Search NASA⌕ Search

SEARCH · Search NASA

Results for “RESIDENTIAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Model-Based Investigation of Multi-Fault Interactions and Performance Degradation in Residential Heat Pump Systems

Faults in heat pump systems can significantly degrade performance, reduce efficiency, and accelerate component wear, leading to higher operating costs and maintenance demands. While numerous studies have investigated the impact of individual faults, the interactions between multiple concurrent faults remain insufficiently understood, despite their common occurrence in real-world operation. This study conducts a comprehensive simulation analysis of multiple simultaneous faults in a vapor compression heat pump using a validated heat pump design model (HPDM) tool. Detailed component-level modeling methods are implemented to examine performance sensitivity under combinations of refrigerant flow and heat exchanger faults. The results reveal complex fault interactions that can mask or amplify system deviations, challenging conventional diagnostic approaches. Findings from this work provide meaningful insights for the development of more robust fault detection and diagnosis algorithms, supporting improved reliability and energy efficiency in next-generation heat pump technologies.

Hu, Yifeng [ORNL] (ORCID:0000000242875185)↗

Preliminary Assessment for the Electric Load Shifting Potential of Integrating Thermal Energy Storage with Heat Pumps in Residential Buildings in Texas of United States

The widespread adoption of electric-driven heat pumps for heating and cooling is expected to significantly increase electric demand. Cooling electric demand will result in an increase in peak hours electric loads, placing additional strain on the grid during peak hours. This challenge, combined with the current rapidly increasing demand from data centers, exacerbates the electric demand duck curve problem. Integrating thermal energy storage (TES) with heat pump can shift electric use for heating and cooling from peak to off-peak hours of the electric grid, which can help flatten the daily electric demand profile of a building. This paper presents a novel design that integrates heat pump with TES (HP-TES), which uses phase change materials (PCM). Heat pump charges TES by melting or freezing PCM during off-peak hours when there is no thermal demand from the building. TES is then discharged (i.e., by freezing or melting PCM) during peak hours to provide a more favorable heat source or heat sink for the heat pump to meet the thermal demand of the building with lower electricity use than conventional air-source heat pumps. Computer simulations were developed to predict the performance of HP-TES applied to a typical single-family house in the US. The building-level simulation results were scaled up to preliminarily assess the aggregated impacts of deploying HP-TES across all single-family houses in Texas of the United States, including reduction of peak demand of the electric grid.

Anees, Fady [ORNL]↗

Wind Energy Facilities and Residential Properties: The Effect of Proximity and View on Sales Prices

With wind energy expanding rapidly in the U.S. and abroad, and with an increasing number of communities considering nearby wind power developments, there is a need to empirically investigate community concerns about wind project development. One such concern is that property values may be adversely affected by wind energy facilities, and relatively little existing research exists on the subject. The present research is based on almost 7,500 sales of single-family homes situated within ten miles of 24 existing wind facilities in nine different U.S. states. The conclusions of the study are drawn from four different hedonic pricing models. The model results are consistent in that neither the view of the wind facilities nor the distance of the home to those facilities is found to have a statistically significant effect on home sales prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Wind Energy Facilities and Residential Properties: The Effect of Proximity and View on Sales Prices

With an increasing number of communities considering nearby wind power developments, there is a need to empirically investigate community concerns about wind project development. One such concern is that property values may be adversely affected by wind energy facilities, and relatively little research exists on the subject. The present research investigates roughly 7,500 sales of single-family homes surrounding 24 existing U.S. wind facilities. Across four different hedonic models the results are consistent: neither the view of the wind facilities nor the distance of the home to those facilities is found to have a statistically significant effect on home sales prices.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tracking the Sun: Installed Price Trends for Distributed Photovoltaic Systems in the United States - 2018 Edition

Berkeley Lab’s Tracking the Sun report series is dedicated to summarizing installed prices and other trends among grid-connected, distributed solar photovoltaic (PV) systems in the United States. The present report, the 11th edition in the series, focuses on systems installed through year-end 2017, with preliminary trends for the first half of 2018. As in years past, the primary emphasis is on describing changes in installed prices over time and variation in pricing across projects based on location, project ownership, system design, and other attributes. New to this year, however, is an expanded discussion of other project characteristics in the large underlying data sample. Future editions will include more of such material, beyond the report’s traditional focus on installed pricing. The trends described in this report derive primarily from project-level data reported to state agencies and utilities that administer PV incentive programs, solar renewable energy credit (SREC) registration systems, or interconnection processes. In total, data were collected and cleaned for more than 1.3 million individual PV systems, representing 81% of U.S. residential and non-residential PV systems installed through 2017. The analysis of installed pricing trends is based on a subset of roughly 770,000 systems with available installed price data. Key findings from this year’s report include the following: -Installed Prices Continued to Fall through 2017 and into 2018. National median installed prices in 2017 were $3.7 per watt (W) for residential systems (a $0.2/W or 6% decline from the prior year), $3.1/W for small non-residential systems (a $0.4/W or 11% decline), and $2.2/W (a $0.1/W or 5% decline) for large non-residential systems. Data for the first half of 2018 show an additional drop of $0.1/W for residential and small non-residential systems, and effectively no change for large non-residential systems. These recent trends are generally consistent with the pace of price declines since 2014, and mark a slowing from the years immediately preceding (2009-2013) when prices fell by roughly $1/W per year. -Installed Prices Vary Widely Across Individual Projects. Among residential systems installed in 2017, 20% were priced below $3.0/W (the 20th percentile value) while another 20% were above the 80th percentile at $4.5/W. Non-residential systems also exhibit wide spreads, albeit shifted downward, from $2.4/W to $4.1/W for small non-residential and from $1.8/W to $2.8/W for large non-residential projects. These pricing spreads have persisted over time and are both reflective of the heterogeneity in PV systems and markets, as well as suggestive of the potential for further price declines. -Pronounced Pricing Disparities Exist Across States. State-level median installed prices in 2017 ranged from $2.6/W to $4.5/W for residential systems, from $2.2/W to $4.0/W for small non-residential systems, and from $2.1/W to $2.4/W for large non-residential systems. Three of the largest state markets (California, Massachusetts, and New York) are relatively high-priced, pulling overall U.S. median prices upward. These cross-state pricing differences reflect both idiosyncratic features of particular states as well as more-fundamental differences related to market and policy conditions. -Installed Pricing Variation Also Reflects Differences in System Design, Installer, and Customer Characteristics (among other factors). Significant pricing differences were also observed across system sizes within each customer segment (with median prices ranging from $3.2/W to $4.5/W across residential systems of varying size, and from $2.1/W to $3.7/W across non-residential systems), between third-party owned (TPO) and host-owned residential systems ($3.3/W vs. $3.8/W), across residential installers ($2.1/W to $9.6/W for host-owned systems and $1.1/W to $5.1/W for TPO systems), between residential new construction and retrofit systems in California ($2.3/W vs. $3.9/W), between large non-residential systems at commercial sites and tax-exempt customer sites ($2.1/W vs. $2.6/W), and between systems with standard vs. premium efficiency modules ($3.6/W vs. $4.2/W among residential systems). A public version of the underlying dataset can be downloaded at https://emp.lbl.gov/tracking-the-sun.

14 SOLAR ENERGY↗

Building Energy Modeling Enhancements to Identify Least-Cost Pathways to Net-Zero Carbon Homes: Preprint

Residential grid-interactive efficient buildings (GEBs) can utilize high levels of energy efficiency and demand flexibility to deliver value to occupants, the grid, and society. However, without the ability to analyze, design, and optimize residential GEBs there is a risk that homes will not realize their full potential value as efficient and dynamic resources, which could ultimately lead to higher than necessary energy costs for U.S. households and lower realization of potential energy efficiency and demand flexibility benefits such as increased convenience/automation, thermal comfort, durability, indoor air quality, and resilience. In 2018, the National Renewable Energy Laboratory (NREL) Residential Modeling Team developed a vision for an open source Residential GEB Analytics Platform built within DOE's EnergyPlus and OpenStudio modeling environment that would enable the design and optimization of residential GEBs, including the identification of least-cost pathways to highly energy-efficient and energy-flexible homes (e.g., net zero carbon homes). We created a detailed workplan for the development of new and enhanced residential GEB component-level models for EnergyPlus and OpenStudio needed to progress toward the vision for the analytics platform while delivering near-term benefits to industry. This paper 1) presents the vision for the platform, summarizing the workplan for residential GEB modeling enhancements; 2) highlights significant advancements that have been achieved between 2018 and 2022, including stochastic residential occupancy modeling, flexible water heater modeling, detailed lithium-ion stationary battery modeling, and realistic residential HVAC modeling; and 3) outlines ongoing efforts and next steps toward the full vision for the platform.

building energy modeling↗

Quantifying Resolution Implications for Agent-based Distributed Energy Resource Customer Adoption Models

In this report we explore tradeoffs of top-down and bottom-up methods in their precision and computational burden using NREL's dGen model, an agent-based model of residential and non-residential distributed PV adoption. In particular, we assess the role of agent resolution in instantiating statistically-representative populations in the model--and the resulting variance of model projections at the state, sector and county levels. Running the model for a single state with fixed macroeconomic assumptions, we vary both the number of agents instantiated and the number of unique simulations. Notably, in each run we introduce sources of uncertainty in cumulative DPV adoption results during agent instantiation as we stochastically sample agent attributes from localized building characteristic and solar resource distributions. We find three key trends which guide what can be expected of results. First, precision of the model projections, as measured by the variance of the unique simulations increased as a function of the number of agents sampled, though with diminishing returns to scale. The result is expected given the Law of Large Numbers. Second, the mean or expected value of projections decreased as the number of agents instantiated increased. Empirically, aggregate DPV capacities projected by dGen are 7% lower on average at a 10-agent resolution compared to 1-agent resolutions, and up to 10% lower in the non-residential sector. We attribute this outcome to a system sizing scheme that biases lower cumulative installed capacity as agent resolution increases when roof size and load are not positively correlated. Finally, the variance of model projections differed by sector, where variance was substantially larger in the commercial sector, largely due to differences in parameterization by sector. We explain the larger variance in the non-residential sector as an outcome of the greater variance in building uses and load shapes as compared to the residential sector, and we find that a resolution on the order of 100-agents per county would be necessary to bring non-residential variance in line with residential variance at a 2-agent resolution. We propose that further research explore increasing precision and agent resolution in the non-residential sector. Moreover, given that days of intensive computing may be required to resolve a suitable estimate even at the extent of a single state within acceptable levels of precision, to promote computational efficiency we also suggest more clearly quantifying sources of variability at the county level such that resolution can by dynamically increased where county level results are least precise.

14 SOLAR ENERGY↗

Do PEV Drivers Park Near Publicly Accessible EVSE in San Diego but Not Use Them?

The PEV charging stations deployed as part of The EV Project included both residential and non-residential sites. Non-residential sites included EVSE installed in workplace environments, fleet applications and those that were publicly accessible near retail centers, parking lots, and similar locations. The EV Project utilized its Micro-Climate® planning process to determine potential sites for publicly accessible EVSE in San Diego. This process worked with local stakeholders to target EVSE deployment near areas where significant PEV traffic and parking was expected. This planning process is described in The Micro-Climate deployment Process in San Diego1. The EV Project issued its deployment plan for San Diego in November 2010, prior to the sale of PEVs by Nissan and Chevrolet. The Project deployed residential EVSE concurrent with vehicle delivery starting in December 2010. The installation of non-residential EVSE commenced in April 2011 consistent with the original Project schedule, closely following the adoption of PEVs. The residential participation portion of The EV Project was fully subscribed by January 2013 and the non-residential EVSE deployment was essentially completed by August 2013.

33 ADVANCED PROPULSION SYSTEMS↗

Sighten Final Technical Report DEEE0006690 Deploying an integrated and comprehensive solar financing software platform

Over the project, Sighten built a comprehensive software-as-a-service (Saas) platform to automate and streamline the residential solar financing workflow. Before the project period, significant time and money was spent by companies on front-end tools related to system design and proposal creation, but comparatively few resources were available to support the many back-end calculations and data management processes that underpin third party financing. Without a tool like Sighten, the solar financing processes involved passing information from the homeowner prospect into separate tools for system design, financing, and then later to reporting tools including Microsoft Excel, CRM software, in-house software, outside software, and offline, manual processes. Passing data between tools and attempting to connect disparate systems results in inefficiency and inaccuracy for the industry. Sighten was built to consolidate all financial and solar-related calculations in a single software platform. It significantly improves upon the accuracy of these calculations and exposes sophisticated new analysis tools resulting in a rigorous, efficient and cost-effective toolset for scaling residential solar. Widely deploying a platform like Sighten’s significantly and immediately impacts the residential solar space in several important ways: 1) standardizing and improving the quality of all quantitative calculations involved in the residential financing process, most notably project finance, system production and reporting calculations; 2) representing a true step change in terms of reporting and analysis capabilities by maintaining more accurate data and exposing sophisticated tools around simulation, tranching, and financial reporting, among others, to all stakeholders in the space; 3) allowing a broader group of developers/installers/finance companies to access the capital markets by providing an out-of-the-box toolset that handles the execution of running investor capital through a rooftop solar financing program. Standardizing and improving all calculations, improving data quality, and exposing new analysis tools previously unavailable affects investment in the residential space in several important ways: 1) lowering the cost of capital for existing capital providers by mitigating uncertainty and de-risking the solar asset class; 2) attracting new, lower cost investors to the solar asset class as reporting and data quality resemble standards of more mature asset classes; 3) increasing the prevalence of liquidity options for investors through back leverage, securitization, or secondary sale by providing the tools necessary for lenders, ratings agencies, etc. to properly understand a portfolio of residential solar assets. During the project period, Sighten successfully built and scaled a commercially ready tool for the residential solar market. The software solution built by Sighten has been deployed with key target customer segments identified in the award deliverables: solar installers, solar developers/channel managers, and solar financiers, including lenders. Each of these segments greatly benefits from the availability of the Sighten toolset.

14 SOLAR ENERGY↗

Next Generation Integrated PV Products Cost and Workflow Analysis (Final Report)

Residential photovoltaic (PV) costs have fallen consistently for over a decade (Ardani et al. 2018). DOE has subsequently developed a new residential PV cost target for 2030 of $0.05/kilowatt hour (SETO 2023). Ardani et al. (2018) conclude that integrated roofing and PV (RIPV) products may be key to achieving the residential target for both new construction and retrofit residential PV. In RIPV, the PV product is incorporated into or replaces the roofing material. RIPV systems can use conventional crystalline or thin-film technologies, may be aesthetically attractive alternatives to traditional racked and mounted PV systems, and may increase building property values (Cook et al. 2023). These products also have the potential to provide customer acquisition, labor, and equipment cost savings over traditional, racked and mounted residential rooftop PV and several companies have recently introduced integrated roofing and PV (RIPV) products (Cook et al. 2023). In 2022, Tesla was the market leader, representing 94% of RIPV capacity installed in 2022 through its Solar Roof offering, while GAF Energy and its Timberline Solar product was second capturing 3% (Feldman et al. 2023). In this project, NREL analyzed three research questions: (1) How do current RIPV products compare to racked and mounted PV in terms of costs, install times and processes? (2) How are RIPV products installed and are there opportunities for cost savings? (3) What are the key barriers to expanding market opportunities for integrating solar and roofing products? In this project, we explored residential RIPV cost reduction opportunities by analyzing installation processes. Our study documented residential RIPV installations at two reroofing sites (20.52 kilowatts) and the equivalent of nine new construction sites (71.75 kW) in California through a methodology known as time and motion study. We also conducted 15 interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration.

14 SOLAR ENERGY↗

A Safe Response to Renewable Energy Hazards

The International Association of Fire Fighters (IAFF) and Underwriters Laboratories, LLC (UL) in conjunction with UL Solutions initiated a joint project in 2022 under an agreement with the United States Department of Energy-Office of Energy Efficiency and Renewable Energy (DOE-EERE). This project focused on two separate and important initiatives related to energy efficiency in residential buildings. Initiative 1: Fire Performance on Energy Efficient Exterior Walls. Initiative 2: Firefighting Tactics in Residential Properties with Building Energy Storage Systems (BESS). The project’s first initiative addresses concerns surrounding new technologies with enhanced, energy-efficient exterior walls installed on residential properties. The concerns of fire rapidly traveling vertically up the exterior of these walls were examined. This addressed a growing concern from the first responder community that many times, the fires on the exterior of residential buildings have already evolved into an attic fire by the time of arrival – making it problematic to address the fire scenario. The test plan for Initiative 1 incorporated a modified version of an American Society for Testing and Materials (ASTM) test method, ASTM E2707, Standard Test Method for Determining Fire Penetration of Exterior Wall Assemblies Using a Direct Flame Impingement Exposure, as the foundation of the research. The test method involved a wall structure intended to represent retrofit construction to evaluate how fire would spread vertically or laterally. The second aspect of the UL-IAFF Project focuses on the fire service response to Residential Battery Energy Storage System (RBESS) incidents. These simulation tests were constructed in the large-scale fire test facility at UL Solutions’ Northbrook, IL campus. A baseline test was conducted that involved a test structure with no batteries—shelving units populated with standardized commodities, representing a typical garage with cellulosic and plastic contents. Three additional tests have been conducted to generate data with the contribution of energy storage system (ESS) batteries to compare fire and explosion hazards against the baseline test. Through this work, fire service tactical considerations can be explored. From the data, the team can determine 1) the visual indicators of a residential fire that has involved an RBESS (or, potentially, other large batteries) and 2) the impact of fire service-initiated ventilation of the structure on the fire conditions and explosion risks.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characteristics of particulate carbon emissions from real-world Chinese coal combustion

Particulate matter emissions from a series of different Chinese coal combustion systems were collected and analyzed for elemental and organic carbon (EC, OC), and molecular markers. Emissions from both industrial boilers and residential stoves were investigated. The coal used in this study included anthracite, bituminite, and brown coal, as well as commonly used coal briquettes produced in China for residential coal combustion. Results show significant differences in the contribution of carbonaceous species to particulate mass emissions. Industrial boilers had much higher burn out of carbon yielding particulate matter emissions with much lower levels of OC, EC, and speciated organic compounds, while residential stoves had significantly higher emissions of carbonaceous particulate matter with emission rates of approximately 100 times higher than that of industrial boilers. Quantified organic compounds emitted from industrial boilers were dominated by oxygenated compounds, of which 46-68% were organic acids, whereas the dominate species quantified in the emissions from residential stoves were PAHs (38%) and n-alkanes (20%). An important observation was the fact that emission factors of PAHs and the distribution of hopanoids were different among the emissions from industrial and residential coal combustion even using the same coal for combustion. Although particulate matter emissions from industrial and residential combustion were different in many regards, picene was detected in all samples with detectable OC mass concentrations, which supports the use of this organic tracer for OC from all types of coal combustion. 17{alpha}(H),21{beta}(H)-29-norhopane was the predominant hopanoid in coal combustion emissions, which is different from mobile source emissions and may be used to distinguish emissions from these different fossil fuel sources. 32 refs., 4 figs., 1 tab.

01 COAL, LIGNITE, AND PEAT↗

The Impact of Behind-the-Meter Heterogeneous Distributed Energy Resources on Distribution Grids

The increasing integration of distributed energy resources (DERs) on the electric grid brings new challenges and opportunities for utility grid operations. With the rapid deployment of DERs, there is emerging interest in integrating these controllable devices with utility operations at all levels for monitoring and management. To understand the challenges with increasing behind-the-meter (BTM) DERs and to identify the needs in deploying advanced controls, a comprehensive grid impact study is indispensable. This paper presents the analysis which help visualize the DER impact on the grid, identify the challenges and provides an insight into the new distribution management and control needs to enable reliable and resilient grid operations.

behind-the-meter↗

What is the Impact of Utility Demand Charges on an Alternating Current Level 2 Elective Vehicle Supply Equipment Host?

The EVSE delivered by The EV Project included both residential and non-residential units. Approximately 4,000 non-residential ACL2 EVSE were installed in workplace environments, fleet applications and publicly accessible locations near retail centers, parking lots, and similar locations. The Blink ACL2 utilized in The EV Project is capable of charging at up to 7.2 kW power, although most vehicles in The EV Project charged at about 3.7 kW. This power can be a significant additional electrical load for the charging site host. This concern becomes greater when several EVSE are in operation on a site at the same time. Many electric utilities include maximum power demand as part of their commercial rate structure. The demand charge incurred by a commercial customer is related to the peak power used during a monthly billing cycle. This is in contrast to the total energy usage that is the more familiar utility charge seen for residential service. A demand charge is typically calculated based on the highest average power level over a 15 minute period during the monthly billing cycle and is not a cumulative-type charge. One objective of The EV Project was to elucidate the motivations and hindrances to potential site hosts of non-residential EVSE. The imposition of electric utility demand charges represents such a potential hindrance. This subject was introduced in the paper: DC Fast Charge - Demand Charge Reduction1, specifically dealing with DC Fast Chargers. The concept remains relevant to ACL2 EVSE, especially when several EVSE are deployed at the same site, which occurred frequently in the EV Project. In fact, the average number of ACL2 EVSE per site was 2.58 and varied by market from 1.79 to 3.45 per site. This paper identifies the impact of demand charges on non-residential ACL2 hosts in The EV Project

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

2015 IECC: Energy Savings Analysis

Section 304(a) of the Energy Conservation and Production Act, as amended, requires the Secretary of Energy to make a determination each time a revised edition of the 1992 Model Energy Code (MEC), or any successor thereof, is published with respect to whether the revised code would improve energy efficiency in residential buildings. The International Energy Conservation Code (IECC), as administered by the International Code Council (ICC), establishes the national model code for energy efficiency requirements for residential buildings. The latest edition of the IECC, the 2015 IECC, was published on June 3, 2014 and forms the basis of this analysis. To meet these statutory requirements, as well as to assist states and adopting entities in understanding associated savings, the DOE Building Energy Codes Program and Pacific Northwest National Laboratory (PNNL) conduct analyses to evaluate the differences between the latest edition of the IECC and its immediate predecessor. A qualitative analysis is conducted, identifying all changes made to the previous edition of the IECC, and characterizing these changes in terms of their anticipated impact on residential building energy consumption. A quantitative analysis is then modeled through building energy simulation to estimate the resulting energy impacts. This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

US Fallout Shelter

Being indoors (sheltering) reduces radiation exposures resulting from nuclear fallout or a power-plant accident. However, most US building types, particularly non-residential buildings, lack quantitative estimates. We provide here a high-level modeling analysis of modern US building protection based on a novel radiation protection building attribute taxonomy, a new building protection model, compilation of prior experimental results, and nationally representative building survey data. This approach provides a consistent, quantitative understanding of US building protection and, when combined with the distribution of people among different buildings, can assist in selecting emergency response strategies. We find that indoor radiation protection varies by orders of magnitude. Most people in non-residential buildings are adequately protected, particularly below ground or in the building center. Residential buildings are less protective and those with lighter weight walls lack adequate, above ground protection. This work also highlights key areas where further investigation will improve the current results. These include the improving the understanding of residential basement protection, additional experimental data on non-residential buildings (particularly schools and industrial buildings), and the frequency of brick veneer and stucco exterior residential buildings.

61 RADIATION PROTECTION AND DOSIMETRY↗

A study of the utilization of ERTS-1 data from the Wabash River Basin

The author has identified the following significant results. For the urban land use analysis project, classification results were good to excellent for the following classes: single family residential, commercial/industrial, cloud, cloud shadow, trees, and water. Grassy areas were defined fairly well, but residential areas located between multi-family residential and single-family residential were misclassified as grassy. Residential areas dominated by tree cover, termed wooded residential, were unable to be classified in a single class. Data points in such areas were classified randomly as either grassy or trees.

Landgrebe, D. A.↗