Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measuring instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

GIFTS SM EDU Radiometric and Spectral Calibrations

The Geosynchronous Imaging Fourier Transform Spectrometer (GIFTS) Sensor Module (SM) Engineering Demonstration Unit (EDU) is a high resolution spectral imager designed to measure infrared (IR) radiance using a Fourier transform spectrometer (FTS). The GIFTS instrument gathers measurements across the long-wave IR (LWIR), short/mid-wave IR (SMWIR), and visible spectral bands. The raw interferogram measurements are radiometrically and spectrally calibrated to produce radiance spectra, which are further processed to obtain atmospheric profiles via retrieval algorithms. This paper describes the processing algorithms involved in the calibration. The calibration procedures can be subdivided into three categories: the pre-calibration stage, the calibration stage, and finally, the post-calibration stage. Detailed derivations for each stage are presented in this paper.

Tian, J.↗

The Alpha Particle X-Ray Spectrometer (APXS): Results from Gusev Crater and Calibration Report

The chemical composition of rocks and soils on Mars analyzed during the Mars Exploration Rover Spirit Mission was determined by X-ray analyses with the Alpha Particle X-Ray Spectrometer (APXS). Details of the data analysis method and the instrument calibration are presented. Measurements performed on Mars to address geometry effects and background contributions are shown. Cross calibration measurements among several instrument sensors and sources are discussed. An unintentional swap of the two flight instruments is evaluated. New concentration data acquired during the first 470 sols of rover Spirit in Gusev Crater are presented. There are two geological regions, the Gusev plains and the Columbia Hills. The plains contain soils that are very similar to previous landing sites on Mars. A meteoritic component in the soil is identified. Rocks in the plains revealed thin weathering rinds. The underlying abraded rock was classified as primitive basalt. One of these rocks contained significant Br that is probably associated with vein-filling material of different composition. One of the trenches showed large subsurface enrichments of Mg, S, and Br. Disturbed soils and rocks in the Columbia Hills revealed different elemental compositions. These rocks are significantly weathered and enriched in mobile elements, such as P, S, Cl, or Br. Even abraded rock surfaces have high Br concentrations. Thus, in contrast to the rocks and soils in the Gusev Plains, the Columbia Hills material shows more significant evidence of ancient aqueous alteration.

Gellert, R.↗

DMSP Spacecraft Charging in Auroral Environments

The Defense Meteorological Satellite Program (DMSP) spacecraft are a series of low-earth orbit (LEO) satellites whose mission is to observe the space environment using the precipitating energetic particle spectrometer (SSJ/4-5). DMSP satellites fly in a geosynchronous orbit at approx.840 km altitude which passes through Earth s ionosphere. The ionosphere is a region of partially ionized gas (plasma) formed by the photoionization of neutral atoms and molecules in the upper atmosphere of Earth. For satellites in LEO, such as DMSP, the plasma density is usually high and the main contributors to the currents to the spacecraft are the precipitating auroral electrons and ions from the magnetosphere as well as the cold plasma that constitutes the ionosphere. It is important to understand how the ionosphere and auroral electrons can accumulate surface charges on satellites because spacecraft charging has been the cause of a number of significant anomalies for on-board instrumentation on high altitude spacecraft. These range from limiting the sensitivity of measurements to instrument malfunction depending on the magnitude of the potential difference over the spacecraft surface. Interactive Data Language (IDL) software was developed to process SSJ/4-5 electron and ion data and to create a spectrogram of the particles number and energy fluxes. The purpose of this study is to identify DMSP spacecraft charging events and to present a preliminary statistical analysis. Nomenclature

Colson, Andrew↗

A Portable Nitrogen Dioxide Instrument Using Cavity-Enhanced Absorption Spectroscopy

The Portable (2.7 kg) Cavity-enhanced Absorption of Nitrogen Dioxide (PCAND) instrument for measuring in situ nitrogen dioxide (NO2) was developed using incoherent, broadband cavity-enhanced absorption spectroscopy (IBBCEAS). An LED light source centered at 408 nm was coupled to a cavity 15 cm in length, achieving an effective optical pathlength of ~520 m. Our precision was measured as 94 pptv (1 s). To date, we have flown this instrument on 3 balloon and 1 UAV test flights. This instrument records data to an SD card and outputs data (via an RS232 port) to external devices including a commercial radiosonde (iMet) for real-time data downlink.

TROPOMI↗

Diffusivity Measurements Made Instant and Easy

A compact common path interferometer (CPI) system has been developed to measure the diffusivity of liquid pairs. The CPI is an optical technique that can be used to measure changes in the gradient of the refraction index of transparent materials. It uses a shearing interferometer that shares the same optical path from a laser light source to the final imaging plane. The molecular diffusion coefficient of liquids can be determined from the physical relations between changes in the optical path length and liquid phase properties. When the data obtained by using the CPI have been compared with similar results from other techniques, the instrument has been demonstrated to be far superior to other instruments for measuring the diffusivity of miscible liquids while staying very compact and robust (ref. 1). Because of its compactness and ease of use, the CPI has been adopted for use in studies of interface dynamics as well as other diffusion-controlled process applications (ref. 2). This progress will permit experiments in microgravity that can quantitatively answer basic science questions about mass and thermal diffusion and their effect in transport processes. This instrument is a spinoff of a diagnostic development for microgravity fluid physics experiments at the NASA Glenn Research Center that has used optics and electronics existing in the fluid physics laboratory for feasibility studies. Optical diagnostic techniques have become an integral part of many areas of measurement applications in industrial and research laboratories. Many types of interferometers and their phase-shifted versions have been used as instruments for measuring optical wave fronts for lens testing and combustion and fluid flow diagnostics. One of these, the point diffraction interferometer, is considered to be robust (see, for example, ref. 3) because it has a common-path design. The point diffraction interferometer is difficult to align and has a limited measurement range for liquid-phase applications. Interferometry and schlieren techniques have been widely used for many years for gas-flow-visualization. On the other hand, the CPI, which is basically a Wollaston prism Polarizer in combination with an analyser (crystalline quartz retardation plate) is used instead of a point diffraction interferometer unit. The advantage of using the CPI over other optical techniques is that it can make quantitative measurements in liquids with the large index of refraction variations that often occur in interface dynamics studies. This can be simply accomplished by using different prism polarizers for each particular experimental condition.

Rashidnia, Nasser↗

Supercontinuum Stimulated Emission Depletion Fluorescence Lifetime Imaging

Supercontinuum (SC) stimulated emission depletion (STED) fluorescence lifetime imaging is demonstrated by using time-correlated single-photon counting (TCSPC) detection. The spatial resolution of the developed STED instrument was measured by imaging monodispersed 40-nm fluorescent beads and then determining their fwhm, and was 36 ± 9 and 40 ± 10 nm in the X and Y coordinates, respectively. The same beads measured by confocal microscopy were 450 ± 50 and 430 ± 30 nm, which is larger than the diffraction limit of light due to underfilling the microscope objective. Underfilling the objective and time gating the signal were necessary to achieve the stated STED spatial resolution. The same fluorescence lifetime (2.0 ± 0.1 ns) was measured for the fluorescent beads by using confocal or STED lifetime imaging. The instrument has been applied to study Alexa Fluor 594-phalloidin labeled F-actin-rich projections with dimensions smaller than the diffraction limit of light in cultured cells. Fluorescence lifetimes of the actin-rich projections range from 2.2 to 2.9 ns as measured by STED lifetime imaging.

36 MATERIALS SCIENCE↗

The atmosphere as a research window - Signal or noise

The interpretation of measurements by instruments with FOV that are large enough to contain pronounced radiometric variations is discussed, focusing on the retrieval of cloud properties from satellite radiance measurements. Examples are presented for three retrieval approaches. The use of a physical principle to establish a relationship between the measurement and the desired parameter is shown for cirrus-cloud optical depth and precipitation from passive microwave measurements. Examples of the use of inherent variability of the atmosphere and the statistical character of this variability are the spatial covariance method and the threshold method. Also, two examples using a hybrid of these two methods are presented. It is shown that the natural variability (noise) within the instrument FOV biases the relationship between the measurement and the parameter of interest which would be predicted by simple one-dimensional radiative-transfer theory. It is suggested that the noise of the measurement also contains signal, forming the basis for hybrid methods.

Stephens, Graeme L.↗

Fiber Optic Instrumentation in High Temperature Irradiation Environments

The extremely harsh conditions of advanced reactor designs pose serious challenges for nuclear fuels and materials. Traditional instrumentation (thermocouples, strain gauges, etc.) are not well suited for extended operation in such a harsh environment. This work discusses the potential for using fiber optic-based instrumentation in high temperature irradiation experiments. The primary limitation of fiber optic instrumentation in irradiation experiments is signal darkening due to attenuation in the fiber material. A computational model has been developed to predict broadband optical attenuation in fused silica fiber materials as a function of time, temperature, and dose. Preliminary results obtained using this model are shown for one cycle of irradiation in the high flux isotope reactor at various temperatures. An irradiation campaign has been initiated to provide temperature-dependent optical attenuation data at high dose in order to validate the predictive model. Demonstration of the safety and reliability of new and enhanced nuclear fuels and materials is essential for improving the safety and reliability of existing nuclear power plants and for the licensing and operation of advanced nuclear reactor technologies. Experimental validation of fuel performance codes requires high fidelity measurements during instrumented irradiation experiments. Therefore, a clear need exists for sensors of unprecedented accuracy, resolution, time/space/energy spectrum dependence, reduced size, and, perhaps most importantly, performance in harsh environments. The harsh environment during accelerated irradiation testing could include temperatures from 300 deg. C up to 2600 deg. C, and radiation damage levels ranging from 1 to greater than 100 dpa. Optical fiber-based sensors are a promising candidate for instrumentation in high temperature irradiation environments. Optical fibers are small, inexpensive, chemically inert, immune to electromagnetic interference, and made of high temperature radiation-hard materials. The ability to make distributed measurements of temperature or strain using a single inexpensive optical fiber currently exists for non-extreme environments as commercially available technology. Other advanced sensing technologies such as laser ultrasound, borescopes, and laser-induced breakdown spectroscopy use fiber optic light delivery as a critical component of the sensor design. Some potential applications for optical fiber-based sensors in instrumented irradiation experiments include in-situ measurements of thermal conductivity, ultrasonic measurement of elastic constants (with fiber optic delivery of signal for generation and detection of ultrasonic wave), and distributed measurements of temperature and/or strain (i.e., swelling). The primary limitation for the use of optical technologies for harsh environment (e.g., high neutron flux reactor environments) instrumentation is the attenuation of the light signal due to the effects of temperature and/or irradiation. This work summarizes initial efforts towards developing a predictive model of temperature-dependent radiation-induced attenuation in fused silica optical fibers at high dose. If there is adequate transmission in the fibers, fiber optic-based instrumentation could provide highly accurate distributed measurements during instrumented fuel/material irradiation experiments. Preliminary results show attenuation on the order of 5- 10 dB/m in the wavelength range of 750-900 nm at temperatures of 300 deg. C and below after one HFIR cycle (24 days). At higher temperatures (600 and 900 deg. C), the attenuation is reduced below 5 dB/m in the same wavelength range. This amount of attenuation is acceptable for most fiber optic based sensor systems with a dynamic range on the order of 20-50 dB for a reasonable length (1-2 meters) of fiber in the high flux region. Many optical components use a wavelength of 850 nm, which lies in the low attenuation window. In order to refine and ultimately validate the predictive model of optical fiber attenuation, a reactor irradiation campaign has been initiated. Rabbit irradiation capsules have been designed to irradiate optical fiber material (low and high OH fused silica, as well as single crystal sapphire) specimens in the HFIR at temperatures ranging from 100 to 1200 deg. C. (authors)

42 ENGINEERING↗

THE COSMIC INFRARED BACKGROUND EXPERIMENT (CIBER): THE WIDE-FIELD IMAGERS

We have developed and characterized an imaging instrument to measure the spatial properties of the diffuse near-infrared extragalactic background light (EBL) in a search for fluctuations from z > 6 galaxies during the epoch of reionization. The instrument is part of the Cosmic Infrared Background Experiment (CIBER), designed to observe the EBL above Earth's atmosphere during a suborbital sounding rocket flight. The imaging instrument incorporates a 2 Degree-Sign Multiplication-Sign 2 Degree-Sign field of view to measure fluctuations over the predicted peak of the spatial power spectrum at 10 arcmin, and 7'' Multiplication-Sign 7'' pixels, to remove lower redshift galaxies to a depth sufficient to reduce the low-redshift galaxy clustering foreground below instrumental sensitivity. The imaging instrument employs two cameras with {Delta}{lambda}/{lambda} {approx} 0.5 bandpasses centered at 1.1 {mu}m and 1.6 {mu}m to spectrally discriminate reionization extragalactic background fluctuations from local foreground fluctuations. CIBER operates at wavelengths where the electromagnetic spectrum of the reionization extragalactic background is thought to peak, and complements fluctuation measurements by AKARI and Spitzer at longer wavelengths. We have characterized the instrument in the laboratory, including measurements of the sensitivity, flat-field response, stray light performance, and noise properties. Several modifications were made to the instrument following a first flight in 2009 February. The instrument performed to specifications in three subsequent flights, and the scientific data are now being analyzed.

79 ASTRONOMY AND ASTROPHYSICS↗

Observation of Cosmic Gamma Ray Bursts in the Experiments Onboard Lomonosov and Vernov Satellites

The study of cosmic gamma ray bursts (GRBs) is one of the main goals of the Lomonosov space mission. The main advantage of this mission is simultaneous multiwavelength observations of GRBs covering the optical, X-ray and gamma-ray ranges. The mission payload includes the GRB monitor BDRG, wide-field optical cameras SHOK, and the UFFO instrument. Data are recorded mainly by the event trigger provided by the BDRG instrument, which measures the spectral and temporal properties of the burst in the energy range 10–3000 keV. The BDRG instrument also provides estimation of the source coordinates by comparing the readings of three differently directed detectors with an accuracy of several degrees. Wide-field SHOK optical cameras have a field of view of ~20° × 40°. They fix a set of images with a frequency of about five frames per second prior to the trigger and another set immediately after the trigger. The UFFO instrument includes the UBAT telescope with a coded mask for measurements in hard X-ray and soft gamma-ray ranges and an optical telescope with a slewing mirror (SMT) that can be directed on the GRB source for a time ~1 s for measuring GRB prompt emission in the early stages. In response to an BDRG trigger signal, the real-time data on a detected GRB are transmitted to the Earth via Globalstar network to the Gamma-ray Coordinates Network (GCN) and ground-based observatories. During observations on the Lomonosov satellite, 20 gamma-ray bursts were detected and catalogued. Several gamma-ray bursts were also detected in the Vernov satellite experiment. An example of such an event is given.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of techniques for the in situ observation of OH and HO2 for studies of the impact of high-altitude supersonic aircraft on the stratosphere

This three-year project supported the construction, calibration, and deployment of a new instrument to measure the OH and HO2 radicals on the NASA ER-2 aircraft. The instrument has met and exceeded all of its design goals. The instrumentation represents a true quantum leap in performance over that achieved in previous HO(x) instruments built in our group. Sensitivity for OH was enhanced by over two orders of magnitude as the weight fell from approximately 1500 to less than 200 Kg. Reliability has been very high: HO(x) data are available for all flights during the first operational mission, the Stratospheric Photochemistry, Aerosols, and Dynamics Expedition (SPADE). The results of that experiment have been reported in the scientific literature and at conferences. Additionally, measurements of H2O and O3 were made and have been reported in the scientific literature. The measurements demonstrated the important role that OH and HO2 play in determining the concentration of ozone in the lower stratosphere. During the SPADE, campaign the measurements demonstrated that the catalytic removal is dominated by processes involving the odd-hydrogen and halogen radicals-and extremely important constraint for photochemical models that are being used to assess the potential deleterious effects of super-sonic aircraft effluent on the burden of stratospheric ozone.

Anderson, James G.↗

Development of techniques for the In Situ observation of OH and HO2 for studies of the impact of high-altitude supersonic aircraft on the stratosphere

This three-year project supported the construction, calibration, and deployment of a new instrument to measure the OH and HO2 radicals on the NASA Er-2 aircraft. The instrument has met and exceeded all of its design goals. The instrumentation represents a true quantum leap in performance over that achieved in previous HO(x) instruments built in our group. Sensitivity of OH was enhanced by over two orders of magnitude as the weight fell from approximately 1500 to less than 200 Kg. Reliability has been very high: HO(x) data are available for all flights during the first operational mission, the Stratospheric Photochemistry, aerosols, and Dynamics Expedition (SPADE). The results of that experiment have been reported in the scientific literature and at conferences. Additionally, measurements of H2O and O3 were made and have been reported in the scientific literature. The measurements demonstrate the important role that OH and HO2 play in determining the concentration of ozone in the lower stratosphere. During the SPADE campaign, the measurements demonstrate that the catalytic removal is dominated by processes involving the odd-hydrogen and halogen radicals-an extremely important constraint for photochemical models that are being used to assess the potential deleterious effects of super-sonic aircraft effluent on the burden of stratospheric ozone.

Anderson, James G.↗

Wind measurements with the High Resolution Doppler Imager (HRDI)

The Upper Atmosphere Research Satellite (UARS), to be launched in 1989, is to provide a global data set required to understand the mechanisms controlling upper atmosphere structure and processes, as well as the response of the upper atmosphere to natural and human perturbations. The High Resolution Doppler Imager (HRDI) is the primary instrument for measuring the dynamics of the stratosphere and mesosphere. The goal of HRDI is to measure wind velocities in the stratosphere and mesosphere during the day and the mesosphere and thermosphere at night with an accuracy of 5 m/sec. HRDI will determine winds by measuring Doppler shifts of atmosphere absorption and emission features. Line of sight winds will be taken in two directions, thus allowing the wind vector to be formed. The HRDI instrument is overviewed. The basis of the measurement is explained, as is an outline of the instrument. Since neither instrument nor observational techniques is fully mature, only a brief sketch is presented.

Skinner, W. R.↗

Multi-Satellite Measurements and Model Predictions of Mesospheric and Upper Stratospheric Influences from the Very Large July 14-16, 2000, Solar Proton Event

A large solar flare with an associated coronal mass ejection occurred in mid-July and caused a very large solar proton event at the earth in the time period July 14-16, 2000. So far this is the largest solar storm of solar cycle 23. The solar proton fluxes were measured by instruments aboard the GOES-10 satellite and used in our proton energy deposition model to help quantify the energy input to the middle atmosphere during this large solar event. Using this computed energy deposition in the GSFC 2D atmospheric model resulted in a prediction of $>$ 20\% increases in HO$-(x)$ (H, OH, HO$-(2)$) and $>$ 100\% increases in NO$-(x)$ (N, NO, NO$-(2)$) constituents in the mesosphere and upper stratosphere at polar latitudes ($>$ 60 degrees geomagnetic). Both the HO$-(x)$ and NO$_fx)$ increases impacted ozone. Large atmospheric impacts have been measured with the NOAA 14 SBUV/2 instrument (0$_(3)$), the UARS HALOE instrument (NO, NO$-(2)$, 0$-(3)$), and the POAM III instrument (0$_{3}$, NO$-(2)$). Preliminary analysis indicates that measured (SBUV/2) and modelled 0$_{3}$ decreases from this solar event are generally in agreement in the Northern Hemisphere. Short-term ozone changes (during the event) indicate $\sim$ 15% reduction at 2 hPa ($\sim$ 45 km) up to $\sim$ 40% reduction at 0.5 hPa ($\sim$ 55 km). A longer-term ozone depletion of $\sim$ 5% is indicated between 4 and 2 hPa ($\sim$ 40-45 km). The middle atmospheric changes caused by this solar event were very large and occurred fairly quickly ($\sim$ 1-2 days). Such a significant natural perturbation provides a good test of our understanding of the middle atmosphere. The measured and modelled impacts of this solar event will be compared and discussed in this paper.

Jackman, Charles H.↗

Mosaic-Detector-Based Fluorescence Spectral Imager

A battery-powered, pen-sized, portable instrument for measuring molecular fluorescence spectra of chemical and biological samples in the field has been proposed. Molecular fluorescence spectroscopy is among the techniques used most frequently in laboratories to analyze compositions of chemical and biological samples. Heretofore, it has been possible to measure fluorescence spectra of molecular species at relative concentrations as low as parts per billion (ppb), with a few nm spectral resolution. The proposed instrument would include a planar array (mosaic) of detectors, onto which a fluorescence spectrum would be spatially mapped. Unlike in the larger laboratory-type molecular fluorescence spectrometers, mapping of wavelengths to spatial positions would be accomplished without use of relatively bulky optical parts. The proposed instrument is expected to be sensitive enough to enable measurement of spectra of chemical species at relative concentrations <1 ppb, with spectral resolution that could be tailored by design to be comparable to a laboratory molecular fluorescence spectrometer. The proposed instrument (see figure) would include a button-cell battery and a laser diode, which would generate the monochromatic ultraviolet light needed to excite fluorescence in a sample. The sample would be held in a cell bounded by far-ultraviolet-transparent quartz or optical glass. The detector array would be, more specifically, a complementary metal oxide/ semiconductor or charge-coupled- device imaging photodetector array, the photodetectors of which would be tailored to respond to light in the wavelength range of the fluorescence spectrum to be measured. The light-input face of the photodetector array would be covered with a matching checkerboard array of multilayer thin film interference filters, such that each pixel in the array would be sensitive only to light in a spectral band narrow enough so as not to overlap significantly with the band of an adjacent pixel. The wavelength interval between adjacent pixels (and, thus, the spectral resolution) would typically be chosen by design to be approximately equal to the width of the total fluorescence wavelength range of interest divided by the number of pixels. The unitary structure comprising the photodetector array overlaid with the matching filter array would be denoted a hyperspectral mosaic detector (HMD) array.

Son, Kyung-Ah↗

Searching for the Beginning of the Ozone Turnaround Using a 22-Year Merged Satellite Data Set

We have used the data from six satellite instruments that measure the total column amount of ozone to construct a consistent merged data set extending from late 1978 into 2000. The keys to constructing a merged data set are to minimize potential drift of individual instruments and to accurately establish instrument-to-instrument offsets. We have used the short-wavelength D-pair measurements (306nm-313nm) of the SBUV and SBUV/2 instruments near the equator to establish a relatively drift-free record for these instruments. We have then used their overlap with the Nimbus 7 and EP TOMS instruments to establish the relative calibration of the various instruments. We have evaluated the drift uncertainty in our merged ozone data (MOD) set by examining both the individual instrument drift uncertainty and the uncertainty in establishing the instrument- to-instrument differences. We conclude that the instrumental drift uncertainty over the 22-year data record is 0.9 %/decade (2-sigma). We have compared our MOD record with 37 ground stations that have a continuous record over that time period. We have a mean drift with respect to the stations of +0.3 %/decade which is within 1-sigma of our uncertainty estimate. Using the satellite record as a transfer standard, we can estimate the capability of the ground instruments to establish satellite calibration. Adding the statistical variability of the station drifts with respect to the satellite to an estimate of the overall drift uncertainty of the world standard instrument, we conclude that the stations should be able to be used to establish the drift of the satellite data record to within and uncertainty of 0.6 %/decade (2-sigma). Adding to this an uncertainty due to the-incomplete global coverage of the stations, we conclude that the station data should be able to establish the global trend with an uncertainty of about 0.7 %/decade, slightly better than for the satellite record. We conclude that merging the two records together gives only a slight improvement in the uncertainty. Keeping them separate gives the greater confidence of two independent measures of the ozone trend and potential recovery. We fit the trend in our MOD record through May of 1991 and then extrapolated forward to see if the data at the end of the record was above the statistical model as a measure of ozone recovery as was done in the last WMO/UNEP assessment report. Because our data set drifts with respect to the ground-stations through May of 1991, we calculated a smaller global trend (-1.1 %/decade) than in the WMO/UNEP report. Our data in 1998 and 1999 was, on average 2 DU above the extrapolated statistical model with a 2-sigma uncertainty of 6 DU. For the combined mid-latitudes of the northern and southern hemispheres, the data was 5 DU above the extrapolated statistical model with a 2-sigma uncertainty of 10 DU. These may be signs of recovery, but they are still statistically insignificant.

Stolarski, Richard S.↗

Mobilization Protocols for Hybrid Sensors for Environmental AOP Sampling (HySEAS) Observations

The protocols presented here enable the proper mobilization of the latest-generation instruments for measuring the apparent optical properties (AOPs) of aquatic ecosystems. The protocols are designed for the Hybrid Sensors for Environmental AOP Sampling (HySEAS) class of instruments, but are applicable to the community of practice for AOP measurements. The protocols are organized into eleven sections beyond an introductory overview: a) cables and connectors, b) HySEAS instruments, c) platform preparation, d) instrument installation, e) cable installation, f) test deployment, g) test recovery, h) maintenance, i) shipping, j) storage, and k) smallboat operations. Each section concentrates on documenting how to prevent the most likely faults, remedy them should they occur, and accomplishing both with the proper application of a modest set of useful tools. Within the twelve sections, there are Socratic exercises to stimulate thought, and the answers to these exercises appear in Appendix A. Frequently asked questions (FAQs) are summarized in a separate section after the answers to the exercises in Appendix B. For practitioners unfamiliar with the nautical terms used throughout this document plus others likely encountered at sea, an abbreviated dictionary of nautical terms appears in Appendix C. An abbreviated dictionary of radiotelephone terms is presented in Appendix D. To ensure familiarity with many of the tools that are presented, Appendix E provides a description of the tools alongside a thumbnail picture. Abbreviated deployment checklists and cable diagrams are provided in Appendix F. The document concludes with an acknowledgments section, a glossary of acronyms, a definition of symbols, and a list of references.

Mobilizarion↗