Search NASA⌕ Search

SEARCH · Search NASA

Results for “SIGNAL REFLECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

Monitoring Fracture Saturation With Internal Seismic Sources and Twin Neural Networks

Seismic coda-wave analysis is a well-developed method for detecting subtle physical changes in complex media by measuring arrival times in the late-arriving energy from multiply scattered or reflected waves. However, a challenge arises when multiply scattered waves are not sufficiently separated in time from the direct arrivals to provide a clear coda wave train. Additional complications for monitoring changes in fracture systems arise when the signals originate from unsynchronized internal sources, such as natural or induced seismicity, from acoustic emission, or from transportable intra-fracture sources (chattering dust), that generate uncontrolled signals that vary in arrival time, amplitude and frequency content. Here, we use a twin neural network (TNN also known as a Siamese neural network) for dimensionality reduction to analyze signals from chattering dust to classify the fluid saturation state of a synthetic fracture system. The TNN with shared weights generates a low-dimensional representation of the data input by minimizing contrastive loss, serving as the input to a multiclass classifier that accurately classifies whether multiple fractures in a fracture system are fully saturated or partially saturated, or whether a change in saturation has occurred in different fractures in the system. Furthermore, these results show that information buried in unresolved codas from uncontrolled sources can be extracted using machine learning to monitor the evolution of fracture systems caused by physical and chemical processes even when the scattered and direct wave fields overlap.

58 GEOSCIENCES↗

Nanostructured fibers as a versatile photonic platform: radiative cooling and waveguiding through transverse Anderson localization

Broadband high reflectance in nature is often the result of randomly, three-dimensionally structured materials. This study explores unique optical properties associated with one-dimensional nanostructures discovered in silk cocoon fibers of the comet moth, Argema mittrei. The fibers are populated with a high density of air voids randomly distributed across the fiber cross-section but are invariant along the fiber. These filamentary air voids strongly scatter light in the solar spectrum. A single silk fiber measuring ~50 μm thick can reflect 66% of incoming solar radiation, and this, together with the fibers’ high emissivity of 0.88 in the mid-infrared range, allows the cocoon to act as an efficient radiative-cooling device. Drawing inspiration from these natural radiative-cooling fibers, biomimetic nanostructured fibers based on both regenerated silk fibroin and polyvinylidene difluoride are fabricated through wet spinning. Optical characterization shows that these fibers exhibit exceptional optical properties for radiative-cooling applications: nanostructured regenerated silk fibers provide a solar reflectivity of 0.73 and a thermal emissivity of 0.90, and nanostructured polyvinylidene difluoride fibers provide a solar reflectivity of 0.93 and a thermal emissivity of 0.91. The filamentary air voids lead to highly directional scattering, giving the fibers a highly reflective sheen, but more interestingly, they enable guided optical modes to propagate along the fibers through transverse Anderson localization. This discovery opens up the possibility of using wild silkmoth fibers as a biocompatible and bioresorbable material for optical signal and image transport.

36 MATERIALS SCIENCE↗

Complementary use of monochromatic and white-beam X-ray micro-diffraction for the investigation of ancient materials

Archaeological artefacts are often heterogeneous materials where several phases coexist in a wide grain size distribution. Most of the time, retrieving structure information at the micrometre scale is of great importance for these materials. Particularly, the organization of different phases at the micrometre scale is closely related to optical or mechanical properties, manufacturing processes, functionalities in ancient times and long-term conservation. Between classic X-ray powder diffraction with a millimetre beam and transmission electron microscopy, a gap exists and structure and phase information at the micrometre scale are missing. Using a micrometre-size synchrotron X-ray beam, a hybrid approach combining both monochromatic powder micro-diffraction and Laue single-crystal micro-diffraction was deployed to obtain information from nanometre- and micrometre-size phases, respectively. Therefore providing a way to bridge the aforementioned gap, this unique methodology was applied to three different types of ancient materials that all show a strong heterogeneity. In Roman terra sigillata, the specific distribution of nanocrystalline hematite is mainly responsible for the deep-red tone of the slip, while the distribution of micrometre-size quartz in ceramic bodies reflects the change of manufacturing process between pre-sigillata and high-quality sigillata periods. In the second example, we investigated the modifications occurring in Neolithic and geological flints after a heating process. By separating the diffracted signal coming from the nano- and the micrometre scale, we observed a domain size increase for nanocrystalline quartz in geological flints and a relaxation of the residual strain in larger detritic quartz. In conclusion, through the study of a Roman iron nail, we showed that the carburation process to strengthen the steel was mainly a surface process that formed 10–20 µm size domains of single–crystal ferrite and nanocrystalline cementite.

36 MATERIALS SCIENCE↗

Vision 20/20: Magnetic resonance imaging-guided attenuation correction in PET/MRI: Challenges, solutions, and opportunities

Attenuation correction is an essential component of the long chain of data correction techniques required to achieve the full potential of quantitative positron emission tomography (PET) imaging. The development of combined PET/magnetic resonance imaging (MRI) systems mandated the widespread interest in developing novel strategies for deriving accurate attenuation maps with the aim to improve the quantitative accuracy of these emerging hybrid imaging systems. The attenuation map in PET/MRI should ideally be derived from anatomical MR images; however, MRI intensities reflect proton density and relaxation time properties of biological tissues rather than their electron density and photon attenuation properties. Therefore, in contrast to PET/computed tomography, there is a lack of standardized global mapping between the intensities of MRI signal and linear attenuation coefficients at 511 keV. Moreover, in standard MRI sequences, bones and lung tissues do not produce measurable signals owing to their low proton density and short transverse relaxation times. MR images are also inevitably subject to artifacts that degrade their quality, thus compromising their applicability for the task of attenuation correction in PET/MRI. MRI-guided attenuation correction strategies can be classified in three broad categories: (i) segmentation-based approaches, (ii) atlas-registration and machine learning methods, and (iii) emission/transmission-based approaches. This paper summarizes past and current state-of-the-art developments and latest advances in PET/MRI attenuation correction. The advantages and drawbacks of each approach for addressing the challenges of MR-based attenuation correction are comprehensively described. The opportunities brought by both MRI and PET imaging modalities for deriving accurate attenuation maps and improving PET quantification will be elaborated. Future prospects and potential clinical applications of these techniques and their integration in commercial systems will also be discussed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cultural and environmental effects on the spectral development patterns of corn and soybeans: Field data analysis

An overall approach to crop spectral understanding is presented which serves to maintain a strong link between actual plant responses and characteristics and spectral observations from ground based and spaceborne sensors. A specific technique for evaluating field reflectance data, as a part of the overall approach, is also described. Results of the application of this technique to corn and soybeans reflectance data collected by and at Purdue/LARS indicate that a number of common cultural and environmental factors can significantly affect the temporal spectral development patterns of these crops in tasseled cap greenness (a transformed variable of LANDSAT MSS signals).

Crist, E. P.↗

Directional reflectance factor distributions for cover types of Northern Africa

Directional reflectance factors that spanned the entire exitance hemisphere were collected on the ground throughout the morning period for common cover types in Tunisia, Africa. NOAA 7/8 AVHRR bands 1(0.58-0.68 micron) and 2 (0.7301.1 micron) were used in data collection. The cover types reported were a plowed field, annual grassland, steppe grassland, hard wheat, salt plain, and irrigated wheat. Several of these cover types had geometric structures that are extreme as compared to those reported in the literature. Comparisons were made between the dynamics of the observed reflectance distributions and those reported in the literature. It was found that the dynamics of the measured data could be explained by a combination of soil and vegetation scattering components. The data and analysis further validated physical principles that cause the reflectance distribution dynamics as proposed by field and simulation studies in the literature. Finally, the normalized difference transformation (Band 2 - Band 1)/(Band 1 + Band 2), which is useful in monitoring vegetation cover, generally decreased the variation in signal with changing view angle. However, several exceptions were noted.

Kimes, D. S.↗

Magnetospherically reflected whistlers as a source of plasmaspheric hiss

Ray-tracing simulations and estimates of whistler wave damping show that magnetospherically reflected whistlers can persist for about 100 s in a LF band (about 1 kHz). The combined contribution from whistler rays produced by a single lightning flash but entering the magnetosphere at different points form a continuous hisslike signal, as observed at a fixed point. Estimates indicate that the total whistler wave energy input into the magnetosphere from lightning discharges may maintain experimentally observed levels of magnetospheric hiss.

Draganov, A. B.↗

Radical is Temporary

I suspect that even if Ken had stayed on, we would have evolved to the state we're in right now. In terms of the nature of the work that we're doing, we've gone from development to maintenance, and so the project team needed to evolve to reflect that change. The analogy I use to describe Hubble is a data factory, and we provide the factory controller. The telescope takes in light and produces pictures, and we're the ones sending all of the control signals and monitoring the temperature, power, and voltages in the factory to make sure the production line is doing its job and that it's not reaching some sort of a stress point. That's basically it. We maintain the Hubble command and control system. I think we're still putting out a good quality product. We still meet our schedule and cost milestones. Every time we make a change to the ground system, we run a suite of tests to make sure that the system still runs as expected, and that it correctly controls the spacecraft. Other than that, provided the interfaces are controlled, everything is okay.

Barrett, Larry↗

On the transmission of partial information: inferences from movement-related brain potentials

Results are reported from a new paradigm that uses movement-related brain potentials to detect response preparation based on partial information. The paradigm uses a hybrid choice-reaction go/nogo procedure in which decisions about response hand and whether to respond are based on separate stimulus attributes. A lateral asymmetry in the movement-related brain potential was found on nogo trials without overt movement. The direction of this asymmetry depended primarily on the signaled response hand rather than on properties of the stimulus. When the asymmetry first appeared was influenced by the time required to select the signaled hand, and when it began to differ on go and nogo trials was influenced by the time to decide whether to respond. These findings indicate that both stimulus attributes were processed in parallel and that the asymmetry reflected preparation of the response hand that began before the go/nogo decision was completed.

NASA Discipline Space Human Factors↗

Optimization of Elastodynamic Finite Integration Technique on Intel Xeon Phi Knights Landing Processors

This work describes the development and optimization of an implementation of an isotropic elastodynamic finite integration technique (EFIT) code for parallelized computation on Intel Knights Landing (KNL) hardware. EFIT is a numerical approach resulting in standard staggered-grid finite difference equations for the elastodynamic equations of motion to simulate bulk waves is solids. The computationally efficient simulation of elastodynamic wave propagation and interactions in aerospace materials is of high-interest in the fields of nondestructive evaluation (NDE) and structural health monitoring (SHM). Ultrasonic inspection uses an ultrasonic signal, generated at the surface of the material/structure via use of a piezoelectric transducer, to propagate sound waves into the material where it interacts with any existing defects, as well as with structural boundaries and any material inhomogeneity. Reflections from defects and boundaries are then measured by a transducer. Realistic ultrasound simulation tools can significantly aid the development and optimization of inspection techniques and can assist in the interpretation of experimental data. The optimization of an elastodynamics simulation code for the KNL Many Integrated Core processor was performed. The optimization focused on data locality and vectorization. Results show that tiling of the data to exploit the cache behavior and allow for significant utilization of the KNL hardware. The MPI implementation allows for a scalable implementation enabling large problems to be simulated. The model results were validated against theoretical dispersion curves to within 2% of the group velocity, and within 0.5% of the phase velocity of the A0 mode. Aggressive use of tiling, threading, and vectorization techniques allowed for dramatically improved time to solution.

William C. Schneck↗

Addition of transient kinetics capabilities to an infrared reflection absorption spectroscopy system through synchronized gas pulsing and data acquisition

Surface science methodologies for understanding thermodynamic aspects of surface processes are at an advanced level. However, instrumentation and approaches for extracting kinetic parameters from elementary steps are far less accessible. In this work, we present an approach combining the use of a fast gas pulsing valve synchronized with data acquisition to enable surface transient kinetics studies using infrared reflection absorption spectroscopy. This methodology applies to the study of reversible processes and borrows concepts and ideas from molecular beam scattering and temporal analysis of products. Here, a temporal resolution of ~67 ms is achieved, and this is illustrated through the study of CO adsorption and desorption on a Pd(111) crystal in the presence and absence of background O 2 . The same approach can be extended to other surface spectroscopies, such as X-ray photoelectron spectroscopy, to obtain spectra with high temporal resolution and signal-to-noise ratio and enable future multimodal surface transient kinetic studies aiming at elucidating reaction mechanisms.

36 MATERIALS SCIENCE↗

Continuous Calibration Improvement in Solar Reflective Bands: Landsat 5 Through Landsat 8

Launched in February 2013, the Operational Land Imager (OLI) on-board Landsat 8 continues to perform exceedingly well and provides high science quality data globally. Several design enhancements have been made in the OLI instrument relative to prior Landsat instruments: pushbroom imaging which provides substantially improved Signal-to-Noise Ratio (SNR), spectral bandpasses refinement to avoid atmospheric absorption features, 12 bit data resolution to provide a larger dynamic range that limits the saturation level, a set of well-designed onboard calibrators to monitor the stability of the sensor. Some of these changes such as refinements in spectral bandpasses compared to earlier Landsats and well-designed on-board calibrator have a direct impact on the improved radiometric calibration performance of the instrument from both the stability of the response and the ability to track the changes. The on-board calibrator lamps and diffusers indicate that the instrument drift is generally less than 0.1% per year across the bands. The refined bandpasses of the OLI indicate that temporal uncertainty of better than 0.5% is possible when the instrument is trended over vicarious targets such as Pseudo Invariant Calibration Sites (PICS), a level of precision that was never achieved with the earlier Landsat instruments. The stability measurements indicated by on-board calibrators and PICS agree much better compared to the earlier Landsats, which is very encouraging and bodes well for the future Landsat missions too.

Nischal Mishra↗

Compact folded metasurface spectrometer

Abstract An optical design space that can highly benefit from the recent developments in metasurfaces is the folded optics architecture where light is confined between reflective surfaces, and the wavefront is controlled at the reflective interfaces. In this manuscript, we introduce the concept of folded metasurface optics by demonstrating a compact spectrometer made from a 1-mm-thick glass slab with a volume of 7 cubic millimeters. The spectrometer has a resolution of ~1.2 nm, resolving more than 80 spectral points from 760 to 860 nm. The device is composed of three reflective dielectric metasurfaces, all fabricated in a single lithographic step on one side of a substrate, which simultaneously acts as the propagation space for light. The folded metasystem design can be applied to many optical systems, such as optical signal processors, interferometers, hyperspectral imagers, and computational optical systems, significantly reducing their sizes and increasing their mechanical robustness and potential for integration.

47 OTHER INSTRUMENTATION↗

Note: Elastic wave velocity measurement using ultrasonic system with two-reflectors

We show an experiment protocol for ultrasonic velocity measurements carried out in a synchrotron-based multi-anvil high-pressure apparatus. By adding a second reflector in the cell assembly, ultrasonic signals are significantly stabilized for experiments where samples experience structural changes such as phase transition or partial melting. Features of the elastic wave can be calculated from acoustic impedance allowing us to evaluate the possible interference between the sample reflection and other internal multiple reflections. This new protocol allows various forms of samples including cold-pressed powder samples, for which grain size and porosity can be monitored and controlled in situ during the annealing process.

47 OTHER INSTRUMENTATION↗

Fluorescence intensity monitors as intensity and beam-position diagnostics for X-ray free-electron lasers

For LCLS-II, a fluorescence intensity monitor for the non-invasive, pulse-by-pulse normalization of experiments has been developed. A prototype diagnostic was constructed with a microchannel plate assembly and two photodiodes. The diagnostic was then installed in the LCLS SXR instrument Kirkpatrick–Baez mirror chamber with the detectors located above the vertically reflecting mirror. The linearity, noise and position sensitivity of the detectors have been characterized. The photodiode responsivity is suitable for high pulse energies. The microchannel plate detector shows sufficient responsivity over a wide range of pulse energies. The relative signal from the two photodiodes provides a sensitive measure of the X-ray beam position. The fluorescence intensity monitor provides intensity normalization while being compatible with high incident power, a 0.93 MHz repetition rate and ultra-high vacuum.

47 OTHER INSTRUMENTATION↗

SU-F-T-525: Monitordeep-Inspiratory Breathhold with a Laser Sensor for Radiation Therapy of Left Breast Cancer

Purpose: Radiation therapy (RT) of left sided breast cancers with deep-inspiratory breathhold (DIBH) can reduce the dose to heart. The purpose of this study is to develop and test a new laser-based tool to improve ease of RT delivery using DIBH. Methods: A laser sensor together with breathing monitor device (Anzai Inc., Japan) was used to record the surface breathing motion of phantom/volunteers. The device projects a laser beam to the chestwall and the reflected light creates a focal spot on a light detecting element. The position change of the focal spot correlates with the patient’s breathing motion and is measured through the change of current in the light detecting element. The signal is amplified and displayed on a computer screen, which is used to trigger radiation gating. The laser sensor can be easily mounted to the simulation/treatment couch with a fixing plate and a magnet base, and has a sensitivity range of 10 to 40 cm from the patient. The correlation of breathing signals detected by laser sensor and visionRT is also investigated. Results: It is found that the measured breathing signal from the laser sensor is stable and reproducible and has no noticeable delay. It correlates well with the VisionRT surface imaging system. The DIBH reference level does not change with movement of the couch because the laser sensor and couch move together. Conclusion: The Anzai laser sensor provides a cost-effective way to improve beam gating with DIBH for treating left breast cancer. It can be used alone or together with VisionRT to determine the correct DIBH level during the radiation treatment of left breast cancer with DIBH.

60 APPLIED LIFE SCIENCES↗

5ω Optical Thomson Scattering Report

The 5ω Optical Thomson Scattering system on the National Ignition Facility (NIF) is a diagnostic designed to measure temporally and spatially resolved plasma conditions in Inertial Confinement Fusion (ICF) Hohlraums. The system was proposed in 2014 and a phased approach to implementation was developed. In phase one the collection system was designed, built, and fielded on the NIF to be used for 3ω Thomson scattering measurements and background measurements near 211 nm (5ω. The initial commissioning experiment for the collection system was completed in Oct. 2016. Commissioning of the collection system continued through 2017 and the system is now fielded for a range of user experiments and regularly produces publication quality data. A dedicated 5ω probe laser was designed and built to allow Thomson scattering measurements in the presence of 2 MJ of 3ω drive energy. Due to scattered light (spectral reflections, laser-plasma instabilities, and unconverted drive energy) from the 3w drive lasers typical wavelengths (2ω and 4ω) fielded at other laser facilities like the Nova Laser Facility and the Omega Laser Facility were unable to meeting the signal to background requirements in design studies. A 10 Joule 5ω probe was proposed as a solution that met requirements. This 10 Joule laser was more energetic than previously fielded 5w lasers by 2-3 orders of magnitude. As part of a risk reduction plan, phase two of the project was to develop a 1 Joule, 5ω laser to demonstrate conversion efficiency >20% from 1ω to 5ω and make initial Thomson scattering measurements in the first few nanoseconds of an ICF laser pulse. Initial tests of the 5w conversion were completed at the Laboratory for Laser Energetics (LLE) and produced record 5ω energies. Based on these results from LLE, a 1 Joule, 5w laser system was designed for the NIF in 2018 and commissioning began in 2019. Commissioning of the 5ω laser system continued through 2023 and was eventually paused in Q1 of FY24 due to completing resource constraints. Commissioning of the 5w laser system proved incredibly challenging. Multiple issues were identified during commissioning and resolved, but issues remain. Currently there is not a clear understanding of why 5ω scattered has not been detected on the OTS collection system. Based on offline measurements, calculations, and preshot measurements the system appears to meet all requirements. Potential target physics issues have been investigated and do not appear to be an issue. The current hypothesis is that there is an error in one or more aspects of the offline testing not translating to expected performance when the system is fielded on the NIF. Additional full system testing in-situ utilizing the complete OTS system and NIF target chamber center time is needed to further test potential failure modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Data for Monitoring Fracture Saturation with Internal Transportable Seismic Sources and Twin Neural Networks

Seismic coda-wave analysis is a well-developed method for detecting subtle physical changes in complex media by measuring arrival times in the late-arriving energy from multiply-scattered or reflected waves. However, a challenge arises when multiply-scattered waves are not sufficiently separated in time from the direct arrivals to provide a clear coda wave train. Additional complications for monitoring changes in fracture systems arise when the signals originate from unsynchronized internal sources, such as natural induced seismicity, from acoustic emission, or from transportable intra-fracture sources (chattering dust), that generate uncontrolled signals that vary in arrival time, amplitude and frequency content. Here, we use a twin neural network (also known as a Siamese neural network) for dimensionality reduction to analyze signals from chattering dust to classify the fluid saturation state of a synthetic fracture system. The twin neural network with shared weights generates a low-dimensional representation of the data input by minimizing contrastive loss, serving as the input to a multiclass classifier that accurately classifies whether multiple fractures in a fracture system are fully saturated or partially saturated, or whether a change in saturation has occurred in different fractures in the system. These results show that information buried in unresolved codas from uncontrolled sources can be extracted using machine learning to monitor the evolution of fracture systems caused by physical and chemical processes even when the scattered and direct wave fields overlap.

58 GEOSCIENCES↗