Search NASA⌕ Search

SEARCH · Search NASA

Results for “READOUT SYSTEMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Electrochemical Characterization of Photo-Driven Hole-Scavenging by Cadmium Sulfide Quantum Dot-Nitrogenase Biohybrid Complexes

Light-driven biohybrid systems that couple semiconductor nanocrystals with enzymes offer a promising strategy for solar-to-chemical energy-conserving reduction reactions, yet are often limited by inefficient hole scavenging. Hole scavenging is critical for maintaining charge separation in the light-absorbing electron donor molecule and, thus, for sustaining catalytic turnover, making quantification essential to improving system efficiency. Here, we introduce a photoelectrochemical approach for real-time monitoring of hole scavenging in cadmium sulfide (CdS) quantum dot (QD)-nitrogenase MoFe protein biohybrids that catalyze the reduction of H+ and N2. Using hydroquinone (HQ) as the sacrificial electron donor (SED), oxidation of HQ to benzoquinone (BQ) by photogenerated valence-band holes is coupled to the electrochemical reduction of BQ at an electrode, enabling quantification of the hole-scavenging reaction via chronoamperometry. This approach provides a continuous, real-time readout of charge-transfer dynamics under illumination. Systematic variation of light intensity and donor concentration reveals that hole scavenging scales with photon flux and exhibits a non-linear dependence on SED concentration, with an optimum at intermediate HQ concentrations. These results establish chronoamperometry as a powerful tool for probing photoinduced charge transfer, advancing the quantitative understanding of hole-scavenging in biohybrid systems, and offering a generalizable framework for optimizing solar-driven biocatalysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The sweeper spectrometer for neutron invariant-mass spectroscopy at FRIB

Neutron invariant-mass spectroscopy (NIMS) is a key technique for studying unbound and weakly bound nuclei at the limits of stability. At the Facility for Rare Isotope Beams (FRIB), such measurements are performed using the Sweeper spectrometer, a large-gap, high-rigidity dipole system coupled to the MoNA-LISA neutron detector arrays. To meet the demands imposed by higher beam energies (>130 MeV/u) and the broad cocktail-beam selection available at FRIB, the spectrometer has recently been upgraded to improve particle-identification and detection performance. Upstream of the reaction target, a plastic scintillator with Silicon photomultiplier (SiPM) readout provides the global trigger and time reference, two parallel plate avalanche counters (PPACs) track the trajectories of incoming beam particles, and a silicon PIN detector measures the energy loss, ΔE, for charge (Z) identification. After the Sweeper magnet, the trajectories of the reaction products are tracked by two micro-pattern drift chambers (MPDCs), their charge (Z) is identified by a Frisch-grid ionization chamber (FG-IC), and their mass-to-charge ratio (A/Q) is deduced by time-of-flight measurement using a fast plastic scintillator read out by an array of photomultiplier tubes (PMTs). The detection system also incorporates the Modular Neutron Array (MoNA) for neutron detection and the CAESium-iodide scintillator ARray (CAESAR) for high-efficiency γ-ray measurements to enable full kinematic reconstruction. Performance was evaluated using a cocktail beam around 37 Al accelerated at E ≈ 130 MeV/u during the first FRIB campaign, demonstrating the readiness of the upgraded system for future studies of nuclei at and beyond the neutron drip line.

Particle identification methods↗

Optimal Zeno Dragging for Quantum Control: A Shortcut to Zeno with Action-Based Scheduling Optimization

The quantum Zeno effect asserts that quantum measurements inhibit simultaneous unitary dynamics when the “collapse” events are sufficiently strong and frequent. This applies in the limit of strong continuous measurement or dissipation. It is possible to implement a dissipative control that is known as “Zeno dragging” by dynamically varying the monitored observable, and hence also the eigenstates, which are attractors under Zeno dynamics. This is similar to adiabatic processes, in that the Zeno-dragging fidelity is highest when the rate of eigenstate change is slow compared to the measurement rate. We demonstrate here two theoretical methods for using such dynamics to achieve control of quantum systems. The first, which we shall refer to as “shortcut to Zeno,” is analogous to the shortcuts to adiabaticity (counterdiabatic driving) that are frequently used to accelerate unitary adiabatic evolution. In the second approach, we apply the Chantasri-Dressel-Jordan stochastic action [PRA 88, 042110 (2013)], and demonstrate that the extremal-probability readout paths derived from this are well suited to setting up a Pontryagin-style optimization of the Zeno-dragging schedule. A fundamental contribution of the latter approach is to show that an action suitable for measurement-driven control optimization can be derived quite generally from statistical arguments. Implementing these methods on the Zeno dragging of a qubit, we find that both approaches yield the same solution, namely, that the optimal control is a unitary that matches the motion of the Zeno-monitored eigenstate. We then show that such a solution can be more robust than a unitary-only operation and we comment on solvable generalizations of our qubit example embedded in larger systems. These methods open up new pathways toward systematically developing dynamic control of Zeno subspaces to realize dissipatively stabilized quantum operations. Published by the American Physical Society 2024

Physics↗

Nuclear Science Symposium, 31st and Symposium on Nuclear Power Systems, 16th, Orlando, FL, October 31-November 2, 1984, Proceedings

Topics related to physics instrumentation are discussed, taking into account cryostat and electronic development associated with multidetector spectrometer systems, the influence of materials and counting-rate effects on He-3 neutron spectrometry, a data acquisition system for time-resolved muscle experiments, and a sensitive null detector for precise measurements of integral linearity. Other subjects explored are concerned with space instrumentation, computer applications, detectors, instrumentation for high energy physics, instrumentation for nuclear medicine, environmental monitoring and health physics instrumentation, nuclear safeguards and reactor instrumentation, and a 1984 symposium on nuclear power systems. Attention is given to the application of multiprocessors to scientific problems, a large-scale computer facility for computational aerodynamics, a single-board 32-bit computer for the Fastbus, the integration of detector arrays and readout electronics on a single chip, and three-dimensional Monte Carlo simulation of the electron avalanche in a proportional counter.

Biggerstaff, J. A.↗

Readout and trigger for the AFP detector at ATLAS experiment

AFP, the ATLAS Forward Proton consists of silicon detectors at 205 m and 217 m on each side of ATLAS. In 2016 two detectors in one side were installed. The FEI4 chips are read at 160 Mbps over the optical fibers. The DAQ system uses a FPGA board with Artix chip and a mezzanine card with RCE data processing module based on a Zynq chip with ARM processor running ArchLinux. Finally, in this paper we give an overview of the AFP detector with the commissioning steps taken to integrate with the ATLAS TDAQ. Furthermore first performance results are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A High-Speed, Event-Driven, Active Pixel Sensor Readout for Photon-Counting Microchannel Plate Detectors

Silicon array readouts for microchannel plate intensifiers offer several attractive features. In this class of detector, the electron cloud output of the MCP intensifier is converted to visible light by a phosphor; that light is then fiber-optically coupled to the silicon array. In photon-counting mode, the resulting light splashes on the silicon array are recognized and centroided to fractional pixel accuracy by off-chip electronics. This process can result in very high (MCP-limited) spatial resolution while operating at a modest MCP gain (desirable for dynamic range and long term stability). The principal limitation of intensified CCD systems of this type is their severely limited local dynamic range, as accurate photon counting is achieved only if there are not overlapping event splashes within the frame time of the device. This problem can be ameliorated somewhat by processing events only in pre-selected windows of interest of by using an addressable charge injection device (CID) for the readout array. We are currently pursuing the development of an intriguing alternative readout concept based on using an event-driven CMOS Active Pixel Sensor. APS technology permits the incorporation of discriminator circuitry within each pixel. When coupled with suitable CMOS logic outside the array area, the discriminator circuitry can be used to trigger the readout of small sub-array windows only when and where an event splash has been detected, completely eliminating the local dynamic range problem, while achieving a high global count rate capability and maintaining high spatial resolution. We elaborate on this concept and present our progress toward implementing an event-driven APS readout.

Kimble, Randy A.↗

Evaluation of a semiconductor-based atmospheric radioxenon detection system

A prototype radioxenon detection system for beta–gamma coincidence measurements has been designed using a PIPSBox and a pair of coplanar CdZnTe (CZT) detectors. Coincidence events are identified in real-time using a Field-Programmable Gate Array (FPGA). The measurement of 131m Xe and studies on electron backscatter and memory effect in the PIPSBox have been presented previously; this paper details the measurement of 133/133m Xe, 135 Xe, and background. Here, absolute efficiencies were determined, regions of interest were defined, and Minimum Detectable Concentrations (MDC) for all four radioxenon isotopes were calculated. When neglecting interferences between the radioxenons, the prototype system has an estimated MDC of 0.61 ± 0.15 mBq/m 3 for 133 Xe when using gas processing parameters associated with Xenon International, satisfying the CTBTO requirement for sensitivity of ≤1 mBq/m 3 for 133 Xe. Simulation suggests that by increasing number of CZT detectors used by a factor of 16, the MDCs of the system can be improved by a factor of 2-3. The design shows great promise for future improvement and expansion due to its exceptional energy resolution, high background rejection rate, room temperature operation, minimal memory effect, and simple readout electronics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A fast and large bandwidth superconducting variable coupler

Variable microwave-frequency couplers are highly useful components in classical communication systems and likely will play an important role in quantum communication applications. Conventional semiconductor-based microwave couplers have been used with superconducting quantum circuits, enabling, for example, the in situ measurements of multiple devices via a common readout chain. However, the semiconducting elements are lossy and furthermore dissipate energy when switched, making them unsuitable for cryogenic applications requiring rapid, repeated switching. Superconducting Josephson junction-based couplers can be designed for dissipation-free operation with fast switching and are easily integrated with superconducting quantum circuits. These enable on-chip, quantum-coherent routing of microwave photons, providing an appealing alternative to semiconductor switches. Here, we present and characterize a chip-based broadband microwave variable coupler, tunable over 4-8GHz with over 1.5GHz instantaneous bandwidth, based on the superconducting quantum interference device with two parallel Josephson junctions. The coupler is dissipation-free and features large on-off ratios in excess of 40dB, and the coupling can be changed in about 10ns. The simple design presented here can be readily integrated with superconducting qubit circuits and can be easily generalized to realize a four- or more port device.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ASIC for High Rate 3D Position Sensitive Detectors

We report on the development of an application specific integrated circuit (ASIC) for 3D position sensitive detectors (3D PSD). The ASIC is designed to operate with pixelated wide bandgap sensors like Cadmium-Zinc-Telluride (CZT), Mercuric Iodide (Hgl2) and Thallium Bromide (TIBr). It measures the amplitudes and timings associated with an ionizing event on 128 anodes, the anode grid, and the cathode. Each channel provides low-noise charge amplification, high-order shaping with peaking time adjustable from 250 ns to 12 {micro}s, gain adjustable to 20 mV/fC or 120 mV/fC (for a dynamic range of 3.2 MeV and 530 keV in CZT), amplitude discrimination with 5-bit trimming, and positive and negative peak and timing detections. The readout can be full or sparse, based on a flag and single- or multi-cycle token passing. All channels, triggered channels only, or triggered with neighbors can be read out thus increasing the rate capability of the system to more than 10 kcps. The ASIC dissipates 330 mW which corresponds to about 2.5 mW per channel.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monolayer Graphene Bolometer as a Sensitive Far-IR Detector

In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few micro m(sup 2) of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature approx. 14 K. Recent data on the strength of the electron-phonon coupling are used in the present analysis and the contribution of the readout noise to the Noise Equivalent Power (NEP) is explicitly computed. The readout scheme utilizes Johnson Noise Thermometry (JNT) allowing for Frequency-Domain Multiplexing (FDM) using narrowband filter coupling of the HEBs. In general, the filter bandwidth and the summing amplifier noise have a significant effect on the overall system sensitivity.

noise thermometry↗

On the Speed-up of Wave-like Dark Matter Searches with Entangled Qubits

Qubit-based sensing platforms offer promising new directions for wave-like dark matter searches. Recent proposals demonstrate that entangled qubits can achieve quadratic scaling of the signal in the number of qubits. In this work we expand on these proposals to analyze the bandwidth and scan rate performance of entangled qubit protocols across different error regimes. We find that the phase-based readout of entangled protocols preserves the search bandwidth independent of qubit number, in contrast to power-based detection schemes, thereby achieving a genuine scan-rate advantage. We derive coherence time and error rate requirements for qubit systems to realize this advantage. Applying our analysis to dark photon searches, we find that entangled states of approximately 100 qubits can become competitive with benchmark photon-counting cavity experiments for masses $\gtrsim 30{-}40~μ{\rm eV}$, provided sufficiently low error rates are achieved. The advantage increases at higher masses where cavity volume scaling becomes less favorable.

Bodas, Arushi [Fermilab; Chicago U.] (ORCID:000000↗

Analog Readout and Analysis Software for the Ultra-High Rate Germanium (UHRGe) Project

High-resolution high-purity germanium (HPGe) spectrometers are needed for Safeguards applications such as spent fuel assay and uranium hexafluoride cylinder verification. In addition, these spectrometers would be applicable to other high-rate applications such as non-destructive assay of nuclear materials using nuclear resonance fluorescence. Count-rate limitations of today's HPGe technologies, however, lead to concessions in their use and reduction in their efficacy. Large-volume, very high-rate HPGe spectrometers are needed to enable a new generation of nondestructive assay systems. The Ultra-High Rate Germanium (UHRGe) project is developing HPGe spectrometer systems capable of operating at unprecedented rates, 10 to 100 times those available today. This report documents current status of developments in the analog electronics and analysis software.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Gene Expression Measurement Module (GEMM) - A Fully Automated, Miniaturized Instrument for Measuring Gene Expression in Space

The capability to measure gene expression on board spacecraft opens the door to a large number of high-value experiments on the influence of the space environment on biological systems. For example, measurements of gene expression will help us to understand adaptation of terrestrial life to conditions beyond the planet of origin, identify deleterious effects of the space environment on a wide range of organisms from microbes to humans, develop effective countermeasures against these effects, and determine the metabolic bases of microbial pathogenicity and drug resistance. These and other applications hold significant potential for discoveries in space biology, biotechnology, and medicine. Supported by funding from the NASA Astrobiology Science and Technology Instrument Development Program, we are developing a fully automated, miniaturized, integrated fluidic system for small spacecraft capable of in-situ measurement of expression of several hundreds of microbial genes from multiple samples. The instrument will be capable of (1) lysing cell walls of bacteria sampled from cultures grown in space, (2) extracting and purifying RNA released from cells, (3) hybridizing the RNA on a microarray and (4) providing readout of the microarray signal, all in a single microfluidics cartridge. The device is suitable for deployment on nanosatellite platforms developed by NASA Ames' Small Spacecraft Division. To meet space and other technical constraints imposed by these platforms, a number of technical innovations are being implemented. The integration and end-to-end technological and biological validation of the instrument are carried out using as a model the photosynthetic bacterium Synechococcus elongatus, known for its remarkable metabolic diversity and resilience to adverse conditions. Each step in the measurement process-lysis, nucleic acid extraction, purification, and hybridization to an array-is assessed through comparison of the results obtained using the instrument with those from standard laboratory protocols. Once developed, the system can be used with minor modifications for multiple experiments on different platforms in space, including extension to higher organisms and microbial monitoring. A proposed version of GEMM that is capable of handling both microbial and tissue samples on the International Space Station will be briefly summarized.

Pohorille, Andrew↗

Nanophotonic waveguide chip-to-world beam scanning

A seamless chip-to-world photonic interface enables broad advancements in optical ranging, display, communication, computation and quantum information science. The ideal solution enables two-dimensional scanning of a diffraction-limited beam from anywhere on a photonic integrated circuit to a large number of resolvable spots. Current beam-scanning technologies are limited by a fundamental trade-off: photonic-integrated-circuits with diffractive optics offer scalability but have poor mode quality, whereas inertially limited micromechanical scanners provide high-quality beams but lack scalable integration. Here we report a photonic ski-jump—a nanoscale waveguide monolithically integrated on a piezoelectric cantilever—to overcome these limitations. It passively curls ~90° out-of-plane within a less-than-0.1 mm 2 footprint, emits a submicrometre, broadband diffraction-limited beam, and exhibits kilohertz-rate mechanical resonances with quality factors of over 10,000. Fabricated in a volume complementary metal–oxide–semiconductor (CMOS) foundry, our device enables scalable two-dimensional beam scanning. Driven on-resonance at CMOS-level voltages, it achieves a footprint-adjusted spot rate of 68.6 mega spots s –1 mm–², exceeding state-of-the-art micro-electro-mechanical systems mirrors by more than 50-fold, which is sufficient for one million pixels at 100 Hz from an approximately 1.5 mm diameter footprint. We demonstrate full-colour image and video projection, and single-photon initialization and readout from silicon vacancy centres in diamond. Finally, by demonstrating uniformity across a 64 ski-jump array, we establish a pathway to achieving greater than one gigaspot resolution at kilohertz rates within a sub-5-cm-diameter footprint, creating a seamless optical pipeline between integrated photonic processors and the free-space world.

Displays↗

CMS hadron calorimeter front-end upgrade for SLHC phase I

We present an upgrade plan for the CMS HCAL detector. The HCAL upgrade is required for the increased luminosity (3 * 10E34) of SLHC Phase I which is targeted for 2014. A key aspect of the HCAL upgrade is to add longitudinal segmentation to improve background rejection, energy resolution, and electron isolation at the L1 trigger. The increased segmentation is achieved by replacing the hybrid photodiodes (HPDs) with silicon PMTs (SIPMs). We plan to instrument each fiber of the calorimeter with an SIPM (103,000 total). We will then electrically sum outputs from selected SIPMs to form the longitudinal readout segments. In addition to having more longitudinal information, the upgrade plans include a new custom ADC with matched sensitivity and timing information. The increased data volume requires higher speed transmitters and the additional power dissipation for the readout electronics requires better thermal design, since much of the on-detector infrastructure (front-end electronics crates, cooling pipes, optical fiber plant, etc.) will remain the same. We will report on the preliminary designs for these upgraded systems, along with performance requirements and initial design studies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of high energy muons with sub-20 ps timing resolution using L(Y)SO crystals and SiPM readout

Precise timing capability will be a key aspect of particle detectors at future high energy colliders, as the time information can help in the reconstruction of physics events at the high collision rate expected there. Other than being used in detectors for PET, fast scintillating crystals coupled to compact Silicon Photomultipliers (SiPMs) constitute a versatile system that can be exploited to realize an ad-hoc timing device to be hosted in a larger high energy physics detector. In this paper, we present the timing performance of LYSO:Ce and LSO:Ce codoped 0.4% Ca crystals coupled to SiPMs, as measured with 150 GeV muons at the CERN SPS H2 extraction line. Small crystals, with lengths ranging from 5 mm up to 30 mm and transverse size of 2×2mm 2 or 3×3mm 2 , were exposed to a 150 GeV muon beam. SiPMs from two different companies (Hamamatsu and FBK) were used to detect the light produced in the crystals. The best coincidence time resolution value of (14.5±0.5)ps , corresponding to a single-detector time resolution of about 10 ps, is demonstrated for 5 mm long LSO:Ce,Ca crystals coupled to FBK SiPMs, when time walk corrections are applied.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High-flux ptychographic imaging using the new 55 µm-pixel detector ‘Lambda’ based on the Medipix3 readout chip

The Large Area Medipix-Based Detector Array (Lambda) has been used in a ptychographic imaging experiment on solar-cell nanowires. By using a semi-transparent central stop, the high flux density provided by nano-focusing Kirkpatrick–Baez mirrors can be fully exploited for high-resolution phase reconstructions. Suitable detection systems that are capable of recording high photon count rates with single-photon detection are instrumental for coherent X-ray imaging. The new single-photon-counting pixel detector ‘Lambda’ has been tested in a ptychographic imaging experiment on solar-cell nanowires using Kirkpatrick–Baez-focused 13.8 keV X-rays. Taking advantage of the high count rate of the Lambda and dynamic range expansion by the semi-transparent central stop, a high-dynamic-range diffraction signal covering more than seven orders of magnitude has been recorded, which corresponds to a photon flux density of about 10{sup 5} photons nm{sup −2} s{sup −1} or a flux of ∼10{sup 10} photons s{sup −1} on the sample. By comparison with data taken without the semi-transparent central stop, an increase in resolution by a factor of 3–4 is determined: from about 125 nm to about 38 nm for the nanowire and from about 83 nm to about 21 nm for the illuminating wavefield.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A 0.18 micrometer CMOS Thermopile Readout ASIC Immune to 50 MRAD Total Ionizing Dose (SI) and Single Event Latchup to 174MeV-cm(exp 2)/mg

Radiation hardened by design (RHBD) techniques allow commercial CMOS circuits to operate in high total ionizing dose and particle fluence environments. Our radiation hard multi-channel digitizer (MCD) ASIC (Figure 1) is a versatile analog system on a chip (SoC) fabricated in 180nm CMOS. It provides 18 chopper stabilized amplifier channels, a 16- bit sigma-delta analog-digital converter (SDADC) and an on-chip controller. The MCD was evaluated at Goddard Space Flight Center and Texas A&M University's radiation effects facilities and found to be immune to single event latchup (SEL) and total ionizing dose (TID) at 174 MeV-cm(exp 2)/mg and 50 Mrad (Si) respectively.

radiation hardened by design↗