Search NASA⌕ Search

SEARCH · Search NASA

Results for “SCINTILLATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Design of a monolithic multichannel front-end readout ASIC for PET imaging based on scintillation crystals read out by photodetectors at both ends

This paper presents the design techniques of a monolithic multichannel front-end readout chip integrated with both high-accuracy TDC and high-resolution ADC for the PET using LYSO(Ce) crystals read out by MCP PMT at both ends. In the front-end readout chain, a regulated cascade (RGC) preamplifier is employed in every channel for amplifying the current signals generated from MCP detector. A gain-adjustment stage, an integrator and a pulse shaper are employed for pulse height analysis which changes the width of the pulses. A discriminator is placed after the preamplifier to generate triggers. These triggers are sent to a sub-nanosecond TDC for measurement and digitizing. The peak values of the shaped pulses are digitized by a multichannel time-based ADC for measurement. Three prototype chips are designed in AMS 0.35 {mu}m CMOS technology. In the front-end readout prototype chip, the dynamic range, the linearity, and the power dissipation are optimized. The input dynamic range from few fC to more than 100 pC can be achieved. The analog output range of the front-end readout circuits is from 1.2 V to 3.2 V. The shaping time is 280 ns and the power dissipation is reduced to less than 15 mW. In the TDC chip based on a DLL array, the RMS jitter and the peak-to-peak jitter of the used DLL are reduced to 7 ps and 21 ps, respectively. The bin size of the TDC has been reduced to 71 ps with a reference clock of 100 MHz. In the multichannel time-based ADC chip, a maximum resolution of 12 bits, a sampling rate of {approx}1 MS/s, and the power dissipation of 3 mW deg. 0.2 mW/channel are achieved. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast Neutron Scintillator Screens for Neutron Imaging Using a Layered Polymer-Phosphor Architecture

Fast neutrons enable a nondestructive examination of dense, large, and highly attenuating samples due to their lower interaction probability compared to thermal neutrons. However, this also creates a challenge in fast neutron imaging, as the thicker sensors necessary to detect fast neutrons degrade an image’s spatial resolution due to scattering within the sensor and the indeterminate depth of interaction in the sensor. This work explores the advantages of a fast neutron imaging screen with a layered polymer-phosphor screen approach as opposed to a mixed polymer-phosphor screen typically used in fast neutron imaging. Proton recoil is the primary conversion mechanism for fast neutron imaging. Simulations showed that the recoil proton range of typical fast neutrons is approximately 200 µm, however, tests at Idaho National Laboratory revealed that the light output of these screens increased at much greater polymer thicknesses. The NECTAR fast neutron beamline at FRM II was used to test the imaging performance of layered fast neutron imaging screens. Distinguishing between the fast-neutron and γ-ray signals is a major challenge in fast neutron imaging because all fast neutron sources also produce γ-rays. A relative comparison between a control plate and the fast neutron screen was made to distinguish between a γ-ray and fast neutron signals. MCNP modeling quantified the γ-ray and fast neutron contributions to the images measured at NECTAR, which were approximately a 75% γ-ray image.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Local atomic arrangement and scintillation properties of Eu- and Ce-doped NaYP{sub 2}O{sub 7}

Direct determination of rare earth location and local environment in NaYP{sub 2}O{sub 7} are presented. Undoped and Ln-doped NaYP{sub 2}O{sub 7} (Ln=Eu, Ce) were produced via PVA-assisted sol–gel method. Lattice parameters were determined from Rietveld refinement, showing monoclinic structure. XAS results suggested Eu{sup 3+} and Ce{sup 3+} are incorporated into NaYP{sub 2}O{sub 7} host in substitution to Y{sup 3+} site, with first coordination shell formed by six oxygen ions. Measurements at Eu edge showed a single peak in R space for Eu–O distribution. In this case, uniform interatomic distances implied to absence of significant disorder. Analysis at Ce edge presented different behavior, with Ce–O distribution characterized by a split peak in R space. Nearest neighborhood was found to be distributed with Ce occupying an off-center position in Y site. Under X-ray excitation, {sup 5}D{sub 0}→{sup 7}F{sub J} emission lines of Eu{sup 3+} were identified for NaYP{sub 2}O{sub 7}:Eu. NaYP{sub 2}O{sub 7}:Ce presented a broad emission formed by 5d→{sup 2}F{sub J} transitions of Ce{sup 3+}, with the superposition attributed to the effect of distorted oxygen octahedra around the dopant ions. - Graphical abstract: EuO{sub 6} and CeO{sub 6} octahedral arrangement relative to Y site in NaYP{sub 2}O{sub 7} host, and XEOL emission of corresponding doped samples. - Highlights: • Lattice parameters of NaYP{sub 2}O{sub 7} undoped sample confirmed monoclinic structure. • Dopants Eu and Ce are incorporated in the trivalent state. • Local order of Eu{sup 3+} and Ce{sup 3+} dopants substituting Y{sup 3+} consist of octahedral symmetry. • Off-center displacement in the case of Ce{sup 3+} position was discussed. • Luminescent properties under X-ray excitation may allow practical applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Erratum to. Energy calibration of gamma spectra in plastic scintillators using Compton kinematics [Nucl. Instr. and Meth. A 594 (2008) 232–243]

In recent work at our laboratory, we were re-examining our data and found an inconsistency between the values listed for 137 Cs in Table 2 (Siciliano et al. 2008) and results plotted for that source in Figures 11 and 12. In the course of fitting the parabolic function (Equation 4) to the Compton maxima, two ranges of channels were used when determining the parameters for 137 Cs. The parabolic fit curve shown in Figure 11 resulted from fitting channels 50 to 70. The parameters for that fit are: are: A = 0.972(12), B = 1.42(24) x 10 -3 , and C NO = 60.2(5). The parameters for 137 Cs listed in Table 2 (and also used to determine the calibration relations in Figure 12—the main result of this paper) came from fitting the 137 Cs data in channels 40 to 80. Although the curves plotted from these two different sets of parameters would be visually distinguishable in Figure 11, when incorporated with the other isotope values shown in Figure 12 to obtain the linear energy-channel fit, the 50-70 channel parameter set plus the correction from the Compton maximum to the Compton edge gives a negligible change in the slope [6.470(41) as opposed to the reported 6.454(15) keV/channel] and a small change in the intercept [41(8) as opposed to 47(3) keV] for the dashed line. The conclusions of the article therefore do not change as a result of this inconsistency.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling interactions of intermediate-energy neutrons in a plastic scintillator array with Geant4

Here, a Monte Carlo simulation of a large-area neutron time-of-flight detector, built on the Geant4 framework, has been compared with an experimental measurement of the 16 B → 15 B + n decay produced from a 55 MeV/ u 17 C beam. The ability of the Monte Carlo simulation to reproduce the intermediate-energy neutron interactions within the detector has been explored using both the stock Geant4 physics processes and a custom neutron interaction model, menate_r. The stock Geant4 physics processes were unable to reproduce the experimental observables, while excellent agreement was obtained through the inclusion of the menate_r model within Geant4. The differences between the two approaches are shown to be related to the modeling of the neutron–carbon inelastic reactions. Additionally, the use of menate_r provided accurate reproduction of experimental signals associated with neutron scattering within the detector. These results provide validation of the Monte Carlo simulation for modeling measurements of multiple neutrons where the identification and removal of false neutron signals, due to multiple neutron scattering, are required.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pulse shape discrimination in helium-4 scintillation detectors

We investigated three algorithms for discriminating between neutrons and gamma rays in a pres-surized 4 He gas fast neutron detector: charge comparison, weighted integration, and neutron-gamma model analysis (NGMA). And for each algorithm, a comprehensive pulse shape discrimination study was conducted using time-of-flight measurements, receiver operator characteristic curves, figure of merit performance measures, and a comparison of performance between 252 Cf and PuBe mixed neutron/gamma sources. The NGMA method was found to have the best overall performance by both the figure of merit and the receiver operator characteristic curve. Our results also illustrated the high gamma rejection efficiency of these detectors, which is desirable in a variety of neutron monitoring applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reflectance dependence of polytetrafluoroethylene on thickness for xenon scintillation light

Many rare event searches including dark matter direct detection and neutrinoless double beta decay experiments take advantage of the high VUV reflective surfaces made from polytetrafluoroethylene (PTFE) reflector materials to achieve high light collection efficiency in their detectors. As the detectors have grown in size over the past decade, there has also been an increased need for ever thinner detector walls without significant loss in reflectance to reduce dead volumes around active noble liquids, outgassing, and potential backgrounds. We report on the experimental results to measure the dependence of the reflectance on thickness of two PTFE samples at wavelengths near 178 nm. No change in reflectance was observed as the wall thickness of a cylindrically shaped PTFE vessel immersed in liquid xenon was varied between 1 mm to 9.5 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗