Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear Technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Beam delivery and beamstrahlung considerations for ultra-high energy linear colliders

As part of the Snowmass'21 community planning excercise, the Advanced Accelerator Concepts (AAC) community proposed future linear colliders with center-of-mass energies up to 15 TeV and luminosities up to 50 × 1034 cm -2 s -1 in a compact footprint. In addition to being compact, these machines must also be energy efficient. We identify two challenges that must be addressed in the design of these machines. First, the Beam Delivery System (BDS) must not add significant length to the accelerator complex. Second, beam parameters must be chosen to mitigate beamstrahlung effects and maximize the luminosity-per-power of the machine. In this paper, we review advances in plasma lens technology that will help to reduce the length of the BDS system, and we detail new Particle-in-Cell simulation studies that will provide insight into beamstrahlung mitigation techniques. We apply our analysis to both $e$ + $e$ - and $γγ$ colliders. The challenges and solutions described in this paper are considered independently. In conclusion, a unified, self-consistent concept for a BDS system for a 15 TeV linear collider will be the subject of future work.

47 OTHER INSTRUMENTATION↗

NDCX-II, A New Induction Linear Accelerator for Warm Dense Matter Research

The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL), a collaboration between Lawrence Berkeley National Laboratory (LBNL), Lawrence Livermore National Laboratory (LLNL), and Princeton Plasma Physics Laboratory (PPPL), is currently constructing a new induction linear accelerator, called Neutralized Drift Compression eXperiment NDCX-II. The accelerator design makes effective use of existing components from LLNL's decommissioned Advanced Test Accelerator (ATA), especially induction cells and Blumlein voltage sources that have been transferred to LBNL. We have developed an aggressive acceleration 'schedule' that compresses the emitted ion pulse from 500 ns to 1 ns in just 15 meters. In the nominal design concept, 30 nC of Li{sup +} are accelerated to 3.5 MeV and allowed to drift-compress to a peak current of about 30 A. That beam will be utilized for warm dense matter experiments investigating the interaction of ion beams with matter at high temperature and pressure. Construction of the accelerator will be complete within a period of approximately two and a half years and will provide a worldwide unique opportunity for ion-driven warm dense matter experiments as well as research related to novel beam manipulations for heavy ion fusion drivers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control

This is the final report for the project “All-Digital Plug and Play Passive RFID Sensors for Energy Efficient Building Control”, funded by DOE, and performed by Clemson University, Phase IV Engineering and Harvard University from October 1, 2016 to December 31, 2020. The main objective of this project is to develop, demonstrate and pre-commercialize a novel, plug & play, battery-free, wireless sensor technology to enable low-cost (<$10 per node) indoor and outdoor temperature and humidity measurement for energy efficient building controls and operations. The proposed technology is based on the novel concept of all-digital sensing and its seamless integration with the passive RFID technology. This project focuses on the design, fabrication, material optimization, interrogation electronics, validation, and demonstration of the novel sensor nodes for building applications. The specific objectives of this research program include: (1) Design, fabricate and optimize a compact, robust, and high-resolution digitizer, which could convert rotation angle into digital numbers. (2) Develop the multi-physics-based modeling and simulation of the temperature/humidity transducer to derive a rational design of the architecture, dimension, structure, materials (i.e., mechanical, electrical, thermal and hygroscopic) properties and functions of the sensor node. (3) Design, fabricate and optimize the bi-material based humidity sensitive coil which could linearly transduce the environmental relative humidity variations to rotation angles. (4) Design, fabricate and optimize an UHF RFID platform which could support long-range passive wireless communications of 8-bit digital numbers. (5) Design, fabricate and optimize the miniaturized all-digital sensor using MEMS technology. (6) Validate the integrated all-digital sensing system in a real building environment to test the system’s performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ramping up the Spallation Neutron Source beam power with the H{sup -} source using 0 mg Cs/day

This paper describes the ramp up of the beam power for the Spallation Neutron Source by ramping up the pulse length, the repetition rate, and the beam current emerging from the H{sup -} source. Starting out with low repetition rates ({<=}10 Hz) and short pulse lengths ({<=}0.2 ms), the H{sup -} source and low-energy beam transport delivered from Lawrence Berkeley National Laboratory exceeded the requirements with almost perfect availability. This paper discusses the modifications that were required to exceed 0.2 ms pulse length and 0.2% duty factor with acceptable availability and performance. Currently, the source is supporting neutron production at 1 MW with 38 mA linac beam current at 60 Hz and 0.9 ms pulse length. The pulse length will be increased to {approx}1.1 ms to meet the requirements for neutron production with a power between 1 and 1.4 MW. A medium-energy beam transport (MEBT) beam current of 46 mA with a 5.4% duty factor has been demonstrated for 32 h. A 56 mA MEBT beam current with a 4.1% duty factor has been demonstrated for 20 min at the conclusion of a 12-day production run. This is close to the 59 mA needed for 3 MW neutron productions. Also notable is the Cs{sub 2}CrO{sub 4} cesium system, which dispenses {approx}10 mg of Cs during the startup of the ion source, sufficient for producing the required 38 mA for 4 weeks without significant degradation.

43 PARTICLE ACCELERATORS↗

Modeling laser wakefield accelerator experiments with ultrafast particle-in-cell simulations in boosted frames

The development of new laser systems at the 10 Petawatt range will push laser wakefield accelerators to novel regimes, for which theoretical scalings predict the possibility to accelerate electron bunches up to tens of GeVs in meter-scale plasmas. Numerical simulations will play a crucial role in testing, probing, and optimizing the physical parameters and the setup of future experiments. Fully kinetic simulations are computationally very demanding, pushing the limits of today's supercomputers. In this paper, the recent developments in the OSIRIS framework [R. A. Fonseca et al., Lect. Notes Comput. Sci. 2331, 342 (2002)] are described, in particular the boosted frame scheme, which leads to a dramatic change in the computational resources required to model laser wakefield accelerators. Results from one-to-one modeling of the next generation of laser systems are discussed, including the confirmation of electron bunch acceleration to the energy frontier.

43 PARTICLE ACCELERATORS↗

Efficient simulation of electron trapping in laser and plasma wakefield acceleration

The two-dimensional quasistatic simulation code WAKE [P. Mora and T. Antonsen, Phys. Plasmas 4, 217 (1997)] used to model laser pulse propagation in tenuous plasma is modified to describe the dynamics of energetic particles. In the original code, all particles were assumed to satisfy the quasistatic approximation, which assumes that the driver and its wakefields are undisturbed during the transit time of plasma electrons through the pulse. Here, WAKE is modified to include the effects of electron trapping and beam loading by introducing a population of beam electrons, which are no longer subject to the quasistatic approximation. Algorithms for populating the group of beam particles are considered and are benchmarked to the full particle-in-cell simulations and experimental results. These modifications to WAKE provide a tool for simulating GeV laser or plasma wakefield acceleration on desktop computers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Injection and acceleration of quasimonoenergetic relativistic electron beams using density gradients at the edges of a plasma channel

The injection of quasimonoenergetic electron beams into a laser wakefield accelerator is demonstrated experimentally using density gradients at the edges of a plasma channel. In the experiment, two laser pulses are used; the main laser pulse drives a wakefield, while a second countercrossing laser beam produces a plasma whose expansion creates a channel with significant density gradients. Local injection of electrons in the wakefield is triggered by wave breaking in the density ramp. The injection is localized spatially and leads to the generation of collimated and narrow energy spread relativistic electron beams at the 100 MeV level, with charges in the range of 20-100 pC. The stability of this injection process is compared to the stability of the colliding pulse injection process and is found to be inferior for our experimental conditions. On the other hand, it is found that as the electron beam divergence is smaller in the case of gradient injection, the transverse emittance might be better.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Creation of persistent, straight, 2 mm long laser driven channels in underdense plasmas

The experimental study of the behavior of deuterium plasma with densities between 2x10{sup 18} and 2x10{sup 20} cm{sup -3}, subjected to a 6 TW, 30 ps, 3x10{sup 18} W cm{sup -2} laser pulse, is presented. Conclusive experimental proof that a single straight channel is generated when the laser pulse interacts with the lowest densities is provided. This channel shows no small-scale longitudinal density modulations, extends up to 2 mm in length and persists for up to 150 ps after the peak of the interaction. Bifurcation of the channel after 1 mm propagation distance is observed for the first time. For higher density interactions, above the relativistic self-focusing threshold, bubblelike structures are observed to form at late times. These observations have implications for both laser wakefield accelerators and fast ignition inertial fusion studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of multi-color attosecond x-ray radiation through modulation compression

In this paper, we propose a scheme to generate tunable multi-color attosecond coherent x-ray radiation. This scheme uses a modulation compression method to generate a multi-spike prebunched kilo-ampere peak current electron beam from a few tens ampere electron beam out of a linac. Such a beam transporting through a series of undulator radiators and bunch compressors generates multi-color coherent x-ray radiation. As an illustration, we present an example to generate two attosecond pulses with 2.2 nm and 3 nm coherent x-ray radiation wavelength and more than 200 MW peak power using a 50 A 200 nm laser seeded electron beam.

43 PARTICLE ACCELERATORS↗

Optical emission spectroscopy of the Linac4 and superconducting proton Linac plasma generators

CERN's superconducting proton Linac (SPL) study investigates a 50 Hz high-energy, high-power Linac for H{sup -} ions. The SPL plasma generator is an evolution of the DESY ion source plasma generator currently operated at CERN's Linac4 test stand. The plasma generator is a step towards a particle source for the SPL, it is designed to handle 100 kW peak RF-power at a 6% duty factor. While the acquisition of an integrated hydrogen plasma optical spectrum is straightforward, the measurement of a time-resolved spectrum requires dedicated amplification schemes. The experimental setup for visible light based on photomultipliers and narrow bandwidth filters and the UV spectrometer setup are described. The H{sub {alpha}}, H{sub {beta}}, and H{sub {gamma}} Balmer line intensities, the Lyman band and alpha transition were measured. A parametric study of the optical emission from the Linac4 ion source and the SPL plasma generator as a function of RF-power and gas pressure is presented. The potential of optical emission spectrometry coupled to RF-power coupling measurements for on-line monitoring of short RF heated hydrogen plasma pulses is discussed.

43 PARTICLE ACCELERATORS↗

A setup for resonant inelastic soft x-ray scattering on liquids at free electron laser light sources

We present a flexible and compact experimental setup that combines an in vacuum liquid jet with an x-ray emission spectrometer to enable static and femtosecond time-resolved resonant inelastic soft x-ray scattering (RIXS) measurements from liquids at free electron laser (FEL) light sources. We demonstrate the feasibility of this type of experiments with the measurements performed at the Linac Coherent Light Source FEL facility. At the FEL we observed changes in the RIXS spectra at high peak fluences which currently sets a limit to maximum attainable count rate at FELs. The setup presented here opens up new possibilities to study the structure and dynamics in liquids.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High current H{sub 2}{sup +} and H{sub 3}{sup +} beam generation by pulsed 2.45 GHz electron cyclotron resonance ion source

The permanent magnet 2.45 GHz electron cyclotron resonance ion source at Peking University can produce more than 100 mA hydrogen ion beam working at pulsed mode. For the increasing requirements of cluster ions (H{sub 2}{sup +} and H{sub 3}{sup +}) in linac and cyclotron, experimental study was carried out to further understand the hydrogen plasma processes in the ion source for the generation of cluster ions. The constituents of extracted beam have been analyzed varying with the pulsed duration from 0.3 ms to 2.0 ms (repetition frequency 100 Hz) at different operation pressure. The fraction of cluster ions dramatically increased when the pulsed duration was lower than 0.6 ms, and more than 20 mA pure H{sub 3}{sup +} ions with fraction 43.2% and 40 mA H{sub 2}{sup +} ions with fraction 47.7% were obtained when the operation parameters were adequate. The dependence of extracted ion fraction on microwave power was also measured at different pressure as the energy absorbed by plasma will greatly influence electron temperature and electron density then the plasma processes in the ion source. More details will be presented in this paper.

43 PARTICLE ACCELERATORS↗

Two-photon polarization data storage in bacteriorhodopsin films and its potential use in security applications

Bacteriorhodopsin (BR) films allow write-once-read-many recording of polarization data by a two-photon-absorption (TPA) process. The optical changes in BR films induced by the TPA recording were measured and the Müller matrix of a BR film was determined. A potential application of BR films in security technology is shown. Polarization data can be angle-selective retrieved with high signal-to-noise ratio. The BR film does not only carry optical information but serves also as a linear polarizer. This enables that polarization features recorded in BR films may be retrieved by merely using polarized light from a mobile phone display.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Performance of a beam-multiplexing diamond crystal monochromator at the Linac Coherent Light Source

A double-crystal diamond monochromator was recently implemented at the Linac Coherent Light Source. It enables splitting pulses generated by the free electron laser in the hard x-ray regime and thus allows the simultaneous operations of two instruments. Both monochromator crystals are High-Pressure High-Temperature grown type-IIa diamond crystal plates with the (111) orientation. The first crystal has a thickness of ∼100 μm to allow high reflectivity within the Bragg bandwidth and good transmission for the other wavelengths for downstream use. The second crystal is about 300 μm thick and makes the exit beam of the monochromator parallel to the incoming beam with an offset of 600 mm. Here we present details on the monochromator design and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ePix100 camera: Use and applications at LCLS

The ePix100 x-ray camera is a new system designed and built at SLAC for experiments at the Linac Coherent Light Source (LCLS). The camera is the first member of a family of detectors built around a single hardware and software platform, supporting a variety of front-end chips. With a readout speed of 120 Hz, matching the LCLS repetition rate, a noise lower than 80 e-rms and pixels of 50 µm × 50 µm, this camera offers a viable alternative to fast readout, direct conversion, scientific CCDs in imaging mode. The detector, designed for applications such as X-ray Photon Correlation Spectroscopy (XPCS) and wavelength dispersive X-ray Emission Spectroscopy (XES) in the energy range from 2 to 10 keV and above, comprises up to 0.5 Mpixels in a very compact form factor. In this paper, we report the performance of the camera during its first use at LCLS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Compact and efficient elastocaloric heat pumps—Is there a path forward?

Elastocaloric cooling holds promise for energy-efficient heat pumping near room temperature with low environmental impact. Its adoption is, however, impeded by disproportionally large sizes of actuators compared with the active material volume. Taking magnetocaloric cooling as the baseline, the value of no more than 10:1 actuator volume to active material volume should lead to both size- and cost-effective solutions that may potentially be competitive with vapor-compression devices. With the goal to establish performance metrics that can lead to informed actuator selection for specific regenerator requirements, we analyze a wide range of elastocaloric materials and actuator technologies to find the best matches. We find that actuation with magnetic shape memory alloys meets all requirements; however, this technology is currently in early developmental stages and such actuators are not widely commercially available. Another promising and easily accessible option is standard rotary electric motors in combination with rotary-to-linear transduction mechanisms. A theoretical analysis of two case studies of elastocaloric systems using rotary electric motors with a Scotch yoke mechanism demonstrates the usefulness of our approach. Actuator requirements are based on two different regenerator configurations: one starting from zero strain without any mechanical energy recovery and another with 2% pre-strain and mechanical energy recovery to reduce the power and torque required from the motor. Our results indicate that the 10:1 target actuator to active material volume ratio can be met and feasibly lowered further, demonstrating that the proposed method for selecting actuators makes compact and efficient elastocaloric systems possible.

42 ENGINEERING↗

Spectral method for the correction of the Cerenkov light effect in plastic scintillation detectors: A comparison study of calibration procedures and validation in Cerenkov light-dominated situations

Purpose: The purposes of this work were: (1) To determine if a spectral method can accurately correct the Cerenkov light effect in plastic scintillation detectors (PSDs) for situations where the Cerenkov light is dominant over the scintillation light and (2) to develop a procedural guideline for accurately determining the calibration factors of PSDs. Methods: The authors demonstrate, by using the equations of the spectral method, that the condition for accurately correcting the effect of Cerenkov light is that the ratio of the two calibration factors must be equal to the ratio of the Cerenkov light measured within the two different spectral regions used for analysis. Based on this proof, the authors propose two new procedures to determine the calibration factors of PSDs, which were designed to respect this condition. A PSD that consists of a cylindrical polystyrene scintillating fiber (1.6 mm{sup 3}) coupled to a plastic optical fiber was calibrated by using these new procedures and the two reference procedures described in the literature. To validate the extracted calibration factors, relative dose profiles and output factors for a 6 MV photon beam from a medical linac were measured with the PSD and an ionization chamber. Emphasis was placed on situations where the Cerenkov light is dominant over the scintillation light and on situations dissimilar to the calibration conditions. Results: The authors found that the accuracy of the spectral method depends on the procedure used to determine the calibration factors of the PSD and on the attenuation properties of the optical fiber used. The results from the relative dose profile measurements showed that the spectral method can correct the Cerenkov light effect with an accuracy level of 1%. The results obtained also indicate that PSDs measure output factors that are lower than those measured with ionization chambers for square field sizes larger than 25x25 cm{sup 2}, in general agreement with previously published Monte Carlo results. Conclusions: The authors conclude that the spectral method can be used to accurately correct the Cerenkov light effect in PSDs. The authors confirmed the importance of maximizing the difference of Cerenkov light production between calibration measurements. The authors also found that the attenuation of the optical fiber, which is assumed to be constant in the original formulation of the spectral method, may cause a variation of the calibration factors in some experimental setups.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-CD-209-07: Preliminary Experimental Comparison of Spot- and Continuous Line Scanning with Or Without Rescanning for Gated Proton Therapy

Purpose: We aim to compare the performance of discrete spot- or continuous line scanning combined with rescanning in mitigating residual organ motion during gated proton therapy treatments. Methods: The Quasar respiratory phantom was used to move a 2D scintillation detector on a linear trajectory with sinusoidal motion pattern (sin{sup 4}), 20 mm peak-to-peak amplitude and 5 sec period. Its motion was monitored using a customized solution based on optical tracking technology. We compared spot and line scanning plans for a monoenergetic 150 MeV circular field, 50.4 mm radius at isocenter. Transverse dose distributions at 13 cm depth in PMMA (15.47 mm water equivalent) were measured to compare three options for motion mitigation: rescanning (10× factor), gating and their combination. The gating window was centered in the trajectory plateau to simulate end-exhale gated treatment in presence of 2 mm and 4 mm residual motion, parallel or perpendicular to the primary scanning direction. Results: When the target moves perpendicular to the primary scanning direction, large dose deviations are measured (γ3%/3mm=47%) without mitigation techniques. Beam gating combined with rescanning restores target coverage (γ3%/3mm=91%). For parallel target motion, observed dose distortions in the non-compensated irradiation are smaller (γ3%/3mm=77%). Beam gating alone recovers the 100% gamma pass-rate at 3%/3mm. Continuous line scanning reduces delivery time by up to 60% with respect to discrete spot scanning in presence of motion mitigation, and improves homogeneity when rescanning is applied (up to 20%, perpendicular motion, 4 mm residual motion). Conclusion: The direction of motion has a large impact on the target dose coverage. Nevertheless, even in the worst case scenario, gating combined with rescanning could mitigate the impact of motion on dose deposition. Moreover, continuous line rescanning improves the robustness against residual motion in the gating window. This study has received funding from the European Community’s Seventh Framework Programme (FP7/2007–2013) under grant agreement n.290605 (PSI-FELLOW/COFUND) and ‘Giuliana and Giorgio Stefanini Foundation’.

60 APPLIED LIFE SCIENCES↗