velocity, TOPEX/POSEIDON sea surface height, and ECMWF surface wind velocity during 1993

The following monthly mean global distributions for 1993 are presented with a common color scale and geographical map: 10-m height wind speed estimated from the Special Sensor Microwave Imager (SSMI) on a United States (U.S.) Air Force Defense Meteorological Satellite Program (DMSP) spacecraft; sea surface temperature estimated from the Advanced Very High Resolution Radiometer (AVHRR/2) on a U.S. National Oceanic and Atmospheric Administration (NOAA) satellite; 10-m height wind speed and direction estimated from the Active Microwave Instrument (AMI) on the European Space Agency (ESA) European Remote Sensing (ERS-1) satellite; sea surface height estimated from the joint U.S.-France Topography Experiment (TOPEX)/POSEIDON spacecraft; and 10-m height wind speed and direction produced by the European Center for Medium-Range Weather Forecasting (ECMWF). Charts of annual mean, monthly mean, and sampling distributions are displayed.

Halpern, D.↗

GeoNEX-ML: A Machine Learning System for Geostationary Satellite Imagery

Improved capabilities of earth monitoring satellites are enabling a wide range of studies on the environmental effects of climate change, often leveraging the recent advancements in machine learning. At the same time, the new capabilities, including higher spatial resolution and temporal frequency, are expanding the amount of data generated at exponential rates. Further, a large majority of archived datasets generated by scientific processing is never used. This motivates the development of an efficient machine learning system for end-to-end processing of multi-level satellite datasets, from level 1 top of atmosphere observations to user friendly environmental variables of interest. Using current generation geostationary satellites GOES-16/17 (NOAA/NASA), Himawari-8/9 (JAXA), and GK-2A (Korea), we present an interchangeable set of machine models to perform spectral adjustment, physical model emulation, LEO-GEO emulation, and optical flow in a high performance computing environment. We use these tools to generate consistent virtual observations across sensors, perform atmospheric correction and cloud detection, and estimate land surface temperature and atmospheric winds. This approach aims to improve the robustness of remotely sensed data processing by learning from diverse sets of observations while enabling near real-time and on-demand capabilities.

Geostationary satellites↗

Long-Term field testing of the accuracy and HVAC energy savings potential of occupancy presence sensors in A Single-Family home

The energy-saving potential of occupancy-centric smart thermostats has been extensively explored in simulations but lacked field testing for energy savings quantification and sensor performance assessment in real buildings. This paper presents a long-term field study conducted in a single-family home in Texas, U.S. to evaluate the performance of occupancy-centric controls (OCC) of HVAC (heating, ventilation, and air-conditioning) system in terms of energy savings, sensor accuracy, and impact on electric peak demand. The test site was equipped with a commercial off-the-shelf (COTS) smart thermostat and multiple occupancy presence sensors for OCC implementation. Additionally, a sub-metering system was installed to monitor electricity consumption of various end-use equipment, including the HVAC system. A supplementary device was installed to track the ground-truth occupancy for the accuracy evaluation of the occupancy presence sensor. Scenarios of baseline and OCC controls were alternated weekly over the 20-month testing period. The results indicated an effective OCC execution, as evidenced by indoor temperature profiles. During the 2023 cooling season, OCC achieved total energy savings of 1,958 kWh, corresponding to a 17.6% energy savings ratio. Under certain conditions, daily HVAC energy savings reached as high as 17 kWh, with a savings ratio of 35%. Sensor performance showed an overall accuracy of 83.8%, a False Positive Rate (FPR) of 12.8%, and a False Negative Rate (FNR) of 47.4%. A key limitation was the sensor’s inability to detect stationary occupants during sleep, leading to a midnight FNR of nearly 100% and significantly compromising thermal comfort. Additionally, the implementation of OCC resulted in extended periods of high electricity demand on summer afternoons, affecting occupant’s thermal comfort and posing potential challenges to community-level grid operations if OCC were widely adopted. Furthermore, this study addresses a critical research gap by empirically investigating energy-saving potential and occupancy sensor performance in residential buildings. Through a comprehensive field-testing study, the research examines the interrelationship between sensor accuracy, energy savings, and thermal comfort, an area that has received limited attention in the current literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A self-calibrating optomechanical force sensor with femtonewton resolution

We report the development of an ultrasensitive optomechanical sensor designed to improve the accuracy and precision of force measurements with atomic force microscopy. The sensors reach quality factors of 4.3 × 10{sup 6} and force resolution on the femtonewton scale at room temperature. Self-calibration of the sensor is accomplished using radiation pressure to create a reference force. Self-calibration enables in situ calibration of the sensor in extreme environments, such as cryogenic ultra-high vacuum. The senor technology presents a viable route to force measurements at the atomic scale with uncertainties below the percent level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Use of Electrical Imaging and Distributed Temperature Sensing Methods to Characterize Surface Water-Groundwater Exchange Regulating Uranium Transport at the Hanford 300 Area, Washington

A critical challenge in advancing prediction of solute transport between contaminated aquifers and rivers is improving understanding of how fluctuations in river stage, combined with subsurface heterogeneity, impart spatiotemporal complexity to solute exchange along river corridors. Here, we explored the use of waterborne geoelectrical imaging, in conjunction with fiber-optic distributed temperature sensor (DTS) monitoring, to improve the conceptual model for uranium transport within the hyporheic corridor at the Hanford 300 Area. We first inverted waterborne geoelectrical (resistivity and induced polarization) datasets for distributions of electrical resistivity and polarizability, from which the spatial complexity of the primary hydrogeologic units was reconstructed. Variations in the depth to the interface between the overlying coarse-grained, high permeability Hanford formation and the underlying finer-grained, less permeable Ringold formation, an important contact that limits vertical migration of contaminants, were resolved along ~3 km of the river corridor centered on the 300 Area. Polarizability images were translated into lithologic images using established relationships between polarizability and surface area normalized to pore volume (Spor). The spatial variability captured in the geoelectrical datasets indicates that previous studies based on borehole projections and point probing overestimate the contributing area for uranium exchange within the Columbia River at the Hanford 300 Area. The DTS data recorded on 1. 5 km of cable with a 1 m spatial resolution and 5 minute sampling interval revealed sub-reaches showing (1) high temperature anomalies and, (2) a strong negative correlation between temperature and river stage, both indicative of groundwater influxes during winter months. The DTS datasets confirm the hydrologic significance of the variability identified in the geoelectrical imaging and reveal a pattern of highly focused hyporheic exchange, with exchange concentrated at springs where the Hanford formation is thick, and coinciding with a paleochannel identified in ground penetrating radar surveys at one location. No evidence for focused hyporheic exchange is observed in the DTS data where the Ringold unit is in contact with the riverbed. Our findings illustrate how the combination of waterborne geoelectrical imaging and DTS technologies can characterize hyporheic exchange in a complex, coupled river-aquifer system.

300 area↗

Ground Test Stand Development for One-step Electrochemical Production of High-Pressure Oxygen

NASA designed a test rig, High-Pressure Oxygen Generation Assembly (HPOGA) to test a novel method of electrolysis as an alternative technology to the state-of-the-art Oxygen Generation Assembly (OGA) currently on the International Space Station (ISS). This approach involves utilizing a specialized electrolysis cell stack designed to both generate and compress high-pressure oxygen up to 3600 PSIG. The design eliminates the need for an external compressor and hydrogen separator, streamlining the oxygen generation process. HPOGA tests the viability of an electrolysis cell stack for extended life usage. Within the system, there are several key subsystems: nitrogen, high/low pressure oxygen, hydrogen, water recirculation, and water injection. The water injection subsystem supplies deionized (DI) water to a centralized reservoir for consumption. Subsequently, a water recirculation loop transfers the DI water across the cathode side of the electrolysis cell stack with constant flow rate. The result is a supply of hydrogen in the water loop and oxygen accumulation on the anode side of the cell stack. Hydrogen is evaporated out as part of the hydrogen sub-system which also measures hydrogen/oxygen concentration for safety. The oxygen subsystem is responsible for managing high pressure oxygen, O2 exhaust, and conducting hydrogen/oxygen concentration measurements. The nitrogen subsystem serves dual functions, purging the hydrogen/oxygen subsystems, and regulating pressure in both high/low-pressure O2 sections via pneumatic back pressure regulators. Various sensors monitor pressure, temperature, humidity, gas concentration and flow rate in each subsystem. This paper presents the design and testing of a comprehensive test stand, which serves to operate and functionally verify the performance of the electrolysis cell while offering valuable lessons learned.

electrolysis↗

Highly Efficient Multilayer Thermoelectric Devices

Multilayer thermoelectric devices now at the prototype stage of development exhibit a combination of desirable characteristics, including high figures of merit and high performance/cost ratios. These devices are capable of producing temperature differences of the order of 50 K in operation at or near room temperature. A solvent-free batch process for mass production of these state-of-the-art thermoelectric devices has also been developed. Like prior thermoelectric devices, the present ones have commercial potential mainly by virtue of their utility as means of controlled cooling (and/or, in some cases, heating) of sensors, integrated circuits, and temperature-critical components of scientific instruments. The advantages of thermoelectric devices for such uses include no need for circulating working fluids through or within the devices, generation of little if any noise, and high reliability. The disadvantages of prior thermoelectric devices include high power consumption and relatively low coefficients of performance. The present development program was undertaken in the hope of reducing the magnitudes of the aforementioned disadvantages and, especially, obtaining higher figures of merit for operation at and near room temperature. Accomplishments of the program thus far include development of an algorithm to estimate the heat extracted by, and the maximum temperature drop produced by, a thermoelectric device; solution of the problem of exchange of heat between a thermoelectric cooler and a water-cooled copper block; retrofitting of a vacuum chamber for depositing materials by sputtering; design of masks; and fabrication of multilayer thermoelectric devices of two different designs, denoted I and II. For both the I and II designs, the thicknesses of layers are of the order of nanometers. In devices of design I, nonconsecutive semiconductor layers are electrically connected in series. Devices of design II contain superlattices comprising alternating electron-acceptor (p)-doped and electron-donor (n)-doped, nanometer- thick semiconductor layers.

Boufelfel, Ali↗

Heat flux sensor calibration using noninteger system identification: Theory, experiment, and error analysis

This paper concerns the improvement of the calibration technique of null point calorimeters generally used in high enthalpy plasma flows. Based on the linearity assumption, this technique leads to calculate the impulse response that relates the heat flux at the tip of the sensor according to the temperature at the embedded thermocouple close to the heated surface. The noninteger system identification (NISI) procedure is applied. The NISI technique had been well described in previous study. The present work focuses on the accuracy of the identified system in terms of absorbed heat flux during the calibration experiment and of the estimated parameters in the model. The impulse response is thus calculated along with its associated standard deviation. Furthermore, this response is compared with that of the one-dimensional semi-infinite medium, which is classically used in practical applications. The asymptotic behavior of the identified system at the short times is analyzed for a better understanding of the noninteger identified system. Finally, the technique was applied to a new sensor geometry that has been developed particularly for high enthalpy plasma flows and it is shown that the method can be applied to any geometry suitable for a certain test configuration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of MEMS based pyroelectric thermal energy harvesters

The efficient conversion of waste thermal energy into electrical energy is of considerable interest due to the huge sources of low-grade thermal energy available in technologically advanced societies. Our group at the Oak Ridge National Laboratory (ORNL) is developing a new type of high efficiency thermal waste heat energy converter that can be used to actively cool electronic devices, concentrated photovoltaic solar cells, computers and large waste heat producing systems, while generating electricity that can be used to power remote monitoring sensor systems, or recycled to provide electrical power. The energy harvester is a temperature cycled pyroelectric thermal-to-electrical energy harvester that can be used to generate electrical energy from thermal waste streams with temperature gradients of only a few degrees. The approach uses a resonantly driven pyroelectric capacitive bimorph cantilever structure that potentially has energy conversion efficiencies several times those of any previously demonstrated pyroelectric or thermoelectric thermal energy harvesters. The goals of this effort are to demonstrate the feasibility of fabricating high conversion efficiency MEMS based pyroelectric energy converters that can be fabricated into scalable arrays using well known microscale fabrication techniques and materials. These fabrication efforts are supported by detailed modeling studies of the pyroelectric energy converter structures to demonstrate the energy conversion efficiencies and electrical energy generation capabilities of these energy converters. This paper reports on the modeling, fabrication and testing of test structures and single element devices that demonstrate the potential of this technology for the development of high efficiency thermal-to-electrical energy harvesters.

14 SOLAR ENERGY↗

Logic Gates Made of N-Channel JFETs and Epitaxial Resistors

Prototype logic gates made of n-channel junction field-effect transistors (JFETs) and epitaxial resistors have been demonstrated, with a view toward eventual implementation of digital logic devices and systems in silicon carbide (SiC) integrated circuits (ICs). This development is intended to exploit the inherent ability of SiC electronic devices to function at temperatures from 300 to somewhat above 500 C and withstand large doses of ionizing radiation. SiC-based digital logic devices and systems could enable operation of sensors and robots in nuclear reactors, in jet engines, near hydrothermal vents, and in other environments that are so hot or radioactive as to cause conventional silicon electronic devices to fail. At present, current needs for digital processing at high temperatures exceed SiC integrated circuit production capabilities, which do not allow for highly integrated circuits. Only single to small number component production of depletion mode n-channel JFETs and epitaxial resistors on a single substrate is possible. As a consequence, the fine matching of components is impossible, resulting in rather large direct-current parameter distributions within a group of transistors typically spanning multiples of 5 to 10. Add to this the lack of p-channel devices to complement the n-channel FETs, the lack of precise dropping diodes, and the lack of enhancement mode devices at these elevated temperatures and the use of conventional direct coupled and buffered direct coupled logic gate design techniques is impossible. The presented logic gate design is tolerant of device parameter distributions and is not hampered by the lack of complementary devices or dropping diodes. In addition to n-channel JFETs, these gates include level-shifting and load resistors (see figure). Instead of relying on precise matching of parameters among individual JFETS, these designs rely on choosing the values of these resistors and of supply potentials so as to make the circuits perform the desired functions throughout the ranges over which the parameters of the JFETs are distributed. The supply rails V(sub dd) and V(sub ss) and the resistors R are chosen as functions of the distribution of direct-current operating parameters of the group of transistors used.

Krasowski, Michael J.↗

Signal amplification in a solid-state sensor through asymmetric many-body echo

Electronic spins of nitrogen–vacancy centres in diamond constitute a promising system for micro- and nanoscale magnetic sensing, because of their operation under ambient conditions, ease of placement in close proximity to sensing targets and biological compatibility. At high densities, the electronic spins interact through dipolar coupling, which typically limits but can also potentially enhance sensing performance. Here we report the experimental demonstration of many-body signal amplification in a solid-state, room-temperature quantum sensor. Our approach uses time-reversed two-axis-twisting interactions, engineered through dynamical control of the quantization axis and Floquet engineering in a two-dimensional ensemble of nitrogen–vacancy centres. We observe that optimal amplification occurs when the backward evolution time equals twice the forward evolution time, in sharp contrast to the conventional Loschmidt echo. These observations can be understood as resulting from an underlying time-reversed mirror symmetry of the microscopic dynamics, providing key insights into signal amplification and opportunities for practical entanglement-enhanced quantum sensing.

quantum information↗

Design and testing of a sensitive heat-flow calorimeter for measuring radioactive waste in 55-gallon (US) drums - 15334

A sensitive large volume calorimeter for measuring the thermal power generated by the radioactive decay of heat producing materials in 55-gallon drums has been developed and tested. The technology is applicable to the measurement of all radionuclides that decay by alpha or beta decay such as waste or product material containing plutonium, tritium and americium. It is also relevant to the measurement of drums where gamma rays from radioactive decay are captured locally in attenuating materials and the resulting rate of thermal energy deposition (sample thermal power) is of sufficient magnitude for a calorimetry measurement. The initial application of the drum calorimeter is for measuring and characterizing plutonium-bearing waste drums. The calorimeter design has optimised the two characteristics of high thermal sensitivity and reduced measurement times. In order to achieve these characteristics for large volume drums, the heat-flow method of operation was chosen in a single measurement chamber configuration. Using a drum-lifting device, the waste drum is positioned on a sliding platform and subsequently moved by the operator inside an octagonal inner chamber, which acts as the heat sink. The heat-sink chamber has significant thermal inertia and remains effectively at a constant temperature throughout the duration of a drum measurement. The octagonal inner measurement chamber is constructed inside a multi-layer external thermal enclosure, which provides both thermal insulation and significant thermal inertia. The external thermal enclosure isolates the measurement process from the effects of changes in the external ambient temperature. During a measurement, heat flows from the drum being measured to the heat sink. This heat-flow is measured by a series of thermopile sensor assemblies, which are positioned between the waste drum and the heat sink. A high sensitivity of greater than 200 μV/mW (microvolts per milliwatt) has been achieved using multiple close-coupled thermopile sensors in each assembly. Reduced measurement times are achieved by positioning the thermopile sensor assemblies close to the drum surface in order to reduce the thermal transport delay. The instrument incorporates a calibrated precision power supply, which requires annual recalibration and is traceable to national standards. It is used to power a calibration heater that has been built into a calibration and test drum. The calibration and test drum is used both to calibrate the instrument and provide periodic confirmation of correct operation. Measurements of calorimeter performance are reported for a range of drum thermal powers. Long-term temperature drift measurements are used to provide estimates of the minimum detectable drum thermal power and hence the minimum detectable activity for both plutonium and tritium. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Status of high-range and flow-direction sensor

This paper describes the two systems used to provide certain research measurements for the X-15 aircraft. These systems are: (1) a probe and associated system that will be capable of operating throughout the extreme temperature environment encountered on reentry to provide a measure of the angle of attack and sideslip to the pilot and (2) an instrumented ground range capable of monitoring the flight of the airplane throughout its entire trajectory.

Truszynski, G M↗

Design Report on the MiniFuel Instrumented Test Apparatus for Understanding Radiation Effects

Most nuclear fuels irradiations at Oak Ridge National Laboratory (ORNL) over the past decade have been conducted using MiniFuel—a static capsule design employing subscale fuel specimens to collect separate-effects irradiated fuel performance data. Irradiation conditions for MiniFuel experiments are predicted pre-test using reactor physics, and thermal models are verified post-irradiation via SiC dilatometry and various spectrometry methods. Relevant fuel performance parameters are also observed post-irradiation in a hot cell, thereby providing a single data point for each parameter representing the cumulative effects of the irradiation conditions. Substantially more data can be harvested from a single test and within a shorter duration by instrumenting irradiation vehicles and measuring desired quantities in situ. This report presents the design and analysis of the MiniFuel INstrumented Irradiation Test Apparatus for Understanding Radiation Effects (MINITAURE)—an instrumented test rig based on the separate-effects MiniFuel concept that aims to capture fission gas release (FGR) and thermal conductivity degradation of fuel specimens during irradiation in the High Flux Isotope Reactor (HFIR). MINITAURE will be integrated with the Materials Irradiation Facility (MIF) located in the HFIR building outside the reactor containment. The MIF will act as the instrumentation and control center for the experiment, enabling real-time feedback from in situ sensors and control of irradiation temperatures via a gas delivery system. Two unique capsule designs were developed to capture each phenomenon: the thermal conductivity capsule, which uses a thermopile method to estimate fuel specimen thermal conductivity, and the fission gas release capsule, which will have continuous flowing gas communication to high-purity germanium detectors that are housed in the MIF for monitoring FGR. This report details the reactor physics and heat transfer modeling activities that were used to inform the experiment design and predict capsule performance. It also describes out-of-pile activities conducted to stand up this new capability and verify the measurement techniques. Modeling efforts to date have demonstrated the feasibility of the in situ measurement techniques and supported the development of the MINITAURE assembly configuration. Out-of-pile testing of the thermal conductivity measurement shows promise in capturing relative changes in thermal conductivity. However, significant errors exist in the measured absolute value, posing a need for further refinement.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Characterization of Polymer-Coated MEMS Humidity Sensors for Flight Applications

Under NASA's Aviation Safety Program (AvSP), in addition to wind velocity and temperature, water vapor is considered one key factor in determining aviation weather, which is a substantial contributor to many general aviation (GA) accidents. The conventional and reliable humidity measuring methods such as radiation reflection or absorption have relatively high cost in addition to highly specialized operating and maintenance characteristics. This paper presents characterizations of inexpensive MEMS and capacitance type humidity sensors for their potential use on aircraft. If installed, these sensors are subjected to ambient environmental conditions as well as to different chemicals and deicing fluids used on aircraft. This paper reports the effect of different deicing fluids and chemicals on these inexpensive humidity sensors.

Shams, Qamar A.↗