Search NASA⌕ Search

SEARCH · Search NASA

Results for “Power Grid Operations”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Analytic Challenges to Valuing Energy Storage

Electric grid energy storage value. System-level asset focus for mechanical and electrochemical energy storage. Analysis questions for power system planning, operations, and customer-side solutions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Best Practice for Developing Availability Guarantee Language in Photovoltaic (PV) O&M Agreements.

This document outlines the foundation for developing language that can be utilized in an Equipment Availability Guarantee, typically included in an O&M services agreement between a PV system or plant owner and an O&M services provider, or operator. Many of the current PV O&M service agreement Availability Guarantees are based on contracts used for traditional power generation, which create challenges for owners and operators due to the variable nature of grid-tied photovoltaic generating technologies. This report documents language used in early PV availability guarantees and presents best practices and equations that can be used to more openly communicate how the reliability of the PV system and plant equipment can be expressed in an availability guarantee. This work will improve the bankability of PV systems by providing greater transparency into the equipment reliability state to all parties involved in an O&M services contract.

Klise, Geoffrey Taylor↗

Harnessing the Hydroelectric Potential of Engineered Drops (Final Technical Report)

The potential for low-head hydropower in the engineered drops in both federal and private irrigation system is well known and significant. The environmental and socio/recreational impacts of harnessing this renewable energy resource in man-made conduits are much less, and often insignificant, compared with comparable hydro-electric potential in natural water features on rivers, lakes, and streams. Yet, few new plants have been commissioned in more than two decades. Over the same time period, low head hydro installations in Germany have more than doubled. The challenge is in finding economical ways to harness the hydro-electric potential in the engineered drops, and efficiently deliver the power to the grid. The objectives of Percheron Power, LLC's (Percheron Power) Project were to design, develop, permit, and operate an innovative low-head hydro-electric generation facility on an existing engineered drop of a large irrigation canal system. The hydro-electric generation facility was designed to employ a new type of turbine and technology, called an Archimedes Hydrodynamic Screw (AHS), to harness the existing potential of the engineered drop. The goal was to demonstrate the new lower cost AHS technology system to federal agencies, irrigation districts and other system owners and to support further development of new small hydropower projects at previously marginal low-head sites in the U.S. The objective of this funding opportunity of the Department of Energy Water Power Technologies Office was to reduce the Levelized Cost of Energy (LCOE) for small hydropower to less than ${$}$0.07/kWh (${$}$70/MWh) to be competitive with existing base-load power sources such as coal-powered power plants.

13 HYDRO ENERGY↗

Combined Creep and Fatigue Modeling

Simultaneous consideration of creep and fatigue is of paramount importance to accurately predict component life in many industrial applications. For example, growing penetration of renewable energy onto the grid is forcing many power plants to transition from base-load power generation to more complex operation modes, characterized by a combination of base-load generation and frequent start-up and shut-down cycles. The frequent start-stop of power plants is causing a significant toll in the component life due to fatigue. As such, creep alone is not adequate anymore to predict the component life. Most existing life prediction models consider creep or fatigue independently while neglect their interactions. In this presentation, we talk about some recent efforts at NETL to develop a unified modeling framework where both creep and fatigue can be considered. The creep-fatigue interaction mechanism is studied. High-throughput simulations are performed under various hold stress and hold time, and analytical expressions are fitted for the crack growth rates under creep and/or fatigue conditions demonstrating some applications of this newly developed modeling capability.

advanced alloy development↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Evolutionary Game Dynamics between Distributed Energy Resources and Microgrid Operator: Balancing Act for Power Factor Improvement

This article investigates the intricate dynamics between Distributed Energy Resources (DERs) and the Microgrid Operator (MGO) within a microgrid interconnected with the main grid. Employing an evolutionary game framework, the study scrutinizes the strategic evolution of DERs’ decision-making processes in their interactions with the MGO. Modeled as an evolutionary game, these interactions encapsulate the strategies adopted by DERs, resulting in stable equilibrium strategies over time. Motivated by direct benefits linked to increased active power production, DERs strive to sell all available power, while the MGO focuses on optimizing the microgrid’s overall performance. The study assesses the microgrid’s performance in terms of its power factor, emphasizing the strategic balance DERs must achieve in their active power generation to avoid penalization. This penalization results in decreased individual utility for DERs due to the overall power factor decrease resulting from their prioritization of active power generation. Additionally, the diminished overall power factor implies a decrease in MGO utility. The individual utility of each DER is further influenced by the strategies adopted by other DERs, impacting the penalization factor. Leveraging a modified IEEE 13-node distribution microgrid consisting of three DERs, the study presents case studies encompassing both cooperative and non-cooperative evolutionary game scenarios. These case studies illuminate the intricacies of interactions and the resulting equilibrium outcomes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Toward the Instrumentation and Data Acquisition of a Tidal Turbine in Real Site Conditions

The National Renewable Energy Laboratory manufactured, instrumented, and deployed thermoplastic composite blades and a data acquisition system (NDAQ) on one of Verdant Power’s Gen5d 5 m diameter tidal turbines in New York’s East River. The thermoplastic blades had internal strain gages, and the NDAQ was a stand-alone system for monitoring and recording the strain and angular position of the blades. The turbine with thermoplastic blades operated and produced power successfully for 3 months, contributing energy to the New York City electric grid. The NDAQ hardware, instrumentation, and structure all survived the deployment and were still functional upon retrieval of the system, but no data were collected. Even though the data retrieval was not a success, data acquisition for deployed subsea marine renewable structures is a new undertaking, and it is critical to share lessons learned from national laboratory experiences. The successful deployment of thermoplastic composite blades marks a significant advancement toward improved materials for subsea components, as well as an advancement in recyclable composite materials. This article outlines the methodology and lessons learned for the instrumentation and data acquisition system.

16 TIDAL AND WAVE POWER↗

Operational characteristics of a translation screen grid beam deflection system for a 5-cm Kaufman thruster

Measurements of beam deflection angle with respect to spring positioning power and accelerator impingement current as a function of deflection angle were made on a 5-cm diameter system. Response time measurements on the translational grid beam deflection system showed that the time for the maximum deflection angle analyzed (+16.4 deg to -16.4 deg) could be reduced by a factor of nine by increasing the heating power applied to the positioning spring from 4 to 16 watts. At 14 watts the response time for maximum deflection was about 1 minute.

Lathem, W. C.↗

Solar power satellite system definition study. Volume 1, phase 1: Executive summary

A systems definition study of the solar satellite system (SPS) is presented. The technical feasibility of solar power satellites based on forecasts of technical capability in the various applicable technologies is assessed. The performance, cost, operational characteristics, reliability, and the suitability of SPS's as power generators for typical commercial electricity grids are discussed. The uncertainties inherent in the system characteristics forecasts are assessed.

Source record↗

Sensitivity Testing of the NSTAR Ion Thruster

During the Extended Life Test of the DS1 flight spare ion thruster, the engine was subjected to sensitvity testing in order to characterize the macroscopic dependence of discharge chamber sensitivity to a +\-3% vatiation in main flow, cathode flow and beam current, and to +\5% variation in beam and accelerator voltage, was determined for the minimum- (THO), half- (TH8) and full power (TH15) throttle levels. For each power level investigared, 16 high/low operating conditions were chosen to vary the flows, beam current, and grid voltages in in a matrix that mapped out the entire parameter space. The matrix of data generated was used to determine the partial derivative or senitivity of the dependent parameters--discharge voltage, discharge current, discharge loss, double-to-single-ion current ratio, and neutralizer-keeper voltage--to the variation in the independent parameters--main flow, cathode flow, beam current, and beam voltage. The sensititivities of each dependent parameter with respect to each independent parameter were determined using a least-square fit routine. Variation in these sensitivities with thruster runtime was recorded over the duration of the ELT, to detemine if discharge performance changed with thruster wear. Several key findings have been ascertained from the sensitivity testing. Discharge operation is most sensitve to changes in cathode flow and to a lesser degree main flow. The data also confirms that for the NSTAR configuration plasma production is limited by primary electron input due to the fixed neutral population. Key sensitivities along with their change with thruster wear (operating time) will be presented. In addition double ion content measurements with an ExB probe will also be presented to illustrate beam ion production and content sensitivity to the discharge chamber operating parameteres.

electric propulsion↗

Integration of Renewables Via Demand Management: Highly Dispatchable and Distributed Demand Response for the Integration of Distributed Generation

GENI Project: AutoGrid, in conjunction with Lawrence Berkeley National Laboratory and Columbia University, will design and demonstrate automated control software that helps manage real-time demand for energy across the electric grid. Known as the Demand Response Optimization and Management System - Real-Time (DROMS-RT), the software will enable personalized price signal to be sent to millions of customers in extremely short timeframes—incentivizing them to alter their electricity use in response to grid conditions. This will help grid operators better manage unpredictable demand and supply fluctuations in short time-scales —making the power generation process more efficient and cost effective for both suppliers and consumers. DROMS-RT is expected to provide a 90% reduction in the cost of operating demand response and dynamic pricing Projects in the U.S.

ARPA-E↗

Microgrid Energy Management with Load Clipping DSM and Small Hydro Dispatch

Smart meters deployed in microgrids are starting to enable real-time load aggregation measurements as well as fine-grained monitoring and control, including load clipping to prevent power cuts. This new functionality makes it possible to envision and implement new operating strategies for grid managers. Current grid simulation tools do not allow offline assessment and evaluation of supply dispatch and load clipping strategies, which leaves microgrid operators relying on broad rules of thumb, real-time experimentation, and intuition when implementing load clipping. This research focuses on developing demand side management and dispatch planning options for smart-meter-enabled microgrids, along with tool support to choose between these options.

13 HYDRO ENERGY↗

A Data Quality-Aware Framework to Reliably Forecast Photovoltaic Generation and Consumer Load for an Improved Resilience of Microgrids

Photovoltaic (PV) power and consumer load forecasting plays a critical role to ensure operational resilience of the electric grid. Most data-driven forecasting algorithms rely heavily on the continuous availability of good quality data for periodic training and validation. When deployed at the grid’s edge, prolonged disruptions to communications during extreme events degrade data quality. Factors such as missing observations, epistemic uncertainties, data drift, and concept drift are manifestations of data quality that impact the generalization of such field-deployed forecasting models. Currently, there exists no mechanism in the literature to dynamically switch between models under varying degrees of data quality as quantified by certain metrics for each factor highlighted above. This paper addresses this shortcoming by conceptually introducing a data qualityaware framework for reliable PV generation and consumer load forecasting. The framework’s design incorporates components of missing values, divergence tests, and continuous monitoring of generalization performance to detect changes in data quality caused by communications disruptions and trigger specific classes of forecasting models grouped under three use cases (UC1- UC3). As a first step towards validating this framework, real data collected from an actual field microgrid system is used to demonstrate the viability of the three use cases. Results show that the performance is the best in UC1 with an unadjusted R-square value of 0.954, followed by 0.939 for UC2 and 0.757 for UC3.

Sundararajan, Aditya↗

Learning Local Volt/VAR Controllers Toward Efficient Network Operation with Stability Guarantees: Preprint

This paper considers the problem of voltage regulation in distribution network. The primary motivation is to keep voltages within pre-assigned operating limits by commanding the reactive power output of distributed energy resources (DERs) deployed in the grid. We develop a framework for developing local Volt/Var control that comprises of two main steps. In the first, exploiting historical data and for each DER, we learn a function representing desirable equilibrium points for the power network. These points approximate solutions of an Optimal Power Flow problem. In the second, we propose a control scheme for steering the network towards these favorable configurations. Theoretical conditions are derived to formally guarantee the stability of the developed control scheme and numerical simulations illustrate the effectiveness of the proposed approach.

data-driven control↗

Incorporating Uncertainty of Wind Power Generation Forecast into Power System Operation, Dispatch, and Unit Commitment Procedures

An approach to evaluate the uncertainties of the balancing capacity, ramping capability, and ramp duration requirements is proposed. The approach includes three steps: forecast data acquisition, statistical analysis of retrospective information, and prediction of grid balancing requirements for a specified time horizon and a given confidence level. An assessment of the capacity and ramping requirements is performed using a specially developed probabilistic algorithm based on histogram analysis, incorporating sources of uncertainty - both continuous (wind and load forecast errors) and discrete (forced generator outages and start-up failures). A new method called the 'flying-brick' technique is developed to evaluate the look-ahead required generation performance envelope for the worst case scenario within a user-specified confidence level. A self-validation process is used to validate the accuracy of the confidence intervals. To demonstrate the validity of the developed uncertainty assessment methods and its impact on grid operation, a framework for integrating the proposed methods with an EMS system is developed. Demonstration through EMS integration illustrates the applicability of the proposed methodology and the developed tool for actual grid operation and paves the road for integration with EMS systems in control rooms.

17 WIND ENERGY↗

HydraGNN_OPF_GFM_2026 - Ensemble of predictive graph foundation models for power grid applications

This dataset supports research on graph foundation models for optimal power flow (OPF) on electric grids using HydraGNN. It contains heterogeneous graph representations of PGLib-OPF cases spanning systems from 14 to 13,659 buses, together with packed HDF5 datasets for pretraining, feasibility classification, and N-1 contingency analysis. The release includes OPF solution data, downstream fine-tuning datasets, pretrained HeteroSAGE and HeteroHEAT model checkpoints, hyperparameter-optimization summaries across multiple heterogeneous GNN architectures, and aggregated fine-tuning results for sample-efficiency studies. The dataset is designed to enable scalable training, evaluation, and transfer-learning studies for OPF surrogate modeling, including node-level AC-OPF solution prediction, graph-level prediction, feasibility classification, operating-condition generalization, and contingency-response tasks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Flexibility Reserve Reductions from an Energy Imbalance Market with High Levels of Wind Energy in the Western Interconnection

The anticipated increase in variable generation in the Western Interconnection (WI) over the next several years has raised concerns about how to maintain system balance, especially in smaller Balancing Areas (BAs). Given renewable portfolio standards in the West, it is possible that more than 50 gigawatts (GW) of wind capacity will be installed by 2020. Significant quantities of solar generationare likely to be added as well. The consequent increase in variability and uncertainty that must be managed by the conventional generation fleet and responsive load make it attractive to consider ways in which Balancing Area Authorities (BAAs) can pool their variability and response resources, thus taking advantage of geographic and temporal diversity to increase overall operational efficiency.Our analysis considers several alternative forms of an Energy Imbalance Market (EIM) that have been proposed in the non-market areas of the WI. The proposed EIM includes two changes in operating practices that independently reduce variability and increase access to responsive resources: BAA cooperation and sub-hourly dispatch. As proposed, the EIM does not consider any form of coordinated unitcommitment; however, over time it is possible that BAAs would develop formal or informal coordination plans. This report examines the benefits of several possible EIM implementations, both separately and in concert.

17 WIND ENERGY↗