Search NASA⌕ Search

SEARCH · Search NASA

Results for “Method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

The Effective Fragment Molecular Orbital Method: Achieving High Scalability and Accuracy for Large Systems

The effective fragment molecular orbital (EFMO) method has been developed to predict the total energy of a very large molecular system accurately (with respect to the underlying quantum mechanical method) and efficiently by taking advantage of the locality of strong chemical interactions and employing a two-level hierarchical parallelism. The accuracy of the EFMO method is partly attributed to the accurate and robust intermolecular interaction prediction between distant fragments, in particular, the many-body polarization and dispersion effects, which require the generation of static and dynamic polarizability tensors by solving the coupled perturbed Hartree–Fock (CPHF) and time-dependent HF (TDHF) equations, respectively. Solving the CPHF and TDHF equations is the main EFMO computational bottleneck due to the inefficient (serial) and I/O-intensive implementation of the CPHF and TDHF solvers. In this work, the efficiency and scalability of the EFMO method are significantly improved with a new CPU memory-based implementation for solving the CPHF and TDHF equations that are parallelized by either message passing interface (MPI) or hybrid MPI/OpenMP. Here, the accuracy of the EFMO method is demonstrated for both covalently bonded systems and noncovalently bound molecular clusters by systematically examining the effects of basis sets and a key distance-related cutoff parameter, R cut . R cut determines whether a fragment pair (dimer) is treated by the chosen ab initio method or calculated using the effective fragment potential (EFP) method (separated dimers). Decreasing the value of Rcut increases the number of separated (EFP) dimers, thereby decreasing the computational effort. It is demonstrated that excellent accuracy (<1 kcal/mol error per fragment) can be achieved when using a sufficiently large basis set with diffuse functions coupled with a small R cut value. With the new parallel implementation, the total EFMO wall time is substantially reduced, especially with a high number of MPI ranks. Given a sufficient workload, nearly ideal strong scaling is achieved for the CPHF and TDHF parts of the calculation. For the first time, EFMO calculations with the inclusion of long-range polarization and dispersion interactions on a hydrated mesoporous silica nanoparticle with explicit water solvent molecules (more than 15k atoms) are achieved on a massively parallel supercomputer using nearly 1000 physical nodes. In addition, EFMO calculations on the carbinolamine formation step of an amine-catalyzed aldol reaction at the nanoscale with explicit solvent effects are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Effect of Synthetic Method and Annealing Temperature on Metal Site Preference in Al 1-x Ga x FeO 3

Magnetoelectric materials couple both magnetic and electronic properties, making them attractive for use in multifunctional devices. The magnetoelectric AFeO 3 compounds (Pna2 1 ; A = Al, Ga) have received attention as the properties of the system depend on composition as well as the synthetic method used. Al 1–x Ga x FeO 3 (0 ≤ x ≤ 1) was synthesized by the sol–gel and coprecipitation methods and studied by X-ray absorption near-edge spectroscopy (XANES). Al L 2,3⁻ , Ga K-, and Fe K-edge XANES spectra were collected to examine how the average metal coordination number (CN) changes with the synthetic method. Al and Fe were found to prefer octahedral sites, while Ga prefers the tetrahedral site. It was found that composition played a larger role in determining site occupancies than synthetic method. Samples made by the sol–gel or ceramic methods (reported previously; Walker, J. D. S.; Grosvenor, A. P. J. Solid State Chem. 2013, 197, 147–153) showed smaller spectral changes than samples made via the coprecipitation method. This is attributed to greater ion mobility in samples synthesized via coprecipitation as the reactants do not have a long-range polymeric or oxide network during synthesis like samples synthesized via the sol–gel or ceramic method. Increasing annealing temperature increases the average coordination number of Al, and to a lesser extent Ga, while the average coordination number of Fe decreases. This study indicates that greater disorder is observed when the Al 1–x Ga x FeO 3 compounds have high Al content, and when annealed at higher temperatures.

Walker, James D.S.↗

Effectiveness of CID, HCD, and ETD with FT MS/MS for Degradomic-Peptidomic Analysis: Comparison of Peptide Identification Methods

We report on use of an Orbitrap Velos mass spectrometer for comparison of fragmentation methods namely CID-, HCD-, and ETD for FT MS/MS analysis of human blood plasma peptidomic peptides. The peptidomic peptides were able to be identified from CID, HCD, and ETD spectra on specific confidence levels (e.g., 1% false discovery rate) with use of conventional SEQUEST database search software, and the number of identified peptides was increased by ~50% using accurate fragments (e.g., with mass tolerance of 0.05Da) in comparison with traditional moderate accuracy fragments (e.g., with 1 Da mass tolerance) for database search. However, the peptide datasets identified with such decoy search strategy were found to be varied by ~25% in the dataset size and ~20% in the dataset content with type of decoy database and precursor mass tolerances used for database search. CID was evaluated as the largest contributor to the identified peptide datasets, and HCD, and ETD provided ~20% and ~22% respectively additional peptides with accurate fragments for peptide identification, in contrast to ~25% and ~13% respectively with use of moderate accuracy fragments. When long (typically ≥7 amino acids) sequences were used for identification of peptides from the previously published UStags and de novo sequencing methods, HCD was evaluated as the largest contributor, and CID and ETD provided ~26% and ~8% respectively additional peptides from the UStags method and ~26% and ~6% respectively additional peptides from the de novo sequencing method. The peptide datasets identified with the UStags method were little influenced by the decoy database and mass tolerance and 98-99% peptide overlaps could be achieved between these datasets. CID, HCD, and ETD contributed their identifications of various charge state peptides in the m/z range highly overlapped and complementary implementation of CID, HCD, and ETD should be applied to maximize the number of peptides identified. Finally, the investigation presented in this work suggests that selection of fragmentation methods benefits significantly from a careful match with data analysis method applied for identification of peptides and the analysis throughput desired for various purposes of peptidomic-degradomic analysis.

59 BASIC BIOLOGICAL SCIENCES↗

Physics-Informed Neural Network Method for Forward and Backward Advection-Dispersion Equations

Advection-dispersion equations (ADEs) are commonly used to describe transport phenomena in porous media. Even though mature discretization-based numerical methods for ADEs exist, some challenges still remain, especially when it comes to solving advection-dominated forward ADEs and diffusion-dominated backward ADEs. The latter problem usually arises in the source identification context and leads to numerically unstable grid-based solutions that require a form of regularization or should be treated as an inverse problem that is computationally more expensive because it requires solving the forward problem multiple times. In this study, we propose a discretization-free approach based on the physics-informed neural network (PINN) method for solving coupled ADE and Darcy flow equations with space-dependent hydraulic conductivity. In this approach, the hydraulic conductivity, hydraulic head, and concentration fields are approximated with deep neural networks (DNNs). We assume that the conductivity field is given by its values on a grid, and we use these values to train the conductivity DNN. The head and concentration DNNs are trained by minimizing the residuals of the flow equation and ADE and using the initial and boundary conditions as additional constraints. The PINN method is applied to one- and two-dimensional forward ADE problems, where its performance for various P\'{e}clet numbers ($Pe$) is compared with the analytical and numerical solutions. We find that the PINN method is accurate with errors of less than 1\% and outperforms some conventional discretization-based methods for $Pe$ larger that 100. Next, we demonstrate that the PINN method remains accurate for the backward ADEs, with the relative errors in most cases staying under 5\% compared to the reference concentration field. Finally, we show that when available, the concentration measurements can be easily incorporated in the PINN method and significantly improve (by more than 50\% in the considered cases) the accuracy of the PINN solution of the backward ADE.

He, Qizhi↗

Spanning the Gap From Bulk to Bin: A Novel Spectral Microphysics Method

Microphysics methods for climate models and numerical weather prediction typically track one, two, or three moments of a droplet size distribution for various categories of liquid, ice, and aerosol. Such methods rely on conversion parameters between these categories, which introduces uncertainty into predictions. While higher-fidelity options such as bin and Lagrangian schemes exist, they require too many degrees of freedom for climate modeling applications and introduce numerical challenges. Here we introduce a flexible spectral microphysics method based on collocation of basis functions. This method generalizes to a linear bulk scheme when using few basis functions and to a smoothed bin scheme with more degrees of freedom. Tested in an idealized box setting, the method improves spectral accuracy for droplet collision-coalescence and may eliminate the need for precipitation autoconversion rates required by bulk methods; furthermore, it generalizes well to multimodal distributions with less complexity than a bin method. The potential to extend this collocation representation to multiple hydrometeor classes suggests a path forward to unify liquid, ice, and aerosol microphysics in a single, flexible, computational framework for climate modeling.

54 ENVIRONMENTAL SCIENCES↗

Assessment of Extinction‐, Satellite‐, and Model‐Based Vertical Cloud Condensation Nuclei (CCN) Retrieval Methods Using Airborne CCN Measurements Over the Southern Great Plains

Abstract Accurate estimates of the vertical profile of cloud condensation nuclei (CCN) concentration are crucial to better quantify aerosol‐cloud interactions. We assessed the correlation between the vertical CCN concentrations obtained from extinction‐, satellite‐, and model‐based retrieval methods and airborne CCN concentrations collected at 0.24% supersaturation within the 3, 9, 27, and 81 km regions centered over the U.S. Department of Energy's Atmospheric Radiation Measurement User Facility Southern Great Plains (SGP) site during the spring and summer of 2016. The extinction profiles at a wavelength 355 nm were provided by the ground‐based Raman lidar. Our analysis showed moderate correlation between dry‐corrected extinction and airborne CCN data. We found the retrieved number concentration of CCN (RNCCN) method showed regression best‐fit slopes close to unity and consistent prediction errors for the majority of the data. The Lenhardt et al. (2023, https://doi.org/10.5194/amt‐16‐2037‐2023 ) method showed similar conclusions but only during spring, whereas the Mamouri and Ansmann (2016, https://doi.org/10.5194/acp‐16‐5905‐2016 ) method showed poor correlation. The Shinozuka et al. (2015, https://doi.org/10.5194/acp‐15‐7585‐2015 ) satellite‐based method exhibited reasonable agreement during summer but poor correlation during periods where both high (∼1,400 #/cm 3 ) and low (∼50 #/cm 3 ) airborne CCN concentrations were observed. The Copernicus Atmosphere Monitoring Service reanalysis modeled 3‐D CCN data set showed a moderate to weak positive correlation but performed poorly at high airborne CCN concentrations. Our analysis suggests the extinction‐based RNCCN method performed better than other methods across most observation periods under the diverse meteorological conditions observed at the SGP site.

54 ENVIRONMENTAL SCIENCES↗

Online energy consumption forecast for battery electric buses using a learning-free algebraic method

Accurately predicting the energy consumption plays a vital role in battery electric buses (BEBs) route planning and deployment. Based on the algebraic derivative estimation, we present a novel method to forecast the energy consumption in real time. In contrast to the mainstream machine-learning-based methods, the proposed method does not require access to the historical energy consumption data. It eliminates the time-consuming and computationally expensive offline training. Consequently, its prediction performance is not constrained by the quantity and quality of the training data. Moreover, the method can swiftly adapt to new situations not included in the previous driving cycles, which makes it especially suitable for emerging transport modes, e.g., on-demand transit services. In addition, its online execution only involves algebraic calculations, yielding superior calculation efficiency. Using real-world data, we comprehensively compare the performance of the proposed learning-free algebraic method with multiple representative machine-learning-based methods. Finally, the advantages and limitations of the proposed method are discussed in detail.

33 ADVANCED PROPULSION SYSTEMS↗

A universal method for sensitive and cell-free detection of CRISPR-associated nucleases

A multitude of biological applications for CRISPR-associated (Cas) nucleases have propelled the development of robust cell-based methods for quantitation of on- and off-target activities of these nucleases. However, emerging applications of these nucleases require cell-free methods that are simple, sensitive, cost effective, high throughput, multiplexable, and generalizable to all classes of Cas nucleases. Current methods for cell-free detection are cumbersome, expensive, or require sophisticated sequencing technologies, hindering their widespread application beyond the field of life sciences. Developing such cell-free assays is challenging for multiple reasons, including that Cas nucleases are single-turnover enzymes that must be present in large excess over their substrate and that different classes of Cas nucleases exhibit wildly different operating mechanisms. Here, we report the development of a cell-free method wherein Cas nuclease activity is amplified via an in vitro transcription reaction that produces a fluorescent RNA:small-molecule adduct. We demonstrate that our method is sensitive, detecting activity from low nanomolar concentrations of several families of Cas nucleases, and can be conducted in a high-throughput microplate fashion with a simple fluorescent-based readout. We provide a mathematical framework for quantifying the activities of these nucleases and demonstrate two applications of our method, namely the development of a logic circuit and the characterization of an anti-CRISPR protein. We anticipate our method will be valuable to those studying Cas nucleases and will allow the application of Cas nuclease beyond the field of life sciences.

60 APPLIED LIFE SCIENCES↗

Testing contamination source identification methods for water distribution networks

In the event of contamination in a water distribution network (WDN), source identification (SI) methods that analyze sensor data can be used to identify the source location(s). Knowledge of the source location and characteristics are important to inform contamination control and cleanup operations. Various SI strategies that have been developed by researchers differ in their underlying assumptions and solution techniques. The following manuscript presents a systematic procedure for testing and evaluating SI methods. The performance of these SI methods is affected by various factors including the size of WDN model, measurement error, modeling error, time and number of contaminant injections, and time and number of measurements. This paper includes test cases that vary these factors and evaluates three SI methods on the basis of accuracy and specificity. The tests are used to review and compare these different SI methods, highlighting their strengths in handling various identification scenarios. These SI methods and a testing framework that includes the test cases and analysis tools presented in this paper have been integrated into EPA’s Water Security Toolkit (WST), a suite of software tools to help researchers and others in the water industry evaluate and plan various response strategies in case of a contamination incident. Lastly, a set of recommendations are made for users to consider when working with different categories of SI methods.

54 ENVIRONMENTAL SCIENCES↗

In situ method for real time measurement of dielectric film thickness in plasmas

An in situ thickness measurement method of dielectric films (dual frequency method) was developed, and the thicknesses were measured in an inductively coupled plasma. This method uses a small ac bias voltage with two frequencies for thickness measurement. The dielectric thickness is obtained from measuring the amplitudes of the two frequency ac currents through a sensor, as well as using an equivalent circuit model describing impedance of the dielectric film and the plasma sheath. In the experiment, the thicknesses of Al{sub 2}O{sub 3} film could be accurately measured in real time. To check the measurement reliability, the dual frequency method was compared with reflection spectrophotometry as a technique for optical thickness diagnostics. It was found that the dual frequency method agrees closely with reflection spectrophotometry at various rf powers and pressures. In addition, this method is very simple and can be installed anywhere in plasma reactors, in contrast with optical methods; therefore, it is expected to be applied to in situ surface diagnostics for various processing plasmas.

36 MATERIALS SCIENCE↗

TWO NOVEL ACM (ACTIVE CONTOUR MODEL) METHODS FOR INTRAVASCULAR ULTRASOUND IMAGE SEGMENTATION

One of the attractive image segmentation methods is the Active Contour Model (ACM) which has been widely used in medical imaging as it always produces sub-regions with continuous boundaries. Intravascular ultrasound (IVUS) is a catheter based medical imaging technique which is used for quantitative assessment of atherosclerotic disease. Two methods of ACM realizations are presented in this paper. The gradient descent flow based on minimizing energy functional can be used for segmentation of IVUS images. However this local operation alone may not be adequate to work with the complex IVUS images. The first method presented consists of basically combining the local geodesic active contours and global region-based active contours. The advantage of combining the local and global operations is to allow curves deforming under the energy to find only significant local minima and delineate object borders despite noise, poor edge information and heterogeneous intensity profiles. Results for this algorithm are compared to standard techniques to demonstrate the method's robustness and accuracy. In the second method, the energy function is appropriately modified and minimized using a Hopfield neural network. Proper modifications in the definition of the bias of the neurons have been introduced to incorporate image characteristics. The method overcomes distortions in the expected image pattern, such as due to the presence of calcium, and employs a specialized structure of the neural network and boundary correction schemes which are based on a priori knowledge about the vessel geometry. The presented method is very fast and has been evaluated using sequences of IVUS frames.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Standardization of Laser Methods and Techniques for Vibration Measurements and Calibrations

The realization and dissemination of the SI units of motion quantities (vibration and shock) have been based on laser interferometer methods specified in international documentary standards. New and refined laser methods and techniques developed by national metrology institutes and by leading manufacturers in the past two decades have been swiftly specified as standard methods for inclusion into in the series ISO 16063 of international documentary standards. A survey of ISO Standards for the calibration of vibration and shock transducers demonstrates the extended ranges and improved accuracy (measurement uncertainty) of laser methods and techniques for vibration and shock measurements and calibrations. The first standard for the calibration of laser vibrometers by laser interferometry or by a reference accelerometer calibrated by laser interferometry (ISO 16063-41) is on the stage of a Draft International Standard (DIS) and may be issued by the end of 2010. The standard methods with refined techniques proved to achieve wider measurement ranges and smaller measurement uncertainties than that specified in the ISO Standards. The applicability of different standardized interferometer methods to vibrations at high frequencies was recently demonstrated up to 347 kHz (acceleration amplitudes up to 350 km/s{sup 2}). The relative deviations between the amplitude measurement results of the different interferometer methods that were applied simultaneously, differed by less than 1% in all cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of electron density with the phase-resolved cut-off probe method

The phase resolved cut-off probe method, a precise measurement method for the electron density, was recently proposed [J. H. Kwon et al., Appl. Phys. Lett. 96, 081502 (2010)]. This paper presents the measurements of electron density using the method under various experimental conditions (different pressures, powers, chamber volumes, and discharge sources). The result shows that the method is not only in good agreement with the previous method using wave transmittance under various experimental conditions but it is also able to find the cut-off point clearly even under difficult conditions such as high pressure ({approx} 1 Torr), high discharge power, and small plasma volume. The details of the experimental setup, the operating mechanism of the probe method, and the data processing procedure (algorithm) are also addressed. Furthermore, the reliability of the measurement method is investigated by using an electromagnetic field simulation with cold plasma model (CST-Drude model, Computer Simulation Technology).

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A simple differential steady-state method to measure the thermal conductivity of solid bulk materials with high accuracy

Accurate measurements of thermal conductivity are of great importance for materials research and development. Steady-state methods determine thermal conductivity directly from the proportionality between heat flow and an applied temperature difference (Fourier Law). Although theoretically simple, in practice, achieving high accuracies with steady-state methods is challenging and requires rather complex experimental setups due to temperature sensor uncertainties and parasitic heat loss. We developed a simple differential steady-state method in which the sample is mounted between an electric heater and a temperature-controlled heat sink. Our method calibrates for parasitic heat losses from the electric heater during the measurement by maintaining a constant heater temperature close to the environmental temperature while varying the heat sink temperature. This enables a large signal-to-noise ratio which permits accurate measurements of samples with small thermal conductance values without an additional heater calibration measurement or sophisticated heater guards to eliminate parasitic heater losses. Additionally, the differential nature of the method largely eliminates the uncertainties of the temperature sensors, permitting measurements with small temperature differences, which is advantageous for samples with high thermal conductance values and/or with strongly temperature-dependent thermal conductivities. In order to accelerate measurements of more than one sample, the proposed method allows for measuring several samples consecutively at each temperature measurement point without adding significant error. We demonstrate the method by performing thermal conductivity measurements on commercial bulk thermoelectric Bi 2 Te 3 samples in the temperature range of 30–150 °C with an error below 3%.

47 OTHER INSTRUMENTATION↗

Perturbative approximation to hybrid equation of motion coupled cluster/effective fragment potential method

Hybrid quantum mechanics/molecular mechanics (QM/MM) methods provide an attractive way to closely retain the accuracy of the QM method with the favorable computational scaling of the MM method. Therefore, it is not surprising that QM/MM methods are being increasingly used for large chemical/biological systems. Hybrid equation of motion coupled cluster singles doubles/effective fragment potential (EOM-CCSD/EFP) methods have been developed over the last few years to understand the effect of solvents and other condensed phases on the electronic spectra of chromophores. However, the computational cost of this approach is still dominated by the steep scaling of the EOM-CCSD method. In this work, we propose and implement perturbative approximations to the EOM-CCSD method in this hybrid scheme to reduce the cost of EOM-CCSD/EFP. The timings and accuracy of this hybrid approach is tested for calculation of ionization energies, excitation energies, and electron affinities of microsolvated nucleic acid bases (thymine and cytosine), phenol, and phenolate.

74 ATOMIC AND MOLECULAR PHYSICS↗

Review methods for image segmentation from computed tomography images

Image segmentation is a challenging process in order to get the accuracy of segmentation, automation and robustness especially in medical images. There exist many segmentation methods that can be implemented to medical images but not all methods are suitable. For the medical purposes, the aims of image segmentation are to study the anatomical structure, identify the region of interest, measure tissue volume to measure growth of tumor and help in treatment planning prior to radiation therapy. In this paper, we present a review method for segmentation purposes using Computed Tomography (CT) images. CT images has their own characteristics that affect the ability to visualize anatomic structures and pathologic features such as blurring of the image and visual noise. The details about the methods, the goodness and the problem incurred in the methods will be defined and explained. It is necessary to know the suitable segmentation method in order to get accurate segmentation. This paper can be a guide to researcher to choose the suitable segmentation method especially in segmenting the images from CT scan.

60 APPLIED LIFE SCIENCES↗

A fast and reliable readout method for quantitative analysis of surface-enhanced Raman scattering nanoprobes on chip surface

Surface-enhanced Raman scattering techniques have been widely used for bioanalysis due to its high sensitivity and multiplex capacity. However, the point-scanning method using a micro-Raman system, which is the most common method in the literature, has a disadvantage of extremely long measurement time for on-chip immunoassay adopting a large chip area of approximately 1-mm scale and confocal beam point of ca. 1-μm size. Alternative methods such as sampled spot scan with high confocality and large-area scan method with enlarged field of view and low confocality have been utilized in order to minimize the measurement time practically. In this study, we analyzed the two methods in respect of signal-to-noise ratio and sampling-led signal fluctuations to obtain insights into a fast and reliable readout strategy. On this basis, we proposed a methodology for fast and reliable quantitative measurement of the whole chip area. The proposed method adopted a raster scan covering a full area of 100 μm × 100 μm region as a proof-of-concept experiment while accumulating signals in the CCD detector for single spectrum per frame. One single scan with 10 s over 100 μm × 100 μm area yielded much higher sensitivity compared to sampled spot scanning measurements and no signal fluctuations attributed to sampled spot scan. This readout method is able to serve as one of key technologies that will bring quantitative multiplexed detection and analysis into practice.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Daniell method for power spectral density estimation in atomic force microscopy

An alternative method for power spectral density (PSD) estimation—the Daniell method—is revisited and compared to the most prevalent method used in the field of atomic force microscopy for quantifying cantilever thermal motion—the Bartlett method. Both methods are shown to underestimate the Q factor of a simple harmonic oscillator (SHO) by a predictable, and therefore correctable, amount in the absence of spurious deterministic noise sources. However, the Bartlett method is much more prone to spectral leakage which can obscure the thermal spectrum in the presence of deterministic noise. By the significant reduction in spectral leakage, the Daniell method leads to a more accurate representation of the true PSD and enables clear identification and rejection of deterministic noise peaks. This benefit is especially valuable for the development of automated PSD fitting algorithms for robust and accurate estimation of SHO parameters from a thermal spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗