Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGE ALIGNMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

IAIMFAST: Alignment Implementation for Manufacturing

AIMFAST is a software code used to align facets on a dish concentrator to a specific aimpoint strategy to minimize peak fluxes and maximize system optical performance. AIM FAST uses a large monitor to display fringe patterns, and a machine vision camera to image the reflection of these patterns in the subject dish mirrors. From these images, a detailed map of surface normals can be generated and compared to design or fitted mirror shapes. This fitted comparison is then used to develop a single vector representing the orientation of the facets relative to the design orientation, and provide near-real-time adjustment information to a communicating computer. The communicating computer can display adjustments or directly interface with adjustment tools.

Andraka, Charles E.↗

Multimodal Broadband Vibrational Sum Frequency Generation (MM-BB-V-SFG) Spectrometer and Microscope

A broadband sum frequency generation (BB-SFG) spectrometer with multimodal (MM) capabilities was constructed, which could be routinely reconfigured for tabletop experiments in reflection, transmission, and total internal reflection (TIR) geometries, as well as microscopic imaging. The system was constructed using a Ti:sapphire amplifier (800 nm, pulse width = 85 fs, repetition rate = 2 kHz), an optical parameter amplification (OPA) system for production of broadband IR pulses tunable between 1000 and 4000 cm –1 , and two Fabry–Pérot etalons arranged in series for production of narrowband 800 nm pulses. The key feature allowing the MM operation was the nearly collinear alignment of the visible (fixed, 800 nm) and infrared (tunable, 1000–4000 cm –1 ) pulses which were spatially separated. Physical insights discussed in this paper include the comparison of spectral bandwidth produced with 40 and 85 fs pump beams, the improvement of spectral resolution using etalons, the SFG probe volume in bulk analysis, the normalization of SFG signals, the stitching of multiple spectral segments, and the operation in different modes for air/liquid and adsorbate/solid interfaces, bulk samples, as well as spectral imaging combined with principle component analysis (PCA). Finally, the SFG spectral features obtained with the MM-BB-SFG system were compared with those obtained with picosecond-scanning-SFG system and high-resolution BB-SFG system (HR-BB-SFG) for dimethyl sulfoxide, α-pinene, and various samples containing cellulose (purified commercial products, Cladophora cell wall, cotton and flax fibers, and onion epidermis cell wall).

47 OTHER INSTRUMENTATION↗

A needle guidance system for biopsy and therapy using two-dimensional ultrasound

Image-guided needle biopsies are currently used to provide a definitive diagnosis of breast cancer; however, difficulties in tumor targeting exist as the ultrasound (United States) scan plane and biopsy needle must remain coplanar throughout the procedure to display the actual needle tip position. The additional time associated with aligning and maintaining this coplanar relationship results in increased patient discomfort. Biopsy procedural efficiency is further hindered since needle pathway interpretation is often difficult, especially for needle insertions at large depths that usually require multiple reinsertions. The authors developed a system that would increase the speed and accuracy of current breast biopsy procedures using readily available two-dimensional (2D) US technology. This system is composed of a passive articulated mechanical arm that attaches to a 2D US transducer. The arm is connected to a computer through custom electronics and software, which were developed as an interface for tracking the positioning of the mechanical components in real time. The arm couples to the biopsy needle and provides visual guidance for the physician performing the procedure in the form of a real-time projected needle pathway overlay on an US image of the breast. An agar test phantom, with stainless steel targets interspersed randomly throughout, was used to validate needle trajectory positioning accuracy. The biopsy needle was guided by both the software and hardware components to the targets. The phantom, with the needle inserted and device decoupled, was placed in an x-ray stereotactic mammography (SM) machine. The needle trajectory and bead target locations were determined in three dimensions from the SM images. Results indicated a mean needle trajectory accuracy error of 0.75{+-}0.42 mm. This is adequate to sample lesions that are <2 mm in diameter. Chicken tissue test phantoms were used to compare core needle biopsy procedure times between experienced radiologists and inexperienced resident radiologists using free-hand US and the needle guidance system. Cylindrical polyvinyl alcohol cryogel lesions, colored blue, were embedded in chicken tissue. Radiologists identified the lesions, visible as hypoechoic masses in the US images, and performed biopsy using a 14-gauge needle. Procedure times were compared based on experience and the technique performed. Using a pair-wise t test, lower biopsy procedure times were observed when using the guidance system versus the free-hand technique (t=12.59, p<0.001). The authors believe that with this improved biopsy guidance they will be able to reduce the ''false negative'' rate of biopsies, especially in the hands of less experienced physicians.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of laboratory calibrations of the Airborne Visible/Infrared Imaging Spectrometer (AVIRIS) at the beginning and end of the first flight season

Spectral and radiometric calibrations of AVIRIS are described together with changes in instrument characteristics that occurred during the flight season. These changes include detachment of the optical fibers to two of the four AVIRIS spectrometers, degradation in the optical alignment of the spectrometers due to thermally induced and mechanical warpage, and breakage of a thermal blocking filter in one of the spectrometers. Means of improving the instrument are discussed.

Vane, Gregg↗

Fast imaging of edge localized mode structure and dynamics in DIII-D

Fast-framing images of CIII and D{sub {alpha}} emission in the low-field-side plasma boundary of the DIII-D tokamak [J. L. Luxon, Nucl. Fusion 42, 614 (2002)] show that edge localized modes (ELMs) rapidly eject multiple field-aligned filaments from the plasma edge. The toroidal and poloidal mode numbers of these filaments depend on normalized plasma density, with measured ELM toroidal mode numbers ranging from {<=}10 to 20 in low-density plasmas and 15 to 35 in high-density plasmas. In high-density plasmas with moderate collisionality {nu}{sub ped}*=0.50, ELMs originate at the low-field-side midplane region and the ion parallel velocity in the scrape-off layer is faster for ELMs with larger D{sub {alpha}} divertor emission, suggesting that large ELMs eject higher-temperature ions from deeper within the plasma compared to small ELMs. In low-density plasmas with collisionality {nu}{sub ped}*=0.25, the midplane and divertor ELM signals appear simultaneously, indicating that ELM behavior depends on collisionality. At all {nu}{sub ped}*, ELMs drive parallel fluxes to the divertor; in addition, ELMs drive cross-field propagation of filaments, which results in plasma-wall interactions that are poloidally localized within 15 cm of the midplane. Using the wall interactions as signatures of the filaments in the scrape-off layer, the measured poloidal width of the filament ranges from 1 to 5 cm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Fe Oxidation and Species Distribution at the Rock–Fluid Interface of Marcellus Shale Reacted with Hydraulic Fracturing Fluid

Hydraulic fracturing of shale reservoirs resulted in significant opportunity for increased oil and gas production in the United States. Rock-fluid interactions can cause mineral dissolution and precipitation reactions that lead to permeability changes in the shale matrix, which ultimately may affect transport pathways and hydrocarbon production. Understanding the distribution of secondary precipitates, such as barite and Fe(III) (hydro)oxides, and cation leaching at the rock-fluid interface is an important step to further investigate how these geochemical processes can change permeability and transport pathways. In this study, thin sections of the fracture-matrix interface were made from reacted Marcellus shale cores. The thin sections were characterized using synchrotron X-ray fluorescence imaging and synchrotron X-ray absorption spectroscopy. Fe species with different oxidation states were identified in the maps, together with barite and Ca distribution. The results show that ferrihydrite, as newly formed Fe(III)-bearing precipitates, aligned well with the border of the Ca (e.g., calcite) leaching region in the reaction front. Some Fe-containing clay also dissolved, but the dissolution region for the clay was not as deep as the calcite. Further, the reaction front is about three times deeper in the direction parallel to the shale bedding than that perpendicular to the bedding. The Ca leaching region can be an index for reaction front detection for Marcellus shale. Reactive transport modeling was conducted and the predicted Ca leaching boarder align well with ferrihydrite precipitation, consistent with the experimental observation. The carbonate mineral dissolution can be crucial to promote fluid access into the shale matrix. Together with our previous study on the shale reactive surface, this follow-up study showed similar Ca leaching region and Fe(III) precipitates distribution in the reaction front regardless of barite precipitation on the surface, indicating that the barite coatings on the surface may not pose a significant impact on reactive transport at the shale-fluid interface.

04 OIL SHALES AND TAR SANDS↗

High-speed mapping of surface charge dynamics using sparse scanning Kelvin probe force microscopy

Unraveling local dynamic charge processes is vital for progress in diverse fields, from microelectronics to energy storage. This relies on the ability to map charge carrier motion across multiple length- and timescales and understanding how these processes interact with the inherent material heterogeneities. Towards addressing this challenge, we introduce high-speed sparse scanning Kelvin probe force microscopy, which combines sparse scanning and image reconstruction. This approach is shown to enable sub-second imaging (>3 frames per second) of nanoscale charge dynamics, representing several orders of magnitude improvement over traditional Kelvin probe force microscopy imaging rates. Bridging this improved spatiotemporal resolution with macroscale device measurements, we successfully visualize electrochemically mediated diffusion of mobile surface ions on a LaAlO 3 /SrTiO 3 planar device. Such processes are known to impact band-alignment and charge-transfer dynamics at these heterointerfaces. Furthermore, we monitor the diffusion of oxygen vacancies at the single grain level in polycrystalline TiO 2 . Through temperature-dependent measurements, we identify a charge diffusion activation energy of 0.18 eV, in good agreement with previously reported values and confirmed by DFT calculations. Together, these findings highlight the effectiveness and versatility of our method in understanding ionic charge carrier motion in microelectronics or nanoscale material systems.

25 ENERGY STORAGE↗

Control of asymmetric strain relaxation in InGaAs grown by molecular-beam epitaxy

InGaAs strain relaxation is studied by an in situ multibeam optical stress sensor (MOSS). Strain relaxation during growth of InGaAs on GaAs occurs at different thicknesses and rates along the directions perpendicular to its misfit dislocations, [110] and [110]. We show the asymmetry of relaxation between these directions in real time by aligning the MOSS laser array along [110] and [110]. This asymmetric relaxation data from the MOSS correlates with both x-ray diffraction relaxation analysis and an estimation of the misfit dislocation density from transmission electron microscopy images. Lowering the V/III ratio or raising the growth temperature lowers the thickness of the onset of dislocation formation, changes the relaxation rate, lowers the final relaxation during 2 {mu}m of growth, and shifts the initial direction of relaxation from [110] to [110]. We identify two phases of relaxation that occur at different growth thicknesses. Lowering the V/III ratio changes the relative contribution of each of these phases to the total relaxation of the epilayer.

36 MATERIALS SCIENCE↗

Textured Pr{sub 2}Fe{sub 14}B flakes with submicron or nanosize thickness prepared by surfactant-assisted ball milling

The textured Pr{sub 2}Fe{sub 14}B nanoflakes were produced by surfactant-assisted ball milling (SABM). Single phase tetragonal structure was characterized for the samples before and after SABM by X-ray diffraction (XRD). The thickness and length of the as-milled flakes are mainly in the range of 50–150 nm and 0.5–2 μm, respectively. For the field-aligned Pr{sub 2}Fe{sub 14}B nanoflakes, the out-of-plane texture (the easy magnetization direction (EMD) along the c-axis) is indicated from the increasing (00l) peaks in the XRD patterns. SEM image demonstrates that the EMD is parallel to flaky surface, which is different from the RCo{sub 5} (R = rare earth) system with EMD perpendicular to the surface. We propose a hypothesis that the easy glide planes are related with the area of crystal planes. In addition, a large coercivity H{sub c} = 3.9 kOe is observed in the Pr{sub 2}Fe{sub 14}B flakes with strong texture.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

THE FIRST OBSERVATIONS OF LOW-REDSHIFT DAMPED Ly{alpha} SYSTEMS WITH THE COSMIC ORIGINS SPECTROGRAPH

We report on the first Cosmic Origins Spectrograph observations of damped Ly{alpha} systems (DLAs) and sub-damped Ly{alpha} systems (sub-DLAs) discovered in a new survey of the gaseous halos of low-redshift galaxies. From observations of 37 sightlines, we have discovered three DLAs and four sub-DLAs. We measure the neutral gas density {Omega}{sub HI}, and redshift density d N/d z, of DLA and sub-DLA systems at z < 0.35. We find d N/dz = 0.25{sup +0.24}-{sub 0.14} and {Omega}{sub HI} = 1.4{sup +1.3}{sub -0.7} x 10{sup -3} for DLAs, and d N/d z = 0.08{sup +0.19}{sub -0.06} with {Omega}{sub HI} = 4.2{sup +9.6}{sub -3.5} x 10{sup -5} for sub-DLAs over a redshift path {Delta}z = 11.9. To demonstrate the scientific potential of such systems, we present a detailed analysis of the DLA at z{sub abs} = 0.1140 in the spectrum of SDSS J1009+0713. Profile fits to the absorption lines determine log N(H I) = 20.68 {+-} 0.10 with a metallicity determined from the undepleted element sulfur of [S/H] = -0.62 {+-} 0.18. The abundance pattern of this DLA is similar to that of higher z DLAs, showing mild depletion of the refractory elements Fe and Ti with [S/Fe] = +0.24 {+-} 0.22 and [S/Ti] = +0.28 {+-} 0.15. Nitrogen is underabundant in this system with [N/H] = -1.40 {+-} 0.14, placing this DLA below the plateau of the [N/{alpha}] measurements in the local universe at similar metallicities. This DLA has a simple kinematic structure with only two components required to fit the profiles and a kinematic width of {Delta}v{sub 90} = 52 km s{sup -1}. Imaging of the QSO field with the Hubble Space Telescope/Wide Field Camera 3 reveals a spiral galaxy at very small impact parameter to the QSO and several galaxies within 10'', or 20 comoving kpc at the redshift of the DLA. Follow-up spectra with the Low Resolution Imaging Spectrometer on the Keck telescope reveal that none of the nearby galaxies are at the redshift of the DLA. The spiral galaxy is identified as the host galaxy of the QSO based on the near perfect alignment of the nucleus and disk of the galaxy as well as spectra of an H II region showing emission lines at the QSO redshift. A small feature appears 0.''70 from the nucleus of the QSO after point-spread function subtraction, providing another candidate for the host galaxy of the DLA system. Even with these supporting data, we are unable to unambiguously identify the host galaxy of the DLA, exemplifying some of the difficulties in determining DLA hosts even at low redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Multifrequency Ultra-High Resolution Miniature Scanning Microscope Using Microchannel And Solid-State Sensor Technologies And Method For Scanning Samples

A miniature, ultra-high resolution, and color scanning microscope using microchannel and solid-state technology that does not require focus adjustment. One embodiment includes a source of collimated radiant energy for illuminating a sample, a plurality of narrow angle filters comprising a microchannel structure to permit the passage of only unscattered radiant energy through the microchannels with some portion of the radiant energy entering the microchannels from the sample, a solid-state sensor array attached to the microchannel structure, the microchannels being aligned with an element of the solid-state sensor array, that portion of the radiant energy entering the microchannels parallel to the microchannel walls travels to the sensor element generating an electrical signal from which an image is reconstructed by an external device, and a moving element for movement of the microchannel structure relative to the sample. Discloses a method for scanning samples whereby the sensor array elements trace parallel paths that are arbitrarily close to the parallel paths traced by other elements of the array.

Wang, Yu↗

Mechanical Design of NESSI: New Mexico Tech Extrasolar Spectroscopic Survey Instrument

NESSI: the New Mexico Tech Extrasolar Spectroscopic Survey Instrument is a ground-based multi-object spectrograph that operates in the near-infrared. It will be installed on one of the Nasmyth ports of the Magdalena Ridge Observatory (MRO) 2.4-meter Telescope sited in the Magdalena Mountains, about 48 km west of Socorro-NM. NESSI operates stationary to the telescope fork so as not to produce differential flexure between internal opto-mechanical components during or between observations. An appropriate mechanical design allows the instrument alignment to be highly repeatable and stable for both short and long observation timescales, within a wide-range of temperature variation. NESSI is optically composed of a field lens, a field de-rotator, re-imaging optics, an auto-guider and a Dewar spectrograph that operates at LN2 temperature. In this paper we report on NESSI's detailed mechanical and opto-mechanical design, and the planning for mechanical construction, assembly, integration and verification.

exoplanet↗

Novel pore size-controlled, susceptibility matched, 3D-printed MRI phantoms

We report the design concept and fabrication of MRI phantoms, containing blocks of aligned microcapillaires that can be stacked into larger arrays to construct diameter distribution phantoms or fractured, to create a “powder-averaged” emulsion of randomly oriented blocks for vetting or calibrating advanced MRI methods, that is, diffusion tensor imaging, AxCaliber MRI, MAP-MRI, and multiple pulsed field gradient or double diffusion-encoded microstructure imaging methods. The goal was to create a susceptibility-matched microscopically anisotropic but macroscopically isotropic phantom with a ground truth diameter that could be used to vet advanced diffusion methods for diameter determination in fibrous tissues. Two-photon polymerization, a novel three-dimensional printing method is used to fabricate blocks of capillaries. Double diffusion encoding methods were employed and analyzed to estimate the expected MRI diameter. Susceptibility-matched microcapillary blocks or modules that can be assembled into large-scale MRI phantoms have been fabricated and measured using advanced diffusion methods, resulting in microscopic anisotropy and random orientation. This phantom can vet and calibrate various advanced MRI methods and multiple pulsed field gradient or diffusion-encoded microstructure imaging methods. We demonstrated that two double diffusion encoding methods underestimated the ground truth diameter.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

RESOLVING THE DUST DISK IN THE PROTOTYPE IONIZED DISK WIND SOURCE S140-IRS1

The dust disk confirming the presence of an ionized disk wind in the massive young stellar object, S140-IRS1, is resolved for the first time. The 1.3 mm continuum observations taken with the CARMA A array configuration achieve a resolution of ∼0.''12, probing scales of 100 au. The dust disk is elongated in a direction aligned with a previously discovered ionized disk wind. Both are perpendicular to the large scale molecular outflow and near-infrared reflection nebula. A two-dimensional axis-symmetric radiative transfer model is used to produce synthetic images and visibilities for comparison with the observations. Using a 2D visibility fitting method the position angle of the dusty disk is constrained to 40° ± 5°. This result confirms the disk wind nature of the radio emission from S140-IRS1 and shows that radiation pressure on the gas in the disk is important in the later stages of the massive star formation evolutionary sequence.

79 ASTRONOMY AND ASTROPHYSICS↗

Pose Estimation for the Inspecta Project

In this addendum report we take the lessons learned from our initial generic object pose estimation research described in (Smartt, et al., 2025) and apply it to metal cup seals, which are attached to items after an international nuclear safeguards inspection (i.e., metal cup seals may be attached to containers of spent nuclear fuel after an inspector has measured and verified the material). We have also refined our software pipeline and training techniques since the final Inspecta report and will describe that process here. The objective of this task is to allow a robot to acquire images of the engraved seal characters to confirm that the correct seal is attached to the correct container. However, the seal may be attached in any orientation and therefore the robot manipulator arm with a camera needs to align with the normal face of the seal.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

MAPPING THE POLARIZATION OF THE RADIO-LOUD Ly α NEBULA B3 J2330+3927

Ly α nebulae, or “Ly α blobs,” are extended (up to ∼100 kpc), bright (L{sub Lyα} ≳ 10{sup 43} erg s{sup −1}) clouds of Ly α emitting gas that tend to lie in overdense regions at z ∼ 2–5. The origin of the Ly α emission remains unknown, but recent theoretical work suggests that measuring the polarization might discriminate among powering mechanisms. Here we present the first narrowband imaging polarimetry of a radio-loud Ly α nebula, B3 J2330+3927, at z = 3.09, with an embedded active galactic nucleus (AGN). The AGN lies near the blob’s Ly α emission peak, and its radio lobes align roughly with the blob’s major axis. With the SPOL polarimeter on the 6.5 m MMT telescope, we map the total (Ly α + continuum) polarization in a grid of circular apertures of a radius of 0.″6 (4.4 kpc), detecting a significant (>2 σ ) polarization fraction P {sub %} in nine apertures and achieving strong upper limits (as low as 2%) elsewhere. P{sub %} increases from <2% at ∼5 kpc from the blob center to 17% at ∼15–25 kpc. The detections are distributed asymmetrically, roughly along the nebula’s major axis. The polarization angles θ are mostly perpendicular to this axis. Comparing the Ly α flux to that of the continuum and conservatively assuming that the continuum is highly polarized (20%–100%) and aligned with the total polarization, we place lower limits on the polarization of the Ly α emission P{sub %,Lyα} ranging from no significant polarization at ∼5 kpc from the blob center to 3%–17% at 10–25 kpc. Like the total polarization, the Ly α polarization detections occur more often along the blob’s major axis.

79 ASTRONOMY AND ASTROPHYSICS↗

The magnetic field geometry in the vicinity of HH 7-11/HH 12 and HH 33/HH 40

The small-scale structure of the interstellar magnetic field in the vicinity of the Herbig-Haro objects HH 7-11/HH 12 and HH 33/40 is derived from CCD imaging polarimetry of stars nearby to these young stellar object driven outflows. The outflow associated with SVS 13/HH 7-11 lies approximately parallel to the local field direction. The outflow mapped by HH 33/HH 40 is also well aligned with the local magnetic field. However, the orientation of the outflow associated with HH 12 located 2 arcmin to the north of HH 7-11 is offset from the inferred magnetic field direction by 60 deg. These results taken together with those of previous studies suggest: (1) magnetic fields are directly or indirectly responsible for the observed orientation of outflows associated with newborn stars in the majority of cases; and (2) in some cases, the flow properties may depend upon other characteristics of the parent cloud core.

Heyer, Mark H.↗