Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sensitivity Matrix”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,441 records · Page 80

On equivalence of discrete-discrete and continuum-discrete design sensitivity analysis

Developments in design sensitivity analysis (DSA) method have been made using two fundamentally different approaches as shown. In the first approach, a discretized structural finite element model is used to carry out DSA. There are three different methods in the discrete DSA approach: finite difference, semi-analytical, and analytical methods. The finite difference method is a popular one due to its simplicity, but a serious shortcoming of the method is the uncertainty in the choice of a perturbation step size of design variables. In the semi-analytical method, the derivatives of stiffness matrix is computed by finite differences, whereas in the analytical method, the derivatives are obtained analytically. For the shape design variable, computation of analytical derivative of stiffness matrix is quite costly. Because of this, the semi-analytical method is a popular choice in discrete shape DSA approach. However, recently, Barthelemy and Haftka presented that the semi-analytical method can have serious accuracy problems for shape design variables in structures modeled by beam, plate, truss, frame, and solid elements. They found that accuracy problems occur even for a simple cantilever beam. In the second approach, a continuum model of the structure is used to carry out DSA.

Choi, Kyung K.↗

Solid Carbonyl Sulphide (OCS) in W33A

We present ground-based observations of the 2041/cm (4.9 micrometer) absorption feature toward the deeply embedded protostar W33A. We attribute this interstellar feature to solid carbonyl sulphide (OCS) embedded in icy grain mantles along the line of sight. We have made an extensive laboratory study of the infrared characteristics of OCS in various ice mixtures. Studies of the 2041/cm band of solid OCS and solid mixtures containing OCS show that its shape and peak position are sensitive to the molecular environment of the OCS molecule. Mie scattering calculations show that the peak position and profile of the OCS band depend on the shape and size of the absorbing grain when the OCS concentration is larger than 0.05. For lower OCS concentrations, laboratory-measured bulk spectra agree very well with the absorption spectra of small grains. We have compared the observed feature with laboratory and theoretical spectra of astrophysically relevant mixtures. The best agreement is obtained for mixtures with traces of OCS in a methanol-rich matrix. This would suggest the presence of independent grain components and in particular of a minor fraction of methanol-rich icy grain mantles in which OCS is embedded. From the strength of the absorption feature we deduce a OCS/H 20 ratio, along the line of sight, of 4 x 10(exp -4).

Palumbo, M. E.↗

Solid Carbonyl Sulphide (OCS) in W33A

We present ground-based observations of the 2041 cm(exp -1) (4.9 mm) absorption feature toward the deeply embedded protostar W33A. We attribute this interstellar feature to solid carbonyl sulphide (OCS) embedded in icy grain mantles along the line of sight. We have made an extensive laboratory study of the infrared characteristics of OCS in various ice mixtures. Studies of the 2041 cm(exp -1) band of solid OCS and solid mixtures containing OCS show that its shape and peak position are sensitive to the molecular environment of the OCS molecule. Mie scattering calculations show that the peak position and profile of the OCS band depend on the shape and size of the absorbing grain when the OCS concentration is larger than 0.05. For lower OCS concentrations, laboratory-measured bulk spectra agree very well with the absorption spectra of small grains. We have compared the observed feature with laboratory and theoretical spectra of astrophysically relevant mixtures. The best agreement is obtained for mixtures with traces of OCS in a methanol-rich matrix. This would suggest the presence of independent grain components and in particular of a minor fraction of methanol-rich icy grain mantles in which OCS is embedded. From the strength of the absorption feature we deduce a OCS/H2O ratio, along the line of sight, of 4 x 10(exp -4).

Palumbo, M. E.↗

Sensitivity Analysis of X-ray Spectra from Scanning Electron Microscopes

The primary goal of this project is to evaluate x-ray spectra generated within a scanning electron microscope (SEM) to determine elemental composition of small samples. This will be accomplished by performing Monte Carlo simulations of the electron and photon interactions in the sample and in the x-ray detector. The elemental inventories will be determined by an inverse process that progressively reduces the difference between the measured and simulated x-ray spectra by iteratively adjusting composition and geometric variables in the computational model. The intended benefit of this work will be to develop a method to perform quantitative analysis on substandard samples (heterogeneous phases, rough surfaces, small sizes, etc.) without involving standard elemental samples or empirical matrix corrections (i.e., true standardless quantitative analysis).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Light scalar dark matter at neutrino oscillation experiments

Couplings between light scalar dark matter (DM) and neutrinos induce a perturbation to the neutrino mass matrix. If the DM oscillation period is smaller than ten minutes (or equivalently, the DM particle is heavier than 0.69×10 -17 eV), the fast-averaging over an oscillation cycle leads to a modification of the measured oscillation parameters. Here, we present a specific μ - $\tau$ symmetric model in which the measured value of θ 13 is entirely generated by the DM interaction, and which reproduces the other measured oscillation parameters. For a scalar DM particle lighter than 10 -15 eV, adiabatic solar neutrino propagation is maintained. A suppression of the sensitivity to CP violation at long baseline neutrino experiments is predicted in this model. We find that DUNE cannot exclude the DM scenario at more than 3σ C.L. for bimaximal, tribimaximal and hexagonal mixing, while JUNO can rule it out at more than 6σ C.L. by precisely measuring both θ 12 and θ 13 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The effect of tantalum and carbon on the structure/properties of a single crystal nickel-base superalloy

The microstructure, phase chemistry, and creep and hot tensile properties were studied as a function of tantalum and carbon levels in Mar-M247 type single crystal alloys. Microstructural studies showed that several types of carbides (MC, M23C6 and M5C) are present in the normal carbon (0.10 wt % C) alloys after heat treatment. In general, the composition of the MC carbides changes from titanium rich to tantalum rich as the tantalum level in the alloy increases. Small M23C6 carbides are present in all alloys. Tungsten rich M6C carbides are also observed in the alloy containing no tantalum. No carbides are present in the low carbon (0.01 wt % C) alloy series. The morphology of gamma prime is observed to be sensitive to heat treatment and tantalum level in the alloy. Cuboidal gamma prime is present in all the as cast structures. After heat treatment, the gamma prime precipitates tend to have a more spheroidal like morphology, and this tendency increases as the tantalum level decreases. On prolonged aging, the gamma prime reverts back to a cuboidal morphology or under stress at high temperatures, forms a rafted structure. The weight fraction and lattice parameter of the spheroidal gamma prime increases with increasing tantalum content. Changes in the phase chemistry of the gamma prime matrix and gamma prime have also been analyzed using phase extraction techniques. The partitioning ratio decreases for tungsten and aluminum and increases for tantalum as the tantalum content increases for both alloy series; no significant changes occur in the partitioning ratios of the other alloying elements. A reduction in secondary creep rate and an increase in rupture time result from increasing the tantalum content and decreasing the carbon level.

Nguyen, H. C.↗

Effects of Aging-Time Reference on the Long Term Behavior of the IM7/K3B Composite

An analytical study was undertaken to investigate the effects of the time-based shift reference on the long term behavior of the graphite reinforced thermoplastic polyimide composite IM7/K3B at elevated temperature. Creep compliance and the effects of physical aging on the time dependent response was measured for uniaxial loading at several isothermal conditions below the glass transition temperature (T(sub g). Two matrix dominated loading modes, shear and transverse, were investigated in tension and compression. The momentary sequenced creep/aging curves were collapsed through a horizontal (time) shift using the shortest, middle and longest aging time curve as the reference curve. Linear viscoelasticity was used to characterize the creep/recovery behavior and superposition techniques were used to establish the physical aging related material constants. The use of effective time expressions in a laminated plate model allowed for the prediction of long term creep compliance. The effect of using different reference curves with time/aging-time superposition was most sensitive to the physical aging shift rate at lower test temperatures. Depending on the loading mode, the reference curve used can result in a more accurate long term prediction, especially at lower test temperatures.

Veazie, David R.↗

Extraordinary Hall effect and universal scaling in Fe{sub x}(ZnO){sub 1–x} granular thin films at room temperature

On the benefit of the concept of the so-called diluted magnetic oxides, Fe{sub x}(ZnO){sub 1–x} (x = 0.50–0.85) granular thin films with different thickness through 2D and 3D percolation region were prepared by ion beam assisted deposition. All samples are ferromagnetic at room-temperature due to the ferromagnetic nature of the Fe-doped ZnO matrix, which is quite different from the superparamagnetic behavior in the insulator-matrix based granular films. Along with decreasing thickness, the Hall coefficient R{sub S} is largely enhanced. The maximum R{sub S} reaches 4.27 × 10{sup −7} m{sup 3}/C in ∼2.8 nm Fe{sub 0.6}(ZnO){sub 0.4} granular film, which is nearly 9 times larger than the R{sub S} (4.64 × 10{sup −8} m{sup 3}/C) of the ∼50 nm Fe{sub 0.6}(ZnO){sub 0.4} sample. Meanwhile, the R{sub S} could maintain in a wide temperature region from 10 K to 300 K and the Hall sensitivity reaches ∼130 V/AT at room-temperature. The scaling exponential of n = 1.7 ± 0.1 in σ{sub xy}∼σ{sub xx}{sup n} is observed, fitting well with the recent developed universal scaling theory characterized by n = 1.6 in the dirty limit.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

An Unbalanced Sinuous Antenna for Near-Surface Polarimetric Ground-Penetrating Radar

Sinuous antennas are capable of producing ultra-wideband radiation with polarization diversity. This capability makes the sinuous antenna an attractive candidate for UWB polarimetric radar applications. Additionally, the ability of the sinuous antenna to be implemented as a planar structure makes it a good fit for close-in sensing applications such as ground-penetrating radar (GPR). In this work, each arm of a four-port sinuous antenna is operated independently to achieve a quasi-monostatic antenna system capable of polarimetry while separating transmit and receive channels—which is often desirable in GPR systems. The quasi-monostatic configuration of the sinuous antenna reduces system size as well as prevents extreme bistatic angles, which may significantly reduce sensitivity when attempting to detect near-surface targets. A prototype four-port sinuous antenna is fabricated and integrated into a GPR testbed. The polarimetric data obtained with the antenna is then used to distinguish between buried target symmetries.

47 OTHER INSTRUMENTATION↗

Uptakes of Cs and Sr on San Joaquin soil measured following ASTM method C1733

Series of tests were conducted following ASTM Standard Procedure C1733 to evaluate the repeatability of the test and the effects of several test parameters, including the solution-to-soil mass ratio, test duration, pH, and the concentrations of contaminants in the solution. This standard procedure is recommended for measuring the distribution coefficient (K d ) of a contaminant in a specific soil/groundwater system. One objective of the current tests was to identify experimental conditions that can be used in future interlaboratory studies to determine the reproducibility of the test method. This includes the recommendation of a standard soil, the range of contaminant concentrations and solution matrix, and various test parameters. Quantifying the uncertainty in the distribution coefficient that can be attributed to the test procedure itself allows the differences in measured values to be associated with differences in the natural systems being studied.

54 ENVIRONMENTAL SCIENCES↗

Atomistic modeling of oil shale kerogens and asphaltenes along with their interactions with the inorganic mineral matrix

The goal of this project is to obtain and validate three dimensional atomistic models for the organic matter in both oil shales and oil sands. In the case of oil shales the modeling was completed for kerogen, the insoluble portion of the organic matter; for oil sands it was for asphaltenes, a class of molecules found in crude oil. The three dimensional models discussed in this report were developed starting from existing literature two dimensional models. The models developed included one kerogen, based on experimental data on a kerogen isolated from a Green River oil shale, and a set of six representative asphaltenes. Subsequently, the interactions between these organic models and an inorganic matrix was explored in order to gain insight into the chemical nature of this interaction, which could provide vital information in developing efficient methods to remove the organic material from inorganic mineral substrate. The inorganic substrate used to model the interaction was illite, an aluminum silicate oxide clay. In order to obtain the feedback necessary to validate the models, it is necessary to be able to calculate different observable quantities and to show that these observables both reproduce the results of experimental measurements on actual samples as well as that the observables are sensitive to structural differences between models. The observables that were calculated using the models include 13 C NMR spectra, the IR vibrational spectra, and the atomic pair wise distribution function; these were chosen as they are among the methods for which both experimental and calculated values can be readily obtained. Where available, comparison was made to experiment results. Finally, molecular dynamic simulations of pyrolysis were completed on the models to gain an understanding into the nature of the decomposition of these materials when heated.

04 OIL SHALES AND TAR SANDS↗

Noise Analysis of Spatial Phase coding in analog Acoustooptic Processors

Optical beams can carry information in their amplitude and phase; however, optical analog numerical calculators such as an optical matrix processor use incoherent light to achieve linear operation. Thus, the phase information is lost and only the magnitude can be used. This limits such processors to the representation of positive real numbers. Many systems have been devised to overcome this deficit through the use of digital number representations, but they all operate at a greatly reduced efficiency in contrast to analog systems. The most widely accepted method to achieve sign coding in analog optical systems has been the use of an offset for the zero level. Unfortunately, this results in increased noise sensitivity for small numbers. In this paper, we examine the use of spatially coherent sign coding in acoustooptical processors, a method first developed for digital calculations by D. V. Tigin. This coding technique uses spatial coherence for the representation of signed numbers, while temporal incoherence allows for linear analog processing of the optical information. We show how spatial phase coding reduces noise sensitivity for signed analog calculations.

Gary, Charles K.↗

Nanostructures Exploit Hybrid-Polariton Resonances

Nanostructured devices that exploit the hybrid-polariton resonances arising from coupling among photons, phonons, and plasmons are subjects of research directed toward the development of infrared-spectroscopic sensors for measuring extremely small quantities of molecules of interest. The spectroscopic techniques in question are surface enhanced Raman scattering (SERS) and surface enhanced infrared absorption (SEIRA). An important intermediate goal of this research is to increase the sensitivity achievable by these techniques. The basic idea of the approach being followed in this research is to engineer nanostructured devices and thereby engineer their hybrid-polariton resonances to concentrate infrared radiation incident upon their surfaces in such a manner as to increase the absorption of the radiation for SEIRA and measure the frequency shifts of surface vibrational modes. The underlying hybrid-polariton-resonance concept is best described by reference to experimental devices that have been built and tested to demonstrate the concept. The nanostructure of each such device includes a matrix of silicon carbide particles of approximately 1 micron in diameter that are supported on a potassium bromide (KBr) or poly(tetrafluoroethylene) [PTFE] window. These grains are sputter-coated with gold grains of 40-nm size (see figure). From the perspective of classical electrodynamics, in this nanostructure, that includes a particulate or otherwise rough surface, the electric-field portion of an incident electromagnetic field becomes concentrated on the particles when optical resonance conditions are met. Going beyond the perspective of classical electrodynamics, it can be seen that when the resonance frequencies of surface phonons and surface plasmons overlap, the coupling of the resonances gives rise to an enhanced radiation-absorption or -scattering mechanism. The sizes, shapes, and aggregation of the particles determine the frequencies of the resonances. Hence, the task of designing a nanostructure to exhibit the desired radiation-absorption properties translates, in large part, to selecting particle sizes and shapes to obtain the desired enhanced coupling of energy from photons to plasmons and phonons. To broaden the spectral region(s) of enhanced absorption, one would select a distribution of particle sizes and shapes.

Anderson, Mark↗

Evaluation of Rapid for a UNF cask benchmark problem

To ensure criticality safety and maintain a high level of security of Used Nuclear Fuel (UNF), it is necessary to perform detailed Particle Transport simulations. The commonly used technique is the 3-D, continuous energy Monte Carlo method that is time-consuming and, for eigenvalue calculations, may have difficulties with the source convergence. Wenner and Haghighat and Dufek demonstrated that in criticality problems with high dominance ratio and/or under-sampling possibilities, the fission matrix (FM) methodology should be used in order to be able to obtain unbiased solution. The RAPID (Real-time Analysis for Particle transport and In-situ Detection) code system is based on the Multi-stage Response-function Transport (MRT) methodology, and uses the FM formulation to determine eigenvalue, subcritical multiplication and fission density distribution of nuclear systems. This paper uses a benchmark problem similar to the GBC-32 Cask to evaluate the accuracy and performance of RAPID against the results of a reference MCNP solution. We performed a detailed sensitivity analysis on a single-assembly model in order to determine the MCNP eigenvalue parameters necessary to obtain a reliable reference solution. These results provided a guide for the selection of an appropriate set of parameters for the eigenvalue calculation for the whole cask. The paper is organized as follows: initially, the RAPID code system is briefly discussed; then, the benchmark problem is introduced. The methodology used to analyze results is proposed and some of the results of different cases are analyzed to identify the best set of eigenvalue parameters for a reference MCNP calculation. The selected case is then compared with the RAPID calculation for both a single assembly and a full cask model. In the end some conclusions and future work perspectives are drawn.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Breakage mechanics for granular materials in surface-reactive environments

It is known that the crushing behaviour of granular materials is sensitive to the state of the fluids occupying the pore space. Here, in this work, a thermomechanical theory is developed to link such macroscopic observations with the physico-chemical processes operating at the microcracks of individual grains. The theory relies on the hypothesis that subcritical fracture propagation at intra-particle scale is the controlling mechanism for the rate-dependent, water-sensitive compression of granular specimens. First, the fracture of uniaxially compressed particles in surface-reactive environments is studied in light of irreversible thermodynamics. Such analysis recovers the Gibbs adsorption isotherm as a central component linking the reduction of the fracture toughness of a solid to the increase of vapour concentration. The same methodology is then extended to assemblies immersed in wet air, for which solid-fluid interfaces have been treated as a separate phase. It is shown that this choice brings the solid surface energy into the dissipation equations of the granular matrix, thus providing a pathway to (i) integrate the Gibbs isotherm with the continuum description of particle assemblies and (ii) reproduce the reduction of their yield strength in presence of high relative humidity. The rate-effects involved in the propagation of cracks and the evolution of breakage have been recovered by considering non-homogenous dissipation potentials associated with the creation of surface area at both scales. It is shown that the proposed model captures satisfactorily the compression response of different types of granular materials subjected to varying relative humidity. This result was achieved simply by using parameters based on the actual adsorption characteristics of the constituting minerals. The theory therefore provides a physically sound and thermodynamically consistent framework to study the behaviour of granular solids in surface-reactive environments.

36 MATERIALS SCIENCE↗

Tumor Retention of Enzyme-Responsive Pt(II) Drug-Loaded Nanoparticles Imaged by Nanoscale Secondary Ion Mass Spectrometry and Fluorescence Microscopy

In nanomedicine, determining the spatial distribution of particles and drugs, together and apart, at high resolution within tissues, remains a major challenge because each must have a different label or detectable feature that can be observed with high sensitivity and resolution. We prepared nanoparticles capable of Enzyme-Directed Assembly of Particle Therapeutics (EDAPT), containing an analog of the Pt(II)-containing drug oxaliplatin, an 15 N-labeled monomer in the hydrophobic block of the backbone of the polymer, the near-infrared dye Cy5.5, and a peptide that is a substrate for tumor metalloproteinases in the hydrophilic block. When these particles reach an environment rich in tumor associated proteases, the hydrophilic peptide substrate is cleaved, causing the particles to accumulate through a morphology transition, locking them in the tumor extracellular matrix. To evaluate the distribution of drug and EDAPT carrier in vivo , the localization of the isotopically labeled polymer backbone was compared to that of Pt by Nanoscale Secondary Ion Mass Spectrometry (NanoSIMS). The correlation of NanoSIMS with super-resolution fluorescence microscopy revealed the release of the drug from the nanocarrier and co-localization with cellular DNA within tumor tissue. The results confirmed the dependence of particle accumulation and Pt(II) drug delivery on the presence of an MMP substrate and demonstrated antitumor activity. We conclude that these techniques are powerful for the elucidation of the localization of cargo and carrier, and enable a high-resolution assessment of their performance following in vivo delivery.

60 APPLIED LIFE SCIENCES↗

Simultaneous isotopic analysis of fission product Sr, Mo, and Ru in spent nuclear fuel particles by resonance ionization mass spectrometry

Abstract Fission product Sr, Mo, and Ru isotopes in six 10-μm particles of spent fuel from a pressurized water reactor were analyzed by resonance ionization mass spectrometry (RIMS) and evaluated for utility in nuclear material characterization. Previous measurements on these same samples showed widely varying U, Pu, and Am isotopic compositions owing to the samples’ differing irradiation environments within the reactor. This is also seen in Mo and Ru isotopes, which have the added complication of exsolution from the UO 2 fuel matrix. This variability is a hindrance to interpreting data from a collection of particles with incomplete provenance since it is not always possible to assign particles to the same batch of fuel based on isotopic analyses alone. In contrast, the measured 90 Sr/ 88 Sr ratios were indistinguishable across all samples. Strontium isotopic analysis can therefore be used to connect samples with otherwise disparate isotopic compositions, allowing them to be grouped appropriately for interpretation. Strontium isotopic analysis also provides a robust chronometer for determining the time since fuel irradiation. Because of the very high sensitivity of RIMS, only a small fraction of material in each of the 10 μm samples was consumed, leaving the vast majority still available for other analyses.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Submicrometer spectromicroscopy of UO 2 aged under high humidity conditions

We report the oxidation of uranium dioxide is a complicated process, depending on factors including humidity, temperature, and microstructure. To further determine the characteristics of this process, UO 2 particles were allowed to age and agglomerate under 98% relative humidity at room temperature for 378 days. A focused ion beam (FIB) section of this agglomeration was then measured at the O K-edge, U N 5 -edge, and C K-edge using the scanning transmission x-ray microscope (STXM) at the Advanced Light Source. O K-edge and U N 5 -edge x-ray absorption measurements allowed for the elemental and chemical species mapping of the agglomerates and indicated the formation of schoepite at the submicrometer scale in specific locations. Non-negative matrix factorization was employed to elucidate the main components at the O K-edge, which were uranyl (schoepite) formed primarily at the interface of the sample with controlled atmosphere, a UO 2 -like bulk component present in the majority of the sample, and an oxygen species present at the surface of the FIB section, which is likely adsorbed water. STXM spectromicroscopy measurements at the U N 5 -edge measurements also confirmed the location of oxidized uranium. This analysis is a valuable insight into the formation of schoepite on UO 2 and shows the sensitivity to and utility of STXM spectromicroscopy for uranium speciation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗