Search NASA⌕ Search

SEARCH · Search NASA

Results for “Nuclear Data Evaluation Methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Comparing deflection measurements of a magnetically steerable catheter using optical imaging and MRI

Purpose: Magnetic resonance imaging (MRI) is an emerging modality for interventional radiology, giving clinicians another tool for minimally invasive image-guided interventional procedures. Difficulties associated with endovascular catheter navigation using MRI guidance led to the development of a magnetically steerable catheter. The focus of this study was to mechanically characterize deflections of two different prototypes of the magnetically steerable catheterin vitro to better understand their efficacy. Methods: A mathematical model for deflection of the magnetically steerable catheter is formulated based on the principle that at equilibrium the mechanical and magnetic torques are equal to each other. Furthermore, two different image based methods for empirically measuring the catheter deflection angle are presented. The first, referred to as the absolute tip method, measures the angle of the line that is tangential to the catheter tip. The second, referred to the base to tip method, is an approximation that is used when it is not possible to measure the angle of the tangent line. Optical images of the catheter deflection are analyzed using the absolute tip method to quantitatively validate the predicted deflections from the mathematical model. Optical images of the catheter deflection are also analyzed using the base to tip method to quantitatively determine the differences between the absolute tip and base to tip methods. Finally, the optical images are compared to MR images using the base to tip method to determine the accuracy of measuring the catheter deflection using MR. Results: The optical catheter deflection angles measured for both catheter prototypes using the absolute tip method fit very well to the mathematical model (R{sup 2} = 0.91 and 0.86 for each prototype, respectively). It was found that the angles measured using the base to tip method were consistently smaller than those measured using the absolute tip method. The deflection angles measured using optical data did not demonstrate a significant difference from the angles measured using MR image data when compared using the base to tip method. Conclusions: This study validates the theoretical description of the magnetically steerable catheter, while also giving insight into different methods and modalities for measuring the deflection angles of the prototype catheters. These results can be used to mechanically model future iterations of the design. Quantifying the difference between the different methods for measuring catheter deflection will be important when making deflection measurements in future studies. Finally, MR images can be used to reliably measure deflection angles since there is no significant difference between the MR and optical measurements.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poster — Thur Eve — 06: Dose assessment of cone beam CT imaging protocols as part of SPECT/CT examinations

Purpose: To assess radiation dose from the cone beam CT (CBCT) component of SPECT/CT studies and to compare with other CT examinations performed in our institution. Methods: We used an anthropomorphic chest phantom and the 6 cc ion chamber to measure entrance breast dose for several CBCT and diagnostic CT acquisition protocols. The CBCT effective dose was calculated with ImPACT software; the CT effective dose was evaluated from the DLP value and conversion factor, dependent on the anatomic region. The RADAR medical procedure radiation dose calculator was used to assess the nuclear medicine component of exam dose. Results: The entrance dose to the breast measured with the anthropomorphic phantom was 0.48 mGy and 9.41 mGy for cardiac and chest CBCT scans; and 4.59 mGy for diagnostic thoracic CT. The effective doses were 0.2 mSv, 3.2 mSv and 2.8 mSv respectively. For a small patient represented by the anthropomorphic phantom, the dose from the diagnostic CT was lower than from the CBCT scan, as a result of the exposure reduction options available on modern CT scanners. The CBCT protocols used the same fixed scanning techniques. The diagnostic CT dose based on the patient data was 35% higher than the phantom dose. For most SPECT/CT studies the dose from the CBCT component was comparable with the dose from the radiopharmaceutical. Conclusions: The patient radiation dose from the cone beam CT scan can be higher than that from a diagnostic CT and should be taken into consideration in evaluating total SPECT/CT patient dose.

60 APPLIED LIFE SCIENCES↗

The Need for Precise and Well-documented Experimental Data on Prompt Fission Neutron Spectra from Neutron-induced Fission of {sup 239}Pu

The spectrum of neutrons emitted promptly after {sup 239}Pu(n,f)—a so-called prompt fission neutron spectrum (PFNS)—is a quantity of high interest, for instance, for reactor physics and global security. However, there are only few experimental data sets available that are suitable for evaluations. In addition, some of those data sets differ by more than their 1-σ uncertainty boundaries. We present the results of MCNP studies indicating that these differences are partly caused by underestimated multiple scattering contributions, over-corrected background, and inconsistent deconvolution methods. A detailed uncertainty quantification for suitable experimental data was undertaken including these effects, and test-evaluations were performed with the improved uncertainty information. The test-evaluations illustrate that the inadequately estimated effects and detailed uncertainty quantification have an impact on the evaluated PFNS and associated uncertainties as well as the neutron multiplicity of selected critical assemblies. A summary of data and documentation needs to improve the quality of the experimental database is provided based on the results of simulations and test-evaluations. Given the possibly substantial distortion of the PFNS by multiple scattering and background effects, special care should be taken to reduce these effects in future measurements, e.g., by measuring the {sup 239}Pu PFNS as a ratio to either the {sup 235}U or {sup 252}Cf PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Development of Real-Time Quantitative Safety Evaluation Method for Nuclear Power Plants

Human operators involved with large process control systems such as nuclear power plants (NPPs) perform significant roles in the operation of systems. In this reason, deficiencies in human factors such as poor HSI (Human System Interface) design, procedure, and training, are significant contributing factors to NPPs incidents and accidents. In this regard, many kinds of studies including human reliability analysis (HRA), operation support system, automation, have been conducted in order to reduce human errors. Among these fields of studies, automation has its own specialty since it mainly focuses on eliminating the human error-inducing tasks to reduce human error, while other topics are primarily focusing on reducing human error by aiding human operators during operation. It is commonly believed that replacing human operators to the automated system would guarantee greater efficiency, lower workloads, and fewer human errors. However, these beliefs are not always true in large and complex systems such as NPP, since excessive automation can generate new roles for human operators, change human operators' activities in unexpected ways, and inducing 'out-of-the-loop' (OOTL) problem. Especially, although human error probability drastically increases during abnormal situations in NPP due to overload of information, high workload, and short time available for diagnosis, automation is not actively adopted since conventional machine learning techniques are neither capable nor reliable to handle overwhelmingly complex abnormal situations in NPP. Recently, newly developed 'deep learning' techniques have been actively applied to many fields, and some of these studies proved that the artificial intelligences (AI) based on deep learning techniques show better performance than that of human being. In 2015, deep Q-network (DQN) which is one of the deep learning techniques was developed and applied to train AI that automatically plays various Atari 2800 games, and this AI surpassed the human-level playing in many kind of games. Also in 2016, 'AlphaGo', which was developed by 'Google Deepmind' based on deep learning technique to play the game of Go, was defeated Se-dol Lee who is the World Go champion with score of 4:1. In the point of view that the game of Go is considered as one of the challenging area in machine learning field, it is verified that these new machine learning techniques can perform well, even better than the human being in high-complexity tasks. Previously, most of AI applications in nuclear field were focusing on supporting human operators' tasks such as diagnosis and decision making by rapid classification and prediction, based on fixed training data sets. However, it is expected that AI can be applied to solve more complicated problems (i.e. automation during abnormal states in NPP) by adopting advanced machine learning methodologies. In order to apply the automation system in NPP, firstly it is needed to evaluate the status of the plant quantitatively in real-time, since the information about which state is better (i.e. safe) or worse (i.e. unsafe) is essential for training properly working automation AI. Currently, there are several methodologies for NPP safety evaluation such as probabilistic safety assessment (PSA), safety performance indicator (SPI). However, existing methodologies are not feasible for development of automated system since they are not capable for the cases which are not included in the underlying model, not able to consider delicate changes in the NPP, and hard to evaluate in real-time. Therefore, development of new NPP safety evaluation methodology which can cover previously mentioned requirements is needed to conduct the study on NPP automation further. In this study, the concept of early warning score (EWS) in medical field was adopted to develop the methodology which can evaluate the safety level of the NPP quantitatively and in real-time. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rod internal pressure quantification and distribution analysis using Frapcon

This report documents work performed supporting the Department of Energy (DOE) Office of Nuclear Energy (NE) Fuel Cycle Technologies Used Fuel Disposition Campaign (UFDC) under work breakdown structure element 1.02.08.10, ST Analysis. In particular, this report fulfills the M4 milestone M4FT- 15OR0810036, Quantify effects of power uncertainty on fuel assembly characteristics, within work package FT-15OR081003 ST Analysis-ORNL. This research was also supported by the Consortium for Advanced Simulation of Light Water Reactors (http://www.casl.gov), an Energy Innovation Hub (http://www.energy.gov/hubs) for Modeling and Simulation of Nuclear Reactors under U.S. Department of Energy Contract No. DE-AC05-00OR22725. The discharge rod internal pressure (RIP) and cladding hoop stress (CHS) distributions are quantified for Watts Bar Nuclear Unit 1 (WBN1) fuel rods by modeling core cycle design data, operation data (including modeling significant trips and downpowers), and as-built fuel enrichments and densities of each fuel rod in FRAPCON-3.5. A methodology is developed which tracks inter-cycle assembly movements and assembly batch fabrication information to build individual FRAPCON inputs for each evaluated WBN1 fuel rod. An alternate model for the amount of helium released from the zirconium diboride (ZrB2) integral fuel burnable absorber (IFBA) layer is derived and applied to FRAPCON output data to quantify the RIP and CHS for these types of fuel rods. SCALE/Polaris is used to quantify fuel rodspecific spectral quantities and the amount of gaseous fission products produced in the fuel for use in FRAPCON inputs. Fuel rods with ZrB2 IFBA layers (i.e., IFBA rods) are determined to have RIP predictions that are elevated when compared to fuel rod without IFBA layers (i.e., standard rods) despite the fact that IFBA rods often have reduced fill pressures and annular fuel pellets. The primary contributor to elevated RIP predictions at burnups less than and greater than 30 GWd/MTU is determined to be the total fuel rod void volume and the amount of released fission gas in the fuel rod, respectively. Cumulative distribution functions (CDFs) are prepared from the distribution of RIP and CHS predictions for all standard and IFBA rods. The provided CDFs allow for the determination of the portion of WBN1 fuel rods that exceed a specified RIP or CHS limit. Results are separated into IFBA and standard rods so that the two groups may be analyzed individually. FRAPCON results are provided in sufficient detail to enable the recalculation of the RIP while considering any desired plenum gas temperature, total void volume, or total amount of gas present in the void volume. A method to predict the CHS from a determined or assumed RIP is also proposed, which is based on the approximately linear relationship between the CHS and the RIP. Finally, improvements to the computational methodology of FRAPCON are proposed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Metrics and Methods for Radiation Detection Algorithm Characterization for Nuclear/Radiological Source Search

This report presents a series of recommendations for data to train and evaluate radiation detection algorithms and performance metrics to evaluate these algorithms. These recommendations were formed through a community consensus approach through the Detection Radiation Algorithms Group (DRAG), a multi-institution collaboration spanning eight Department of Energy laboratories and John Hopkins Applied Physics Laboratory. This report includes recommendations on background data variability, and metrics to quantify variability, sources and shielding configurations to include in data collection campaigns and detector response variability. In addition, this report describes several anomaly detection and identification algorithms and recommends metrics to report their performance. Finally, this report ends with a discussion on machine learning algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTING FIRE WITH MACHINE LEARNING-ENABLED VISUAL MONITORING FOR NUCLEAR POWER PLANT ENVIRONMENTS

Nuclear power plants are experiencing significant cost challenges to remain competitive with other energy-generation utilities. Unlike other industries, the cost of operation and maintenance activities is mostly attributed to workforce costs. To mitigate this, nuclear power plant stakeholders are increasingly interested in the development and deployment of machine learning methods to potentially automate or augment manually intensive tasks to reduce costs, especially for monitoring activities. One monitoring function that is visually demanding and that can occur frequently to meet the requirements of a fire protection program is visually monitoring an area for fire occurrence. Currently, fire watch activities consist of a worker physically stationed at a given location with the sole responsibility of observing a given area to ensure a fire is detected and mitigated promptly. This effort focused on the development and evaluation of a suitable deep convolutional neural network to classify individual video frames at a sub-second frequency for the occurrence of “fire” and “no fire” in varying industrial environments similar to nuclear power plants. It is believed that a trained neural network model could be integrated with existing facility video surveillance camera feeds to generate alerts when fire inferences occur in individual frames captured at sub-second temporal resolutions. Extensive effort was dedicated to identifying and curating suitable imagery training data representing varying environments and scene settings with and without flame features to maximize generalization in nuclear power plant environments. The data collection effort resulted in the aggregation of a large, labeled image library exceeding 12,000 images to support model training for diverse industrial environments. A deep neural network model incorporating parallel multi-scale capabilities was developed and trained to support accurate image-based detection of flame incidents of varying sizes and spectral feature properties within heterogeneous scenes. Analysis results show that the trained model can achieve high inference accuracy despite heterogeneous scene environments and components. Testing accuracy exceeded 95.0 percent with very low false positive and false negative inferences.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of Analytical Hierarchy Process for Narrowing Down Nep Candidate Reactor Designs

Nuclear electric propulsion (NEP)-powered vehicles have been contemplated for human Mars missions. The nuclear power system contemplates using a high temperature light-weight nuclear reactor for the production of electrical power in the range of 2-5 MWe with a 3-10 year service life. A myriad of technology options exist for achieving these mission objectives. The analytic hierarchy process (AHP), a multi-attribute decision method, is being used to narrow down the candidate designs. The AHP is a structured decision process that fuses model-supplied quantitative data with subjective assessments to facilitate decisions that involve multiple competing criteria. Proven end-to-end nuclear design and systems analysis tools will be used to provide quantitative performance data such as end-to-end system reliability, system robustness to recover from off-normal conditions, system specific weight (α in kg/kWe), and the ability to meet the service life-time and power level requirements. Three high assay low enriched uranium (HALEU) reactor concepts, namely, gas-, heat pipe- and pumped liquid-cooled nuclear cores coupled to a He/Xe gas or supercritical CO2- Brayton power conversion system are being modeled using the AHP to understand the trade-offs associated with these design combinations. In addition to the reactor and power conversion options, there are a myriad of additional components and subsystems – e.g., radiators, heat exchangers, and recuperators – that also figure into the evaluation process. The choice of the right overall system is a multidimensional problem that has to include not only quantitative data, but also the so called “external factors”, examples of which include the component and subsystem Technology Readiness Levels (TRLs), the associated Advancement Degrees of Difficulty (AD2), the cost and schedule required to achieve a technical maturity consistent with mission infusion, alignment with the priorities of NASA’s Space Nuclear Propulsion program, and alignment with other ongoing government and commercial investments in micro reactors. Focused expert elicitations form the basis for qualitative data set. As a final step, decision-makers individually express their opinions regarding the relative importance of the criteria and preferences among the alternatives through pairwise comparisons. The paper will describe the AHP approach, progress to-date applying it to the NEP human Mars mission problem, and preliminary results. Use of AHP provides sufficient flexibility for incorporating industry input at different stages as the technologies evolve through additional research and development. It is expected that the decision process will be ongoing and expanded to examine additional options and technology choices, culminating in a defensible set of candidate reactor concepts that will form the basis for developing a multi-year NEP technology maturation strategy. .

Dasari V Rao↗

The prediction of Neutron Elastic Scattering from Tritium for E(n) = 6-14 MeV

In a recent report Navratil et al. evaluated the angle-integrated cross section and the angular distribution for 14-MeV n+T elastic scattering by inferring these cross sections from accurately measured p+3He angular distributions. This evaluation used a combination of two theoretical treatments, based on the no-core shell model and resonating-group method (NCSM/RGM) and on the R-matrix formalism, to connect the two charge-symmetric reactions n+T and p+{sup 3}He. In this report we extend this treatment to cover the neutron incident energy range 6-14 MeV. To do this, we evaluate angle-dependent correction factors for the NCSM/RGM calculations so that they agree with the p+{sup 3}He data near 6 MeV, and using the results found earlier near 14 MeV we interpolate these correction factors to obtain correction factors throughout the 6-14 MeV energy range. The agreement between the corrected NCSM/RGM and R-Matrix values for the integral elastic cross sections is excellent ({+-}1%), and these are in very good agreement with total cross section experiments. This result can be attributed to the nearly constant correction factors at forward angles, and to the evidently satisfactory physics content of the two calculations. The difference in angular shape, obtained by comparing values of the scattering probability distribution P({mu}) vs. {mu}(the cosine of the c.m. scattering angle), is about {+-}4% and appears to be related to differences in the two theoretical calculations. Averaging the calculations yields P({mu}) values with errors of {+-}2 1/2 % or less. These averaged values, along with the corresponding quantities for the differential cross sections, will form the basis of a new evaluation of n+T elastic scattering. Computer files of the results discussed in this report will be supplied upon request.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Point Kinetics Model for Estimating Neutron Multiplication of Bare Uranium Metal in Tagged Neutron Measurements

An extension of the point kinetics model is developed in this paper to describe the neutron multiplicity response of a bare uranium object under interrogation by an associated particle imaging deuterium-tritium (D-T) measurement system. This extended model is used to estimate the total neutron multiplication of the uranium. Both MCNPX-PoliMi simulations and data from active interrogation measurements of highly enriched and depleted uranium geometries are used to evaluate the potential of this method and to identify the sources of systematic error. The detection efficiency correction for measured coincidence response is identified as a large source of systematic error. If the detection process is not considered, results suggest that the method can estimate total multiplication to within 13% of the simulated value. Values for multiplicity constants in the point kinetics equations are sensitive to enrichment due to (n, xn) interactions by D-T neutrons and can introduce another significant source of systematic bias. This can theoretically be corrected if isotopic composition is known a priori. Finally, the spatial dependence of multiplication is also suspected of introducing further systematic bias for high multiplication uranium objects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Grating-based x-ray differential phase contrast imaging with twin peaks in phase-stepping curves—phase retrieval and dewrapping

Purpose: X-ray differential phase contrast CT implemented with Talbot interferometry employs phase-stepping to extract information of x-ray attenuation, phase shift, and small-angle scattering. Since inaccuracy may exist in the absorption grating G{sub 2} due to an imperfect fabrication, the effective period of G{sub 2} can be as large as twice the nominal period, leading to a phenomenon of twin peaks that differ remarkably in their heights. In this work, the authors investigate how to retrieve and dewrap the phase signal from the phase-stepping curve (PSC) with the feature of twin peaks for x-ray phase contrast imaging. Methods: Based on the paraxial Fresnel–Kirchhoff theory, the analytical formulae to characterize the phenomenon of twin peaks in the PSC are derived. Then an approach to dewrap the retrieved phase signal by jointly using the phases of the first- and second-order Fourier components is proposed. Through an experimental investigation using a prototype x-ray phase contrast imaging system implemented with Talbot interferometry, the authors evaluate and verify the derived analytic formulae and the proposed approach for phase retrieval and dewrapping. Results: According to theoretical analysis, the twin-peak phenomenon in PSC is a consequence of combined effects, including the inaccuracy in absorption grating G{sub 2}, mismatch between phase grating and x-ray source spectrum, and finite size of x-ray tube’s focal spot. The proposed approach is experimentally evaluated by scanning a phantom consisting of organic materials and a lab mouse. The preliminary data show that compared to scanning G{sub 2} over only one single nominal period and correcting the measured phase signal with an intuitive phase dewrapping method that is being used in the field, stepping G{sub 2} over twice its nominal period and dewrapping the measured phase signal with the proposed approach can significantly improve the quality of x-ray differential phase contrast imaging in both radiograph and CT. Conclusions: Using the phase retrieval and dewrapping methods proposed to deal with the phenomenon of twin peaks in PSCs and phase wrapping, the performance of grating-based x-ray differential phase contrast radiography and CT can be significantly improved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Challenges of Using Indistinguishable from Background as a Release Criterion at FUSRAP Projects - 18157

The US Army Corps of Engineers (USACE) utilizes the Multi-Agency Radiation Survey and Site Investigation Manual (MARSSIM) approach to site release on Formerly Utilized Sites Remedial Action Program (FUSRAP) projects. Use of Indistinguishable from Background (IFB) as a release criterion is discussed in MARSSIM as Scenario B; however, the discussion is arguably limited and refers the user to other documents. USACE has utilized the IFB approach at select FUSRAP projects. USACE experience is that use of IFB as a release criterion has been difficult to implement at best. There are many challenges in using the IFB approach. These include: release criterion is required per MARSSIM; multiple reference areas need to be established; and data presentation. Potential methods to overcome these challenges are discussed. USACE has utilized alternative statistical approaches as well as the IFB approach discussed in MARSSIM for specific purposes at FUSRAP sites. Alternatives to the IFB approach discussed in this paper include other statistical tests such as the Tukey Kramer test. These alternatives may be better suited to release an area of a property prior to the development of release criteria. USACE has found using the IFB criterion useful in certain specific circumstances. These include post MARSSIM Scenario A final status survey data evaluations and for review of historical data. The challenges, alternatives, and circumstances to use the IFB approach are discussed. Other environmental remediation projects attempting to utilize IFB as a criterion may benefit from the USACE experiences as discussed herein. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Clinical Validation of 4-Dimensional Computed Tomography Ventilation With Pulmonary Function Test Data

Purpose: A new form of functional imaging has been proposed in the form of 4-dimensional computed tomography (4DCT) ventilation. Because 4DCTs are acquired as part of routine care for lung cancer patients, calculating ventilation maps from 4DCTs provides spatial lung function information without added dosimetric or monetary cost to the patient. Before 4DCT-ventilation is implemented it needs to be clinically validated. Pulmonary function tests (PFTs) provide a clinically established way of evaluating lung function. The purpose of our work was to perform a clinical validation by comparing 4DCT-ventilation metrics with PFT data. Methods and Materials: Ninety-eight lung cancer patients with pretreatment 4DCT and PFT data were included in the study. Pulmonary function test metrics used to diagnose obstructive lung disease were recorded: forced expiratory volume in 1 second (FEV1) and FEV1/forced vital capacity. Four-dimensional CT data sets and spatial registration were used to compute 4DCT-ventilation images using a density change–based and a Jacobian-based model. The ventilation maps were reduced to single metrics intended to reflect the degree of ventilation obstruction. Specifically, we computed the coefficient of variation (SD/mean), ventilation V20 (volume of lung ≤20% ventilation), and correlated the ventilation metrics with PFT data. Regression analysis was used to determine whether 4DCT ventilation data could predict for normal versus abnormal lung function using PFT thresholds. Results: Correlation coefficients comparing 4DCT-ventilation with PFT data ranged from 0.63 to 0.72, with the best agreement between FEV1 and coefficient of variation. Four-dimensional CT ventilation metrics were able to significantly delineate between clinically normal versus abnormal PFT results. Conclusions: Validation of 4DCT ventilation with clinically relevant metrics is essential. We demonstrate good global agreement between PFTs and 4DCT-ventilation, indicating that 4DCT-ventilation provides a reliable assessment of lung function. Four-dimensional CT ventilation enables exciting opportunities to assess lung function and create functional avoidance radiation therapy plans. The present work provides supporting evidence for the integration of 4DCT-ventilation into clinical trials.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Preservation of FFTF Data Related to Passive Safety Testing

One of the goals of the Fuel Cycle Research and Development Program (FCRD) is to preserve the knowledge that has been gained in the United States on Liquid Metal Reactors (LMR). A key area deserving special attention for preservation is the data relating to passive safety testing that was conducted in FFTF and EBR-II during the 1980’s. Accidents at Unit 4 of the Chernobyl Station and Unit 2 at Three Mile Island changed the safety paradigm of the nuclear power industry. New emphasis was placed on assured safety based on intrinsic plant characteristics that protect not only the public, but the significant investment in the plant as well. Plants designated to perform in this manner are considered to be passively safe since no active sensor/alarm system or human intervention is required to bring the reactor to a safe shutdown condition. The liquid metal reactor (LMR) has several key characteristics needed for a passively safe reactor: reactor coolant with superior heat transfer capability and very high boiling point, low (atmospheric) system pressures, and reliable negative reactivity feedback. The credibility of the design for a passively safe LMR rests on two issues: the validity of analytic methods used to predict passive safety performance and the availability of relevant test data to calibrate design tools. Safety analysis methods used to analyze LMRs under the old safety paradigm were focused on calculating the source term for the Core Disruptive Accident. Passive safety design requires refined analysis methods for transient events because treatment of the detailed reactivity feedbacks is important in predicting the response of the reactor. Similarly, analytic tools should be calibrated against actual test experience in existing LMR facilities. The principal objectives of the combined FFTF natural circulation and Passive Safety Testing program were: 1) to verify natural circulation as a reliable means to safely remove decay heat, 2) to extend passive safety experience to a large-size LMR and obtain data for validating design analysis computer codes, and 3) to develop and test passive safety enhancements that might be used for future LMRs. These tests were designed to provide data sufficient to allow separation of fuel temperature effects from structural temperature effects. The data developed through this testing program were used to verify the predictive capability of passive safety analysis methods as well as provide a data base for calibrating design tools such as the SASSYS/SAS4A codes. These tests were instrumental in improving understanding of reactivity feedback mechanisms in LMRs and demonstrating passive safety margins available in an LMR. Knowledge preservation at the FFTF is focused on the areas of design, construction, startup, and operation of the reactor. This information may be of potential use for international exchanges with other LMR programs around the world. This information provides the basis for creating benchmarks for validating and testing large scale computer programs. All information preserved to date is now being stored and categorized consistent with the IAEA international standardized taxonomy. The test results information exists in several different formats depending upon the final stage of the test evaluation. Over 100 documents relevant to passive safety testing have been identified and are being recovered, scanned, and catalogued. Attempts to recover plant data tapes are also in progress. Documents related to passive safety testing are now being categorized consistent with internationally agreed upon IAEA standards. Documents are being converted to electronic format compatible with a general search engine being developed by INL. The data from the FFTF passive safety tests provides experimental verification of structural reactivity effects that should be very useful to innovative designers seeking to optimize passive safety in the design of new LMRs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Evaluation of high-energy brachytherapy source electronic disequilibrium and dose from emitted electrons

Purpose: The region of electronic disequilibrium near photon-emitting brachytherapy sources of high-energy radionuclides ({sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb) and contributions to total dose from emitted electrons were studied using the GEANT4 and PENELOPE Monte Carlo codes. Methods: Hypothetical sources with active and capsule materials mimicking those of actual sources but with spherical shape were examined. Dose contributions due to source photons, x rays, and bremsstrahlung; source {beta}{sup -}, Auger electrons, and internal conversion electrons; and water collisional kerma were scored. To determine if conclusions obtained for electronic equilibrium conditions and electron dose contribution to total dose for the representative spherical sources could be applied to actual sources, the {sup 192}Ir mHDR-v2 source model (Nucletron B.V., Veenendaal, The Netherlands) was simulated for comparison to spherical source results and to published data. Results: Electronic equilibrium within 1% is reached for {sup 60}Co, {sup 137}Cs, {sup 192}Ir, and {sup 169}Yb at distances greater than 7, 3.5, 2, and 1 mm from the source center, respectively, in agreement with other published studies. At 1 mm from the source center, the electron contributions to total dose are 1.9% and 9.4% for {sup 60}Co and {sup 192}Ir, respectively. Electron emissions become important (i.e., >0.5%) within 3.3 mm of {sup 60}Co and 1.7 mm of {sup 192}Ir sources, yet are negligible over all distances for {sup 137}Cs and {sup 169}Yb. Electronic equilibrium conditions along the transversal source axis for the mHDR-v2 source are comparable to those of the spherical sources while electron dose to total dose contribution are quite different. Conclusions: Electronic equilibrium conditions obtained for spherical sources could be generalized to actual sources while electron contribution to total dose depends strongly on source dimensions, material composition, and electron spectra.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neurohumoral indicators of efficacy radiofrequency cardiac denervation

In this study, we compared pre- and postoperative parameters of the cardiac sympathetic innervation. The aim of the study was to examine the approaches to evaluating the quality of radiofrequency (RF)-induced cardiac denervation by using non-invasive and laboratory methods. The study included 32 people with long-lasting persistent atrial fibrillation (AF). The patients were divided into 2 groups according to the objectives of the study: group 1 (main) - 21 patients with mitral valve diseases, which simultaneously with radiofrequency ablation (RFA) AF carried out on the effects of the paraganglionic nervous plexuses by C. Pappone (2004) and N. Doll (2008) schemes. The second group (control) contained 11 patients with heart diseases in sinus rhythm (the RF denervation not been performed). All patients, who underwent surgical treatment, were received examination of cardiac sympathetic tone by using {sup 123}I-MIBG. All of them made blood analysis from ascending aorta and coronary sinus to determine the level of norepinephrine and its metabolites before and after cardiac denervation. Data of radionuclide examination are correlating with laboratory data.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Are We Appropriately Selecting Therapy For Patients With Cervical Cancer? Longitudinal Patterns-of-Care Analysis for Stage IB-IIB Cervical Cancer

Purpose: We performed a patterns-of-care analysis evaluating the effects of newer technology and recent research findings on treatment decisions over 26 years to determine whether patients with cervical cancer are being appropriately selected for treatment to optimize the therapeutic ratio. Methods and Materials: A retrospective analysis was conducted using the Surveillance, Epidemiology and End Results (SEER) program from 1983 to 2009. We identified 10,933 women with stage IB-IIB cervical carcinoma. Results: Of the 10,933 subjects identified, 40.1% received surgery, 26.8% received radiation (RT), and 33.1% received surgery plus RT. RT use increased after 2000 compared to prior to 2000, with a corresponding decrease in surgery and surgery plus RT. Among patients with risk factors including tumor size >4 cm, positive parametria, and positive lymph nodes, declining use of surgery plus RT was observed. However, 23% of patients with tumors >4 cm, 20% of patients with positive parametria, and 55% of node-positive patients continued to receive surgery plus RT as of 2009. Factors associated with increased use of surgery plus RT included patient age <50 and node-positive status. Conclusions: In this largest patterns-of-care analysis to date for patients with locally advanced cervical cancer, we found a substantial proportion of patients continue to undergo surgery followed by radiation, despite randomized data supporting the use of definitive radiation therapy, with lower morbidity than surgery and radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Doses to Carotid Arteries After Modern Radiation Therapy for Hodgkin Lymphoma: Is Stroke Still a Late Effect of Treatment?

Purpose: Hodgkin lymphoma (HL) survivors are at an increased risk of stroke because of carotid artery irradiation. However, for early-stage HL involved node radiation therapy (INRT) reduces the volume of normal tissue exposed to high doses. Here, we evaluate 3-dimensional conformal radiation therapy (3D-CRT), volumetric-modulated arc therapy (VMAT), and proton therapy (PT) delivered as INRT along with the extensive mantle field (MF) by comparing doses to the carotid arteries and corresponding risk estimates. Methods and Materials: We included a cohort of 46 supradiaphragmatic stage I-II classical HL patients. All patients were initially treated with chemotherapy and INRT delivered as 3D-CRT (30 Gy). For each patient, we simulated MF (36 Gy) and INRT plans using VMAT and PT (30 Gy). Linear dose-response curves for the 20-, 25-, and 30-year risk of stroke were derived from published HL data. Risks of stroke with each technique were calculated for all patients. Statistical analyses were performed with repeated measures analysis of variance. Results: The mean doses to the right and left common carotid artery were significantly lower with modern treatment compared with MF, with substantial patient variability. The estimated excess risk of stroke after 20, 25, and 30 years was 0.6%, 0.86%, and 1.3% for 3D-CRT; 0.67%, 0.96%, and 1.47% for VMAT; 0.61%, 0.96%, and 1.33% for PT; and 1.3%, 1.72%, and 2.61% for MF. Conclusions: INRT reduces the dose delivered to the carotid arteries and corresponding estimated risk of stroke for HL survivors. Even for the subset of patients with lymphoma close to the carotid arteries, the estimated risk is low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗