Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Formation of high quality interference fringes from both sides of a suitably designed hololens in the laser Doppler anemometer measurement volume

We report, for the first time to the best of our knowledge, the formation of high quality, evenly spaced, undistorted fringes in the measurement volume of a laser Doppler anemometer from both sides of a suitably designed hololens. Experiments are performed for the analysis of fringes formed at the measurement volume by real time monitoring and actual fringe field analysis techniques. The results indicate the qualitative as well as quantitative improvement of 66.58% in overall average normalised standard deviations of the width of the fringes formed by the proposed imaging configuration than that of the conventional imaging configuration. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of the B s 0 → μ + μ - Branching Fraction and Effective Lifetime and Search for B 0 → μ + μ - Decays

A search for the rare decays $B^0_s$→$μ$ + $μ$ - and B 0 →$μ$ + $μ$ - is performed at the LHCb experiment using data collected in pp collisions corresponding to a total integrated luminosity of 4.4 fb -1 . An excess of $B^0_s$→$μ$ + $μ$ - decays is observed with a significance of 7.8 standard deviations, representing the first observation of this decay in a single experiment. The branching fraction is measured to be $B$($μ$ + $μ$ - )=(3.0 ± $0.6^{+0.3}_{-0.2}$) × 10 -9 , where the first uncertainty is statistical and the second systematic. The first measurement of the $B^0_s$→$μ$ + $μ$ - effective lifetime, τ($B^0_s$→($μ$ + $μ$ - ) = 2.04 ± 0.44 ± 0.05 ps, is reported. No significant excess of B 0 →($μ$ + $μ$ - decays is found, and a 95% confidence level upper limit, $B$(B 0 →($μ$ + $μ$ - ) < 3.4 × 10 -10 , is determined. All results are in agreement with the standard model expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-J-217: Accuracy Comparison Between Surface and Volumetric Registrations for Patient Setup of Head and Neck Radiation Therapy

Purpose: Optical surface imaging has been applied to radiation therapy patient setup. This study aims to investigate the accuracy of the surface registration of the optical surface imaging compared with that of the conventional method of volumetric registration for patient setup in head and neck radiation therapy. Methods: Clinical datasets of planning CT and treatment Cone Beam CT (CBCT) were used to compare the surface and volumetric registrations in radiation therapy patient setup. The Iterative Closest Points based on point-plane closest method was implemented for surface registration. We employed 3D Slicer for rigid volumetric registration of planning CT and treatment CBCT. 6 parameters of registration results (3 rotations and 3 translations) were obtained by the two registration methods, and the results were compared. Digital simulation tests in ideal cases were also performed to validate each registration method. Results: Digital simulation tests showed that both of the registration methods were accurate and robust enough to compare the registration results. In experiments with the actual clinical data, the results showed considerable deviation between the surface and volumetric registrations. The average root mean squared translational error was 2.7 mm and the maximum translational error was 5.2 mm. Conclusion: The deviation between the surface and volumetric registrations was considerable. Special caution should be taken in using an optical surface imaging. To ensure the accuracy of optical surface imaging in radiation therapy patient setup, additional measures are required. This research was supported in part by the KIST institutional program (2E24551), the Industrial Strategic technology development program (10035495) funded by the Ministry of Trade, Industry and Energy (MOTIE, KOREA), and the Radiation Safety Research Programs (1305033) through the Nuclear Safety and Security Commission, and the NIH (R01EB016777)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-25: Position Monitoring for Intracranial SRS Using BrainLAB ExacTrac Snap Verification

Purpose: To determine the accuracy of position monitoring with BrainLAB ExacTrac snap verification following couch rotations during intracranial SRS. Methods: A CT scan of an anthropomorphic head phantom was acquired using 1.25mm slices. The isocenter was positioned near the centroid of the frontal lobe. The head phantom was initially aligned on the treatment couch using cone-beam CT, then repositioned using ExacTrac x-ray verification with residual errors less than 0.2mm and 0.2°. Snap verification was performed over the full range of couch angles in 15° increments with known positioning offsets of 0–3mm applied to the phantom along each axis. At each couch angle, the smallest tolerance was determined for which no positioning deviation was detected. Results: For couch angles 30°–60° from the center position, where the longitudinal axis of the phantom is approximately aligned with the beam axis of one x-ray tube, snap verification consistently detected positioning errors exceeding the maximum 8mm tolerance. Defining localization error as the difference between the known offset and the minimum tolerance for which no deviation was detected, the RMS error is mostly less than 1mm outside of couch angles 30°–60° from the central couch position. Given separate measurements of patient position from the two imagers, whether to proceed with treatment can be determined by the criterion of a reading within tolerance from just one (OR criterion) or both (AND criterion) imagers. Using a positioning tolerance of 1.5mm, snap verification has sensitivity and specificity of 94% and 75%, respectively, with the AND criterion, and 67% and 93%, respectively, with the OR criterion. If readings exceeding maximum tolerance are excluded, the sensitivity and specificity are 88% and 86%, respectively, with the AND criterion. Conclusion: With a positioning tolerance of 1.5mm, ExacTrac snap verification can be used during intracranial SRS with sensitivity and specificity between 85% and 90%.

60 APPLIED LIFE SCIENCES↗

Replication Data for: Measurement of the mean number of muons with energies above 500 GeV in air showers detected with the IceCube Neutrino Observatory

<b>Measurement of the mean number of muons with energies above 500 GeV in air showers detected with the IceCube Neutrino Observatory</b> <br><br> This data release accompanies results submitted to Physical Review D describing the measurement of the average multiplicity of TeV muons with IceCube. It contains the data necessary to reproduce the main plots from the paper (Figs. 7 and 9), i.e. the numerical results for the average number of muons with energies above 500 GeV as a function of primary cosmic ray energy. <br><br> For any questions about this data release, please write to analysis@icecube.wisc.edu. <br><br> Files included in this release: <ul> <li>A README file <li>Files including data to reproduce the results plots from the paper (see below for details) <li>An example python script showing how to read and plot the data </ul> <br> <u>What is in the files icecube_Nmu500_X_Y.txt:</u> <br> Y indicates wether the file contains values obtained from experimental data (Y="data") or air-shower simulations (Y="MC"). <br> X indicates the hadronic interaction model for which the plot is made. If Y="data", this means that the experimental data was interpreted using this model. If Y="MC", it means that the simulations were performed with this model. The three models included are Sibyll 2.1, QGSJet-II.04, and EPOS-LHC (see paper for references). The file with X="modelaverage" gives the average over the three individual results with the deviations from the average included in the systematic uncertainties. <br><br> Please see the README file for details on how the data is structured in the files.

Astroparticle Physics↗

Palus Somni - Anomalies in the correlation of Al/Si X-ray fluorescence intensity ratios and broad-spectrum visible albedos

The positive correlation between Al/Si X-ray fluorescence intensity ratios determined during the Apollo 15 lunar mission and a broad-spectrum visible albedo of the moon is quantitatively established. Linear regression analysis performed on 246 1 degree geographic cells of X-ray fluorescence intensity and visible albedo data points produced a statistically significant correlation coefficient of .78. Three distinct distributions of data were identified as (1) within one standard deviation of the regression line, (2) greater than one standard deviation below the line, and (3) greater than one standard deviation above the line. The latter two distributions of data were found to occupy distinct geographic areas in the Palus Somni region.

Clark, P. E.↗

A description and evaluation of TIMER: A time-based terminal flow-control concept

A description of a time-based ATC concept called TIMER (Traffic Intelligence for the Management of Efficient Runway-scheduling) and the results of a fast time and real time computer evaluation are presented. The concept was designed to improve the efficiency of extended terminal area operations (en route approach, transition, and terminal flight to the runway). TIMER integrates en route metering, fuel efficient cruise and profile descents, terminal sequencing and spacing together with computer-generated controller aids, in order to fully use runway capacity and improve efficiency of delay absorption. The concept, by using simplified aircraft models, accommodates both 4-D and non 4-D equipped aircraft and is designed for integration into the manual, voice linked ATC system in an evolutionary manner and still be able to accommodate proposed system upgrade features such as data link and further ground automation. Fast time and real time computer simulation results identify and show the effects and interactions of such key variables as horizon of control, metering fix and final approach delivery time errors, aircraft separation requirements, delay discounting, wind, flight technical error, and knowledge of aircraft final approach speed. The current ATC system has a runway interarrival-error standard deviation of approx. 26 seconds. Simulation results indicate that, with computer aiding, the runway interarrival-error standard deviation for non 4-D equipped traffic can be reduced to the region of 8 to 12 seconds if expected final approach speed is known; however, the reduction is only in the region of 16 to 20 seconds if expected final approach speed is unknown. Another major finding is that en route metering fix delivery-error standard deviation should be kept to less than a number somewhere between 35 to 45 seconds to achieve full runway capacity. This requirement implies the need for either airborne automation or assistance to the controller since the current manual performance in today's en route metering environment is in the order of 1.5 minutes.

Credeur, Leonard↗

A Detailed Investigation of Staged Normal Injection into a Mach 2 Flow

A study of the staged injection of two jets of air behind a rearward facing step into a Mach 2 flow was performed using the SPARK 3-D Navier-Stokes code. Calculated mole fraction distributions were compared with an extensive set of planar mole fraction measurements made with a laser induced iodine fluorescence technique. A statistical measure, the standard deviation, was used to help assess agreement between calculation and experiment. Overall, good agreement was found between calculated and measured values. Generally, agreement was better in the far field of the injectors. The effect of grid resolution was investigated by calculating solutions on grids of 60,000, 200,000, and 450,000 points. Differences in the solutions on the two finer grids were small. However, the mole fraction distributions were distinguishable. The effect of turbulence modeling was investigated by employing three different algebraic models for the jet turbulence: the Baldwin-Lomax model, the Prandtl mixing length model, and the Eggers mixing length model. Overall, the Eggers mixing length model was found to be superior for this case. Finally, the effect of the jet exit conditions was examined. A recently proposed Mach number distribution at the jet exit was found to slightly improve agreement between measurement and calculation.

Eklund, Dean R.↗

Probabilistic Material Strength Degradation Model for Inconel 718 Components Subjected to High Temperature, Mechanical Fatigue, Creep and Thermal Fatigue Effects

This thesis presents the on-going development of methodology for a probabilistic material strength degradation model. The probabilistic model, in the form of a postulated randomized multifactor equation, provides for quantification of uncertainty in the lifetime material strength of aerospace propulsion system components subjected to a number of diverse random effects. This model is embodied in the computer program entitled PROMISS, which can include up to eighteen different effects. Presently, the model includes four effects that typically reduce lifetime strength: high temperature, mechanical fatigue, creep, and thermal fatigue. Statistical analysis was conducted on experimental Inconel 718 data obtained from the open literature. This analysis provided regression parameters for use as the model's empirical material constants, thus calibrating the model specifically for Inconel 718. Model calibration was carried out for four variables, namely, high temperature, mechanical fatigue, creep, and thermal fatigue. Methodology to estimate standard deviations of these material constants for input into the probabilistic material strength model was developed. Using the current version of PROMISS, entitled PROMISS93, a sensitivity study for the combined effects of mechanical fatigue, creep, and thermal fatigue was performed. Results, in the form of cumulative distribution functions, illustrated the sensitivity of lifetime strength to any current value of an effect. In addition, verification studies comparing a combination of mechanical fatigue and high temperature effects by model to the combination by experiment were conducted. Thus, for Inconel 718, the basic model assumption of independence between effects was evaluated. Results from this limited verification study strongly supported this assumption.

Bast, Callie Corinne Scheidt↗

Radio-science performance analysis software

The Radio Science Systems Group (RSSG) provides various support functions for several flight project radio-science teams. Among these support functions are uplink and sequence planning, real-time operations monitoring and support, data validation, archiving and distribution functions, and data processing and analysis. This article describes the support functions that encompass radio-science data performance analysis. The primary tool used by the RSSG to fulfill this support function is the STBLTY program set. STBLTY is used to reconstruct observable frequencies and calculate model frequencies, frequency residuals, frequency stability in terms of Allan deviation, reconstructed phase, frequency and phase power spectral density, and frequency drift rates. In the case of one-way data, using an ultrastable oscillator (USO) as a frequency reference, the program set computes the spacecraft transmitted frequency and maintains a database containing the in-flight history of the USO measurements. The program set also produces graphical displays. Some examples and discussions on operating the program set on Galileo and Ulysses data will be presented.

Morabito, D. D.↗

A geopotential model from satellite tracking, altimeter, and surface gravity data: GEM-T3

An improved model of Earth's gravitational field, Goddard Earth Model T-3 (GEM-T3), has been developed from a combination of satellite tracking, satellite altimeter, and surface gravimetric data. GEM-T3 provides a significant improvement in the modeling of the gravity field at half wavelengths of 400 km and longer. This model, complete to degree and order 50, yields more accurate satellite orbits and an improved geoid representation than previous Goddard Earth Models. GEM-T3 uses altimeter data from GEOS 3 (1975-1976), Seasat (1978) and Geosat (1986-1987). Tracking information used in the solution includes more than 1300 arcs of data encompassing 31 different satellites. The recovery of the long-wavelength components of the solution relies mostly on highly precise satellite laser ranging (SLR) data, but also includes Tracking Network (TRANET) Doppler, optical, and satellite-to-satellite tracking acquired between the ATS 6 and GEOS 3 satellites. The main advances over GEM-T2 (beyond the inclusion of altimeter and surface gravity information which is essential for the resolution of the shorter wavelength geoid) are some improved tracking data analysis approaches and additional SLR data. Although the use of altimeter data has greatly enhanced the modeling of the ocean geoid between 65 deg N and 60 deg S latitudes in GEM-T3, the lack of accurate detailed surface gravimetry leaves poor geoid resolution over many continental regions of great tectonic interest (e.g., Himalayas, Andes). Estimates of polar motion, tracking station coordinates, and long-wavelength ocean tidal terms were also made (accounting for 6330 parameters). GEM-T3 has undergone error calibration using a technique based on subset solutions to produce reliable error estimates. The calibration is based on the condition that the expected mean square deviation of a subset gravity solution from the full set values is predicted by the solutions' error covariances. Data weights are iteratively adjusted until this condition for the error calibration is satisfied. In addition, gravity field tests were performed on strong satellite data sets withheld from the solution (thereby ensuring their independence). In these tests, the performance of the subset models on the withheld observations is compared to error projections based on their calibrated error covariances. These results demonstrate that orbit accuracy projections are reliable for new satellites which were not included in GEM-T3.

Lerch, F. J.↗

[Assessment of the risk factors for urolithiasis in cosmonauts during long flights]

Twelve cosmonauts flown aboard the Mir orbital station for 6-12 months and twelve candidates for cosmonauts were examined in an effort to determine a degree of urolithiasis risk. Prior to flight, on flight day 310 (in one cosmonaut) and after flight, the daily urinary excretion of the components influencing lithiasis formation was determined as well as a computer-aided calculation of urine saturation by lithogenic salts was performed (Ch. Pak, USA). In the in- and postflight periods, the greater number of indices under study were negatively changed in cosmonauts. Excretion dynamics of the lithogenesis inhibitors, i.e., citrates and magnesium, is of polar directionality. Frequency of deviations from the normal indices of urolithic risk in cosmonauts is primarily conditioned by low diuresis, urine supersaturation with calcium oxalate, undissociated uric acid, brushit, hypercalciuria, and changed pH.

Flight Experiment↗

Multi-Parameter Nonlinear Gain Correction of X-Ray Transition Edge Sensors for the X-Ray Integral Field Unit

With its array of 3840 Transition Edge Sensors (TESs), the Athena X-ray Integral Field Unit (X-IFU) will provide spatially resolved high-resolution spectroscopy (2.5 eV up to 7 keV) from 0.2 to 12 keV, with an absolute energy scale accuracy of 0.4 eV. Slight changes in the TES operating environment can cause significant variations in its energy response function, which may result in systematic errors in the absolute energy scale. We plan to monitor such changes at pixel level via onboard X-ray calibration sources and correct the energy scale accordingly using a linear or quadratic interpolation of gain curves obtained during ground calibration. However, this may not be sufficient to meet the 0.4 eV accuracy required for the XIFU. In this contribution, we introduce a newtwo-parameter gain correction technique, based on both the pulse-height estimate of a fiducial line and the baseline value of the pixels. Using gain functions that simulate ground calibration data, we show that this technique can accurately correct deviations in detector gain due to changes in TES operating conditions such as heat sink temperature, bias voltage, thermal radiation loading and linear amplifier gain. We also address potential optimisations of the onboard calibration source and compare the performance of this new technique with those previously used.

Cucchetti, E.↗

On the Development of Shell Buckling Knockdown Factors for Stiffened Metallic Launch Vehicle Cylinders

From the 1920s to the early 1970s, many shell buckling experiments were conducted in an effort to understand the complex buckling behavior exhibited by thin-walled cylindrical shells, to provide data to correlate with new shell stability theories, and provide design guidelines. Typically, the experiments yielded buckling loads that were substantially lower than the corresponding analytical predictions, which were based on simplified linear bifurcation analyses of geometrically perfect shells with nominal dimensions and idealized boundary conditions. The seminal works by von Kármán and Tsien, by Donnell and Wan, and by Koiter identified small deviations from the idealized geometry of a shell, known as initial geometric imperfections, as a primary source of the discrepancy between corresponding analytical predictions and experimental results. However, the computational tools and capabilities at that time could not perform the nonlinear analyses needed to assess the effects of these imperfections on the buckling behavior of thin-walled shells. Thus, buckling design allowables were determined by establishing lower bounds to test data. Specifically, empirical design factors, that have become known as knockdown factors, were determined and were to be used in conjunction with linear bifurcation analyses for simply supported shells; that is, these empirical factors were used to "knock down" the value of the unconservative simplified analytical prediction. This approach to shell buckling design has proved satisfactory for most design purposes and remains prominent in industry practice, as evidenced by the extensive use of the NASA space vehicle design criteria and recommendations. Unfortunately, the current design guidelines have not been updated since they were first published in the late 1960s and may not be able to take full advantage of modern materials, precision manufacturing processes, and new structural concepts.

Hilburger, Mark W.↗

Collision prediction software for radiotherapy treatments

Purpose: This work presents a method of collision predictions for external beam radiotherapy using surface imaging. The present methodology focuses on collision prediction during treatment simulation to evaluate the clearance of a patient’s treatment position and allow for its modification if necessary. Methods: A Kinect camera (Microsoft, Redmond, WA) is used to scan the patient and immobilization devices in the treatment position at the simulator. The surface is reconstructed using the SKANECT software (Occipital, Inc., San Francisco, CA). The treatment isocenter is marked using simulated orthogonal lasers projected on the surface scan. The point cloud of this surface is then shifted to isocenter and converted from Cartesian to cylindrical coordinates. A slab models the treatment couch. A cylinder with a radius equal to the normal distance from isocenter to the collimator plate, and a height defined by the collimator diameter is used to estimate collisions. Points within the cylinder clear through a full gantry rotation with the treatment couch at 0° , while points outside of it collide. The angles of collision are reported. This methodology was experimentally verified using a mannequin positioned in an alpha cradle with both arms up. A planning CT scan of the mannequin was performed, two isocenters were marked in PINNACLE, and this information was exported to AlignRT (VisionRT, London, UK)—a surface imaging system for patient positioning. This was used to ensure accurate positioning of the mannequin in the treatment room, when available. Collision calculations were performed for the two treatment isocenters and the results compared to the collisions detected the room. The accuracy of the Kinect-Skanect surface was evaluated by comparing it to the external surface of the planning CT scan. Results: Experimental verification results showed that the predicted angles of collision matched those recorded in the room within 0.5°, in most cases (largest deviation −1.2°). The accuracy study for the Kinect-Skanect surface showed an average discrepancy between the CT external contour and the surface scan of 2.2 mm. Conclusions: This methodology provides fast and reliable collision predictions using surface imaging. The use of the Kinect-Skanect system allows for a comprehensive modeling of the patient topography including all the relevant anatomy and immobilization devices that may lead to collisions. The use of this tool at the treatment simulation stage may allow therapists to evaluate the clearance of a patient’s treatment position and optimize it before the planning CT scan is performed. This can allow for safer treatments for the patients due to better collision predictions and improved clinical workflow by minimizing replanning and resimulations due to unforeseen clearance issues.

60 APPLIED LIFE SCIENCES↗

Investigating the Linear Thermal Expansion of Additively Manufactured Multi-Material Joining between Invar and Steel

This work investigated the linear thermal expansion properties of a multi-material specimen fabricated with Invar M93 and A36 steel. A sequence of tests was performed to investigate the viability of additively manufactured Invar M93 for lowering the coefficient of thermal expansion (CTE) in multi-material part tooling. Invar beads were additively manufactured on a steel base plate using a fiber laser system, and samples were taken from the steel, Invar, and the interface between the two materials. The CTE of the samples was measured between 40 °C and 150 °C using a thermomechanical analyzer, and the elemental composition was studied with energy dispersive X-ray spectroscopy. The CTE of samples taken from the steel and the interface remained comparable to that of A36 steel; however, deviations between the thermal expansion values were prevalent due to element diffusion in and around the heat-affected zone. The CTEs measured from the Invar bead were lower than those from the other sections with the largest and smallest thermal expansion values being 10.40 μm/m-K and 2.09 μm/m-K. In each of the sections, the largest CTE was measured from samples taken from the end of the weld beads. An additional test was performed to measure the aggregate expansion of multi-material tools. Invar beads were welded on an A36 steel plate. The invar was machined, and the sample was heated in an oven from 40 °C and 160 °C. Strain gauges were placed on the surface of the part and were used to analyze how the combined thermal expansions of the invar and steel would affect the thermal expansion on the surface of a tool. There were small deviations between the expansion values measured by gauges placed in different orientations, and the elongation of the sample was greatest along the dimension containing a larger percentage of steel. On average, the expansion of the machined Invar surface was 42% less than the expansion of the steel surface. The results of this work demonstrate that additively manufactured Invar can be utilized to decrease the CTE for multi-material part tooling.

36 MATERIALS SCIENCE↗

Development and evaluation of a prototype tracking system using the treatment couch

Purpose: Tumor motion increases safety margins around the clinical target volume and leads to an increased dose to the surrounding healthy tissue. The authors have developed and evaluated a one-dimensional treatment couch tracking system to counter steer respiratory tumor motion. Three different motion detection sensors with different lag times were evaluated. Methods: The couch tracking system consists of a motion detection sensor, which can be the topometrical system Topos (Cyber Technologies, Germany), the respiratory gating system RPM (Varian Medical Systems) or a laser triangulation system (Micro Epsilon), and the Protura treatment couch (Civco Medical Systems). The control of the treatment couch was implemented in the block diagram environment Simulink (MathWorks). To achieve real time performance, the Simulink models were executed on a real time engine, provided by Real-Time Windows Target (MathWorks). A proportional-integral control system was implemented. The lag time of the couch tracking system using the three different motion detection sensors was measured. The geometrical accuracy of the system was evaluated by measuring the mean absolute deviation from the reference (static position) during motion tracking. This deviation was compared to the mean absolute deviation without tracking and a reduction factor was defined. A hexapod system was moving according to seven respiration patterns previously acquired with the RPM system as well as according to a sin{sup 6} function with two different frequencies (0.33 and 0.17 Hz) and the treatment table compensated the motion. Results: A prototype system for treatment couch tracking of respiratory motion was developed. The laser based tracking system with a small lag time of 57 ms reduced the residual motion by a factor of 11.9 ± 5.5 (mean value ± standard deviation). An increase in delay time from 57 to 130 ms (RPM based system) resulted in a reduction by a factor of 4.7 ± 2.6. The Topos based tracking system with the largest lag time of 300 ms achieved a mean reduction by a factor of 3.4 ± 2.3. The increase in the penumbra of a profile (1 × 1 cm{sup 2}) for a motion of 6 mm was 1.4 mm. With tracking applied there was no increase in the penumbra. Conclusions: Couch tracking with the Protura treatment couch is achievable. To reliably track all possible respiration patterns without prediction filters a short lag time below 100 ms is needed. More scientific work is necessary to extend our prototype to tracking of internal motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sleep, Sleepiness, and Performance Across Three In-Flight Bunk Rest Opportunities

Introduction: Airline pilots are required to take a rest break in a bunk during long-haul flights in an effort to reduce sleepiness during critical phases of flight. It is unclear, however, whether each rest break affords equal opportunity for sleep. We aimed to characterize sleep, sleepiness, and performance outcomes across three in-flight rest breaks during long-haul flights. Methods: Thirty-seven pilots wore actiwatches and completed sleep diaries for approximately two weeks while flying a variety of long-haul routes (n=126 flights). Self-reported in-flight bunk rest (BR) periods were used to set rest intervals and sleep was estimated within these intervals using actigraphy software (wake threshold set to medium). Pilots provided Karolinska Sleepiness Scale ratings (KSS) and performed a 5-minute psychomotor vigilance task (PVT) before landing. A linear mixed-effects model with participant included as a random effect and allowed to vary by intercept was used to assess differences between BR opportunities. Results : The majority (97%, n=122) of bunk rest periods contained sleep (as estimated by actigraphy). The mean (+/- standard deviation) sleep duration for the first, middle, and third BR opportunity was 152.8 (69.7), 149.2 (44.1), 125.2 (44.9) minutes, respectively. There was a significant effect of BR opportunity for sleep duration (F2,54 = 3.747, p=.03) and KSS (F2,44 = 7.869, p=.001). Bonferroni adjusted planned pairwise contrasts revealed that pilots using the third BR obtained significantly less sleep than in the first BR (p=.029). KSS ratings prior to landing were higher for the third BR compared to both the first (p=.001) and middle BR (p=.017). There were no significant differences for PVT speed or lapses (all p>05). Conclusion: These results suggest that the last rest break is associated with shorter sleep, lower alertness, and no differences in performance relative to the other rest breaks. Further analysis is required to determine whether the higher KSS ratings following the third rest break are associated with sleep inertia, or whether other factors may be involved.

sleepiness↗