Search NASA⌕ Search

SEARCH · Search NASA

Results for “MicroED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Accounting for electron-beam-induced warping of molecular nanocrystals in MicroED structure determination

High-energy electrons induce sample damage and motion at the nanoscale to fundamentally limit the determination of molecular structures by electron diffraction. Using a fast event-based electron counting (EBEC) detector, we characterize beam-induced, dynamic, molecular crystal lattice reorientations (BIRs). These changes are sufficiently large to bring reciprocal lattice points entirely in or out of intersection with the sphere of reflection, occur as early events in the decay of diffracted signal due to radiolytic damage, and coincide with beam-induced migrations of crystal bend contours within the same fluence regime and at the same illuminated location on a crystal. These effects are observed in crystals of biotin, a series of amino acid metal chelates, and a six-residue peptide, suggesting that incident electrons inevitably warp molecular lattices. The precise orientation changes experienced by a given microcrystal are unpredictable but are measurable by indexing individual diffraction patterns during beam-induced decay. Reorientations can often tilt a crystal lattice several degrees away from its initial position before irradiation, and for an especially beam-sensitive Zn(II)-methionine chelate, are associated with dramatic crystal quakes prior to 1 e − Å −2 electron beam fluence accumulates. Since BIR coincides with the early stages of beam-induced damage, it echoes the beam-induced motion observed in single-particle cryoEM. As with motion correction for cryoEM imaging experiments, accounting for BIR-induced errors during data processing could improve the accuracy of MicroED data.

Vlahakis, Niko (ORCID:0000000250920265)↗

Operation and performance of the ATLAS silicon micro-strip tracker

The Semiconductor Tracker (SCT) is the key precision tracking device in ATLAS, made from silicon micro-strip detectors processed in the planar p-in-n technology. The completed SCT has been installed inside the ATLAS experimental hall since 2007 and has been operational since then. In this paper the current status of the Semiconductor Tracker is reviewed, including results from the data-taking periods in 2009 and 2010, and from the detector alignment. The emphasis is given to the performance of the Semiconductor Tracker with the LHC in collision mode and to the performance of individual electronic components. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improving Energy Use Forecast for Campus Micro-grids using Indirect Indicators

The rising global demand for energy is best addressed by adopting and promoting sustainable methods of power consumption. We employ an informatics approach towards forecasting the energy consumption patterns in a university campus micro-grid which can be used for energy use planning and conservation. We use novel indirect indicators of energy that are commonly available to train regression tree models that can predict campus and building energy use for coarse (daily) and fine (15-min) time intervals, utilizing 3 years of sensor data collected at 15min intervals from 170 smart power meters. We analyze the impact of individual features used in the models to identify the ones best suited for the application. Our models show a high degree of accuracy with CV-RMSE errors ranging from 7.45% to 19.32%, and a reduction in error from baseline models by up to 53%.

energy forecast models↗

Vehicle-to-Grid Automatic Load Sharing with Driver Preference in Micro-Grids

Integration of Electrical Vehicles (EVs) with power grid not only brings new challenges for load management, but also opportunities for distributed storage and generation. This paper comprehensively models and analyzes distributed Vehicle-to-Grid (V2G) for automatic load sharing with driver preference. In a micro-grid with limited communications, V2G EVs need to decide load sharing based on their own power and voltage profile. A droop based controller taking into account driver preference is proposed in this paper to address the distributed control of EVs. Simulations are designed for three fundamental V2G automatic load sharing scenarios that include all system dynamics of such applications. Simulation results demonstrate that active power sharing is achieved proportionally among V2G EVs with consideration of driver preference. In additional, the results also verify the system stability and reactive power sharing analysis in system modelling, which sheds light on large scale V2G automatic load sharing in more complicated cases.

Wang, Yubo↗

Frequency Event Categorization in Power Distribution Systems Using Micro PMU Measurements

Frequency is an important metric for power stability. To enhance the situational awareness in power distribution systems, this article proposes a data-driven approach that utilizes the data from micro phasor measurement units (μPMU) to categorize frequency events observed in distribution feeders. The proposed approach has three layers, each of which analyzes if a frequency event is propagated from the transmission system, formed inside a distribution feeder or falsely produced by instantaneous frequency (IF) estimation algorithms, respectively. In the first layer, the Granger causality is utilized to compare the causal relations from measurements across different locations to decide if an event is propagated from the transmission side. In the second layer, a trained sparse coding dictionary is utilized to unmix the physical causes of a frequency event. In the third layer, a moving z-score based event-pair detector is applied to identify if a frequency event is algorithm-induced. The proposed approach is tested using the μPMU measurements collected from Lawrence Berkeley National Laboratory (LBNL) and Riverside Public Utility (RPU).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Designing Piezoelectric Films for Micro Electromechanical Systems

Piezoelectric thin films are of increasing interest in low-voltage micro electromechanical systems for sensing, actuation, and energy harvesting. They also serve as model systems to study fundamental behavior in piezoelectrics. Next-generation technologies such as ultrasound pill cameras, flexible ultrasound arrays, and energy harvesting systems for unattended wireless sensors will all benefit from improvements in the piezoelectric properties of the films. This paper describes tailoring the composition, microstructure, orientation of thin films, and substrate choice to optimize the response. It is shown that increases in the grain size of lead-based perovskite films from 75 to 300 nm results in 40 and 20% increases in the permittivity and piezoelectric coefficients, respectively. This is accompanied by an increase in the nonlinearity in the response. Band excitation piezoresponse force microscopy was used to interrogate the nonlinearity locally. It was found that chemical solution-derived PbZr(0.52)Ti(0.48)O(3) thin films show clusters of larger nonlinear response embedded in a more weakly nonlinear matrix. The scale of the clusters significantly exceeds that of the grain size, suggesting that collective motion of many domain walls contributes to the observed Rayleigh behavior in these films. Finally, it is shown that it is possible to increase the energy-harvesting figure of merit through appropriate materials choice, strong imprint, and composite connectivity patterns.

Trolier-McKinstry, Susan↗

Effect of skin flexibility on aerodynamic performance of flexible skin flapping wings for micro air vehicles

As part of the ongoing research on micro air vehicles, the present work focuses on the effect of membrane flexibility on the aerodynamic performance of flexible latex flapping wings. Wings with membrane thicknesses 0.37, 0.28, and 0.13 mm are chosen, which are named as least flexible (A), flexible (B), and most flexible (C), respectively. The experiments are performed in an air chamber of size 1.5 m × 1.5 m × 1.5 m, facilitated with wind velocities up to 15 m/s. The time-averaged lift and drag as functions of flapping frequency, forward flight velocity, the angles of attack (AoA), and advance ratio (J). The novel electronic control system developed previously is used to monitor and measure the flapping frequency. It is found that the effect of flexibility on the aerodynamic performance mainly depends on the range of flight speed; at 7200 ≤ Re ≤ 18,000, the lift and drag increase with increase of flexibility, and at 18,000 ≤ Re ≤ 25,200, the lift decreases and drag increases with increase of flexibility. Hence latex compliant (Wing C) wings are advantageous in the low Re range, while the least flexible wing (Wing A) is preferable for higher range.

42 ENGINEERING↗

A high-speed micro-impact testing system for evaluating the properties of lead-free solder joints

ConclusionThis study presents a novel high-speed micro-impact testing system for evaluating the shear strength and energy absorbance properties of lead-free solder ball joints under impact velocities of 0.3–1.0 m/s. The test method can examine the failure mode transition from ductile failure to brittle failure based on the failure mode distribution percentage. The load—displacement curves can distinguish between different failure modes. Notably, the values of peak load and the energy-to-peak load at various impact speeds can be used as indices for determining solder ball under impact loading conditions. Thus, the proposed method is a suitable technique for evaluating the mechanical response of solder ball joints used in typical semiconductor packages and, therefore, represents a simple and effective technique for optimizing the chip-level reliability of portable consumer electronic products.

36 MATERIALS SCIENCE↗

Development of flexible wings and flapping mechanism with integrated electronic control system, for micro air vehicle research

This paper presents the development of flexible wings, flapping mechanism, and integrated electronic control system (ECS) to emulate the bat wing flapping for the ongoing micro air vehicle (MAV) research. Three bat species having dimensions close to the design requirement of MAV, namely, Mormopterus Planiceps, Nytophilus Geoffroyi, and Scotorepens Balstoni were selected, and the average of their physical dimensions was chosen. The commercially available titanium alloy, Ti ± 6Al ± 4V, was used for the wing frame, and the membrane was made of latex. A four-bar slider-crank mechanism was designed and fabricated to facilitate the wing flapping; ECS controlled the flapping frequency in the real-time mode. The system was tested in open air wind tunnel at frequency6 Hz, angle of attack (AOA) 0–50°, and velocity range 2–7 m s{sup −1}. The experimental flapping angle which is compared with the theoretical flapping angle was obtained from the analytical kinematic model. The mean lift and drag coefficients were also measured and the results were found to be excellent. Compared to the manual control and measurement of flapping frequency, the proposed ECS demonstrates efficient control and accurate measurement. Moreover, the tedious procedure involved in the repeated calibrations for the manual system is totally eliminated by ECS.

42 ENGINEERING↗

PhaseChange Material Melting in an Energy Storage Module for a Micro Environmental ControlSystem

An experimentally validated finite element model (FEM) was developed to analyze the design parameters of a latent heat storage device (LHSD) for a micro environmental control system ( μ X). The μ X provides local cooling to an office worker in a room whose thermostat setpoint has been elevated from 23.9 °C (75 °F) to 26.1 °C (79 °F) in order to reduce heating, ventilation, and air conditioning (HVAC) energy consumption. For this application, the LHSD is designed to provide ≥50 W of cooling for a full, 8.5 h workday to restore thermal comfort in the warm, 26.1 °C room. The LHSD comprises several parallel slabs of encased phase change material (PCM) with interposed airflow channels. The airflow rate is selected to obtain ≥50 W of cooling at the end of the 8.5 h operation. The LHSD exhibits a decreasing cooling rate over the 8.5 h period when a constant airflow is passed through it, indicating that more cooling is supplied during the day than the minimum 50 W required for thermal comfort. The parametric analysis explores the effects of PCM thermal conductivity, slab thickness, air channel width, and number of slabs on LHSD performance. Parametric cases are compared against each other on the basis of their required PCM mass and energy consumption.

Engineering↗

Micro-Tubular Solid Oxide Fuel Cell Polarization and Impedance Variation With Thin Porous Samarium-Doped Ceria and Gadolinium-Doped Ceria Buffer Layer Thickness

Abstract Porous buffer layers for anode-supported solid oxide fuel cells (SOFCs) have been investigated for many years with different thicknesses of the buffer layer in each study. In this work, micro-tubular SOFCs having samarium-doped ceria (SDC) and gadolinium-doped ceria (GDC) buffer layers are compared using the current–voltage technique, electrochemical impedance spectroscopy, scanning electron microscopy, and energy-dispersive X-ray spectroscopy. The thickness of the porous SDC and GDC buffer layer is investigated systematically with the thickness varying between 0.3 and 2.0 μm. The power density varies between 212 and 1004 mW/cm2 for samples having different SDC buffer layer thickness. Comparable changes occur for the SOFCs with a GDC buffer layer, but less variation in polarization losses resulted. Variation in electrochemical performance varies due to changes in ohmic resistance, cathode activation polarization, and interfacial reactions between the cathode and electrolyte materials.

Electrochemistry↗

Investigation of Rapid, Moderate Temperature Change Thermal Cycles of a Micro-Tubular Flame-Assisted Fuel Cell

Despite many efforts and improvements over the last few decades, two of the major challenges facing solid oxide fuel cells (SOFCs) are slow heating rates to operating temperature (typically < 5 °C · min–1) and a limited ability to thermal cycle (<200 cycles). Recently, a novel hybrid setup that combines a fuel-rich combustion reformer with a SOFC was developed and utilized to investigate rapid heating, cooling, and thermal cycling of a micro-tubular SOFC. In this work, 3000 moderate thermal cycles are conducted at a heating rate exceeding 140 °C · min–1 and a cooling rate that exceeded 100 °C · min–1. The open-circuit voltage (OCV) was analyzed over the 150 h test, and a low degradation rate of ~0.0008 V per 100 cycles per fuel cell was observed in the absence of the current collector degradation. Unlike a previous test, which was conducted at lower temperatures, significant degradation of the current collector was observed during this test. Electrochemical impedance spectroscopy shows that degradation in the SOFC was due to increases in ohmic losses, activation losses at the cathode, and increased concentration losses.

Electrochemistry↗

Surface Heater Fabrication Using Micro-Lithography for Transpiration Cooling Heat Transfer Coefficient Measurements

Abstract Transpiration cooling is able to provide more uniform coolant coverage than film cooling to effectively protect the component surface from contacting the hot gas. Due to numerous coolant ejection outlets within a small area at the target surface, the experimental thermo-fluid investigation on transpiration cooling becomes a significant challenge. Two classic methods to investigate film cooling, the steady-state foil heater method and the transient thermography technique, fail for transpiration cooling because the foil heater would block numerous coolant outlets, and the semi-infinite solid conduction model no longer holds for porous plates. In this study, a micro-lithography method to fabricate a silver coil pattern on top of the additively manufactured polymer porous media as the surface heater was proposed. The circuit was deliberately designed to cover the solid surface in a combination of series connection, and parallel connection to ensure the power in each unit cell area at the target surface was identical. With uniform heat flux generation, the steady-state tests were conducted to obtain distributions of a pair of parameters, adiabatic cooling effectiveness, and heat transfer coefficient (HTC). The results showed that the adiabatic cooling effectiveness could reach 0.65 with a blowing ratio lower than 0.5. Meanwhile, the heat transfer coefficient ratio (hf/h0) of transpiration cooling was close to 1 with a small blowing ratio at 0.125. A higher HTC ratio was observed for smaller pitch-to-diameter cases due to more turbulence intensity generated at the target surface.

Engineering↗

A Micro-Mechanical Constitutive Model to Predict Hygrothermal Aging of Cross-Linked Polymers

Abstract A multi-physics material model is presented to describe the effects of temperature, oxygen, and humidity on the constitutive response of cross-linked polymers. The effect of hygrothermal damage on the mechanical integrity of the polymer matrix can be considered as the result of damage accumulation of two independent aging mechanism namely, i) thermo-oxidative, and ii) hydrolytic aging. In order to capture the mutual effects of thermo-oxidative and hydrolytic aging, an assumption has been made that each of the aging phenomenon can be superposed to each other. In fact, each of them works independently and as a result, they can compete with each other. Utilizing the theory of network decomposition, all phenomena and their correlation were modeled and thus, the strain energy function of the polymer matrix is written with respect to four independent mechanisms, i) the shrinking original matrix that has neither been attacked by water nor oxygen, ii) conversion of the first network to two new network due to the reduction and formation of cross-links, and iii) energy loss from network degradation due to attack of the water molecules to polymer active agents. Moreover, the proposed model is micro-mechanically based and is mainly relevant on thin samples due to our underlying assumption of homogeneous diffusion of oxygen and water throughout the matrix. The model has been validated against extensive data-sets obtained from experiments we specifically designed for concept validation.

Bahrololoumi, Amir↗

Study of a micro chamber quadrupole mass spectrometer

The design of a micro chamber quadrupole mass spectrometer (MCQMS) having a small total volume of only 20 cm{sup 3}, including Faraday cup ion detector and ion source, is described. This MCQMS can resist a vacuum baking temperature of 400-500 deg. C. The quadrupole elements with a hyperbolic surface are made of a ceramic material and coated with a thin metal layer. The quadrupole mass filter has a field radius of 3 mm and a length of 100 mm. Prototypes of this new MCQMS can detect a minimum partial pressure of 10{sup -8} Pa, have a peak width of {delta}M=1 at 10% peak height from mass number 1 to 60, and show an excellent long-term stability. The new MCQMS is intended to be used in residual gas analyses of electron devices during a mutual pumping and baking process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Long-life micro vacuum chamber for a micromachined cryogenic cooler

Micromachined cryogenic coolers can be used for cooling small electronic devices to improve their performance. However, for reaching cryogenic temperatures, they require a very good thermal insulation from the warm environment. This is established by a vacuum space that for adequate insulation has to be maintained at a pressure of 0.01 Pa or lower. In this paper, the challenge of maintaining a vacuum chamber with a volume of 3.6 × 10{sup −5} m{sup 3} and an inner wall area of 8.1 × 10{sup −3} m{sup 2} at a pressure no higher than 0.01 Pa for five years is theoretically analyzed. The possible sources of gas, the mechanisms by which these gases enter the vacuum space and their effects on the pressure in the vacuum chamber are discussed. In a long-duration experiment with four stainless steel chambers of the above dimensions and equipped with a chemical getter, the vacuum pressures were monitored for a period of two years. In that period, the measured pressure increase stayed within 0.01 Pa. This study can be used to guide the design of long-lifetime micro vacuum chambers that operate without continuous mechanical pumping.

42 ENGINEERING↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Self-calibration of a cone-beam micro-CT system

Use of cone-beam computed tomography (CBCT) is becoming more frequent. For proper reconstruction, the geometry of the CBCT systems must be known. While the system can be designed to reduce errors in the geometry, calibration measurements must still be performed and corrections applied. Investigators have proposed techniques using calibration objects for system calibration. In this study, the authors present methods to calibrate a rotary-stage CB micro-CT (CB{mu}CT) system using only the images acquired of the object to be reconstructed, i.e., without the use of calibration objects. Projection images are acquired using a CB{mu}CT system constructed in the authors' laboratories. Dark- and flat-field corrections are performed. Exposure variations are detected and quantified using analysis of image regions with an unobstructed view of the x-ray source. Translations that occur during the acquisition in the horizontal direction are detected, quantified, and corrected based on sinogram analysis. The axis of rotation is determined using registration of antiposed projection images. These techniques were evaluated using data obtained with calibration objects and phantoms. The physical geometric axis of rotation is determined and aligned with the rotational axis (assumed to be the center of the detector plane) used in the reconstruction process. The parameters describing this axis agree to within 0.1 mm and 0.3 deg with those determined using other techniques. Blurring due to residual calibration errors has a point-spread function in the reconstructed planes with a full-width-at-half-maximum of less than 125 {mu}m in a tangential direction and essentially zero in the radial direction for the rotating object. The authors have used this approach on over 100 acquisitions over the past 2 years and have regularly obtained high-quality reconstructions, i.e., without artifacts and no detectable blurring of the reconstructed objects. This self-calibrating approach not only obviates calibration runs, but it also provides quality control data for each data set.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗