Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image coding”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

The effects of microstructure on propagation of laser-driven radiative heat waves in under-dense high-Z plasma

This work was motivated by previous findings that the measured laser-driven heat front propagation velocity in under-dense TiO 2 /SiO 2 foams is slower than the simulated one [Pérez et al., Phys. Plasmas 21, 023102 (2014)]. In attempting to test the hypothesis that these differences result from effects of the foam microstructure, we designed and conducted an experiment on the GEKKO laser using an x-ray streak camera to compare the heat front propagation velocity in “equivalent” gas and foam targets, that is, targets that have the same initial density, atomic weight, and average ionization state. In this article, we first discuss the design and the results of this comparison experiment. To supplement the x-ray streak camera data, we designed and conducted an experiment on the Trident laser using a new high-resolution, time-integrated, spatially resolved crystal spectrometer to image the Ti K-shell spectrum along the laser-propagation axis in an under-dense TiO 2 /SiO 2 foam cylinder. We discuss the details of the design of this experiment, and present the measured Ti K-shell spectra compared to the spectra simulated with a detailed superconfiguration non-LTE atomic model for Ti incorporated into a 2D radiation hydrodynamic code. Finally, we show that there is indeed a microstructure effect on heat front propagation in under-dense foams, and that the measured heat front velocities in the TiO 2 /SiO 2 foams are consistent with the analytical model of Gus'kov et al. [Phys. Plasmas 18, 103114 (2011)].

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Using LGI experiments to achieve better understanding of pedestal-edge coupling in NSTX-U

PowerPoint presentation. Latest advances in granule or dust injection technologies, fast and high-resolution imaging, together with micro-/nano-structured material fabrication, provide new opportunities to examine plasma-material interaction (PMI) in magnetic fusion environment. Some of our previous work in these areas is summarized. The upcoming LGI experiments in NSTX-U will shed new light on granular matter transport in the pedestal-edge region. In addition to particle control, these results can also be used for code validation and achieving better understanding of pedestal-edge coupling in fusion plasmas in both NSTX-U and others.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-I-01: A Fast, Analytical Pencil Beam Based Method for First Order X-Ray Scatter Estimation of Kilovoltage Cone Beam X-Rays

Purpose: To analytically estimate first-order x-ray scatter for kV cone beam x-ray imaging with high computational efficiency. Methods: In calculating first-order scatter using the Klein-Nishina formula, we found that by integrating the point-to-point scatter along an interaction line, a “pencil-beam” scatter kernel (BSK) can be approximated to a quartic expression when the imaging field is small. This BSK model for monoenergetic, 100keV x-rays has been verified on homogeneous cube and cylinder water phantoms by comparing with the exact implementation of KN formula. For heterogeneous medium, the water-equivalent length of a BSK was acquired with an improved Siddon's ray-tracing algorithm, which was also used in calculating pre- and post- scattering attenuation. To include the electron binding effect for scattering of low-kV photons, the mean corresponding scattering angle is determined from the effective point of scattered photons of a BSK. The behavior of polyenergetic x-rays was also investigated for 120kV x-rays incident to a sandwiched infinite heterogeneous slab phantom, with the electron binding effect incorporated. Exact computation and Monte Carlo simulations were performed for comparisons, using the EGSnrc code package. Results: By reducing the 3D volumetric target (o(n{sup 3})) to 2D pencil-beams (o(n{sup 2})), the computation expense can be generally lowered by n times, which our experience verifies. The scatter distribution on a flat detector shows high agreement between the analytic BSK model and exact calculations. The pixel-to-pixel differences are within (-2%, 2%) for the homogeneous cube and cylinder phantoms and within (0, 6%) for the heterogeneous slab phantom. However, the Monte Carlo simulation shows increased deviation of the BSK model toward detector periphery. Conclusion: The proposed BSK model, accommodating polyenergetic x-rays and electron binding effect at low kV, shows great potential in efficiently estimating the first-order scatter from small imaging fields. We are investigating more thoroughly to improve performance and explore applications.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-523: Investigation of Various MR-Compatible Shielding Materials for Direction Modulated Brachytherapy (DMBT) Tandem Applicator for Cervical Cancer Treatment

Purpose: To evaluate various shielding materials such as Gold (Au), Osmium (Os), Tantalum (Ta), and Tungsten (W) based alloys for use with a novel intensity modulation capable direction modulated brachytherapy (DMBT) tandem applicator for image guided cervical cancer HDR brachytherapy. Methods: The novel MRI-compatible DMBT tandem, made from nonmagnetic tungsten-alloy rod with diameter of 5.4 mm, has 6 symmetric peripheral holes of 1.3 mm diameter with 2.05 mm distance from the center for a high degree intensity modulation capacity. The 0.3 mm thickness of bio-compatible plastic tubing wraps the tandem. MCNPX was used for Monte Carlo simulations of the shields and the mHDR Ir-192 V2 source. MC-generated 3D dose matrices of different shielding materials of Au, Os, Ta, and W with 1 mm3 resolution were imported into an in-house-coded inverse optimization planning system to evaluate 19 clinical patient plans. Prescription dose was 15Gy. All plans were normalized to receive the same HRCTV D90. Results: In general, the plan qualities for various shielding materials were similar. The OAR D2cc for bladder was very similar for Au, Os, and Ta with 11.64±2.30Gy. For W, it was very close 11.65±2.30Gy. The sigmoid D2cc was 9.82±2.46Gy for Au and Os while it was 9.84±2.48Gy for Ta and W. The rectum D2cc was 7.44±3.06Gy for Au, 7.43±3.07Gy for Os, 7.48±3.05Gy for Ta, and 7.47±3.05Gy for W. The HRCTV D98 and V100 were very close with 16.37±1.87 Gy and 97.37±1.93 Gy, on average, respectively. Conclusion: Various MRI-compatible shielding alloys were investigated for the DMBT tandem applicator. The clinical plan qualities were not significantly different among these various alloys, however. Therefore, the candidate metals (or in combination) can be used to select best alloys for MRI image guided cervical cancer brachytherapy using the novel DMBT applicator that is capable of unprecedented level of intensity modulation.

60 APPLIED LIFE SCIENCES↗

Multimode turbulent flow measurements using magnetic resonance imaging- and laser-based techniques and computational fluid dynamics simulations

We studied the flow field characteristics of a turbulent flow over a regularized cube array with a perpendicular injection flow through the floor between the second and third cubical elements, representing the complex flow interactions of a 3D jet and the wake flows behind cubical obstacles. Four different experimental measurements were performed: two magnetic resonance imaging-based measurements for three-dimensional three-component velocity (MRV) and concentration (MRC) and two laser-based techniques, particle image velocimetry (PIV) and planar laser-induced fluorescence (PLIF), for two-dimensional two-component velocity and concentration measurement, respectively. The mainstream Reynolds number is Re = 15 000⁠, based on the primary inlet velocity U m and channel height D H ⁠, whereas the injector Reynolds number is Re j = 3400⁠, based on the injector velocity U j and the injector's exit width D j ⁠. Numerical simulations were performed for the studied flow configuration of turbulent flow over a regularized cube array using Reynolds-averaged Navier–Stokes (RANS) and large-eddy simulation (LES) approaches. Results obtained from experimental measurements—including MRV, MRC, PIV, and PLIF—as well as RANS and LES simulations are discussed and compared along several horizontal and vertical planes of the studied configuration. In addition, 3D turbulent flow structures, such as leading-edge vortex, horseshoe vortex, and jet shear-layer vortex, and the isosurfaces of scalar concentration successfully revealed by MRV and MRC techniques were found to be in very good agreement with those 3D features extracted from RANS and LES simulations. In conclusion, the high-resolution experimental and numerical database obtained from this study could be useful for validation and verification of numerical codes.

Computational fluid dynamics↗

Practical galaxy morphology tools from deep supervised representation learning

Astronomers have typically set out to solve supervised machine learning problems by creating their own representations from scratch. We show that deep learning models trained to answer every Galaxy Zoo DECaLS question learn meaningful semantic representations of galaxies that are useful for new tasks on which the models were never trained. We exploit these representations to outperform several recent approaches at practical tasks crucial for investigating large galaxy samples. The first task is identifying galaxies of similar morphology to a query galaxy. Given a single galaxy assigned a free text tag by humans (e.g. ‘#diffuse’), we can find galaxies matching that tag for most tags. The second task is identifying the most interesting anomalies to a particular researcher. Our approach is 100 per cent accurate at identifying the most interesting 100 anomalies (as judged by Galaxy Zoo 2 volunteers). The third task is adapting a model to solve a new task using only a small number of newly labelled galaxies. Models fine-tuned from our representation are better able to identify ring galaxies than models fine-tuned from terrestrial images (ImageNet) or trained from scratch. We solve each task with very few new labels; either one (for the similarity search) or several hundred (for anomaly detection or fine-tuning). This challenges the longstanding view that deep supervised methods require new large labelled data sets for practical use in astronomy. To help the community benefit from our pretrained models, we release our fine-tuning code zoobot. Zoobot is accessible to researchers with no prior experience in deep learning.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-206-05: A Comparison of Head Phantoms Used for Dose Determination in Imaging Procedures

Purpose: To determine similarities and differences between various head phantoms that might be used for dose measurements in diagnostic imaging procedures. Methods: We chose four frequently used anthropomorphic head phantoms (SK-150, PBU-50, RS-240T and Alderson Rando), a computational patient phantom (Zubal) and the CTDI head phantom for comparison in our study. We did a CT scan of the head phantoms using the same protocol and compared their dimensions and CT numbers. The scan data was used to calculate dose values for each of the phantoms using EGSnrc Monte Carlo software. An .egsphant file was constructed to describe these phantoms using a Visual C++ program for DOSXYZnrc/EGSnrc simulation. The lens dose was calculated for a simulated CBCT scan using DOSXYZnrc/EGSnrc and the calculated doses were validated with measurements using Gafchromic film and an ionization chamber. Similar calculations and measurements were made for PA radiography to investigate the attenuation and backscatter differences between these phantoms. We used the Zubal phantom as the standard for comparison since it was developed based on a CT scan of a patient. Results: The lens dose for the Alderson Rando phantom is around 9% different than the Zubal phantom, while the lens dose for the PBU-50 phantom was about 50% higher, possibly because its skull thickness and the density of bone and soft tissue are lower than anthropometric values. The lens dose for the CTDI phantom is about 500% higher because of its totally different structure. The entrance dose profiles are similar for the five anthropomorphic phantoms, while that for the CTDI phantom was distinctly different. Conclusion: The CTDI and PBU-50 head phantoms have substantially larger lens dose estimates in CBCT. The other four head phantoms have similar entrance dose with backscatter hence should be preferred for dose measurement in imaging procedures of the head. Partial support from NIH Grant R01-EB002873 and Toshiba Medical Systems Corp.

60 APPLIED LIFE SCIENCES↗

Initial Investigation of the Small Feature Detection Capability of the ORNL Fast Neutron Tomographic Imaging System

A variety of fast neutron imaging simulations and measurements were performed to investigate the spatial resolution and small feature detection capability of a version of the Oak Ridge National Laboratory fast neutron tomographic imaging system. Two image quality indicators were examined: (1) a variety of long steel pins embedded axially in the interior of a polyethylene cylinder, and (2) a variety of short steels pins embedded radially in the surface of a polyethylene cylinder. Measurements demonstrated detectability of about 3 mm. Further data analysis may show improved detection performance and allow a more precise determination of the spatial resolution. Our current simulation code takes only partial consideration of the DT generator neutron production spot size, with neutron production effectively originating at a single point. Simulations showed that features less than 2 mm should be detectable with an improved generator. Our current ING-27 DT generator has a neutron production spot size of about 3.5 mm, which appears to be the limiting factor at present. Generators with spot sizes as small as 1 mm are commercially available. Higher-power, small–spot size associated particle generators are at the prototype stage and are expected to be commercially available soon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NON-LTE INVERSIONS OF THE Mg ii h and k AND UV TRIPLET LINES

The Mg ii h and k lines are powerful diagnostics for studying the solar chromosphere. They have become particularly popular with the launch of the Interface Region Imaging Spectrograph ( IRIS ) satellite, and a number of studies that include these lines have lead to great progress in understanding chromospheric heating, in many cases thanks to the support from 3D MHD simulations. In this study, we utilize another approach to analyze observations: non-LTE inversions of the Mg ii h and k and UV triplet lines including the effects of partial redistribution. Our inversion code attempts to construct a model atmosphere that is compatible with the observed spectra. We have assessed the capabilities and limitations of the inversions using the FALC atmosphere and a snapshot from a 3D radiation-MHD simulation. We find that Mg ii h and k allow reconstructing a model atmosphere from the middle photosphere to the transition region. We have also explored the capabilities of a multi-line/multi-atom setup, including the Mg ii h and k, the Ca ii 854.2 nm, and the Fe i 630.25 lines to recover the full stratification of physical parameters, including the magnetic field vector, from the photosphere to the chromosphere. Finally, we present the first inversions of observed IRIS spectra from quiet-Sun, plage, and sunspot, with very promising results.

79 ASTRONOMY AND ASTROPHYSICS↗

Evaluation of Shot-to-Shot In-Nozzle Flow Variations in a Heavy-Duty Diesel Injector Using Real Nozzle Geometry

Cyclic variability in internal combustion engines (ICEs) arises from multiple concurrent sources, many of which remain to be fully understood and controlled. This variability can, in turn, affect the behavior of the engine resulting in undesirable deviations from the expected operating conditions and performance. Shot-to-shot variation during the fuel injection process is strongly suspected of being a source of cyclic variability. This study focuses on the shot-to-shot variability of injector needle motion and its influence on the internal nozzle flow behavior using diesel fuel. High-speed x-ray imaging techniques have been used to extract high-resolution injector geometry images of the sac, orifices, and needle tip that allowed the true dynamics of the needle motion to emerge. These measurements showed high repeatability in the needle lift profile across multiple injection events, while the needle radial displacement was characterized by a much higher degree of randomness. A robust and previously validated computational setup from the authors’ research group using a commercial computational fluid dynamics (CFD) code has been adapted for the eight-hole heavy-duty common-rail diesel injector used for the measurements. The simulation results obtained using the x-ray-scanned geometry have been validated against available experimental data of mass flow rate at the nozzle exit. The fuel mass flow rate has then been analyzed at three different injection pressures that cover the conditions at which the injector typically operates during normal engine operation. Finally, the average off-axis motion of the needle has been perturbed (based on the variability found in the experimental measurements) to generate three new cases that present different amplitude and phasing of the radial displacement with respect to the baseline average motion. Furthermore, this revealed the effects of off-axis motion on shot-to-shot and orifice-to-orifice variations.

42 ENGINEERING↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogeneities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogeneities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogeneities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogenities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

ICME and In-Situ Process Monitoring for Rapid Qualification of Components Made by Laser-based Powder Bed Additive Manufacturing Processes for Nuclear Structural Applications

Additive manufacturing (AM) through selective powder bed melting of successive layers is being considered as disruptive technology for rapid production of low-cost nuclear reactor internal components with complex geometries. However, there is a potential for non-uniform distribution of physical features, such as porosity or microstructural differences, due to variations of temperature across a component build. These heterogenities make the deployment of traditional material qualification and non-destructive evaluation of AM components difficult. This research project explored the feasibility of using in-situ process monitoring methods and integrated computational materials engineering (ICME) principles as an alternate qualification methodology and approach. This project included six individual tasks: (i) design of artifacts relevant to the nuclear power industry, (ii) evaluation of laser processing and in-situ measurements, (iii) computational modeling, (iv) ex-situ microstructural characterization, (v) evaluation of scaling the methodology for large-scale structures, and (vi) development of a data package to codes and standards organizations. As a part of this research, laser powder bed fusion of metals (316L, Alloy 718, and Ti6Al4V) was explored. This document provides an overview of the research performed over three years and serves as the final U.S. Department of Energy report for this project. In the third year, the project focused on the following activities: (a) in-situ infrared and optical imaging of each layer during processing of representative stainless steel geometries; (b) development of methodologies to analyze the data; and (c) application of ICME methodologies and other experiments to estimate the relevance of defects and microstructure to tensile properties.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

SU-E-T-786: Utility of Gold Wires to Optimize Intensity Modulation Capacity of a Novel Directional Modulated Brachytherapy Tandem Applicator for Image Guided Cervical Cancer Brachytherapy

Purpose: To evaluate the impact of using gold wires to differentially fill various channels on plan quality compared with conventional T&R applicator, inside a novel directional modulated brachytherapy (DMBT) tandem applicator for cervical cancer brachytherapy. Materials and Methods: The novel DMBT tandem applicator has a 5.4-mm diameter MR-compatible tungsten alloy enclosed in a 0.3-mm thick plastic tubing that wraps around the tandem. To modulate the radiation intensity, 6 symmetric peripheral holes of 1.3-mm diameter are grooved along the tungsten alloy rod. These grooved holes are differentially filled with gold wires to generate various degrees of directional beams. For example, three different fill patterns of 1) all void, 2) all filled except the hole containing the 192-Ir source, and 3) two adjacent holes to the 192-Ir source filled were Monte Carlo simulated. The resulting 3D dose distributions were imported into an in-house-coded inverse optimization planning system to generate HDR brachytherapy clinical plans for 19 patient cases. All plans generated were normalized to the same D90 as the clinical plans and D2cc doses of OARs were evaluated. Prescription ranged between 15 and 17.5Gy. Results: In general, the plans in case 1) resulted in the highest D2cc doses for the OARs with 11.65±2.30Gy, 7.47±3.05Gy, and 9.84±2.48Gy for bladder, rectum, and sigmoid, respectively, although the differences were small. For the case 2), D2cc doses were 11.61±2.29Gy, 7.41±3.07Gy, and 9.75±2.45Gy, respectively. And, for the case 3), D2cc doses were 11.60±2.28Gy, 7.41±3.05Gy, and 9.74±2.45Gy, respectively. Difference between 1) and 2) cases were small with the average D2cc difference of <0.64%. Difference between 1) and 3) cases were even smaller with the average D2cc difference of <0.1%. Conclusions: There is a minimal clinical benefit by differentially filling grooved holes in the novel DMBT tandem applicator for image guided cervical cancer brachytherapy.

60 APPLIED LIFE SCIENCES↗

THE PROPER MOTION OF PALOMAR 5

Palomar 5 (Pal 5) is a faint halo globular cluster associated with narrow tidal tails. It is a useful system to understand the process of tidal dissolution, as well as to constrain the potential of the Milky Way. A well-determined orbit for Pal 5 would enable detailed study of these open questions. We present here the first CCD-based proper motion measurement of Pal 5 obtained using SDSS as a first epoch and new Large Binocular Telescope/Large Binocular Camera (LBC) images as a second, giving a baseline of 15 years. We perform relative astrometry, using SDSS as a distortion-free reference, and images of the cluster and also of the Pal 5 stream for the derivation of the distortion correction for LBC. The reference frame is made up of background galaxies. We correct for differential chromatic refraction using relations obtained from SDSS colors as well as from flux-calibrated spectra, finding that the correction relations for stars and for galaxies are different. We obtain μ{sub α} = −2.296 ± 0.186 mas yr{sup −1} and μ{sub δ} = −2.257 ± 0.181 mas yr{sup −1} for the proper motion of Pal 5. We use this motion, and the publicly available code galpy, to model the disruption of Pal 5 in different Milky Way models consisting of a bulge, a disk, and a spherical dark matter halo. Our fits to the observed stream properties (streak and radial velocity gradient) result in a preference for a relatively large Pal 5 distance of around 24 kpc. A slightly larger absolute proper motion than what we measure also results in better matches but the best solutions need a change in distance. We find that a spherical Milky Way model, with V{sub 0} = 220 km s{sup −1} and V{sub 20} {sub kpc}, i.e., approximately at the apocenter of Pal 5, of 218 km s{sup −1}, can match the data well, at least for our choice of disk and bulge parametrization.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-C-BRB-05: Investigation of Conformal Arc Therapy Utilizing Newly Designed Cobalt 60 Machine

Purpose: A new modernized design for cobalt 60 (Co-60) machines is being developed with a ring type gantry. In this study we investigate the beneficial outcome of the new design for conformal arc therapy for various clinical sites. The new modality was evaluated based on isodose distributions and dose volume histograms as compared to 6MV photon beams from conventional linear accelerators. Methods: Computed tomographic images of seven different SBRT patients were selected from our patient database. All of these cases were previously planned on the Eclipse treatment planning system. New plans for these patients were generated with a modified conformal arc technique using both 6MV and Co-60 beams. The conformal arc was created by the delivery of treatment fields conformal to the target cross-section at every 5 or 10 degrees. The field shape was modified or turned off when it initially passed through a critical structure. Monte Carlo codes, MCBEAM and MCPLAN, were used for the machine head simulation and phantom/patient dose calculation, respectively. In the new Co-60 machine design, the source-to-isocenter distance was 60cm and the treatment head included the Co-60 source, primary collimator, jaws and MLC. Results: For all cases investigated, conformal arc plans utilizing Co-60 beams achieved similar conformity (mean conformity index=1.19) comparing to 6MV photon beams. Isodose distributions were tailored similarly around the PTV; both Co-60 and 6MV plans met our clinical acceptance criteria for the target coverage, and the maximum and minimum target doses. The DVH for the Co-60 plans showed slightly lower doses to the critical structures although the differences were small in most cases. Conclusion: There were no significant dosimetric differences between 6MV and Co-60 plans. Our results confirmed that this new Co-60 design could be a cost-effective machine for advanced radiotherapy due to its low cost, low maintenance and high up time.

60 APPLIED LIFE SCIENCES↗