Search NASA⌕ Search

SEARCH · Search NASA

Results for “Protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Spin-squeezing-induced enhancement of the sensitivity of an atomic clock using coherent population trapping

The coherent population trapping (CPT) effect is used for making compact atomic clocks. There are two types of CPT clocks: the one in which the Raman beams are applied continuously and the one in which two CPT pulses separated by a dark period are applied (Ramsey scheme). It is obvious that the technique of spin squeezing can only be applied to the Ramsey CPT clock to enhance the sensitivity. However, it is not apparent how to adapt to the CPT clock the protocols for the microwave clock using one-axis-twist squeezing (OATS), since the Ramsey CPT clock is not trivially equivalent to the Ramsey microwave clock. In this paper, we show explicitly how to adapt two protocols using OATS, namely, the Schrödinger cat state protocol (SCSP) and the generalization thereof, and the echo squeezing protocol (ESP), to the CPT clock. The ESP magnifies the phase shift by a factor of N / e , while the SCSP magnifies the phase shift by a factor of N / 2 , making it able to achieve a higher sensitivity in the presence of excess noise.

Li, Jinyang↗

Mobile C-arm cone-beam CT for guidance of spine surgery: Image quality, radiation dose, and integration with interventional guidance

Purpose: A flat-panel detector based mobile isocentric C-arm for cone-beam CT (CBCT) has been developed to allow intraoperative 3D imaging with sub-millimeter spatial resolution and soft-tissue visibility. Image quality and radiation dose were evaluated in spinal surgery, commonly relying on lower-performance image intensifier based mobile C-arms. Scan protocols were developed for task-specific imaging at minimum dose, in-room exposure was evaluated, and integration of the imaging system with a surgical guidance system was demonstrated in preclinical studies of minimally invasive spine surgery. Methods: Radiation dose was assessed as a function of kilovolt (peak) (80-120 kVp) and milliampere second using thoracic and lumbar spine dosimetry phantoms. In-room radiation exposure was measured throughout the operating room for various CBCT scan protocols. Image quality was assessed using tissue-equivalent inserts in chest and abdomen phantoms to evaluate bone and soft-tissue contrast-to-noise ratio as a function of dose, and task-specific protocols (i.e., visualization of bone or soft-tissues) were defined. Results were applied in preclinical studies using a cadaveric torso simulating minimally invasive, transpedicular surgery. Results: Task-specific CBCT protocols identified include: thoracic bone visualization (100 kVp; 60 mAs; 1.8 mGy); lumbar bone visualization (100 kVp; 130 mAs; 3.2 mGy); thoracic soft-tissue visualization (100 kVp; 230 mAs; 4.3 mGy); and lumbar soft-tissue visualization (120 kVp; 460 mAs; 10.6 mGy) - each at (0.3 x 0.3 x 0.9 mm{sup 3}) voxel size. Alternative lower-dose, lower-resolution soft-tissue visualization protocols were identified (100 kVp; 230 mAs; 5.1 mGy) for the lumbar region at (0.3 x 0.3 x 1.5 mm{sup 3}) voxel size. Half-scan orbit of the C-arm (x-ray tube traversing under the table) was dosimetrically advantageous (prepatient attenuation) with a nonuniform dose distribution ({approx}2 x higher at the entrance side than at isocenter, and {approx}3-4 lower at the exit side). The in-room dose (microsievert) per unit scan dose (milligray) ranged from {approx}21 {mu}Sv/mGy on average at tableside to {approx}0.1 {mu}Sv/mGy at 2.0 m distance to isocenter. All protocols involve surgical staff stepping behind a shield wall for each CBCT scan, therefore imparting {approx}zero dose to staff. Protocol implementation in preclinical cadaveric studies demonstrate integration of the C-arm with a navigation system for spine surgery guidance-specifically, minimally invasive vertebroplasty in which the system provided accurate guidance and visualization of needle placement and bone cement distribution. Cumulative dose including multiple intraoperative scans was {approx}11.5 mGy for CBCT-guided thoracic vertebroplasty and {approx}23.2 mGy for lumbar vertebroplasty, with dose to staff at tableside reduced to {approx}1 min of fluoroscopy time ({approx}40-60 {mu}Sv), compared to 5-11 min for the conventional approach. Conclusions: Intraoperative CBCT using a high-performance mobile C-arm prototype demonstrates image quality suitable to guidance of spine surgery, with task-specific protocols providing an important basis for minimizing radiation dose, while maintaining image quality sufficient for surgical guidance. Images demonstrate a significant advance in spatial resolution and soft-tissue visibility, and CBCT guidance offers the potential to reduce fluoroscopy reliance, reducing cumulative dose to patient and staff. Integration with a surgical guidance system demonstrates precise tracking and visualization in up-to-date images (alleviating reliance on preoperative images only), including detection of errors or suboptimal surgical outcomes in the operating room.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation into image quality and dose for different patient geometries with multiple cone-beam CT systems

Purpose: To provide quantitative and qualitative image quality metrics and imaging dose for modern Varian On-board Imager (OBI) (ver. 1.5) and Elekta X-ray Volume Imager (XVI) (ver. 4.5R) cone-beam computed tomography (CBCT) systems in a clinical adaptive radiation therapy environment by accounting for varying patient thickness. Methods: Image quality measurements were acquired with Catphan 504 phantom (nominal diameter and with additional 10 cm thickness) for OBI and XVI systems and compared to planning CT (pCT) (GE LightSpeed). Various clinical protocols were analyzed for the OBI and XVI systems and analyzed using image quality metrics, including spatial resolution, low contrast detectability, uniformity, and HU sensitivity. Imaging dose measurements were acquired in Wellhofer Scanditronix i'mRT phantom at nominal phantom diameter and with additional 4 cm phantom diameter using GafChromic XRQA2 film. Calibration curves were generated using previously published in-air Air Kerma calibration method. Results: The OBI system full trajectory scans exhibited very little dependence on phantom thickness for accurate HU calculation, while half-trajectory scans with full-fan filter exhibited dependence of HU calculation on phantom thickness. The contrast-to-noise ratio (CNR) for the OBI scans decreased with additional phantom thickness. The uniformity of Head protocol scan was most significantly affected with additional phantom thickness. The spatial resolution and CNR compared favorably with pCT, while the uniformity of the OBI system was slightly inferior to pCT. The OBI scan protocol dose levels for nominal phantom thickness at the central portion of the phantom were 2.61, 0.72, and 1.88 cGy, and for additional phantom thickness were 1.95, 0.48, and 1.52 cGy, for the Pelvis, Thorax, and Spotlight protocols, respectively. The XVI system scans exhibited dependence on phantom thickness for accurate HU calculation regardless of trajectory. The CNR for the XVI scans decreased with additional phantom thickness. The uniformity of the XVI scans was significantly dependent on the selection of the proper FOV setting for all phantom geometries. The spatial resolution, CNR, and uniformity for XVI were lower than values measured for pCT. The XVI scan protocol dose levels at the central portion of the phantom for nominal phantom thickness were 2.14, 2.15, and 0.33 cGy, and for additional phantom thickness were 1.56, 1.68, and 0.21 cGy, for the Pelvis M20, Chest M20, and Prostate Seed S10 scan protocols, respectively. Conclusions: The OBI system offered comparable spatial resolution and CNR results to the results for pCT. Full trajectory scans with the OBI system need little-to-no correction for HU calculation based on HU stability with changing phantom thickness. The XVI system offered lower spatial resolution and CNR results than pCT. In addition, the HU calculation for all scan protocols was dependent on the phantom thickness. The uniformity for each CBCT system was inferior to that of pCT for each phantom geometry. The dose for each system and scan protocol in the interior of the phantom tended to decrease by approximately 25% with 4 cm additional phantom thickness.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-I-16: Short Breast MRI with High-Resolution T2-Weighted and Dynamic Contrast Enhanced T1-Weighted Images

Purpose: To develop and demonstrate a short breast (sb) MRI protocol that acquires both T2-weighted and dynamic contrast-enhanced T1-weighted images in approximately ten minutes. Methods: The sb-MRI protocol consists of two novel pulse sequences. The first is a flexible fast spin-echo triple-echo Dixon (FTED) sequence for high-resolution fat-suppressed T2-weighted imaging, and the second is a 3D fast dual-echo spoiled gradient sequence (FLEX) for volumetric fat-suppressed T1-weighted imaging before and post contrast agent injection. The flexible FTED sequence replaces each single readout during every echo-spacing period of FSE with three fast-switching bipolar readouts to produce three raw images in a single acquisition. These three raw images are then post-processed using a Dixon algorithm to generate separate water-only and fat-only images. The FLEX sequence acquires two echoes using dual-echo readout after each RF excitation and the corresponding images are post-processed using a similar Dixon algorithm to yield water-only and fat-only images. The sb-MRI protocol was implemented on a 3T MRI scanner and used for patients who had undergone concurrent clinical MRI for breast cancer screening. Results: With the same scan parameters (eg, spatial coverage, field of view, spatial and temporal resolution) as the clinical protocol, the total scan-time of the sb-MRI protocol (including the localizer, bilateral T2-weighted, and dynamic contrast-enhanced T1-weighted images) was 11 minutes. In comparison, the clinical breast MRI protocol took 43 minutes. Uniform fat suppression and high image quality were consistently achieved by sb-MRI. Conclusion: We demonstrated a sb-MRI protocol comprising both T2-weighted and dynamic contrast-enhanced T1-weighted images can be performed in approximately ten minutes. The spatial and temporal resolution of the images easily satisfies the current breast MRI accreditation guidelines by the American College of Radiology. The protocol has the potential of making breast MRI more widely accessible to and more tolerable by the patients. JMA is the inventor of United States patents that are owned by the University of Texas Board of Regents and currently licensed to GE Healthcare and Siemens Gmbh.

60 APPLIED LIFE SCIENCES↗

Composite Sampling of a Bacillus anthracis Surrogate with Cellulose Sponge Surface Samplers from a Nonporous Surface

A series of experiments was conducted to explore the utility of composite-based collection of surface samples for the detection of a Bacillus anthracis surrogate using cellulose sponge samplers on a nonporous stainless steel surface. Two composite-based collection approaches were evaluated over a surface area of 3716 cm 2 (four separate 929 cm 2 areas), larger than the 645 cm 2 prescribed by the standard Centers for Disease Control (CDC) and Prevention cellulose sponge sampling protocol for use on nonporous surfaces. The CDC method was also compared to a modified protocol where only one surface of the sponge sampler was used for each of the four areas composited. Differences in collection efficiency compared to positive controls and the potential for contaminant transfer for each protocol were assessed. The impact of the loss of wetting buffer from the sponge sampler onto additional surface areas sampled was evaluated. Statistical tests of the results using ANOVA indicate that the collection of composite samples using the modified sampling protocol is comparable to the collection of composite samples using the standard CDC protocol (p = 0.261). Most of the surface-bound spores are collected on the first sampling pass, suggesting that multiple passes with the sponge sampler over the same surface may be unnecessary. The effect of moisture loss from the sponge sampler on collection efficiency was not significant (p = 0.720) for both methods. Contaminant transfer occurs with both sampling protocols, but the magnitude of transfer is significantly greater when using the standard protocol than when the modified protocol is used (p<0.001). The results of this study suggest that composite surface sampling, by either method presented here, could successfully be used to increase the surface area sampled per sponge sampler, resulting in reduced sampling times in the field and decreased laboratory processing cost and turn-around times.

59 BASIC BIOLOGICAL SCIENCES↗

Review of Quantitative Monitoring Methodologies for Emissions Verification and Accounting for Carbon Dioxide Capture and Storage for California’s Greenhouse Gas Cap-and-Trade and Low-Carbon Fuel Standard Programs

The Cap-and-Trade and Low Carbon Fuel Standard (LCFS) programs being administered by the California Air Resources Board (CARB) include Carbon Dioxide Capture and Storage (CCS) as a potential means to reduce greenhouse gas (GHG) emissions. However, there is currently no universal standard approach that quantifies GHG emissions reductions for CCS and that is suitable for the quantitative needs of the Cap-and-Trade and LCFS programs. CCS involves emissions related to the capture (e.g., arising from increased energy needed to separate carbon dioxide (CO 2 ) from a flue gas and compress it for transport), transport (e.g., by pipeline), and storage of CO 2 (e.g., due to leakage to the atmosphere from geologic CO 2 storage sites). In this project, we reviewed and compared monitoring, verification, and accounting (MVA) protocols for CCS from around the world by focusing on protocols specific to the geologic storage part of CCS. In addition to presenting the review of these protocols, we highlight in this report those storage-related MVA protocols that we believe are particularly appropriate for CCS in California. We find that none of the existing protocols is completely appropriate for California, but various elements of all of them could be adopted and/or augmented to develop a rigorous, defensible, and practical surface leakage MVA protocol for California. The key features of a suitable surface leakage MVA plan for California are that it: (1) informs and validates the leakage risk assessment, (2) specifies use of the most effective monitoring strategies while still being flexible enough to accommodate special or site-specific conditions, (3) quantifies stored CO 2 , and (4) offers defensible estimates of uncertainty in monitored properties. California’s surface leakage MVA protocol needs to be applicable to the main CO 2 storage opportunities (in California and in other states with entities participating in California’s Cap-and-Trade or LCFS programs), specifically CO 2 -enhanced oil recovery (CO 2 -EOR), CO 2 injection into depleted gas reservoirs (with or without CO 2 -enhanced gas recovery (CO 2 -EGR)), as well as deep saline storage. Regarding the elements of an effective surface leakage MVA protocol, our recommendations for California are that: (1) both CO 2 and methane (CH 4 ) surface leakage should be monitored, especially for enhanced recovery scenarios, (2) emissions from all sources not directly related to injection and geologic storage (e.g., from capture, or pipeline transport) should be monitored and reported under a plan separate from the surface leakage MVA plan that is included as another component of the quantification methodology (QM), (3) the primary objective of the surface leakage MVA plan should be to quantify surface leakage of CO 2 and CH 4 and its uncertainty, with consideration of best-practices and state-of-the-art approaches to monitoring including attribution assessment, (4) effort should be made to monitor CO 2 storage and migration in the subsurface to anticipate future surface leakage monitoring needs, (5) detailed descriptions of specific monitoring technologies and approaches should be provided in the MVA plan, (6) the main purpose of the CO 2 injection project (CO 2 -EOR, CO 2 -EGR, or pure geologic carbon sequestration (GCS)) needs to be stated up front, (7) approaches to dealing with missing data and quantifying uncertainty need to be described, and (8) post-injection monitoring should go on for a period consistent with or longer than that prescribed by the U.S. EPA.

54 ENVIRONMENTAL SCIENCES↗

Mercury Continuous Emmission Monitor Calibration

Mercury continuous emissions monitoring systems (CEMs) are being implemented in over 800 coal-fired power plant stacks throughput the U.S. Western Research Institute (WRI) is working closely with the Electric Power Research Institute (EPRI), the National Institute of Standards and Technology (NIST), and the Environmental Protection Agency (EPA) to facilitate the development of the experimental criteria for a NIST traceability protocol for dynamic elemental mercury vapor calibrators/generators. These devices are used to calibrate mercury CEMs at power plant sites. The Clean Air Mercury Rule (CAMR) which was published in the Federal Register on May 18, 2005 and vacated by a Federal appeals court in early 2008 required that calibration be performed with NIST-traceable standards. Despite the vacature, mercury emissions regulations in the future will require NIST traceable calibration standards, and EPA does not want to interrupt the effort towards developing NIST traceability protocols. The traceability procedures will be defined by EPA. An initial draft traceability protocol was issued by EPA in May 2007 for comment. In August 2007, EPA issued a conceptual interim traceability protocol for elemental mercury calibrators. The protocol is based on the actual analysis of the output of each calibration unit at several concentration levels ranging initially from about 2-40 {micro}g/m{sup 3} elemental mercury, and in the future down to 0.2 {micro}g/m{sup 3}, and this analysis will be directly traceable to analyses by NIST. The EPA traceability protocol document is divided into two separate sections. The first deals with the qualification of calibrator models by the vendors for use in mercury CEM calibration. The second describes the procedure that the vendors must use to certify the calibrators that meet the qualification specifications. The NIST traceable certification is performance based, traceable to analysis using isotope dilution inductively coupled plasma/mass spectrometry (ID/ICP/MS) performed by NIST in Gaithersburg, MD. The outputs of mercury calibrators are compared to one another using a nesting procedure which allows direct comparison of one calibrator with another at specific concentrations and eliminates analyzer variability effects. The qualification portion of the EPA interim traceability protocol requires the vendors to define calibrator performance as affected by variables such as pressure, temperature, line voltage, and shipping. In 2007 WRI developed and conducted a series of simplified qualification experiments to determine actual calibrator performance related to the variables defined in the qualification portion of the interim protocol.

01 COAL, LIGNITE, AND PEAT↗

Sensitive Quantitative Assessment of Balance Disorders

Computerized dynamic posturography (CDP) has become a standard technique for objectively quantifying balance control performance, diagnosing the nature of functional impairments underlying balance disorders, and monitoring clinical treatment outcomes. We have long used CDP protocols to assess recovery of sensory-motor function in astronauts following space flight. The most reliable indicators of post-flight crew performance are the sensory organization tests (SOTs), particularly SOTs 5 and 6, which are sensitive to changes in availability and/or utilization of vestibular cues. We have noted, however, that some astronauts exhibiting obvious signs of balance impairment after flight are able to score within clinical norms on these tests, perhaps as a result of adopting competitive strategies or by their natural skills at substituting alternate sensory information sources. This insensitivity of the CDP protocol could underestimate of the degree of impairment and, perhaps, lead to premature release of those crewmembers to normal duties. To improve the sensitivity of the CDP protocol we have introduced static and dynamic head tilt SOT trials into our protocol. The pattern of postflight recovery quantified by the enhanced CDP protocol appears to more aptly track the re-integration of sensory-motor function, with recovery time increasing as the complexity of sensory-motor/biomechanical task increases. The new CDP protocol therefore seems more suitable for monitoring post-flight sensory-motor recovery and for indicating to crewmembers and flight surgeons fitness for return to duty and/or activities of daily living. There may be classes of patients (e.g., athletes, pilots) having motivation and/or performance characteristics similar to astronauts whose sensory-motor treatment outcomes would also be more accurately monitored using the enhanced CDP protocol. Furthermore, the enhanced protocol may be useful in early detection of age-related balance disorders.

Paloski, Willilam H.↗

Mission Operations Center (MOC) - Precipitation Processing System (PPS) Interface Software System (MPISS)

MPISS is an automatic file transfer system that implements a combination of standard and mission-unique transfer protocols required by the Global Precipitation Measurement Mission (GPM) Precipitation Processing System (PPS) to control the flow of data between the MOC and the PPS. The primary features of MPISS are file transfers (both with and without PPS specific protocols), logging of file transfer and system events to local files and a standard messaging bus, short term storage of data files to facilitate retransmissions, and generation of file transfer accounting reports. The system includes a graphical user interface (GUI) to control the system, allow manual operations, and to display events in real time. The PPS specific protocols are an enhanced version of those that were developed for the Tropical Rainfall Measuring Mission (TRMM). All file transfers between the MOC and the PPS use the SSH File Transfer Protocol (SFTP). For reports and data files generated within the MOC, no additional protocols are used when transferring files to the PPS. For observatory data files, an additional handshaking protocol of data notices and data receipts is used. MPISS generates and sends to the PPS data notices containing data start and stop times along with a checksum for the file for each observatory data file transmitted. MPISS retrieves the PPS generated data receipts that indicate the success or failure of the PPS to ingest the data file and/or notice. MPISS retransmits the appropriate files as indicated in the receipt when required. MPISS also automatically retrieves files from the PPS. The unique feature of this software is the use of both standard and PPS specific protocols in parallel. The advantage of this capability is that it supports users that require the PPS protocol as well as those that do not require it. The system is highly configurable to accommodate the needs of future users.

Ferrara, Jeffrey↗

Impact of Cyber Threat Awareness on Driver Response to an Unexpected Vehicle Cyberattack

Here, the integration of advanced cyber-physical systems in heavy vehicles introduces new vulnerabilities by expanding the possibility of cyberattacks. The objective of this study is to evaluate (1) how threat awareness influences driver response to an unexpected cyberattack, (2) how the provision of a basic cyberattack response protocol influences driver performance, and (3) how professionally trained versus standard drivers compare in their responses to a cyberattack. An on-road driving study (N = 50) was conducted using a medium heavy-duty vehicle. Participants were divided into three groups: Control, which remained unaware of any potential cyberattack; Aware, which was informed about the potential cyberattack; and Aware + Protocol, which received the same warning as the Aware group with the addition of a basic cyberattack response protocol. An instrument cluster cyberattack was executed at the same location for all participants. The findings highlight the essential role of awareness and response protocol in enhancing driver response to an unexpected vehicle cyberattack. The Aware + Protocol group had the highest stop rate (100%) and the shortest stopping distances (224 m for standard drivers and 254 m for professionals), compared to the Control group (828 and 520 m, respectively). Aware + Protocol also had the fastest reaction time, averaging 7.53 s, versus 16.12 s (Aware) and 30.29 s (Control). These results emphasize that awareness alone is insufficient. Providing drivers with clear, actionable protocols significantly improves their ability to react quickly and safely to cyberattacks, enhancing overall road safety.

Cybersecurity↗

Fast myocardial perfusion imaging with {sup 99m}Tc in challenging patients using conventional SPECT cameras

Background: We attempted to validate the performance of a fast myocardial perfusion imaging (MPI) protocol in diagnostically challenging patients. Methods: 78 patients with ΒΜΙ > 24.9, LVH or three vessels disease underwent two sequential gated-MPI studies. The first at 15 (Early Imaging, EI) and the second at 45 (Late Imaging, LI) minutes post {sup 99m}Tc-injection, at both stress and rest. Counts over heart (H), liver (Liv) and subdiaphragmatic space (Sub) and image quality, and myocardial perfusion and function parameters were compared between the two protocols. Coronary angiography was performed within 2 months from MPI, and ROC analysis was used to compare the diagnostic accuracy for the detection of ≥50% diameter luminal stenosis. Results: Quality was optimal-good in 93% of EI and 98% of LI studies (P = .12), H/Liv and stress H/Sub ratios were similar, but rest H/Sub ratio was lower in EI (P = .009). SSS [10 (0 to 46) vs 9 (0 to 36), P = .006] and SDS [3 (0 to 35) vs 2 (0 to 34), P = .02] were higher in EI protocol. LVEF, motion and thickening scores did not differ between the two protocols. A highly significant (P < .001) linear relationship with clinically negligible mean differences in Bland-Altman analysis was observed for all perfusion and function-related data. Sensitivity (EI 81%, LI 80%) and specificity (65% for both) did not differ (P = .23) between the two protocols. Conclusion: The fast protocol is technically feasible and diagnostically accurate compared to the established protocol in diagnostically challenging patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhancing robustness of multiparty quantum correlations using weak measurement

Multipartite quantum correlations are important resources for the development of quantum information and computation protocols. However, the resourcefulness of multipartite quantum correlations in practical settings is limited by its fragility under decoherence due to environmental interactions. Though there exist protocols to protect bipartite entanglement under decoherence, the implementation of such protocols for multipartite quantum correlations has not been sufficiently explored. Here, we study the effect of local amplitude damping channel on the generalized Greenberger–Horne–Zeilinger state, and use a protocol of optimal reversal quantum weak measurement to protect the multipartite quantum correlations. We observe that the weak measurement reversal protocol enhances the robustness of multipartite quantum correlations. Further it increases the critical damping value that corresponds to entanglement sudden death. To emphasize the efficacy of the technique in protection of multipartite quantum correlation, we investigate two proximately related quantum communication tasks, namely, quantum teleportation in a one sender, many receivers setting and multiparty quantum information splitting, through a local amplitude damping channel. We observe an increase in the average fidelity of both the quantum communication tasks under the weak measurement reversal protocol. The method may prove beneficial, for combating external interactions, in other quantum information tasks using multipartite resources. - Highlights: • Extension of weak measurement reversal scheme to protect multiparty quantum correlations. • Protection of multiparty quantum correlation under local amplitude damping noise. • Enhanced fidelity of quantum teleportation in one sender and many receivers setting. • Enhanced fidelity of quantum information splitting protocol.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Highly Efficient Training, Refinement, and Validation of a Knowledge-based Planning Quality-Control System for Radiation Therapy Clinical Trials

Purpose: To demonstrate an efficient method for training and validation of a knowledge-based planning (KBP) system as a radiation therapy clinical trial plan quality-control system. Methods and Materials: We analyzed 86 patients with stage IB through IVA cervical cancer treated with intensity modulated radiation therapy at 2 institutions according to the standards of the INTERTECC (International Evaluation of Radiotherapy Technology Effectiveness in Cervical Cancer, National Clinical Trials Network identifier: 01554397) protocol. The protocol used a planning target volume and 2 primary organs at risk: pelvic bone marrow (PBM) and bowel. Secondary organs at risk were rectum and bladder. Initial unfiltered dose-volume histogram (DVH) estimation models were trained using all 86 plans. Refined training sets were created by removing sub-optimal plans from the unfiltered sample, and DVH estimation models… and DVH estimation models were constructed by identifying 30 of 86 plans emphasizing PBM sparing (comparing protocol-specified dosimetric cutpoints V{sub 10} (percentage volume of PBM receiving at least 10 Gy dose) and V{sub 20} (percentage volume of PBM receiving at least 20 Gy dose) with unfiltered predictions) and another 30 of 86 plans emphasizing bowel sparing (comparing V{sub 40} (absolute volume of bowel receiving at least 40 Gy dose) and V{sub 45} (absolute volume of bowel receiving at least 45 Gy dose), 9 in common with the PBM set). To obtain deliverable KBP plans, refined models must inform patient-specific optimization objectives and/or priorities (an auto-planning “routine”). Four candidate routines emphasizing different tradeoffs were composed, and a script was developed to automatically re-plan multiple patients with each routine. After selection of the routine that best met protocol objectives in the 51-patient training sample (KBP{sub FINAL}), protocol-specific DVH metrics and normal tissue complication probability were compared for original versus KBP{sub FINAL} plans across the 35-patient validation set. Paired t tests were used to test differences between planning sets. Results: KBP{sub FINAL} plans outperformed manual planning across the validation set in all protocol-specific DVH cutpoints. The mean normal tissue complication probability for gastrointestinal toxicity was lower for KBP{sub FINAL} versus validation-set plans (48.7% vs 53.8%, P<.001). Similarly, the estimated mean white blood cell count nadir was higher (2.77 vs 2.49 k/mL, P<.001) with KBP{sub FINAL} plans, indicating lowered probability of hematologic toxicity. Conclusions: This work demonstrates that a KBP system can be efficiently trained and refined for use in radiation therapy clinical trials with minimal effort. This patient-specific plan quality control resulted in improvements on protocol-specific dosimetric endpoints.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CHARMM-GUI Input Generator for NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM Simulations Using the CHARMM36 Additive Force Field

Here we report that proper treatment of nonbonded interactions is essential for the accuracy of molecular dynamics (MD) simulations, especially in studies of lipid bilayers. The use of the CHARMM36 force field (C36 FF) in different MD simulation programs can result in disagreements with published simulations performed with CHARMM due to differences in the protocols used to treat the long-range and 1-4 nonbonded interactions. In this study, we systematically test the use of the C36 lipid FF in NAMD, GROMACS, AMBER, OpenMM, and CHARMM/OpenMM. A wide range of Lennard-Jones (LJ) cutoff schemes and integrator algorithms were tested to find the optimal simulation protocol to best match bilayer properties of six lipids with varying acyl chain saturation and head groups. MD simulations of a 1,2-dipalmitoyl-sn-phosphatidylcholine (DPPC) bilayer were used to obtain the optimal protocol for each program. MD simulations with all programs were found to reasonably match the DPPC bilayer properties (surface area per lipid, chain order parameters, and area compressibility modulus) obtained using the standard protocol used in CHARMM as well as from experiments. The optimal simulation protocol was then applied to the other five lipid simulations and resulted in excellent agreement between results from most simulation programs as well as with experimental data. AMBER compared least favorably with the expected membrane properties, which appears to be due to its use of the hard-truncation in the LJ potential versus a force-based switching function used to smooth the LJ potential as it approaches the cutoff distance. The optimal simulation protocol for each program has been implemented in CHARMM-GUI. This protocol is expected to be applicable to the remainder of the additive C36 FF including the proteins, nucleic acids, carbohydrates, and small molecules.

97 MATHEMATICS AND COMPUTING↗

Classically verifiable quantum advantage from a computational Bell test

Existing experimental demonstrations of quantum computational advantage have had the limitation that verifying the correctness of the quantum device requires exponentially costly classical computations. Here we propose and analyse an interactive protocol for demonstrating quantum computational advantage, which is efficiently classically verifiable. Our protocol relies on a class of cryptographic tools called trapdoor claw-free functions. Although this type of function has been applied to quantum advantage protocols before, our protocol employs a surprising connection to Bell’s inequality to avoid the need for a demanding cryptographic property called the adaptive hardcore bit, while maintaining essentially no increase in the quantum circuit complexity and no extra assumptions. Leveraging the relaxed cryptographic requirements of the protocol, we present two trapdoor claw-free function constructions, based on Rabin’s function and the Diffie–Hellman problem, which have not been used in this context before. We also present two independent innovations that improve the efficiency of our implementation and can be applied to other quantum cryptographic protocols. First, we give a scheme to discard so-called garbage bits, removing the need for reversibility in the quantum circuits. Second, we show a natural way of performing postselection that reduces the fidelity needed to demonstrate quantum advantage. Combining these results, we describe a blueprint for implementing our protocol on Rydberg atom-based quantum devices, using hardware-native operations that have already been demonstrated experimentally.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

What is the optimal way to prepare a Bell state using measurement and feedback?

Recent work has shown that the use of quantum feedback can significantly enhance both the speed and success rate of measurement-based remote entanglement generation, but it is generally unknown what feedback protocols are optimal for these tasks. In this work, we consider two common measurements that are capable of projecting into pairwise entangled states, namely half- and full-parity measurements of two qubits, and determine in each case a globally optimal protocol for generation of entanglement. For the half-parity measurement, we rederive a previously described protocol using more general methods and prove that it is globally optimal for several figures of merit, including maximal concurrence or fidelity and minimal time to reach a specified concurrence or fidelity. For the full-parity measurement, we derive a protocol for rapid entanglement generation related to that of (Hill, Ralph, Phys. Rev. A 77, 014305), and then map the dynamics of the concurrence of the state to the Bloch vector length of an effective qubit. This mapping allows us to prove several optimality results for feedback protocols with full-parity measurements. We further show that our full-parity protocol transfers entanglement optimally from one qubit to the other amongst all measurement-based schemes. The methods developed here will be useful for deriving feedback protocols and determining their optimality properties in many other quantum systems subject to measurement and unitary operations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Constant Overhead Entanglement Distillation via Scrambling

High-fidelity quantum entanglement enables key quantum networking capabilities such as secure communication and distributed quantum computing, but long-distance entanglement distribution is limited by noise and loss. Entanglement distillation protocols address this problem by extracting high-fidelity Bell pairs from multiple noisy ones. The primary objective is minimizing the resource overhead: the number of noisy input pairs needed to distill each high-fidelity output pair. While protocols achieving optimal overhead are known in theory, they often require complex decoding operations that make practical implementation challenging. We circumvent this challenge by introducing protocols that use quantum scrambling—the spreading of quantum information under chaotic dynamics—through random Clifford operations. Based on this scrambling mechanism, our protocol maintains asymptotically constant overhead, independent of the desired output error rate $\bar{𝜖}$ , and can be implemented with shallow quantum circuits of depth 𝑂⁡(poly log log⁡ $\bar{𝜖}$ −1 ) and memory 𝑂⁡(poly log⁡ $\bar{𝜖}$ −1 ). Our protocol remains effective even with noisy quantum gates. By incorporating error correction, our protocol achieves state-of-the-art performance: starting with pairs of 10% initial infidelity, we require only seven noisy inputs per output pair to distill a single Bell pair with infidelity $\bar{𝜖}$ =10 −12 , substantially outperforming existing schemes. We demonstrate the utility of our protocols for quantum repeater networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Faster Randomized Dynamical Decoupling

We present a randomized dynamical decoupling (DD) protocol that can substantially improve the performance of any given deterministic DD scheme for suppressing coherent noise by using no more than two additional pulses. Our construction is implemented by probabilistically applying sequences of pulses, which, when combined, effectively eliminate the error terms that scale linearly with the system-environment coupling strength. As a result, we show that a randomized protocol using a few pulses can outperform deterministic DD protocols that require considerably more pulses. Furthermore, we prove that the randomized protocol provides an improvement compared to deterministic DD sequences that aim to reduce the error in the system’s Hilbert space, such as Uhrig DD, which had been previously regarded to be optimal. To rigorously evaluate the performance, we introduce new analytical methods suitable for analyzing higher-order DD protocols that might be of independent interest. Here, we also present numerical simulations confirming the significant advantage of using randomized protocols compared to widely used deterministic protocols.

Quantum algorithms & computation↗