Search NASA⌕ Search

SEARCH · Search NASA

Results for “STATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

End station for nanoscale magnetic materials study: Combination of scanning tunneling microscopy and soft X-ray magnetic circular dichroism spectroscopy

We have constructed an end station for nanoscale magnetic materials study at the soft X-ray beamline HiSOR BL-14 at Hiroshima Synchrotron Radiation Center. An ultrahigh-vacuum scanning tunneling microscope (STM) was installed for an in situ characterization of nanoscale magnetic materials in combination with soft X-ray magnetic circular dichroism (XMCD) spectroscopy experiment. The STM was connected to the XMCD experimental station via damper bellows to isolate it from environmental vibrations, thus achieving efficient spatial resolution for observing Si(111) surface at atomic resolution. We performed an in situ experiment with STM and XMCD spectroscopy on Co nanoclusters on an Au(111) surface and explored its practical application to investigate magnetic properties for well-characterized nanoscale magnetic materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear and in-source laser spectroscopy with the ISAC yield station

A new decay station has been built for the ISAC facility at TRIUMF for the rapid and reliable characterization of radioactive ion beam (RIB) compositions and intensities with the capability of simultaneously collecting α, β, and γ decay data from RIB with intensities between a few and ≈10{sup 11} ions per second. It features user-friendly control, data acquisition, and analysis software. The analysis of individual decay time structures allows the unambiguous assignment of α and γ lines even with substantial isobaric contamination present. The capability for accurate half-life measurements is demonstrated with the example of {sup 46}K. The coupling of the yield station to the laser ion source, TRILIS, allows the correlation of radiometric data with automated laser frequency scans. First results of in-source laser spectroscopy measurements on astatine are discussed.

43 PARTICLE ACCELERATORS↗

Experimental station for laser-based picosecond time-resolved x-ray absorption near-edge spectroscopy

We present an experimental station designed for time-resolved X-ray Absorption Near-Edge Spectroscopy (XANES). It is based on ultrashort laser-plasma x-ray pulses generated from a table-top 100 mJ-class laser at 10 Hz repetition rate. A high transmission (10%–20%) x-ray beam line transport using polycapillary optics allows us to set the sample in an independent vacuum chamber, providing high flexibility over a wide spectral range from 0.5 up to 4 keV. Some XANES spectra are presented, demonstrating 1% noise level in only ∼1 mn and ∼100 cumulated laser shots. Time-resolved measurements are reported, indicating that the time resolution of the entire experimental station is 3.3 ± 0.6 ps rms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Operational and biological effects zones from base stations of cellular telephony

The possible environmental impacts of cellular base stations are operational and biological. The operational effects comprise Εlectro-Μagnetic Interference (EMI), lightning alterations and aesthetic degradation. Both thermal and non-thermal biological effects depend on the absorption of UHF radiofrequencies used. We measured, calculated and estimated the impact zones. The results are: (a) The lightning lethal zone equal to the antenna height, (b) the EMI impact in a zone up to 40m and (c) the ICNIRP’s limits exceed to a zone of 8∼20m into the antenna’s radiation pattern (for 2G GSM and 3G UMTS station). Finally we conclude the adverse effects must not expected in a zone of more than 150m from the radiated antenna, whereas, there is possibility of stochastic effects in intermediate distances (20/40-150m).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Multi-extreme conditions at the Second Target Station

Three concepts for the application of multi-extreme conditions under in situ neutron scattering are described here. The first concept is a neutron diamond anvil cell made from a non-magnetic alloy. It is shrunk in size to fit existing magnets and future magnet designs and is designed for best pressure stability upon cooling. This will allow for maximum pressures above 10 GPa to be applied simultaneously with (steady-state) high magnetic field and (ultra-)low temperature. Additionally, an implementation of miniature coils for neutron diamond cells is presented for pulsed-field applications. The second concept presents a set-up for laser-heating a neutron diamond cell using a defocused CO 2 laser. Cell, anvil, and gasket stability will be achieved through stroboscopic measurements and maximum temperatures of 1500 K are anticipated at pressures to the megabar. The third concept presents a hybrid levitator to enable measurements of solids and liquids at temperatures in excess of 4000 K. This will be accomplished by a combination of bulk induction and surface laser heating and hyperbaric conditions to reduce evaporation rates. The potential for deployment of these multi-extreme environments within this first instrument suite of the Second Target Station is described with a special focus on VERDI, PIONEER, CENTAUR, and CHESS. Furthermore, considerations for deployment on future instruments, such as the one proposed as TITAN, are discussed. Overall, the development of these multi-extremes at the Second Target Station, but also beyond, will be highly advantageous for future experimentation and will give access to parameter space previously not possible for neutron scattering.

47 OTHER INSTRUMENTATION↗

The FRIB Decay Station: New Horizons with Rare Isotopes

In May 2022, the Facility for Rare Isotope Beams (FRIB), located on the campus of Michigan State University (MSU), began delivering exotic isotopes to an international community of scientists. New discoveries are now being reported from radioactive decay of neutron-rich nuclei near N = 20 and N = 28.FRIB is expected to produce roughly 80% of the unstable or radioactive isotopes predicted to exist up to uranium (Z = 92). The new user facility is supported by the U.S. Department of Energy, and it is operated by MSU. A high-power superconducting linear accelerator, shaped like a paper-clip, drives the production of these rare isotopes by colliding stable nuclei moving at half the speed of light with a rotating, water-cooled graphite tar-get. These collisions cause the primary stable beam to fragment into a wide variety of unstable nuclei, which can be subsequently filtered through a multistage magnetic separator, the Advanced Rare Isotope Separator, and transported to one of several experimental stations. The FRIB Decay Station initiator (FDSi) (see Figure 1) was developed to enable comprehensive radio-active decay studies of the exotic nuclei produced by FRIB and it was used in the first two experiments in 2022. Further, the FDSi is a highly reconfigurable multidetector system with two focal planes (FP1 for discrete spectroscopy and FP2 for total absorption spectroscopy) that can be optimized for the specific science goals of each experiment. It is designed, built, and operated by a community of users with the sup-port of U.S. funding agencies, including the Department of Energy and National Science Foundation.

07 ISOTOPE AND RADIATION SOURCES↗

DETECTION OF FAST RADIO TRANSIENTS WITH MULTIPLE STATIONS: A CASE STUDY USING THE VERY LONG BASELINE ARRAY

Recent investigations reveal an important new class of transient radio phenomena that occur on submillisecond timescales. Often, transient surveys' data volumes are too large to archive exhaustively. Instead, an online automatic system must excise impulsive interference and detect candidate events in real time. This work presents a case study using data from multiple geographically distributed stations to perform simultaneous interference excision and transient detection. We present several algorithms that incorporate dedispersed data from multiple sites, and report experiments with a commensal real-time transient detection system on the Very Long Baseline Array. We test the system using observations of pulsar B0329+54. The multiple-station algorithms enhanced sensitivity for detection of individual pulses. These strategies could improve detection performance for a future generation of geographically distributed arrays such as the Australian Square Kilometre Array Pathfinder and the Square Kilometre Array.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nanosecond-level time synchronization of autonomous radio detector stations for extensive air showers

To exploit the full potential of radio measurements of cosmic-ray air showers at MHz frequencies, a detector timing synchronization within 1 ns is needed. Large distributed radio detector arrays such as the Auger Engineering Radio Array (AERA) rely on timing via the Global Positioning System (GPS) for the synchronization of individual detector station clocks. Unfortunately, GPS timing is expected to have an accuracy no better than about 5 ns. In practice, in particular in AERA, the GPS clocks exhibit drifts on the order of tens of ns. We developed a technique to correct for the GPS drifts, and an independent method used for cross-checks that indeed we reach nanosecond-scale timing accuracy by this correction. First, we operate a “beacon transmitter” which emits defined sine waves detected by AERA antennas recorded within the physics data. The relative phasing of these sine waves can be used to correct for GPS clock drifts. In addition to this, we observe radio pulses emitted by commercial airplanes, the position of which we determine in real time from Automatic Dependent Surveillance Broadcasts intercepted with a software-defined radio. From the known source location and the measured arrival times of the pulses we determine relative timing offsets between radio detector stations. We demonstrate with a combined analysis that the two methods give a consistent timing calibration with an accuracy of 2 ns or better. Consequently, the beacon method alone can be used in the future to continuously determine and correct for GPS clock drifts in each individual event measured by AERA.

47 OTHER INSTRUMENTATION↗

Design of the cryogenic moderator system for the second target station

The Second Target Station (STS) at Oak Ridge National Laboratory will be a 700 kW pulsed spallation neutron source designed to provide the world's highest brightness cold neutron beams. In order to produce the required neutron performance, two compact liquid hydrogen moderators are located adjacent to the tungsten spallation target and must be supplied with less than 20 K hydrogen and a para hydrogen fraction of 99.8% or greater. The Cryogenic Moderator System (CMS) will consist of a single hydrogen loop feeding the two moderators in series cooled by a helium refrigerator with a cooling capacity of 2.5 kW at 17 K. The hydrogen loop consists of a hydrogen circulator, hydrogen helium heat exchanger, ortho-para converter, accumulator, transfer lines and heater. The design of the hydrogen loop is based on the CMS design of the First Target Station at the Spallation Neutron Source and some of the component designs may be reused. General hydrogen temperature control is provided by controlling the flowrate of helium to the heat exchanger. The hydrogen loop will have a constant flowrate of 0.5 L/s and remove a nuclear heat load of about 850 W from the two moderators, which is deposited both directly in the hydrogen and the adjacent hydrogen containing structures. Because the nuclear heat load is accelerator driven, the hydrogen system must remain stable when the heat load is removed instantaneously during beam trips. System stability is maintained passively with the accumulator and actively with the heater. Ionizing radiation which interacts with the liquid hydrogen drives backconversion of the hydrogen from parahydrogen to orthohydrogen. The STS moderator performance is very sensitive to small fractions of orthohydrogen requiring an ortho-para converter to maintain the hydrogen supplied to the moderators at near equilibrium parahydrogen concentration. STS CMS is in the early stage of preliminary design and current focus is evaluating component sizing and system stability during beam transients.

Janney, Jim↗

Applicability of ASST-A Helium Refrigeration System for JLab End Station Refrigerator

The MØLLER experiment at Jefferson Lab (JLab) is a high power (5 kW) liquid hydrogen target scheduled to be operational in the 12 GeV-era. At present, cryogenic loads and targets at three of JLab's four experimental halls are supported by the End Station Refrigerator (ESR) - a CTI/Helix 1.5 kW 4.5 K refrigerator. It is not capable of supporting the high power target load and a capacity upgrade of the ESR cryogenic system is essential. The ASST-A helium refrigeration system is a 4 kW 4.5 K refrigerator. It was designed and used for the Superconducting Super Collider Lab (SSCL) magnet string test and later obtained by JLab after the cancellation of that project. The modified ASST-A refrigeration system, which will be called ESR-II along with a support flow from JLab's Central Helium Liquefier (CHL) is considered as an option for the End Station Refrigerator capacity upgrade. The applicability of this system for ESR-II under varying load conditions is investigated. The present paper outlines the findings of this process study.

42 ENGINEERING↗

Optical atomic clock aboard an Earth-orbiting space station (OACESS): enhancing searches for physics beyond the standard model in space

We present a concept for a high-precision optical atomic clock (OAC) operating on an Earth-orbiting space station. This pathfinder science mission will compare the space-based OAC with one or more ultra-stable terrestrial OACs to search for space-time-dependent signatures of dark scalar fields that manifest as anomalies in the relative frequencies of station-based and ground-based clocks. This opens the possibility of probing models of new physics that are inaccessible to purely ground-based OAC experiments where a dark scalar field may potentially be strongly screened near Earth's surface. This unique enhancement of sensitivity to potential dark matter candidates harnesses the potential of space-based OACs.

79 ASTRONOMY AND ASTROPHYSICS↗

GAMMA SPECTRUM STABILIZATION FOR ENVIRONMENTAL RADIATION MONITORING STATIONS USING NAI(TL) DETECTOR

Abstract Gamma spectrum measured by an NaI(Tl) detector is known to be unstable with the in situ temperature. In the present work, an advanced method has been applied to stabilize the gamma spectrum measured by the NaI(Tl) detector at environmental radiation monitoring (ERM) stations. The method is based on experimental data obtained under controlled conditions in laboratory. In the temperature range from 4 to 45°C, the relative deviation of the peak positions within the stabilized gamma spectrum is less than 2%. To test this method in a real scenario, it has been integrated into the ERM station at the Military Institute of Chemical and Environmental Engineering in Hanoi, Vietnam. The results show that the proposed method is ready for a real application.

Hung, Dinh Tien↗

Proton Shell Gaps in N = 28 Nuclei from the First Complete Spectroscopy Study with FRIB Decay Station Initiator

The first complete measurement of the $β$-decay strength distribution of $_{17}^{45}$Cl 28 was performed at the Facility for Rare Isotope Beams (FRIB) with the FRIB Decay Station Initiator during the second FRIB experiment. The measurement involved the detection of neutrons and $γ$ rays in two focal planes of the FRIB Decay Station Initiator in a single experiment for the first time. This enabled an analytical consistency in extracting the $β$-decay strength distribution over the large range of excitation energies, including neutron unbound states. Here, we observe a rapid increase in the $β$-decay strength distribution above the neutron separation energy in $_{18}^{45}$Ar 27 . This was interpreted to be caused by the transitioning of neutrons into protons excited across the Z = 20 shell gap. The SDPF-MU interaction with reduced shell gap best reproduced the data. The measurement demonstrates a new approach that is sensitive to the proton shell gap in neutron rich nuclei according to SDPF-MU calculations.

39 ≤ A ≤ 58↗

Macromolecular neutron crystallography at the Protein Crystallography Station (PCS)

The Protein Crystallography Station user facility at Los Alamos National Laboratory not only offers open access to a high-performance neutron beamline, but also actively supports and develops new methods in protein expression, deuteration, purification, robotic crystallization and the synthesis of substrates with stable isotopes and provides assistance with data-reduction and structure-refinement software and comprehensive neutron structure analysis. The Protein Crystallography Station (PCS) at Los Alamos Neutron Science Center is a high-performance beamline that forms the core of a capability for neutron macromolecular structure and function determination. Neutron diffraction is a powerful technique for locating H atoms and can therefore provide unique information about how biological macromolecules function and interact with each other and smaller molecules. Users of the PCS have access to neutron beam time, deuteration facilities, the expression of proteins and the synthesis of substrates with stable isotopes and also support for data reduction and structure analysis. The beamline exploits the pulsed nature of spallation neutrons and a large electronic detector in order to collect wavelength-resolved Laue patterns using all available neutrons in the white beam. The PCS user facility is described and highlights from the user program are presented.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CAMP@FLASH: an end-station for imaging, electron- and ion-spectroscopy, and pump–probe experiments at the FLASH free-electron laser

The non-monochromatic beamline BL1 at the FLASH free-electron laser facility at DESY was upgraded with new transport and focusing optics, and a new permanent end-station, CAMP, was installed. This multi-purpose instrument is optimized for electron- and ion-spectroscopy, imaging and pump–probe experiments at free-electron lasers. It can be equipped with various electron- and ion-spectrometers, along with large-area single-photon-counting pnCCD X-ray detectors, thus enabling a wide range of experiments from atomic, molecular, and cluster physics to material and energy science, chemistry and biology. Here, an overview of the layout, the beam transport and focusing capabilities, and the experimental possibilities of this new end-station are presented, as well as results from its commissioning.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fifteen years of the Protein Crystallography Station: The coming of age of macromolecular neutron crystallography

The Protein Crystallography Station (PCS), located at the Los Alamos Neutron Scattering Center (LANSCE), was the first macromolecular crystallography beamline to be built at a spallation neutron source. Following testing and commissioning, the PCS user program was funded by the Biology and Environmental Research program of the Department of Energy Office of Science (DOE-OBER) for 13 years (2002–2014). The PCS remained the only dedicated macromolecular neutron crystallography station in North America until the construction and commissioning of the MaNDi and IMAGINE instruments at Oak Ridge National Laboratory, which started in 2012. The instrument produced a number of research and technical outcomes that have contributed to the field, clearly demonstrating the power of neutron crystallography in helping scientists to understand enzyme reaction mechanisms, hydrogen bonding and visualization of H-atom positions, which are critical to nearly all chemical reactions. During this period, neutron crystallography became a technique that increasingly gained traction, and became more integrated into macromolecular crystallography through software developments led by investigators at the PCS. As a result, this review highlights the contributions of the PCS to macromolecular neutron crystallography, and gives an overview of the history of neutron crystallography and the development of macromolecular neutron crystallography from the 1960s to the 1990s and onwards through the 2000s.

59 BASIC BIOLOGICAL SCIENCES↗

Enhancing EV Charging Station Resilience with Multifunctional Converter Leg Integration

In this paper, a multifunctional converter leg is integrated into an EV charger’s power circuit to enhance EV charging station resilience under power electronics converter device faults and grid outages. In the event of a device fault, it substitutes the failed converter leg, maintaining operation. During a grid outage, it assists the system as a fourth leg to the front-end converter, enabling grid-forming capability to supply power to the charging station critical loads while allowing limited power vehicle charging. The proposed approach’s effectiveness under both front-end power converter device faults and grid outage scenarios are validated through simulation and controller hardware-in-the-loop results.

Pereira Pinto, Joao [ORNL]↗

Improving Resiliency in Planning MW-Scale Medium and Heavy Duty EV Charging Stations Considering TSCOTS Optimization

Electrification of heavy-duty (HD) vehicles marks an important milestone and technical challenge in the electric vehicle (EV) industry and the public grid. However, implementing EV charging at this scale will necessitate that traditional truck stops be updated with EV charging infrastructure that could represent 10's of MW in electricity consumption. Furthermore, as the transportation sector is represented as critical infrastructure, supporting resiliency considerations in EV charging infrastructure will be critical. This paper proposes an optimization-based approach for optimally designing a MW-scale microgrid charging network. This approach transforms conventional designed truck stops into a reliable HDEV charging stations capable of overnight slow charging and 30-minute to 1 hour fast charging. Using a mixed-integer linear program formulation blending capacity planning and reliability constraints, an optimal network configuration can be solved for a proposed EV charging station that includes photovoltaic and battery energy storage capabilities.

Ponce, Moises [University of Tennessee, Knoxville ↗